Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹23.2 L+₹10,509 (0.45%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹24.8 L+₹1.7 L (7.45%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹26.5 L+₹3.4 L (14.6%)Rejected-Finance 33 MAHAVEER NAGAR NANDRI ROAD PO SARAN NAGAR JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹27.5 L+₹4.4 L (19.2%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹31.1 L
EMD Value
₹62,260
Closing Date
11 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Banar
Garrison Engineer, Banar, Jodhpur-342027
SPL REPAIR TO HANGER BLDG NO T-1 AT NAGTALAO UNDER GE BANAR IN ARMY AREA JODHPUR
2022_MES_569107_1
8822/62/E8
Open Tender
Civil Works
Item Rate
180 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹62,260
Yes
1 Feb 2023
14 Dec 2022
13 Jan 2023
14 Dec 2022
11 Jan 2023
28 Dec 2022
Amount
Dismantling of Plain or corrugated steel sheeting, any gauge,thickness, including Nainital or similar pattern roof coverings at roof heigth 8 metre and above complete all as specified.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with hot dip galvanised self drilling fasteners with EPDM washers (one fastener on each crest) complete all as specified. Note:- Roof height above 8m.
M&L for preparing new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red-oxide primer as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified.
M & L Roof trusses (framed), trusses, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc con-forming to Fe 410 -W (Gde-E- 250) complete all as specified.
M&L for preparation of old steel surface of any description over 10cm in width or grith and appling one coat of synthetic enamel paint complete all as specified
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips complete all as specified.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in square exceeding 0.5 sqm each panel complete all as specified.
Taking down Chowkats or frames with shutters not exc. 1.5 Sqm each complete all as specified and directed by Engineer-in-Charge.
S&F of steel window with side hung shutter including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified.
M&L for demolition of existing Pavement n.exc 15 cm thickness by mechanical means and removing the debris outside MD land complete all as specified.
M&L for HDPE film black 200 micron thick including 50mm thick sand cushioning complete all as specified.
M&L for PQC as in pavement/hardstanding of minimum flexural strength 45 Kg/Sqcm with cement content 400 Kg/Sqm with cement 400 Kg/cum or as per design mix which ever is higher using non circular synthetic fibre @ 0.25% by weight of cement of cement including necessary steel formwork complete all as specified. Notes:- (i) Polyester triangular fibres as secondary reinforcement mixed in concrete shall be measured and paid separately under SI item No 18.00 of, However mixing shall be deemed to be included in the quoted rate. (ii) Construction joints, dummy (contraction joints) and expansion joints shall be measured and paid separately under respective items. (iii) Deduction shall be made in computing concrete quantity for expansion joints. (iv) No price adjustment shall be applicable if excess quantity of cement content is used/approved in the execution of work under this item.
M&L forming 20mm thick expansion joint filled with performed HDME filler applying bond breaker tape on top of filler board for complete width of joint, provn of closed cell polyethylene back up rod 25mm dia, filled with polyethylene sealant (min depth of sealant above back up rod shall be 12mm) complying with BS-5212, priming the sides and applying masking tape on edges of joint to prevent accidental spillage of sealant and removing the masking tape after sealant applied, for thickness of concrete slab 300mm complete all as specified.
M&L for forming contraction (dummy) joints 75mm deep x 10mm wide filled with expand polyethylene form (armour board) applying bond beaker tape on top of armour board for complete width of joint, provn of colsed cell polythylene back up rod 12mm dia sealed with 10mm (depth min above back up rod) polythylene sealant complete with BS-5212, priming sides, masking tape on edges of joint to prevent accidental spillage of sealant on top surfaces and to give a neat finish to the sealant and removing the masking tape after sealant application complete all as specified.
M&L forming construction joints 25mm deep and 10mm wide, and sealed with polyethylene sealant complying with BS-5212 and priming the sides, provn of closed cell polyethelene line back up rod 12mm dia and applying masking tape on edges of joint to prevent accidental spillage of sealant on top surfaces and to give a neat finish to the sealant applied complete all as specified.
M&L for brooming on finished surface of PQC to make it rough surface complete all as specified.
Supply only polester triangular fibers as secondary reinforcement all as specified.
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness below or above ground level complete all as specified.
M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring complete all as specified.
M&L machine pressed precast concrete interlocking paver block 80mm thick of any shape and size confirming to IS 15658-2006, M-40 Grade with grey cement and pigment (Robourised) complete all as specified.
M&L for 25 mm thick sand cushioning/filling under floor including watering and consolidation complete all as specified.
M&L Pre-cast concrete block as in Kerb Stone (Machine made) with solid blocks Type B1 1:2:4 (20 mm graded aggregate) exc 10 cm in width and setting in cement mortar 1:4 complete all as specified.
Demolition of stone/brick masonary built in cement mortar complete all as specified.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) as specified.
M&L for preparation new plastered or unplastered surface and applying two coat of cement base paint on walls complete all as specified.
Preparing old decorated plastered or unplastered surfaces by brooming down of steel wire brushing, scrapping down moulds mass and efforescent salt and treating oil greasy spots and stopping of distemper and applying one coat of oil emulsion (bound) distemper on wall complete all as specified.
Taking down carefully aluminium/copper point wiring ( Light, fan, socket or power) complete including fixture and fitting such as switches,ceiling roses,pendents,regulators,sockets,light fitting etc and making good the disturbed surfaces finishing of wall / floor etc, complete all as specified.
Taking down unserviceable rusted/damaged sheet metal enclosure DBs of any size/type/ways from wall complete all as specified.
M&L for point wiring with 1.5 Sq mm single core multi-stranded copper conductor PVC (FRLS) insulated, sheated cable 1100 volt grade in suitable size of stove enamelled steel condiuit (ISI marked) with accessories concealed in wall/ceiling with ERW sleeves as per relevant IS excluding pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.50 Sqmm single core, multi stranded copper conductor, PVC insulated, unsheated cable for common earth and connecting for earth dolly for :-
One light point/fan controlled by one switch.
One switch socket out let point 5 Amps on independent board
Ditto all as per item No.30.00 herein before but with 4 sqmm cable for one 15 Amp flame proof switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified.
Supply and fix in replacement LED light fitting, 2x20 W LED, Flameproof proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protectionw ith die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessoriesprewired and including connecting up with threecore flexible copper conductor cable with suitable complete all as specified.
Supply and fix in replacement flame proof exhaust fan 305 mm sweep of single phase with all accessories complete all as specified.
Supply and fix in replacement switch Single pole, 250V, Flame proof, Rotary type with termination box in LM6 complete all as specified.
Supply and fix in replacement Flame proof switch socket & plug combined in LM6 ,16 A, 250 V (2P+Earth) complete all as specified.
Supply and fix in replacement switch socket & plug combined in LM6 ,16 A, 250 V (3P+Earth) complete all as specified.
Supply and fix in replacement flame proof junction box with plain cover, entry size 3/4 ET, 3 waycomplete all as specified.
Supply and fix in replacement Flameproof Distribution board SPN 8 way Double door with 100 amps rated bus bar Incoming MCB DP 32A-01 and outing MCB single pole 6-10 Amp- 04 with complete internal wiring up to terminalsas per specification all as directed by engineer in Charge
Supply,Fixing in replacement and installation Heavy duty wall mounted Air Circulatoroscillating type Fan 600mm sweep 1440 RPM single phase 250 W vertical angle adjustment from 22 to 45 degree push button three speed control by regulator (including in this price) to connect by using cable PVC insulated copper stranded conductor of size 2.5 Sqmm 3 core and overall PVC sheathed which shall be passed through PVC flexible conduit complete all as specified.
S&F of in replacement Flame proof building security light LED fitting with pressure die cast housing, epoxy powder coated dark graphite grey colour finish and prismatic polycarbonate cover with individual LED lences suitable for including lamp LED 45 watt, fixed / connect properly at directed location on building complete all as specified.
Supply and fixing in replacement bracket for street light fittings of any size made out of GI pipe medium grade 32 mm dia 1.25 mtr length bend to required size and shape including provision of clamps and fittings in position and two coat of aluminum paint over a coat of red oxide primer all as specified and directed including taking down old bracket complete all as specified.
M & L for building earthing in replacement complete with galvanised steel earth plate electrode 60 x 60x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron strip 32x6mm as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 all as directed by Engr-in-Charge
Excavation in trenches not. exc. 1.5m wide and not exc. 1.5 deep and getting out in soft/loose soil complete all as specified.
Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified.
Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified.
Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified.
Supply and laying un-reinforced precast concrete cable cover class LV type-1 size 250mmx150mmx40mm complete as per specification and directed by EIC
supply laying in trenchs or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 25 Sqmm 4 core including taking out old cable complete all as per specification .
Supply and Fixing GI pipe medium grade 40 mm bore laid in floor / wall clamp properly on wall inculding all fittings complete all as specified.
S&F in replacement Flame proof flood light LED fitting with pressure die cast housing, epoxy powder coated dark graphite grey colour finish and prismatic polycarbonate cover with individual LED lences suitable for including lamp LED 90 watt, fixed / connect properly at directed location on building complete all as specified.
S AND S Constructions
M.A. MUNSHI AND CO.
DIWAKAR CONSTRUCTION CO.
Shri Electrical Enterprises
MOHIT ENTERPRISES
M/S Dharam Chand Lal Chand Jain
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .