| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | ₹21.8 L Quoted ₹22.2 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹22.7 L+₹43,428 (1.95%)Rejected-AOC PREM NAGAR GALI NO 3 RAJPUTANA SALEMPUR ROORKEE DISTT HARIDWAR UK | ROORKEE | HARIDWAR | UTTARAKHAND | ₹22.7 L+₹43,428 (1.95%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹23.2 L+₹94,078 (4.23%)Rejected-AOC | ₹23.2 L+₹94,078 (4.23%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹24.0 L+₹1.8 L (8.04%)Rejected-AOC | ₹24.0 L+₹1.8 L (8.04%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹24.5 L+₹2.3 L (10.3%)Rejected-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | ₹24.5 L+₹2.3 L (10.3%) | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | A ONE BUILDERS AND ENGINEERS L1 | M/S Konark Electric Sales Corporation L2 | VIJAY ENTERPRISES L7 | Friends fire Engineers L5 | V r traders L6 | V.K. Enterprises L8 | Bhanu Prakash L3 | PANTECH INSTRUMENTS AND SERVICES L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Labour only for lifting /taking up of defective submersible pumping set of capacity 60 HP to 100 HP from deep tube well and dismantling of connected rising main i.e. non return valve, bend etc from delivery of pump set, lifting of column pipe of size 150 mm dia fixed with pumping set, unscrewing of column pipes from socket / flange cutting of welded strip unscrewing of cable holding clamps and disconnecting of submersible cable joint complete all as directed by Engineer-in-charge. | 4 | Each Job | 13,200 ₹52,800 | 9,000 ₹36,000 Lowest | 15,000 ₹60,000 | 12,999 ₹51,996 | 12,999 ₹51,996 | 18,000 ₹72,000 | 9,000 ₹36,000 Lowest | 22,000 ₹88,000 |
| 2.00 | Labour only for lowering of submersible pumping set of capacity 60 HP to 100 HP after repair and testing in deep tube well not less than 90 mtr below the ground level including lowering of column pipe size 150 mm dia by screwing with socket/flange welding or fixing MS strips, fixing of cable clamps etc up to the maximum depth of 150 mtr complete all as directed by Engineer-in-charge.
Note: (i) Jointing material will be measured and paid separately. (ii) Repair of column pipe will be measured and paid separately. (iii) Contractor shall caution his staff during execution to take maximum precaution while lifting/lowering the pump set at site. In case any accident/injuries occurs the department will not held responsible for any miss happening due to negligence on their (workers) parts. Contractor shall be held totally responsible and all penalty /damages on this account shall be born by the contractor. (iv Old material retrieved during lowering /lifting the contractor shall deposit to MES store yard without any extra cost. | 4 | Each Job | 13,200 ₹52,800 | 9,000 ₹36,000 Lowest | 15,000 ₹60,000 | 12,999 ₹51,996 | 12,999 ₹51,996 | 18,000 ₹72,000 | 9,500 ₹38,000 | 22,000 ₹88,000 |
| 3.00 | S&F of Cable jointing kit ( compound ) suitable for submersible cable of size up to 50 sqmm 3 core complete all as directed by Engineer-in-charge. | 4 | Each | 500 ₹2,000 | 500 ₹2,000 | 2,000 ₹8,000 | 499 ₹1,996 | 999 ₹3,996 | 5,000 ₹20,000 | 400 ₹1,600 Lowest | 500 ₹2,000 |
| 4.00 | M&L for repair to column pipe 150 mm dia having wall thickness 5 mm and 3 mtr long including transportation to workshop, cutting , threading , fabricating welding of same along with S&F MS flange of 8 mm thick having 150 mm bore dia and 8 Nos hole of 5/8” dia for fixing of nut and bolts on the both ends of the column pipe and welding the same to the pipe by means of MS strips of size 25 x 6 mm on four side of the flanges all as directed by EIC including transportation from workshop to site and stacking at site after repair complete all as specified and directed.
Note: In case any damage or loss of any pipe is noticed during transportation or in custody of the contractor the necessary recovery shall be effected from contractor’s due to this regard | 5 | Each job | 1,200 ₹6,000 | 1,200 ₹6,000 | 1,000 ₹5,000 | 1,999 ₹9,995 | 1,499 ₹7,495 | 8,000 ₹40,000 | 500 ₹2,500 Lowest | 1,000 ₹5,000 |
| 5.00 | S&F rubber packing suitable for 150 mm dia flange 3 mm thick complete all as directed by Engineer-in-charge. | 120 | Each | 50 ₹6,000 | 40 ₹4,800 Lowest | 50 ₹6,000 | 99 ₹11,880 | 119 ₹14,280 | 100 ₹12,000 | 50 ₹6,000 | 100 ₹12,000 |
| 6.00 | M&L in repair for overhauling of submersible motor 75 HP to 100 HP AC 3 phase by dismantling , opening into parts cutting of burnt winding, cleaning of slots, balancing of rotor, cleaning polishing and rewinding with same gauge of PVC insulated copper wire & testing all as specified & directed by Engr-in-Charge.
Note : Spare parts shall be measured & paid separately | 4 | Each job | 50,000 ₹2,00,000 | 25,000 ₹1,00,000 Lowest | 55,000 ₹2,20,000 | 34,999 ₹1,39,996 | 34,999 ₹1,39,996 | 95,000 ₹3,80,000 | 26,000 ₹1,04,000 | 25,000 ₹1,00,000 Lowest |
| 7.00 | Supply only Thrust plate suitable for 75 HP to 100 HP submersible motor as per existing type and size complete all as directed by Engineer-in-charge. | 4 | Each | 4,000 ₹16,000 | 1,500 ₹6,000 | 8,000 ₹32,000 | 2,999 ₹11,996 | 2,499 ₹9,996 | 38,000 ₹1,52,000 | 1,500 ₹6,000 | 800 ₹3,200 Lowest |
| 8.00 | Supply only Thrust pad suitable for 75 HP to 100 HP submersible motor as per existing type and size complete all as directed by Engineer-in-charge. | 4 | Each | 3,000 ₹12,000 | 1,500 ₹6,000 | 5,000 ₹20,000 | 199 ₹796 Lowest | 1,499 ₹5,996 | 10,000 ₹40,000 | 1,500 ₹6,000 | 800 ₹3,200 |
| 9.00 | Supply only Bearing bush lower suitable for 75 HP to 100 HP submersible motor as per existing type and size complete all as directed by Engineer-in-charge. | 4 | Each Set | 3,000 ₹12,000 | 1,200 ₹4,800 | 3,000 ₹12,000 | 999 ₹3,996 | 1,499 ₹5,996 | 8,000 ₹32,000 | 1,000 ₹4,000 | 500 ₹2,000 Lowest |
| 10.00 | Supply only Bearing bush upper suitable for 75 HP to 100 HP submersible motor as per existing type and size complete all as directed by Engineer-in-charge. | 4 | Each Set | 2,000 ₹8,000 | 1,000 ₹4,000 | 3,000 ₹12,000 | 999 ₹3,996 | 999 ₹3,996 | 8,000 ₹32,000 | 1,000 ₹4,000 | 700 ₹2,800 Lowest |
Tender Value
₹44.8 L
EMD Value
₹89,620
Closing Date
4 Aug 2025, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
REPAIR AND MAINT OF LOWERING and LIFTING OF SUBMERSIBLE CENTRIFUGAL, MONOBLOCK PUMP SETS SWIMMING POOL FILTER PLANT ROUTINE MAINT OF SWIMMING POOLS INCL CONNECTED WORKS AT UNDER GE IMA DEHRADUN
2025_MES_718430_1
0081/IMA/E8
Open Tender
Civil Works
Works
180 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
GE IMA Dehradun
₹89,620
Yes
10 Sept 2025
4 Jul 2025
6 Aug 2025
4 Jul 2025
4 Aug 2025
21 Jul 2025
Amount
Labour only for lifting /taking up of defective submersible pumping set of capacity 60 HP to 100 HP from deep tube well and dismantling of connected rising main i.e. non return valve, bend etc from delivery of pump set, lifting of column pipe of size 150 mm dia fixed with pumping set, unscrewing of column pipes from socket / flange cutting of welded strip unscrewing of cable holding clamps and disconnecting of submersible cable joint complete all as directed by Engineer-in-charge.
Labour only for lowering of submersible pumping set of capacity 60 HP to 100 HP after repair and testing in deep tube well not less than 90 mtr below the ground level including lowering of column pipe size 150 mm dia by screwing with socket/flange welding or fixing MS strips, fixing of cable clamps etc up to the maximum depth of 150 mtr complete all as directed by Engineer-in-charge. Note: (i) Jointing material will be measured and paid separately. (ii) Repair of column pipe will be measured and paid separately. (iii) Contractor shall caution his staff during execution to take maximum precaution while lifting/lowering the pump set at site. In case any accident/injuries occurs the department will not held responsible for any miss happening due to negligence on their (workers) parts. Contractor shall be held totally responsible and all penalty /damages on this account shall be born by the contractor. (iv Old material retrieved during lowering /lifting the contractor shall deposit to MES store yard without any extra cost.
S&F of Cable jointing kit ( compound ) suitable for submersible cable of size up to 50 sqmm 3 core complete all as directed by Engineer-in-charge.
M&L for repair to column pipe 150 mm dia having wall thickness 5 mm and 3 mtr long including transportation to workshop, cutting , threading , fabricating welding of same along with S&F MS flange of 8 mm thick having 150 mm bore dia and 8 Nos hole of 5/8” dia for fixing of nut and bolts on the both ends of the column pipe and welding the same to the pipe by means of MS strips of size 25 x 6 mm on four side of the flanges all as directed by EIC including transportation from workshop to site and stacking at site after repair complete all as specified and directed. Note: In case any damage or loss of any pipe is noticed during transportation or in custody of the contractor the necessary recovery shall be effected from contractor’s due to this regard
S&F rubber packing suitable for 150 mm dia flange 3 mm thick complete all as directed by Engineer-in-charge.
M&L in repair for overhauling of submersible motor 75 HP to 100 HP AC 3 phase by dismantling , opening into parts cutting of burnt winding, cleaning of slots, balancing of rotor, cleaning polishing and rewinding with same gauge of PVC insulated copper wire & testing all as specified & directed by Engr-in-Charge. Note : Spare parts shall be measured & paid separately
Supply only Thrust plate suitable for 75 HP to 100 HP submersible motor as per existing type and size complete all as directed by Engineer-in-charge.
Supply only Thrust pad suitable for 75 HP to 100 HP submersible motor as per existing type and size complete all as directed by Engineer-in-charge.
Supply only Bearing bush lower suitable for 75 HP to 100 HP submersible motor as per existing type and size complete all as directed by Engineer-in-charge.
Supply only Bearing bush upper suitable for 75 HP to 100 HP submersible motor as per existing type and size complete all as directed by Engineer-in-charge.
M&L in repair for overhauling of submersible pump of 5 to 7 stage approx 1900 LPM, dismantling the pump, repair/ overhauling complete and reassembling after repair, transportation back to pump house including replacing the parts: Note: Spare parts will be measured and paid separately
Supply only Impeller bronze suitable for 5 to 7 stage submersible pump as per existing type and size complete all as directed by Engineer-in-charge.
Supply only Stage sleeve suitable for 5 to 7 stage submersible pump as per existing type and size complete all as directed by Engineer-in-charge.
Supply only Neck ring suitable for 5 to 7 stage submersible pump as per existing type and size complete all as directed by Engineer-in-charge.
Supply only Running bush suitable for 5 to 7 stage submersible pump as per existing type and size complete all as directed by Engineer-in-charge.
Supply only Sand guard suitable for 5 to 7 stage submersible pump as per existing type and size. Note : All repair work and spare parts from item No 7 to 10 & 12 to 16 shall be carried out from authorized dealer /approved firms as approved by the EIC and submit purchase voucher in this regard
Supply and fixed in repair Submersible cable PVC insulated, multi stranded, copper conductor 3 core, 35 sq mm flat, 1100 volt grade completed all as specified and directed.
S&F in repair for Digital volt meter 0 to 500 volt digital type completed all as specified and directed.
S&F in repair for Digital amp meter 0 to 200 Amp digital type completed all as specified and directed.
S&F in repair for LED Indicator lamp (set of three) completed all as specified and directed.
S&F in repair for Single phase preventor completed all as specified and directed.
S&F in repair for Change over switch off load 3 phase 415 volts 250 Amps , four pole on load type complete all as directed by Engineer-in-charge.
S&F in repair for Change over switch off load 3 phase 415 Volt, 200 Amp, four pole on load type complete all as directed by Engineer-in-charge.
M&L for taking down of existing unserviceable pressure gauge from rising main, supply and fixing pressure gauge as pressure range upto 10 Kg/Sqcm, existing in size on rising main, testing complete all as directed by Engineer-in-charge.
S&F in repair of column pipe 150 mm dia flanged, 3mtr long including taking up old unsv pipes and lowering of of new pipe in the tube well carefully by the help of chain pulley complete all as specified and directed.
Supply and fix in repair 15mm dia long stick Adjustable Vertical Foggy jet Nozzles for Fountain system in Gunmetal Grade to produce Foggy effect with GI Fittings as per latest IS complete all as specified and directed.
M&L for taking up defective submersible pumping set horizontal type of capacity 3 HP disconnecting delivery pipe line. Repair/ over hauling 3 HP AC 415 Volts opening into parts cutting of burnt winding, cleaning, slots, balancing of rotor, cleaning, polishing and rewinding the motor with same gauge of PVC insulated copper wire, replacement of impeller and bearing including testing complete all as specified and directed.
All as per item No. 27 here in before but capacity 5 HP
All as per item No. 27 here in before but capacity 7.5 HP
M&L for taking up defective multi stage high efficiency pressure pumping set of 1 HP disconnecting delivery pipe line. Repair/overhauling 1 HP, AC 230 volts opening into parts cutting of burnt winding, cleaning, slots, balancing of rotor, cleaning polishing and rewinding with same gauge of PVC insulated copper wire, replacement of impeller pressure switch and cleaning including testing complete all as specified and directed
M&L for MS nut, bolt, washers, bracket of angle or tee cut to shape including cutting, welding, bending for gates and ladder complete all as specified and directed by Engr- in- charge.
Supply and top up transformer oil of dielectric strength upto 50 KA for submersible motor starter and oil cooled auto transformer complete all as specified and directed.
M&L for copper lugs of size 70 sq mm
M&L for copper lugs of size 50 sq mm
M&L for copper lugs of size 35 sq mm
Supply and replacement of pressure switch KP 35 for pressure booster pump pressure range upto 4.0 kg/Sqcm for 25 mm dia inlet and outlet size with MS flange 25mm dia complete all as specified and directed.
M&L for removing / uprooting of shrubs, cleaning of grass and bushes inside water supply installation surrounding deployed by adequate strength of worker, cleaning carryout within 6 months complete all as specified and directed
S&F in replacement DOL motor starter in sheet metal enclosure AC, 415 volts,TP,50 c/s of capacity 3 to 5 HP complete all as specified and directed
M&L for taking down old unserviceable PVC spiral hose pipe 50 mm external dia and Supply & fix new PVC spiral hose 50 mm external dia floating type for suction sweeper assembly ISI mark complete all as specified and directed
Supply only Nylon Bristol brush of size 875 X 75 mm for suction sweeper assembly as per sample complete all as directed .
Supply and lay in repairs High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches 50 mm bore for protection of submersible cable in trenches including all necessary fittings complete all as specified and as directed. Note: Earth work and excavation shall measured and paid separately.
M&L Silica Quartz sand with pebbles of multi grade sand filter as per the existing by size wise and layer wise after taking out the old sand complete all as specified and as directed.
S&F CI foot valves flanged type of 100 mm bore, cast iron IS 210 FG 260 body, nitrile rubber coated ball, L.T. bronze IS 318 grade seat ring ISI marked (flange drilling) complete all as specified and directed
Supply and fix in repair Protection relay with digital display having protection Over Current , Under Current , Phase Loss ,Phase Reversal , Phase Imbalance, lock rotor,UV,OV,min 5 fault history, Current Rating access from 0.5 Amp - 60 Amp complete all as specified and directed
M&L for taking down defective electric induction motor from base plate after unscrewing nuts bolts of foundation/ coupling , 3 phase, 415/440 volts, 50 C/s, AC, capacity 15 HP, induction motor of any make , shifting the same to workshop, strip opening after unscrewing nut bolts screws etc. taking out rotor from stator, cutting and taking out burnt winding carefully from the stator, cleaning of slots, rewinding of stator with super enamelled copper winding wire of appropriate size matching with manufactures design including replacement of all insulating materials such as glass paper ,leathered paper, PVC insulated copper conductor wire connection leads of appropriate size with sleeves of suitable size up to terminal connection box , varnishing, drying up and re-assembling refixing and reinstallation at site complete and testing on load all as specified and directed by Engineer-in-Charge. Note:- Required T&P and transportation shall be contractors responsibility. Repair/ replacement shall be done within a period as intimated by the Engr-in-Charge failing which necessary recovery shall be made.
All as per item No. 45 here in before but 12.5 HP motor.
All as per item No. 45 here in before but 10 HP motor.
All as per item No. 45 here in before but 7.5 HP motor.
All as per item No. 45 here in before but 5 HP motor.
All as per item No. 45 here in before but 2 HP motor.
M&L for Ball bearing for motor suitable for 05 HP to 15 HP induction motor as per existing type and size complete all as specified and directed
M&L for replacement of greased graphite gland packing of 6mm to 8 mm sizes
M&L for Love joy/Star coupling suitable for 12 HP to 15 HP Centrifugal/Monoblock pump set as per existing type and size
S& F in Repair of CI/MS Coupling Complete with tyre as per existing sample for 15 HP Centrifugal pump set as specified and directed
S& F Hot Water M- Seal of 15 HP centrifugal pump set of Manoj pandey Swimming pool as per existing size and make all as specfied and directed
S&F of M-Seal size 17 no of Manoj pandey swimming pool as per existing size and make all as specfied and directed
M&L for painting to motors, pump sets upto 15 HP including MS Channels, suction and delivery pipes of pump sets up to 5 M length from Pump sets including cleaning the outer surfaces of any description, in any position, applying one coat of synthetic enamel paint with proper colour codes and writing letters of SM No. and MES No. etc., complete all as specified and directed.
Maintenance of Outdoor type Olympic size swimming pool by removing of dirt, sludge, foreign material from wall and floor of swimming pool by using of brushes, rope etc and by the help of suction sweeper complete all as specified and directed,(Salaria Swimming Pool) Note Rate quoted shall include the cost of all tools, expendable materials like brushes broom, rope and minor repair/welding work in suction sweeper brush assembly / trolley etc
All as per item No. 58 here in before but indoor swimming pool (Manoj Pandey Swimming Pool & Plunge bath ) complete all as specified and directed.
supply and fix in replacement of 3/4 inch dia braded rope for suction sweeper complete all as specified and directed.
M & L for complete checking of Starter Panel/Pump Sets, cleaning and servicing, tighting the nut bolts, cable joints, checking of conntactors, relays, aluminium/cu lugs, oil winding and rectified the minor defeccts to make it serviceable condition including replacement of unserviceable spares and testing complete all as specified and as directed by Engr In Charge.
M/S Konark Electric Sales Corporation (BID ID -3374086)
Bhanu Prakash (BID ID -3373839)
PANTECH INSTRUMENTS AND SERVICES (BID ID -3381508)
Friends fire Engineers (BID ID -3380393)
V r traders (BID ID -3381950)
VIJAY ENTERPRISES (BID ID -3374564)
V.K. Enterprises (BID ID -3382796)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .