Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC | L1 | Accepted-AOC Due to lowest bidder | |
| 2 | L2₹39.2 L+₹5.2 L (15.4%)Rejected-Finance | L2 | Rejected-Finance Due to high amount quoted | |
| 3 | L3₹49.3 L+₹15.3 L (45.1%)Rejected-Finance | L3 | Rejected-Finance Due to high amount quoted |
Tender Value
Refer Docs
EMD Value
₹89,900
Closing Date
10 May 2022, 6:00 pmClosed
CWE (A) Jaisalmer
HQ CWE (A) Jaisalmer 345001
REPAIR AND MAINT OF LT/HT UG CABLE/OH LINE AND MISC WORKS AT MIL STATION POKARAN UNDER AGE (I) POKARAN
2022_MES_517653_1
83995
Open Tender
Electrical and Maintenance Works
Works
180 days
Pokaran
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Pokaran
₹89,900
Yes
11 Jul 2022
12 Apr 2022
16 May 2022
12 Apr 2022
10 May 2022
26 Apr 2022
Amount
Supply & errect in position Prestressed concrete pole, 11.0 metres long, 152mm x 152mm at top and 152mm x 260mm at bottom class 9 all as specifid and directed by Engr-in charge
Demolition of concrete in any descripion and in any position not otherwise specifically provided for below or above ground level complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm grade stone aggregate in foundation of pole all as specified & directed by engr-in-charge
M&L for PCC 1:3:6 type C-2 using 40 mm grade stone aggregate in foundation of stay all as specified & directed by engr-in-charge
M&L for PCC 1:2:4 type B-1 using 20mm grade stone aggregate for pole / stay assy copings incl necessary & finishing concrete surface even & smooth without using extra cement all as specified & directed by engr-in-charge
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m
M&L cross arm , bracing support MS clamps etc including necessary fabrication, bolts, nuts, washers etc and painting with one coat of red oxide and two coats of aluminium paints all as directed complete.
Dismantling of ACSR conductors from existing pole and removing from site all as directed by Engr -in Cahrge.
M&L for providing HT/LT over head lines on prestressed concrete poles with aluminium conductor steel reinforced (ACSR) including straining properly on insulator and binding with aluminium binding wire, connectors and jumpers etc complete all as specified & directed by Engineer-in-charge. (Mink, Dog, Lion, Weasel, Ferret or Squirrel). NOTE:- Measurement for the purpose of payment shall be made by measuring horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size and length and adding 3% extra for sag, joints, jumpers etc.
Taking down old unserviceable HT 11 KV UG cable of size 95 sqmm x 3 core with jointing kit etc complete all as specified and directed at site.
Taking down old unserviceable HT 11 KV UG cable of size 120 sqmm x 3 core with jointing kit etc complete all as specified and directed at site.
Taking down old unserviceable HT 11 KV UG cable of size 185 sqmm x 3 core with jointing kit etc complete all as specified and directed at site.
Laying of XLPE insulate, armoured, heavy duty electric cable, aluminium conductor, 11000 volts grade of cross sectional area 95 sqmm x 3 core connected to both side connection complete all as specified and directed by the Engr-in-chrge. Note : (i) Excavation and earth work will be measured and paid separately. (ii) Cable will be issued under Sch 'B' for free for laying only at MES store yard AGE(I) Pokaran. (iii) Transporting and shifting,loading/unloading of cable will be done by contractor from MES store yard to site.Cost of transporting deemed to included in quated rate of the items. (iv) Testing of cable shall be carried out before issue under Sch 'B' as well as after lying by the contractor.Cost of testing deemed to included in quated rate of the items. (v) Jointing kit will be measured and paid separately.
All as per ser item No 14 above here in before but size of cable 120 sqmm x 3 core
All as per ser item No 14 above here in before but size of cable 185 sqmm x 3 core
Fixing/jointing of heat shrink type cable jointing kit for outdoor termination suitable for 11 KV grade 3 core 50 to 95 sqmm including testing complete all as specified and directed by Engr-in-Charge
All as per item no 17 here in before but size of jointing kit 120 to 185 sqmm
Fixing/jointing of heat shrink type cable jointing kit for straight through suitable for 11 KV grade 3 core 50 to 95 sqmm including testing complete all as specified and directed by Engr-in-Charge
All as per item no 19 here in before but size of jointing kit 120 to 185 sqmm
Taking down the old unserviceable/rusted light grade GI pipe of size 80 mm dia complete all as specified and directed at site.
All as per ser item No 21 here in before but size of GI pipe 50 mm dia
Laying only GI tubing light grade of sie 80 mm dia for protection of cable in trenches /on pole all as directed by Engr-in-Charge. Note : (i) GI pipe will be issued under Sch'B' for free for laying only at MES store yard AGE(I) Pokaran. (ii) Excavation and earth work,sand,pipe and stone patti will be measured and paid separately.
All as per ser item No 23 here in before but size of GI pipe 50 mm dia
M&L for danger notice plate of 1.6 mm thick mild steel sheet,viterous enamelled white,with letters,figures and conventional skull and bones in single red clour and fixed with M.S.Clamps bolts and nuts of approved size for HT 25 x 20 cm .
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating meachanism for repair/replacement of broken/worn out components and insulators etc.
Supply installation commissioning & testing switch air break gange operated triple pole mechanically operated vertical/horizontal type on HT insulator 12 insulator type and MS galvanised steel frame with operating mechanism worked from ground level including operating rod for current rating upto 400 amps 11000 volts complete with locking arrangement MS clamp,bolts,nut and washer etc including drop out explusion type fuse with fuse barrels of required capacity to suit load at site including two coats of aluminium paint over a coat of red oxide primer on mS work complete all as specified & directed by EIC ins
Supply and fix lightning arresters suitable for 11 KV grade explusion type complete with all fittings,transmission class, discharge capacity 65 kilo amp complete all as specified and directed at site.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wider and 1.5 mtr depth for laying of cables and foundation etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
Excavation in trenches in hard/dense soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
Removing excavated material any type n exc 50 mtr and depositing at a level n.exc 1.5 m above ground
Returning /filling in layers ,spreading leveling ,watering and well ramming in layers n.exc 25 m in soft /loose soil
M&L for sand cushioning to XLPE cable with tibba sand and punning to provide required cover all as directed
Supply and laying Jodhpur stone patti for cable protection of length between 55 to 60 cm but width between 25 to 30 cm thickness not less than 5 cm complete as per site requirement incl removing old unsv patti and direction of Engineer-in-Charge.
M&L for black paint synthetic enamelled paint two coats on pedastal above GL prepared in above item and all as directed by Engr-in-Charge.
M&L for cutting ,trimming and vending tree branches falling on overhead lines (HT/LT) after arranging electrical shutdown from department or RSEB including taking all precautions while working on lines. Note : (i) The length of span between two poles shall be measured in which trees are falling on overhead electric conductors. (ii) required T&P will be arranged by the contractor at his own cost.
Dismantling of u/s existing earthing with strip 32 x 6 mm and 10/8 SWG wire complete including removing PCC from site.
M & L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth strip of size 32 mm x 6 mm by means of nut, bolts,washer, check nut & other end connected to earth test point or lightening arrester or main controlling switch as directed including providing funnel with 20 mm bore galvanised iron pipe (light grde),wire mesh charcoal or coke and common salt in alternate layer of 15 cm (compacted thickness) all round the earth electrode ,concrete pit PCC (1:3;6) type C-1 (with 20 mm graded aggregate) 50 mm thick precast RCC (1:2:4) cover slable (re- inforced with 8 mm dia TMT bar @ 15 cm both ways and suitable handle made of 10 mm dia ) including necessary earth work in excavation ,returning filling and removal of surplus earth upto a distance exceeding 50 mtr etc all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed by Engr-in-Charge.
M & L for earthing complete with GI plate electrode 600x600x6 mm thick, burried directly and preferably vertically in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 m below ground level connected to GI earthing lead of 4 mm dia GI steel wire all as shown in plate No 3 of SSR PartI 2009 to earthing test point including providing funnel with 20 mm bore galvanised iron pipe (light grade),wire mesh charcoal or coke and common salt in alternate layer of 15 cm (compacted thickness) all round the earth electrode ,concrete pit PCC (1:3;6) type C-1 (with 20 mm graded aggregate) 50 mm thick precast RCC (1:2:4) cover slable (re- inforced with 8 mm dia TMT bar @ 15 cm both ways and suitable handle made of 10 mm dia ) including necessary earth work in excavation ,returning filling and removal of surplus earth upto a distance exceeding 50 mtr etc all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed by Engr-in-Charge.
M & L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth strip of size 25 mm x 4 mm connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth strip will be protected by 40 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'Medium grade', GI wire mess funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I.
M&L for painting of PCC HT poles in Zebra pattern 30 cm wide, with synthetic enamelled paint in black and red colour up to 1.2 meter height from pedestal ,including writing in 80 mm wide letters /numbers in both side of pole MES,HT and pole No all as directed by Engr-in-Charge.
M&L for painting of steel structure ,cross arms ,bracings, supports, clamps and back plates (all metalic parts) on PCC/steel tubular pole complete with two coats of aluminium paint incl preparation of old painted steel surfaces incl painting of pole coping with black paint all as directed at site.
Dismantling of broken stay assembly from various location any size and stay rod complete all as specified and directed at site. Note : rates includes demolition of concrete and making good.
M&L for stay assembly complete comprising of mS galvanised stay plate 30 cm x 30 cm x 6 mm , MS galvanised stay rod 20 mm dia with nut,215 cm long,MS galvanised stay bow 40 cm long with 02 No galvanised thimbles with and including all fittings as shwon in electrical plate No 1 of SSr Part-I (loop type insulator,stay clamps,excavation and concrete measured separately).
M&L for re-stretching ACSR conductor on HT pole having (3) conductors with earthing GI wire or guardning wire etc complete in any type OH line including jumpers using new conductor & binding wire complete all as specified and as directed by Engr-in-Charge,.
M&L for surface dressing n.exc 15 cm deep in soft/loose soil
M&L for graded coarse aggregate 40 mm including spreading ,leveling at various location pole structure,transformer area etc complete all as specified and as directed by EIC.
Supply and replace in repairs ACSR conductor duly insulated with HT heat shrink sleeve tubes for jumper/incoming/dropout/GOD complete all as specified and as directed by Engr-in-Charge.
M&L for maintenance of HT 11 KV GOD horizontal/vertical type in position at locations by greasing all moving parts, cleaning contacts,making operating handle functional and tightening all connections incoming/ outgoing all as specified.
Supply and replacement in repairs HT 11 kV dropout insulators set (Set of three) in position at loaction
S&F disc type porcelain,vitreous,white,brown or green 145 mm height and 225 mm dia ball and socket type,sngle disc assembly for tension with tension clamp for conductor working pressure 11000 volts grade complete.
S&F insulator pin type porcelain,vitreous,white,brown or green 150 mm height and 150 mm dia including one galvanised mild steel spindle,two galvanised washers and one galvanised iron nuts for conductor working pressure 11000 volts grade complete
S&F galvanised stay strand 7/8 SWG laid for stay of poles complete.
M&L loop porcelain,vitreous white, brown or green insulator with over all dimension of 90 mm x 140 mm, clearence of whole 25.5 mm complete
M&L galvanised steel wire 4 mm dia as earth conductor run along the over head line duly binded with metallic cross arms and armour of cable at the end pole complete.
Material and Labour for disconnecting defective transformer 11 KV/0.433 KV of capacity 40 KVA to 63 KVA on foundation or two pole structure and transportation for repair to workshop or factory,dismantling the transformer for repair and reassembling the same after repairs and renewal of unserviceable parts,dentingwelding etc and spray painting with two coats of synthetic enamelled paint (grey paint) including preparation of surface,marking of MES No with white paint of suitable size and transportation from workshop or factory to site and re-installed on plateform on two pole structure, commissioning and testing of transformer up to entire satisfaction of Engr-in-Charge.Note : Spare parts/transformer oil/rewinding will be measured and paid separately and supply & fixing only.
All as per item No 55 above here in before but size of transformer 75 KVA to 160 KVA
M&L in repair, synthetic rubberised gasket for top cover LT terminal box LV/HV bushing,washers,spindle etc of transformer 11 KV/0.433 KV, 40 KVA to 160 KVA capacity complete all as specified & directed by Engr-in-Charge.
M&L for taking out unserviceable complete coil on limb and HT/LT winding of transformer 11 Kv/0.433 KV capacity 40 KVA to 160KVA with suitable size/existing gauge supper enamelled copper winding wire insulated with necessary insulating material complete all as specified & directed by Engr-in-Charge.insulators of transformer 40 KVA to 160 KVA capacity including brass bush rod with nuts & washers complete all as specified & directed by Enginner -in-Charge.
M&L for replacement of unserviceable HT bushes insulators of transformer 40 KVA to 160 KVA capacity including brass bush rod with nuts & washers complete all as specified & directed by Enginner -in-Charge.
M&L for renewal of unserviceable LT brass spindle for transformer 11/0.433 KV capacity 40 KVA to 160 KVA complete all as specified & directed by Engr-in-Charge.
M&L for renewal of unserviceable breather assembly with new silica gel for transformer 11/0.433 KV capacity 40 KVA to 160 KVA complete all as specified & directed by Engineer-in-Charge.
Topping up / refilling of transformer oil of dielectric strength 50 KV minimum for voltage stabiliser / transformer complete all as specified & directed by Engineer-in-charge.NOTE: Transformer oil will be issued under Sch 'B' from MES Store yard for free for top up.
Disconnecting transformer from load of any make any size and any capacity ,draining out tranformer oil and and regular filtration at location at location in position at site (on pole/plateform) filteration upto required dielectric strength with the help and drying plant by mechanical machines of suitable capacity to achive including testing of dielectric strength and alkali all directed by Engr-in-Charge.
Material and Labour for disconnecting defective voltage stabilizer 440 volts of cap 40 KVA to 75 KVA on foundation and transportation for repair to workshop or factory,dismantling the voltage stabilizer for repair and ressembling the same after repairs and renewal of unserviceable parts, denting ,welding etc and spray painting with two coats of synthetic enamelled paint (grey paint) including preparation of surface, marking of MES No with white paint of suitable size and transporatation from workshop or factory to site and re-installed on plateform,commissioning and testing of voltage stabilizer upto entire satisfaction of Engr-in-Charge.Note : Spare parts/voltage stabilizer oil/rewinding will be measured and paid separately and supply & fixing only.
Material and Labour for taking out unserviceable complete dimmer of voltage stabilizer 440 volts capacity 40-75 kVA with replacement of as per existing size and capacity with copper winding and necessary insulating material complete all as specified & directed by Engr-in-Charge.
S&F in repair servo motor suitable for 40 KVA to 75 KVA voltage stabilizer incl removing old unsv servo motor all as specified and directed by Engr-in-Charge.
Taking down old rucsted / broken notice board complete all as specified.
Dismantling earth wire or copper conductor service feeder or distribution span etc
Dismantling of insulators any type , any size complete all as specified and directed at site.
Dismantling of old unsv lighting arresters complete all as specified and directed at site.
Repair the existing panel board outdoor/indoor, fixed to the wall/plateform/pole etc by replacement of old unsv items i.e.MCCB/MCB/voltmeter/ammeter/PT/CT/indicators etc from panel and making new electric connections with multistranded copper cable of suitable size with lugs,welding of broken portion of panel, providing of new hinges after remoing old broken hinges,handle including painting of outdoor /indoor any type any size and any make of panel with one coat of synthetic enamel paint of approved colour to external surface of panels complete all as directed by Engr-in-Charge. Note : MCCB/MCB/voltmeter/ampmeter/PT/CT/indicators etc will be measured and paid separately with S&F under relevent items as supply only.
Taking down MCCB 63 Amps to 400 amps and making the good to the disturbed surface complete all as specified and as directed.
S&F for MCCB 200 amps,415 volts AC with breaking capacity 36 KA ,four pole complete all as specified and directed at site.
S&F for MCCB 400 amps,415 volts AC with breaking capacity 36 KA ,four pole complete all as specified and directed at site.
S&F for MCCB 250 amps,415 volts AC with breaking capacity 36 KA ,four pole complete all as specified and directed at site.
S&F for MCCB 100 amps,415 volts AC with breaking capacity 16 KA ,four pole complete all as specified and directed at site.
S&F for MCCB 63 amps,415 volts AC with breaking capacity 16 KA ,four pole complete all as specified and directed at site.
S&F for MCB four pole100 amps,415 volts , 10 KA 'C' curve complete all as specified and directed at site.
S&F in repair only LT current transformer of any ratio complete all as specified and directed at site.
S&F in repair RYB phase indicators complete all as specified and directed at site.
S&F for MCB TP 63 amps,415 volts , 10 KA 'C' curve complete all as specified and directed at site.
S&F for installation of on load change over switch of capacity 100 amps AC 415 volt 4 pole side handle operated with sheet steel enclosure including addn altn /modification work etc complete all as per directed by Engr-in-Charge.
S&F for installation of change over switch of capacity 200 amps AC 415 volt 4 side handle operated with sheet steel enclosure ncluding addn altn /modification work etc complete all as per directed by Engr-in-Charge.
S&F for installation of change over switch of capacity 250 amps AC 415 volt 4 pole front operated with sheet steel enclosure ncluding addn altn /modification work etc complete all as per directed by Engr-in-Charge.
Taking down the old unserviceable LT UG cable of size 10 sqmm x 2 core with aluminium lug s etc complete all as specified and directed at site. Note : Excavation and earth work, sand, pipe and stone patti will be measured and paid separately.
All as per ser item No 87 above here in before but size of 16 sqmm x 4 core
All as per ser item No 87 above here in before but size of 25 sqmm x 3.5 core
All as per ser item No 87 above here in before but size of 50 sqmm x 3.5 core
All as per ser item No 87 above here in before but size of 70 sqmm x 3.5 core
All as per ser item No 87 above here in before but size of 95 sqmm x 3.5 core
M&L for XLPE insulate, armoured, heavy duty electric cable, aluminium conductor, 1100 volts grade of cross sectional area 10 sqmm x 2 core connected to both side connection with suitable size of aluminium lugs complete all as specified and directed by the Engr-in-chrge. Note : (i) Excavation and earth work will be measured and paid separately.
All as per ser item No 93 above here in before but size of cable 16 sqmm x 4 core
All as per ser item No 93 above here in before but size of cable 25 sqmm x 3.5 core
All as per ser item No 93 above here in before but size of cable 50 sqmm x 3.5 core
All as per ser item No 93 above here in before but size of cable 70 sqmm x 3.5 core
All as per ser item No 93 above here in before but size of cable 95 sqmm x 3.5 core
S& F aluminium sector lugs- long barrel of size up to 25 sqmm complete all as specified and directed by Engr-in-Charge.
S& F aluminium sector lugs- long barrel of size 50 sqmm complete all as specified and directed by Engr-in-Charge.
S& F aluminium sector lugs- long barrel of size 70 sqmm complete all as specified and directed by Engr-in-Charge.
S& F aluminium sector lugs- long barrel of size 95 sqmm complete all as specified and directed by Engr-in-Charge.
M & L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth strip of size 25 mm x 4 mm connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth strip will be protected by 40 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'Medium grade', GI wire mess funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I.
S&F galvanised strip 25 x 4 mm with saddles and fixing screw etc for roof conductor and down conductor above ground complete all as specified & directed by Engr-in-Charge.
S&F galvanised strip 32 x 6 mm with saddles and fixing screw etc for roof conductor and down conductor above ground complete all as specified & directed by Engr-in-Charge.
S&F air termination,single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified & directed by Engr-in-Charge.
Taking down the old unsv/corrosive light grade GI Pipe of size 80 mm dia complete all as specified and directed at site.
All as per ser item No 107 here in before but size of pipe 50 mm dia
M&L for GI tubing light grade of sie 80 mm dia for protection of cable in trenches /on pole all as directed by Engr-in-Charge.
All as per ser item No 109 here in before but size of pipe 50 mm dia
M&L for prestressed cement concrete pole 9 mtr long,102 mm x172 mm at top and 102 mm x 279 mm at bottom (or nearest higher size as approved by State electricity board),Class -10 conforming to IS -1678-19998 including dismantling concrete poles/struts, any size complete all as specified & directed by Engr-in-Charge.
Supply and fix insulator,loop type,porcelain/vitreous,white or brown with overall dimensions of 65 x 90 mm clearance of hole 16 mm complete all as specified
M&L for galvanised stay strand 7/2.24 mm size complete all as specified & directed by Engr-in-Charge
Supply and fix LT 1100 V pin type porcelain/vitreous china,white,brown, or green insulator height 100 mm,65 mm dia,1100 v grade incl one galvanised mild steel spindle , two galvanised iron washer and one GI nut complete (ISI marked )
Supply and fix LT 1100 v shackle type porcelain/vitreous white,75 mm height 90 mm dia incl one galvanised mild steel spindle,washer insulator bolt & GI nut complete (ISI marked)
Supply and fix in replacement of power capacitor 440 volts,heavy duty 3 Kvr with suitable cable connection Make : TDK/Epcos/Havells/L&T
Supply and fix in replacement of power capacitor 440 volts,heavy duty 5 Kvr with suitable cable connection Make : TDK/Epcos/Havells/L&T
Supply and fix in replacement of power capacitor 440 volts,heavy duty 10 Kvr with suitable cable connection Make : TDK/Epcos/Havells/L&T
S&F spacer 2 wire system in LT over head line in position /location
S&F spacer 4 wire system in LT over head line in position /location
M&L for re-stretching ACSR conductor on LT pole having (4+2) conductors of any type including using new binding wire
M&L for re-stretching ACSR conductor on LT pole having (4) conductors of any type including using new binding wire
M&L for re-stretching ACSR conductor on LT pole having (2) conductors of any type including using new binding wire
Supplying Fixing/jointing of heat shrink type cable jointing kit for outdoor termination suitable for 11 KV grade 3 core 50 to 95 sqmm including testing including taking down unsv cable jointing kit complete all as specified and directed by Engr-in-Charge
All as per item no 124 here in before but size of jointing kit 120 to 185 sqmm
Supply,installation,testing and commissioning CPRI approved make wall mounted cubical canopy type out door LT panel dust and vermin proof made out of CRCA sheet 3 mm thick steel sheet and 40 x40 x 6 mm angle iron section with hinged cubical doors front side openable having locking arrangement and all acessories complete as per IE rule with powder coated paint over one coat of red oxide primer complete with required fixing arrangement etc and all accessories incl necessary PCC 1:3:6 type C2 as in foundation including taking down old unsv LT feeder piller box all as directed comprising of the following :-
Taking down of old unsg GI earth strip of size 25 x 4 mm / 32 x 6 mm
Taking down old unsv change over switch size up to 250 amps 3/ 4 pole complete all as specified and directed at site.
Taking down old unsv MCB TP / four pole 63 amps/100 amps complete all as specified and directed at site.
star electricals
ALPHA ENGINEERING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .