Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC | ₹8.4 L Quoted ₹9.8 L | L1 | Accepted-AOC lowest |
| 2 | L2₹11.6 L+₹1.8 L (18.3%)Rejected-Finance | ₹11.6 L+₹1.8 L (18.3%) | L2 | Rejected-Finance other than lowest |
| 3 | L3₹12.1 L+₹2.4 L (24.1%)Rejected-Finance | ₹12.1 L+₹2.4 L (24.1%) | L3 | Rejected-Finance other than lowest |
| 4 | L4₹12.2 L+₹2.5 L (25.1%)Rejected-Finance | ₹12.2 L+₹2.5 L (25.1%) | L4 | Rejected-Finance other than lowest |
| 5 | L5₹12.3 L+₹2.6 L (26.3%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹12.3 L+₹2.6 L (26.3%) | L5 | Rejected-Finance other than lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
25 Dec 2024, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001 (Punjab)
Repair and comprehensive maint to LT electric supply, panels, street lights/security lights and connected E/M works allied items of work at CG Complex, Doraha and Phillaur under GE Ludhiana.
2024_MES_684089_1
GE/LDH-48/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
CG COMPLEX, DORAHA AND PHILLAUR
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹30,000
Yes
13 Jan 2025
16 Nov 2024
27 Dec 2024
16 Nov 2024
25 Dec 2024
8 Dec 2024
16 Nov 2024 - 7 Dec 2024
Amount
Taking down existing street light fittings of any type/size/capacity fixed in any position i.e. on wall/ pole/ watch tower fixing the fitting in its original position after repairs complete all as specified and directed . (Note:-Spares shall be measured and paid separately under item No 06 & 07.)
S & F in replacement LED street light luminaire of 60 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed
S & F in replacement LED street light luminaire of 90 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed
S & F LED flood light fitting of 120 watt 230 V AC outdoor type with thermal management in multiple optics and euipped with IP66 protection,with impact and corrosion resistant complete with driver and lamp complete all as specified and directed Note : Ser No 02 to 04- Taking down and refixing of fittings shall be included in the respective items.
Supply and fixing 1100 volt grade heavy duty single core cable PVC insulated PVC sheathed with stranded copper conductor wire FRLS of size 2 x 1.5 Sqmm and 1 x 1.5 sqmm for connection purpose, ISI marked drawing through and including 20mm dia PVC conduit complete all as specified and directed
Supply and fixing in replacement of driver suitable for any type of street light 45W/60W/90W complete all as specified and directed
Supply and fixing in replacement of Surge protection device suitable for any type of street light 20watt/45W complete all as specified and directed.
S&F in replacement of Polycarbonate ASTA CPRI approved OEM made street light junction box .The junction box IP 66 weather proof & enclousers for outdoor installation with knockouts for cable entry of size 10 sqmm etc complete all as specified and directed.
M & L for in replacement TPN MCB 40 to 100 Amps, 4 pole 415 Volts, 50 Hz, having rupturing capacity 10 KA of rating complete all as specified and directed.
M & L for in replacement MCB SPN 32 Amps, 240 Volts, 50 Hz, having rupturing capacity 10 KA of rating complete all as specified and directed.
M&L MCB SP 6 to 32 Amps, 10 KA, C-curve complete all as specified and directed.
M&L painting of cement concrete poles with junction box,clamp and bracket any type of size externally above foundation with two coats of synthetic enamel paint over a coat of primer after scraping/cleaning well the existing surface with black and white strips 30cm each up to 1.5 metre height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80mm high letters over 150mm x 230mm yellow base complete all as specified and directed .
M&L painting of LT Steel tubular pole with junction box,clamp and bracket any type of size externally above foundation with two coat of aluminium paint over a coat of red oxide primer after scraping/cleaning well the existing surface incl painting of bottom with black white or yellow color strip 30cm each upto 1.5 mtr high from top of PCC foundation block and numbring of pole with synthetic enamel paint white in 80mm high letter over 150mmx230mm yellow base complete all as specified and directed.
Supply and fixing in replacement of PVC spacer/separators on LT OH line conductor for 4 wire including necessary nuts, bolts and fixing properly on ACSR conductor complete all as specified and directed
Supply and fixing in replacement,bracket made out of 40 mm bore galvanized steel tubing medium grade 1.5 m long including bending if required as directed, 02 Nos clamps made out of MS flat iron 40X4mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete all as specified and directed. (Rates quoted by the contractor shall deemed to include for nut and bolts).
Supply only insulation LT tape size normal width 20mm length 25 metre Thickness 0.125mm complete all as specified and directed
M& L in replacement for cross arms, bracings, supports clamps and back plate fabricated from steel structural including nuts,bolts washers welding,bending cold or hot,drilling holes and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed including taking down existing.
M & L for loop type insulator, porcelain vitreous white or brown, with overall dimensions of 65mm x 90mm, clearance of hole 16mm complete all as specified and directed including taking down existing.
M& L for pin type porcelain vitreous, white, brown or green insulators including one galvanized mild steel spindle two galvanized iron washers and one galvanised iron nuts and 65 mm dia , 100mm herght for 1100 volt grade complete all as specified and directed including taking down existing.
M & L shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulators bolts, washers and nuts complete 100 mm height and 115 mm dia for 1100 volts complete all as specified and directed including taking down existing.
S & F in replacement ACSR conductor steel, reinforced on over head lines fixed on insulators, binding with and including binding wire 14 swg complete all as specified and directed including taking down existing. ( for payment purposes, the weight of binding wire shall not be considered).
Supplying and drawing and fixing in replacement of continous GI earth wire/guard cradles 4 mm dia including GI binding wire 1.63mm on LT poles complete all as specified and directed including taking down existing.
M & L in replacement stay assembly comprising of GI stay bow 14 mm dia, 40 cm long ( over all) galvanised stay rod 16 mm dia 100 cm long with threaded ends GI nuts, bolts, washers, stay plate 23 cm x23 cm x 6 mm thick, 2 Nos of thimbles, MS clamps made out of 50 mm x 6 mm flat iron complete including stay wire 7/8 SWG complete all assprcified and directed including necessary excavation and earth work and PCC 1:3:6 all as shown in electrical plat No.1 of SSR-2009 Part-I (PCC and earth work, loop type insulator, stay clamps shall be measured and paid for separately under the respective item of schedule) including taking down existing old unsv stay assembly complete all as specified and directed
M & L for PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate for coping of poles & LT panels complete all as specified and directed
Supply, laying, jointing, testing and commissioning in replacement of cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed by means of MS saddles on or fixed on poles including connection with proper lugs for the following size including taking out old etc complete all as specified and directed including taking out existing and removing from site (Excavation and earth work shall be measured and paid for separately)
10 Sqmm 2 Core
25 Sqmm 3.5 Core
35 Sqmm 3.5 Core
50 Sqmm 3.5 Core
95 Sqmm 3.5 Core
120 Sqmm 3.5 Core
150 Sqmm 3.5 Core
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for taking out of unserviceable under ground cable complete all as specified and directed
Material and labour for sand cushioing with a layer of fine sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed . Notes-:(i) Excavation and earth work to be measured and paid for separately. (ii)Thickness of 18cms after punning shall be considered for payment.
Supplying and laying bricks common burnt clay building bricks sub class B including removing of old bricks complete all as specified and directed
All as per item ser No 28 above but except bricks complete all as specified and directed.
Returning, filling in, any type of soil and spreading, in layers not exceeding 25 cm thick complete all as specified and directed
Removal of surplus soil (any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed & complete all as specified and directed
Supply and fix of aluminium Lugs suitable for 16 to 35 Sqmm 1100Volts including taking down old unserviceable lugs, complete all as specified and directed
Supply and fix of aluminium Lugs suitable for 70 to 185 Sqmm 1100 Volts including taking down old unserviceable lugs, complete all as specified and directed
Supply and fixing in replacement GI pipe light grade 80 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah complete all as specified and directed .
Material & labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 32 x 6mm connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth strip connected to test point and protected by galvanized iron light grade 50mm bore and GI pipe 20mm bore light grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate and RCC cover in 1:2:4 and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed. Notes : (i) Outer edge of earth pit will be 1.5m away from the outer edge of PCC chamber. (ii) Water pipe shall be provided in slanting position.
Supply and fixing in replacemnt digital voltmeter (0-500 Volts ) 96x96mm square type including taking out old unserviceable voltmeter complete all as specified and directed
Supply and fixing in replacement digital Amps meter (0-600 Amps ) 96x96mm square type including taking out old unserviceable seperator complete all as specified and directed
Material and labour for replacement of indicator lamp in red, yellow and blue colour with lamp holder multi LED type complete including wiring with copper conductor cable of suitable size complete all as specified and directed
Supply and fixing in replacement of MCCB of current rating 400 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable TM type release including taking down old unserviceable MCCBs complete all as specified and directed
Supply and fixing in replacement of MCCB of current rating 315/320 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable type release including taking down old unserviceable MCCBs complete all as specified and directed
Supply and fixing in replacement of MCCB of current rating 250 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed
Supply and fixing in replacement of MCCB of current rating 200 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed
Supply and fixing in replacement of MCCB of current rating 160 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed
Supply and fixing in replacement of MCCB of current rating 125 Amps, 4 pole, 415 volts AC, 16 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed
Supply and fixing in replacement of MCCB of current rating 100 Amps, 4 pole, 415 volts AC, 16 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed
Supply and fixing in replacement of MCCB of current rating 63 Amps, 4 pole, 415 volts AC, 16 KA rupturing capacity with adjustable thermal type release including taking down old unserviceable MCCBs complete all as specified and directed
S&F for jointing and testing LT (heat shrinkable) cable end termination joint suitable for LT cable 11000 volts grade 16 Sqmm to 35 Sqmm complete all as specified and directed
S&F for jointing and testing LT straight through (heat shrinkable) cable joint suitable for LT cable 11000 volts grade 50 Sqmm to 150 Sqmm complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technique and necessary T&P for passing of LT/HT cables. complete all as specified and directed
M & L for stone aggregate of size 40mm to 80 mm spreading over as per requirement in the sub station areas/2 Pole/4 Pole structure including proper levelling complete all as specified and directed
RAJINDER ELECTRICAL WORKS (BID ID -3191915)
Dhani Builders (BID ID -3191938)
JASSI TRADERS (BID ID -3192258)
SUN MANN ENGINEERS (BID ID -3192291)
HG construction (BID ID -3190456)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .