| 1 | L-1₹11.3 LAccepted-AOC | L-1 | Accepted-AOC Lowest-1 | |
| 2 | L-2₹11.9 L+₹55,316 (4.89%)Rejected-Finance LAXMI BAZAER TEHSIL JOGINDERNAGAR DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | L-2 | Rejected-Finance Lowest-2 |
Tender Value
₹8.5 L
EMD Value
₹17,100
Closing Date
20 Aug 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE
EXECUTIVE ENGINEER JAL SHAKTI DIVISION BAGGI
AS PER BOQ
2021_HPIPH_51151_1
EE-JSD-BAGGI/2021- 15422-72 DATED 11/8/2021
Open Tender
Civil Works
Item Rate
180 days
BAGGI
AS PER NIT
8 documents required · 8 mandatory
₹250
EE BAGGI
₹17,100
Yes
31 Dec 2022
12 Aug 2021
21 Aug 2021
12 Aug 2021
20 Aug 2021
12 Aug 2021
120 days
Amount
Supply of Horizontal spindle, horizontal split casing Single/Multistage centrifugal pumps of standard make such as KSB/Mather & platt/Jyoti/Kirloskar/WASP conforming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 50 ppm. with impellers, casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirloskar/NGEF/Crompton/Siemen/Jyoti slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below.
A) SITE CONDITIONS:- i)Location of Site -About 28 Km from Baggi to Leda.(Near village Leda) ii)The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mt. is 800 Mtrs. iii)Humidity-Weather generally remains humid during monsoon Season iv)Nature of atmosphere-As normally encountered in Shivalik Range. v)Detail of quality of water -Raw water. vi)Water free from sand or not-Yes. vii)Water corosive or not-Not viii)Turbidity (if any)-CLEAR COLD WATER ix)NPSH available-8.994 Mts. x)Any other information or requirement. B) OPERATING CONDITIONS:- i)Type of current-AC three/single phase. ii) Operating frequency-50 HZ iii)Rated voltage-400 (+/-) 10% volts. iv)System of earthing if any to be adopted. -Double loop earthing as per BIS 3043-1987 latest with upto date ammendments. v)No. of working hours per day -8 hours. vi)Speed of revolution in RPM. -To be quoted by tenderer. vii)Direction of rotation-To be quoted by tenderer. viii) The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service. -25 Degree Centigrade.
C)MOTOR :- i) Ref to BIS code. -BIS 325- 1978 read with BIS 900-1992 (latest) with upto date ammendments. ii)Type of enclosure of motor -SPDP (as per BIS 4691-1985 (Latest) iii)Type of duty -Continuous. iv)Mechanical out put in KW. -suitable for driving centrifugal pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. v)Class of insulation-Class- B. vi)Max. permissible temp. rise of motor reqd. if different from given in B (viii) above. - vii)Particulars of test reqd. & wheire they are to be conducted. -As per terms & conditions. viii)Particulars as to whether voltage limiting device will be employed. -ATS/star delta starter oil immersed fully automatic to be installed between bus bar chamber & motor. -Shunt capacitor is also proposed to be installed for improving the power factor at site. NOTE :- Star delta starter upto 37.5 KW. ATS between 37.5 KW to 50 KW & Stator rotor starter with slip ring motor beyond 50 KW. ix)Motor whether squirrel cage or slipring. Squirrel cage/slipring Note :- Squirrel cage upto 65HP and slipring above 65 HP. x)Details of shaft extension reqd. -Just sufficient to provide direct drive by flexible coupling to pump. xi)Type of slip ring gear whether continously rated or for starting puposes only & whether to be fitted with brush lifting or short circuiting arrangements or both if interlocks are required. -Continously rated for Squirrel cage/ slipring motor. xii)Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit. -Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current xiii) Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No. of starts during a specified period.-To work the pump offered. xiv)Where possible fault capacity of the system to which the motor is connected. -The motor should be able to withstand initial current of 2.5times the rated current for two minutes without suffering damages or permanent defomations.
PUMP (BIS 1520-1980) read with BIS 9137-1978 both latest with upto date ammendemnts. a)Nos of pumps reqd. -1 No. working pumps & 1 No. stand bye b)Spare parts required.-For two years normal maintenance as recommended by manufacturer. c)Optional fittings reqd. -Air cock for exahausting air from each stage E)PUMP OPERATING CONDITIONS :- i)Capacity-5.08 LPS ii)Total head in Mts. -179.67 mtrs , If total head is not known then follwing details be provided :- i) Static Head-143.00 Mts. ii) Minimum Depth of Water ---- mts. iii) Variation in Water Level ---- mts. iv) Ground Level to Max. water leve - l1470.00 mts. v) Ground Level to Delivery Point 1612.00 mts. vi) Pressure in the suction tank -----Kg/cmΛ² vii) Pressure in the Delivery tank -----Kg/cmΛ² iii) Length of Rising main -1200.00 mts. iv)Dia of R/main-80 mm v)Drive arrangement-Direct through flexible coupling on a common base plate. vi)Drive type-Electric driven. vii)NPSH reqd. - To be quoted by the tenderer.viii)Limits of total head in which the pump is reqd. to operate. -(-) 25% to (+) 10% of total head. ix) Suction/delivery size of pump. - To be specified by the tenderer. x)Efficiency of pump at -To be specified by the tenderer. Material of construction.a) b) c) To be specified by the tenderer - (Manufacturer certificate to be appended).
Suply of suitable oil immeresd Star Delta Starter/ATS/stator Rotor Starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release with initial oil filling. Note:- Star- delta - starter upto 37.5 KW. ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50KW.
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltge difference.
Change over switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable cacpacity.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52 Kg/cm^² NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirlosker/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pas arrangement & size equal to delivery of Pump for withstanding nominal seat pressure of 52Kg/cm^² NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Glad/Bhel/Leader of suitable size Cast Iron/Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 52 Kg/cm^² NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Glad/BHEL/Leader/of reputed make of suitable size cast iron flanged sluice valve confirming to IS 780, size equal to dia of suction pipe PN 1 Provided with hand wheel/Cast iron Cap.
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast iron flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with upto date ammendments.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) - 1988 or latest with upto date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phase) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipe or trenches under floor. The type size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Providing laying suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part-I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipes, solder, nuts & bolts, cable gland sets. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
Providing/Laying suction, delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure indicated in item No. 1e(ii). Note :- Actual laying to be done as per final drawings to be approved by the Engineer-in-Charge.
Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments from S.No. 1 to 4, 6 & 8 i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Excavation in foundation,trenches up to all depths in all classification of earth work such as pick work,jumper work,saturated soil including bailing and pumping out water, blasting soft/hard rock or chiseling soft/hard rock where blasting is prohibited in all lifts including trimming & dressing of sides, levelling of beds to correct grade i/c shoring/ strutting,planking, timbering & dewatering wherever required, stacking the useable of unuseable material/ soil separately & after excavated soil clear from the edge of excavation returning the excavated soil after laying jointing testing of pipes in trenches in 15 Cm layers including consolidating of each deposited layer by ramming & watering & then disposing of all surplus Excavated soil/unusable material as directed with in all leads & lifts including restoration of unmetalled surfaces to its original condition & including cost of diversion for traffic,night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per the entire satisfaction & directions of Engineer- in- charge.
Laying, jointing and testing in trenches (to be levelled, to grades) GI flanged pipes of following diameter, class & wall thickness and IS specification capable to with stand the required hydraulic test pressure as per IS Code in a random length of 4 mtrs. to 7 mtrs. with bevelled ends and jointed with flange tables mentioned below conforming to IS 6392-1971 (latest with upto date ammendments). The welding of flanges to be done on both faces in double layer to make the joint leak proof according to relevant BIS standards and detailed specifications. The pipe including nuts & bolts of required sizes, 3mm thick compressed asbestos fiber jointing gasket or synthetic rubber gasket confirming to relevant BIS codes (including all kinds of flanged short pieces, bends, tees & other specials etc made from parent tubes & provided and welded with flanges of tables as applicable for the particular reach as per site conditions, including cutting, welding, flushing,cleaning & hydraulic testing of pipe as per directions of Engineer-in-charge. (GI Pipes will be supplied by the department free of cost).
80mm dia, RD 0 to 200 = 200 mtr. GI IS 1239 (M), wall thickness 4.00 flange table-28
80mm dia, RD 200 to 900 = 700 mtr., GI IS 1239 (M), wall thickness 4.00 flange table-17
80mm dia, RD 900 to 1200 = 300 mtr., GI IS 1239 (M), wall thickness 4.00 flange table-5
Laying, jointing & testing in trenches (to be levelled to grades) IS marked GI pipes (Medium grade) of following dia confirming to IS 1239-1991 (part-II) (latest with upto date amendments) including butt welding of pipe ends to make water tight joint including carriage of material up to all leads and lifts. This work also includes fabrication of short pieces, bends tees and other specials etc. from parent tubes with butt welding in three layesrs as applicable for the particular reach & of technical specification as per site conditions including flushing, cleaning & hydraulic testing complete to the best satisfaction of Engineer- in- charge. The laying of pipe shall confirm to IS : 5822-1994 and as per CPHEEO manual. The rates also includes the carriage of GMS tubes from the JSV divisional store Baggi to the site of work. butt welding of joints , fabrication of short pieces , bends , tees & other specials etc. from parent tubes, flushing , cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts ( Earth work in trenches will be measured and paid for separately).
80mm dia, RD 0 to 1200 = 1200 mtr., GI IS 1239 (M), wall thickness 4.00
Naik Electrical Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .