Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, installation and commissioning of 4.0 TR vertical Split type AC units by dismantling and storing old Vertical machines at Site in the conference hall, Birchandra State Central Library, Agartala
2024_CEPWD_51175_1
25/EE/DNIeT/MECH.DIVN/AGT/2024
Open Tender
Electrical Works
Works
30 days
AGARTALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹14,652
27 Nov 2024
23 Jul 2024
31 Jul 2024
23 Jul 2024
31 Jul 2024
23 Jul 2024
Amount
Providing of Vertical split AC unit of cooling capacity not less than 13000 watt with hermitically sealed compressor operating on R22/R-410 A /non CFC equivalent refrigerants suitable for floor mounting, suitable for operation on 3 Phase AC supply capable of performing A) cooling, B) Dehumidify, C) Air circulation, d) Filtering. etc. complete as per direction of Engineer -in- charge.
Installation and commissioning of 3 TR /4.5 TR vertical split AC unit with vaccumising, Nitrogen pressure testing, first charge of refrigerant including providing Refrigerant & cable connection from MCB to Outdoor/indoor along with electrical Top etc. (upto 3mtr) complete as per direction of the Engineer in Charge .
Providing & installation of Hard Drawn copper piping with insulation for vertical split AC as per direction of the Engineer-In-Charge. 3/4" OD/applicable OD based on manufacturer guideline etc. complete as per direction of Engineer -in- charge.
Providing & installation of Hard Drawn copper piping with insulation for vertical split AC as per direction of the Engineer-In-Charge. 1/2" OD / applicable OD based on manufacturer guideline etc. complete as per direction of Engineer -in- charge.
Providing, fitting & fixing of cradle/suitable structure (Base) made of M.S. angle of 65 x 65 x 6 mm, nuts & bolts etc. i/c painting, fitting, fixing, grouting for placement of outdoor unit complete for vertical split AC as per direction of the Engineer-In-Charge.
Providing, fitting & fixing of suitable structure (Base) made of M.S. angle of 65 x 65 x 6 mm, nuts & bolts etc. i/c painting, fitting, fixing grouting for placement of indoor unit, the M.S base should be enclosed by 12 mm water proof ply with formica pasting/ACP sheet complete for vertical split AC as per direction of the Engineer-in-charge.
providing & fitting fixing of additional (beyond 3 mtr) electric control cable (5C X 4.00 mm) suitable for connection between MCB to out door unit /Indoor unit etc complete as per direction of the Engineer in charge .
Providing and fitting-fixing of VI pad for outdoor unit for Vertical split AC unit as per direction of the Engineer in Charge .
Dismantling of vertical type AC(3.0 TR/4.0 TR) capacity both indoor and outdoor unit with all its accessories, carrying & storing at site provided by user department by engaging labour etc complete as per direction of the Engineer-in-Charge.
R.P.ELECTRONICS (BID ID -146046)
Eastern Commerce (BID ID -146417)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_52039.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .