Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹3.1 L+₹72,000 (30.1%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹10.5 L+₹8.1 L (339.3%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹3.3 L
EMD Value
₹6,640
Closing Date
12 Jul 2023, 6:00 pmClosed
Chief Engineer Pathankot Zone
Chief Engineer Pathankot Zone
CONSULTANCY SERVICES FOR PROVN OF SEWAGE TREATMENT PLANT STP UNDER GE SAMBA
2023_MES_583413_3
CA NO CEPZ-32/2022-23
Open Tender
Job Works
Item Rate
90 days
GE Samba
As per NIT/ Tender Documents
7 documents required · 7 mandatory
₹300
GE Samba
₹6,640
11 Sept 2023
13 Jun 2023
19 Jul 2023
13 Jun 2023
12 Jul 2023
28 Jun 2023
Amount
Consultancy services for preparation and submission of Detailed Project Report (DPR) for Provn of Sewage Treatment Plant and upgradation of sewer line at Samba (UT J&K) complete all as specified including following brief scope of work as eloborated under serial No-1.01 to 1.08 here-in-after:-
Detailed topographical survey of area with Grid size of 5 meter x 5 meter (Approx 100 Acre) as directed by GE/Engineer in charge. Topography map to show/ superimpose the existing ground features like buildings, roads, Nallahas, rivers and other similar permanent features over the different locations / areas of Samba Military station for the areas as shown in the layout plan (available at the office of GE Samba) including prepration of contour layout plan to show/superimposed contours @ 0.5 mtr. interval. Contours should be linked to nearest Survey of India permanent bench marks.
Preparation of most economical and efficient sewage network, system including hydraulic design and calculations for quantity of sewage, storm run off, automatic flushing tanks (AFT) (if required), manholes etc as required to complete the project including supply of requisite data and documents as required vide srl clause no 14 (Phase-II) (Stage-I to Stage-III) of appendix 'A' of consultancy aggreement..
Preparation of archtectural and structural drawings and design of pumping station including lift wells, sump wells , automatic flusing tanks (AFT) (if required), manhole etc as required to complete the work.
Hydraulic design of MBBR including Comparison with other available technologies based STP (Sewage treatment Plant) of capacity approximate equal to 200 KLD (subject to finalzation of ground data / scheme) and preparation of general arrangement drawings as per scheme approved by Accepting Officer alongwith structural drawings and redistribution of treated sewage for gardening and arboriculture. The effluent quality of STP at outlet point should comply with the limits prescribed by State / UT Pollution Control Board for arboriculture purpose.
Electro Mechanical design of pumping station and sewage treatment plant including SCADA automation system
Preparation and submission of Detailed Project Report (DPR) and detailed estimates of all structures (buildings, STP, electric & mechanical parts) and sewage network including lift wells, sump wells, automatic flushing tank (AFT), (if required),manholes etc as requried to complete the project based on the SSR-2020 (Rates) / prevailing market rate /derived rate as the case may be. Notes:- (a) The design and technology proposed for STP shall comply the norms of treated effluent parameters within the limits prescribed by State / UT Pollution Control Board (SPCB) for arboriculture purpose. (b) The scheme shall be designed by the consultant and submitted for scrutiny and final approval by the HQ Chief Engineer Pathankot Zone.(c) In any case , the effluent shall not be discharged into natural streams /Nallah/canal/natural water bodies as per State / UT Pollution Control Board (SPCB) norms.
Vetting of scheme from Govt Engineering College like IIT/NIT.
Common Notes for All items of BOQ :- (i) All components and entire scheme shall be designed as per CPHEEO (Central Public Health and Environmental Engineering Organisation) actual and/or relevant standards of latest edition as applicable and actual ground data shall be collected by the consultant on ground and/or from MES and/or other departments as the case may be. (ii) All misc structures like retaining walls, cross over structures, vents etc shall be planned and designed as per site requirement. (iii) All structures shall be designed for seismic Zone-IV as per IS-1893 and grade of concrete shall be not less than M-30 with exposure conditions as per IS-456. (iv) Soft copy of Hydraulic Design calculations for each sewer line and structure shall be submitted on the MS excel format alongwith Six sets of hard copies. (v) Structural design output/calculations shall be submitted in PDF fromat alongwith soft copy of input files on the STAAD fromat/MS excel sheet as applicable. (vi) Consultants are advised to visit site before quoting the rates and all the above mentioned aspects are deemed to be included in the quoted rates for the said Job. No claim what so ever shall be entertained at the belated stage on this account. The area falls under GE Samba
(vii) No lodging, boarding and transportation shall be provided by the department to visit the site during execution of main project as well as while performing the consultancy work and at the time of prepration of tender by the department for main project which will be based on the DPR provided by the consultant under this contract. (viii) Consultant shall visit site at least once in a quarter and total not less than 5 visit as decided by the GE during execution of work and provide technical assitance for implimentation of design and drwaings in execution and give suggestion/revision to drgs/ design if required in, due to any reasons. (ix) The Consultant shall also be required to visit office of Chief Engineer Pathankot Zone and /or provide necessary clarifications when ever required during prepration and finalizing the tender/contract for the main project by the Department. The consultant quoted rates in the BOQ shall be inclusive of all such enxpenses to be borne by the consultant. (x) The consultant for NON compliance of any of the contractual obligations to the best satisfaction of the accepting officer as stipulated in these notes No (vii) and (viii) above shall be penlized as per relevent clause/ paras of the contract.
Indian climate control
INDUS WATERWAYS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .