Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC 46 6 NATABAR PAUL ROAD HOWRAH | HOWRAH | HOWRAH | WEST BENGAL | ₹31.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹32.9 L+₹1.2 L (3.67%)Rejected-Finance | ₹32.9 L+₹1.2 L (3.67%) | L2 | Rejected-Finance L2 |
| 3 | L3₹35.8 L+₹4.1 L (12.9%)Rejected-Finance | ₹35.8 L+₹4.1 L (12.9%) | L3 | Rejected-Finance L3 |
| 4 | L4₹36.8 L+₹5.0 L (15.9%)Rejected-Finance 1ST FLOOR OPP GURUDWARA GURUDWARA ROAD BENACHITY DURGAPUR 713213 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | 713213 | ₹36.8 L+₹5.0 L (15.9%) | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Allowed. |
Tender Value
₹37.0 L
EMD Value
₹73,977
Closing Date
15 Dec 2025, 2:00 pmClosed
EE, Malda Division, MED
Sevaniketan (2nd Floor), Atul Chandra Market, Malda - 732101
Installation of Pump-Motor Set, Internal and External Electrification of Plant Area, Compound, Ancillary Buildings (Office, Lab, Weighbridge Control Room, Security Room) and Pump Operational F.P. Box for the Proposed 73 TPD Municipal Fresh Waste...
2025_MAD_952681_1
03 of EE/MED/MLD/2025-2026(2nd Call)
Open Tender
ELECTRICAL WORKS ORG
Percentage
180 days
Within Balurghat Municiaplity
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹73,977
Yes
O/O The Executive Engineer, Malda Division, MED
31 Aug 2026
19 Nov 2025
17 Dec 2025
19 Nov 2025
15 Dec 2025
19 Nov 2025
26 Nov 2025
Pump- Installation & Fire Support System :- Supply, fitting & fixing G.I. Pipes of "TATA - make" with all necessary accessories, specials viz. socket, bend, tee, elbow, union, cross, nipple, long screw, reducing socket, short piece etc. fitted with holder bats clamps, well cover including cutting pipes, making threads, fitting, fixing as required with jointing materials and two coats of painting with approved paint in any position above ground level. [For Vertical Column pipes & upto header]--- (50 mm. dia. Medium Quality)
Supply & fixing 50 mm. dia. C.I. double flanged Swing Type Non- return valve generally conforming to IS:5312 of approved Brand / ISI / [PN-16 Rating] complete with Bronze body & wedge Stainless Steel spindle, gland packing, rubber gasket etc.
Supply & fitting and fixing 50 mm. dia. gunmetal wheel valve of approved Brand/ ISI make. [Tested- 21kg / sq. cm.] [For water delivery lines, Fire line, Office Building & wash out line.
Supply & Installation of Three Phase 415 v, 3 H.P. (2.2 Kw) 7 stage submersible pump-motor set suitable for 150 mm. dia. bore well having Head--33 mts. discharge 175 Ipm The discharge outlet size will be 65/50 mm.dia. (Make-KSB Cora -18 C/07 G +UMAI 100-2.2/22) or (Make -Bhagirathi Ganga - 6BGR-7 Model) or (Make - Crompton - 100 W7RQ3TP-65)
Supply & laying submersible cable for pump-motor set. Size 3 core x 2.5 sq.mm flat. [Make -Polycab / Havell's /Finolex]
Supply, fitting and fixing in position of G.I. Tata make.( Medium) quality for underground works with all necessary accessories, viz. socket, bend, tee, union, cross elbow, nipple, short piece, flange, plug etc. including cost of jointing materials, cutting pipes, making threads, cutting trenches up to 1.5 mts. below surface in all sorts of soil and refilling the same as per direction with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect as per G.S.
a. 50 mm. dia G.I. Pipes.
b. 25 mm. dia. G.I. Pipes
Supply & fixing S. S. Single Head Hydrant valve complete for 63 mm. dia. [ISI / Approved make ] CPWD. P-785, Code-4202/U.D & M.A-P-44/i-8.4/PWD-P-17/1-19.G.
Supply & fixing 65mm x 50mm reducing socket for Hydrant pipe line.
Supply & fixing Fire Fighting Hose Real [ RRL Hose) of 15 mts. long, 63 mm. dia. with instantaneous couplings and hose shall be stored inside the Hose cabinet. CPWD. P-785. Code-4209 + Non-Schedule (Cabinate) [Make -Force Industries / A..N..Ex flame Fire Protection PVT..Ltd./Fyrax India]
Supply of S.S. short branch pipe with Nozzle. [ Make -(Pyro Guard / Trade India / OMEX IS903)
Arrangement for 4 way Header assembly with S & f necessary 50mm x 50 mm dia. fittings as per direction of E.I.C. [ All fittings are TATA make / ISI ]
a. G.I. Tee.
b. G.I. Short Piece./ Nipple -75 mm. long
c. G.I. Socket.
d. G.I. Long bend (90 deg.)
f. G.I. End Cap. (50 mm. dia.)
g. S & f 25 mm. Dia. Gun metal Wheel Valve.
Supply & Fixing Fire bucket [9 Lts.] - [ATASEE - IS - 2546 / Attack Fire / BuyTm Industries]
S & F 40 mm. dia. G.I. pipe (TATA- Medium ) ISI mark submersible cable protection pipe with necy. Bend, Union Socket etc. as per requirement with supporting clamp. [Length - 5 mts. From the well. Approx. ]
S & F G.I. Column pipe M.S. holding clamp size - 12 * 50 mm with necy. nuts, bolts & washers etc. for submersible Pump set.
S & F anti snapping safety device for the P/M set with nylon rope binding at both side of the clamp as per direction of E.I.C. (if required).
S & F split type 12 mm. thick M.S. fabricated suitable for well cover with holes for column pipe & submersible cable etc. as per direction of E.I.C.
Construction of supporting pillar [Size-300x300x900 mm height] for resting Header lines for easy operation with net cement finish as per direction of E.I.C.
Making 4 -- way Header line by (80mm.dia x 1.5 mts Long ) G.I.(Medium) ISI mark pipe with 5 no's 80mm * 50mm dia reducing socket incl. cutting of pipes, welding, threading etc. as per direction of E.I.C.
Painting the total plumbing lines by weather proof epoxy paint dark green colour (ISI mark) branded paint after preparation of surface as per direction of E.I.C. [ Lump Sum Rate]
Supply, Installation and commissioning of L.T. Floor mounted Service cum Distribution Pillar Box made of suitable size [1372mm x 914mm x 607 mm depth as required made by 3.15 mm thick on top & 2.5 mm thick on body by CRCA sheet providing of 3-phase aluminium bus-bar system and heavy gauge iron angle / flat channel to be used as and where required and necessary making requisite compartment to be provided in it with cable allay system for outgoing cables and including supplying and fixing of the following accessories to be provided as per direction and as per requirement and making suitable size of copper wires and cables for inter-connection and as per direction of E.I.C. Legs of the P.B. will be 900 mm. in length by made upto of (40 x 40 x 5 mm) M.S.angle with suitable base plate. Legs of the P.B. will be erected at 300 mm. below the G.L. with cement concreate (6:3:1). Rest portion covered by 5" brick wall with plastering & net cement & bottom portion filled by silver sand. [Both side opening system incl. locking arrangement ] [The panel board should be painted with powder coated paint grey colour including hylam sheet, heat sink sleeves, bus-bar, isolator, rubber gasket and lifting lugs etc. ] { Mainly Service Panel cum Distribution P.B. }
IN COMING:- 1.a. 415 V, 250 amp. FP,4 pole on load front operated Change Over switch with sheet steel enclosure on angle iron frame as per G.S. (1 no) [Havells make ]
1.b. 415 V, 250 A. TPN.SFU with sheet steel enclosure on flat/angle iron frame incl. S&F 3 no's DIN type HRC fuse (2 no's Service side & incomming side) Havells make. (250 Amps main Switch has been considered according to the unit basis load consumption) [Havells Make]
1.c. 500 v, 315 A. Vertical type Al. Bar with 4 no's Al. Bar (4 x 50 mmx 10 mm.size) mounted on DMC Isolator as per direction of EIC [ Av. Length 0.85 imts. Approx: ]- 1 set.
1.f. R/Y/B indicatin LED lamp [L&T/ISI make] --1 item.
OUT GOING:- 1.g. 415 V, 200 A.TPN.SFU.with sheet steel enclosure on flat iron frame with S & F 3 no's DiN type HRC fuse as perrating & G.S.... [For Mini Panel board ------ 4 sets] [HAVELLS make] ( Inside shed at the plants) For each Unit basis [2 Units - Wet & Dry Waste]
1.h. 415 V, TPN SFU, 63 A, with sheet steel enclosure on flat/ angle iron frame on structural frame with nuts, bolts etc. incl. S&F 3 no's DIN type HRC fuse as per G.S.. [For Office room HTPN + Fire Pump & Spare] ---03 no's [HAVELLS]
1.1. 240 V, 32 A. TPN.MCB, breaking capacity 10 KA & C curve on Din Rail with sheet steel enclosure type Switch for Spare. ---1 no [HAVELLS make]
Supply & fixing 240V, 120 watt outdoor type street light fittings fitted on S.T Poles and also fitted or. G.l pipe bracket & necessary connection by suitable size of copper wires & earthing attachment as per direction of E.I.C.(analysis enclosed) (Bajaj/philips/Havells make) - smart bright - BRP 062LED 120 CWSLCAISIPU & BKTFG 120 watt LED IV2) (Bajaj - Rs. 12000-@18% G.S.T-Less @20% 8465.61+581.00) = 9047.61
Mini Panel Board :-73 TPD [2 Sets] Supply, Installation Industrial type LT. Floor cum Wall mounting M.S. Panel board made of suitable size [1500mm * 1200mm] and heavy gauge iron angle / flat channel (40 x 40 x 6 mm) & (25x3mm) to be and fixing of the following accessories to be provided as per direction and as per requirement and making suitable size of copper wires and cables for inter-connection and as per direction of E.I.C
1.1. Inter-connection charges with necy. Cables & wires with socketing & finishing as require and locking arrangement.
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. Size 0.6x0.6x1.70 nts incl Painting of Poles as per [2835.00+483.003318.00]
1.j. E.I Danger Board [20cm x 30cm] - 1 no
1.k.Cubical Service Panel Board Size - 1372 x 914 x 607 mm .)
2.c. S & F double door 2 + 6 way MCB D.B with IP-42/43 protection incl. 40 ADP.MCB isolator and 6 no's 10 A. MCB to be fitted on Hylam board incl. necy, interconnection with suitable size of copper wires and neutral link & provision for earting attachment as per G.S. (Havell's make)--1set [1073+1008+208 = 2289.00]
2.d. S & F 240 V, 20 A, Plug & Socket single door MCB protected board fixed on MS Sheet. With earting arrangement.2 nos. [Provision for Per Mini Panel 2 sets of Plug Board Industrial ply
2.e. S & F E.I. Danger Board [Size - 20 cm x 30 cm ] -1 no
2.h. R/Y/B indicatin LED lamp [L&T make] (1 item)
2.j. Fabrication cost by CRCA sheet box with front side 3 mm. thick Hylam board [4 sq.ft.] with 8 no's Pin type Cu.stud [2 sets ]for flexible cable connection with 2 no's 40 A FP.MCB control cut-out / Isolator for the stud connection. [Havells make]
2.k.Industrial Panel fabrication cost + Inter-connection + Painting + Transportation etc.
2.a. S & F 415 V, 200 A.TPN SFU, with sheet steel enclosure on angle iron frame on structural frame with nuts, bolts etc. incl. S&F 3 no's DIN type HRC fuse as per G.S.. [For Mini Panel board ------ 1 set] (Havells make)( Inside shed at Both End)
S & F 415 V, TPN SFU, 32 A, with sheet steel enclosure on angle iron frame on wall with nuts, bolts etc. incl. S&F 3 no's DIN type HRC fuse as per G.S.. [For Weighbridge control room] ----01 no. [Havells make]
2.b. 500 v, 200 A. Al. Bar with 4 no's Al. Bar (4 x 50 mmx 5 mm.size) Pa mounted on DMC Isolator as per direction of EIC [Av. Length 0.85 mts. Approx] (1 set)
S & Fixing 240 volt, 150 watt Indoor Type LED light fittings for Structural shade [height of the shade-34 ft.approx) with suitable clamping arrangement for holding the fittings with necy. Connection by suitable size copper wire & incl. earthing attachment as per direction of E.I.C. Analysis Enclosed [Rs. 12,699.92 + F.C Rs. 581.01 = Rs.13281.00 [Bajaj / Philips Make] - BY718 P LED 150/CW PSU NB IN & BGHB150 W LED G (VI)
[Bajaj / Philip Make] - Smart Bright - BRP062LED92 Supply of 240 volt, 120 watt watt Outdoor Street LED light fittings fitted on outside Vertical Structure frame and also fitted on G.I. Pipe bracket and necy. connection by suitable size copper wire & incl. earthing attachment as per direction of E.I.C.Analysis Enclosed CWSLCAISIPSU. & BRTFG 90W LED 1. V2
Supply of 240 volt, 90 watt Outdoor Street LED light fittings fitted on outside the wall of the building and also fitted on G.I. Pipe bracket and necy. connection by suitable size copper wire & incl. earthling attachment as per direction of E.I.C. Analysis Enclosed [Bajaj /Philips Make - BRTFG 45 W LED. V2 & BRP-062LED 045CW SLMR FG SI PSUGR
S & Fixing 240 volt, 185/200 watt LED Flood light luminaries fittings fitted on outside Vertical Structure frame by G.I. clamp and necy. connection by suitable size copper wire & incl. earthing attachment as per direction of E.I.C. [Bajaj / Philips Make - BVC 483 LED 185 CWAWBPSU GR & BJFL200 W LED I. WW.] Analysis Enclosed
S & F G.I water proof looping cable/wire box having hinged GI top cover having 4 mm. thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminals with lugetc. For 3x 2.5 sq.mm. PVC insulated copper wire through 20 mm. PVC.Rigid pipe comprising of one 240 V Fuse unit, one NL on porcelain insulator etc. and housing the same inside the wall and necy. net cement finish and necy, connection as per G.S. [[I no for Security Room + Weiglı Bridge Room + I no for Gate pillar for Glow sign Board and 2 no's for Office Room.] Size - 200 x 150 x 100 mm
Supplying of 1.1 KV. Grade XLPE/PVC/AL cable [Make -- Polycab/Havells/Gloster] of the following sizes cable :-
a. 1.1 KV. Grade 3.5 core 50 sq.mm PVC/Al. armoured cable. [From Service Pilier Box to Mini Piller Box ]
b. 1.1 KV. Grade 2 core 6 sq.mm PV*\mathcal{C} / A * l armoured cable [From Service Piller Box to Office Building, security Room & Weigh Bridge + Street Light etc.]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 3 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
(a) 3.5 X 50 sq.mm
(b) 2 X 6 sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring etc. inc! S & F cable sockets, insulateds, & soldering materials etc. & necy connection as per G.S [As per IS Code] (a) 3.5 X 50 sqmm (197+209) = 406×1.07
(a) 3.5 X 50 sqmm
(b) 2 X 6 sqrmm
Supply of 8 mts long steel tubular poie 111 kg. 410-SP-14 as per IS Specification - IS2317:1980. Approved make.
Distribution wiring in 22/0.3 (1.5 sq.mm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm. bore,3 mm. thick polythine pipe (for horizontal & vertical run in wall and ceiling portion through prelaid polythine pipe) complete with all accessories embedded in wall to light / fan / call bell points with modular type switch (Brand approved by EIC) fixed on Modular G.I.swich board with top cover plate flushed in wall incl. mending good the damages to the original finish. [ 2 * 22 / 0.3 (Ph. &N) and 16 SWG GI as ECC. (Average Run -6 mt.)
b. 240 V, 32 A. D.P. with fuse on L &N.[ O.R & WB ]---
Supply, Installation & commissioning of street light pole distribution kiosk box of suitable size { size - 900 mm x 600 mm x 900 mm .height } made by 2.5 mm thick CRCA sheet, proividing heavy gauge iron iron angle legs/flats channel to be used as an when necessary inc. supply & fixing 40 A. D.P. M.C.B (Havells make) and 2 + 4 way SPN.MCB.DB. with 40 A isolator with suitable size of copper wires for interconnection and as per direction of E.I.C. [ Analysis Enclosed]
Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.6 * 0.6 * 0.76mt above ground level, neatly cemented finish (3 mmthick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for all:athene/polythene pipeentry, for street light wiring, with supplying and fixing GI water proof looping cable box havinghinged GI Top Cover having 4 mm. thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (5:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting. [1039 + 498 = 1537]
Distribution wiring in 1.1 K.V single core stranded 'FR' PVC insulated & unshcathed copper wire (Brand approved by E!C) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required (a) 2 x 56/0.3 (4 sqının) + 1 x 36/0.3 (2.5 sqmın) ECC
Fixing outdoor type LED light Hitings on structural frame and pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated and sheathed copper wire (single core) from loop box at the base of pole to light fiting through pole & bracket (without control switch) including making connections & painting
S & F sheet metal loop box/inspection box (16 SWG) of size (225 X 200 X 65 mm) with bakelite top over & fitted on structural frame & below steel structure with clamping
system incl S & F 2 nos copper bar for loop in, loop out system & making earthing attachment & painting as per direction of EIC
S & F Acrylic letter scripted in English/Bengali size & matter of letter as per approved drawing by EIC, font side of the letter to be made 6 mm thick imported (white -0.40) uv stabilized excellent to self display,Make-Acast, Mitsubishi, all letter will be raised minimum 2" to be fixed by special type of sollution (total sqm of each letter to be measured based on its front surface area), incl. 26 gauge galvanised iron sheet for back panel with one coating of white paint.
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required ar.d connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Connecting the equipments to carth busbar including S & F 8 SWG. G.l.earth (Hot Dip) wire on wali/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 16 mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support 200x50x1.25mm (18SWG)
Supplying & fixing medium gauge GF Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required 50 mm dia.
S & F double door SPN.MCB (2+4) way. Distribution Board Enclosure with IP - 42/43 protections, concealed in wall after cutting the wall & mending good the damages to original finish include. Interconnection charges with suitable size of copper wire and neutral link & provision for earthing attachment. [Havells make SNO DRW04] (Weighbridge)
Electrification works for Office Room, Lab Room, Weighbridge Control Room and Security Room and Pump Panel at both part.
Distribution wiring in 22/0.3 (1.5 sq.mm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm. bore,3 mm. thick polythine pipe complete with all accessories embedded in wall to 240 v, 6 A, 5 pin plug point incl. S&F 240 v, 6 A. 5 Pin Modular type plug socket & Modular type switch Brand approved by EIC) incl. S & F earth continuity wire, fixed on 4 Module G.I. switch Board with ½ Module top cover plate flushed in wall incl. mending good the damages to original finish. 2 * 22 / 0.3 Ph& N) and 1 * 22 / 0.3 as ECC.
a) On Board -
b) Average Run
S & F Sheet metal Main switch on flat iron frame on wall (Havells Make)
Fixing only LED Tube light fittings complete with all accessories directly on wall / ceiling as per direction of EIC.
S & Delivery LED batten Tube Light fittings complete ( Philips make. Model -TMC501P 1 x T-LED 22 watt. P3241)
a. 240 V, 15/16 A. D.P. with fuse on L &N.[S/R]
Fixing only 12 watt LED lamp at Holder. [ 1-11]
S & F double door Horizontal 4 way.TPN MCB Distribution Board enclosure with IP-42/43 protections, concealed in wall after cutting the wall & mending good the damages to original finish include. Interconnection charges with suitable size of copper wire and neutral link & provision for earthing attachment. [Havells make -THO DRW04]- [PWD.Sch. P-D-11/1-14] (Office + Lab + W.B + Security)
S & F 240/415 Volt.MCB. Isolator on Din rail of existing DB's and necy. Connection - For Office, W.B & Pump Ρ.Β.
S &Fixing 240 V / 415 Volt MCB of Breaking capacity 10kA & characteristics on din rail of existing DB's and necessary connection 6-32 A. SP. MCB .+ HTPN( Havells make) (12 no's for HTPN + 4 no's for 4-way.
2. 32 A. D.P. MCB. Isolator. SPN.DB [4-way-SPN] [Havells make]
S & Delivery of 240 V, A.C. Ceiling fan of Crompton/Havells/ Bajaj make of 1200 mm. sweep. Model - Cool Breeze, Brown colour complete set.
S & Delivery 12 watt LED bulb (Philips/ Havells /Crompton] make. Model - New Adore 12 Watt, B-22/E-27 CDL Ball Lamp) as per direction of EIC.
Fixing only ceiling fan complete with blades, canopy, fork. rubber bush etc. incl. S& f connecting wire for down rod up to 30 cm. incl. painting the rod with approved paint and making necessary connection as required by 2 * 1.5 sq.mm. flexible copper wire.
S & fixing Socket type fan regulator [Step type] Brand approved by EIC, on existing sheet metal switch board incl. making necy. Connection etc.
S & delivery 250 V, Metal Exhaust Fan - 9 ^ prime prime (225 mm) sweep single phase complete with all accessories incl. louver shutter. [Model:- Crompton / Havells / Bajaj -Trans Air]
Fixing only exhaust fan after making hole in wall and mending good the damages and net cement finish etc. as practicable as possible and providing necy. Length of PVC insulated copper wire and making connection of 9" (225 mm) sweep Ex. Fan.
S & F 240 v, A.C. Buzzer (Anchor) on H.W. board incl. S & F H.W. Board.
1. 63 A. FP. MCB. Isolator. For TPN.DB. [HTΡΝ]
Pump P.B:- [Water supply] a. Supply & Installation of Feeder Pillar of size :- 1200 mm x 600 mm x 450 mm outdoor type, stand mounting, dust and vermin proof with IP -55 protection. The panel shall be made of 14 SWG [2 mm. thick] Cold Rolled Close Annealed (CRCA) Sheet Steel, shall have powder coated finish to required shade after pretreatment and standard enamel paint. Cable entry shall be the bottom and through a detachable gland plate. Stand for mounting shall be made of 50 mm x 50 mm x 4 mm. M.S. angle. Feeder pillar shall have Pad -locking arrangement. [ Capacity 3 H.P - 10 H.P) [Normal water supply & Fire system -Operation Pillar Box]
In-commer:-415 Volt, 63 A TPN.S.S. Enclosure type (Havells make) ---1 no. [Schedule rates] (Sch. D - 1 / I -1.b. )
Outgoing: 415 Volt, 63 amps. Al. 4-bars, BBC etc. as per schedule -1 set. (D-12/1-19.a)al
415 volt, 40 A, 4 Pole MCB. Isolator [Havells make ] - 1 no. [D-6/1-6]
415 volt, 3. Phase DOL compact Starter unit complete set. (WRIDD/CE. Approved Rate)
240 volt, 32 A. D.P.. Main switch [Havells make] (Schedule D-1/1-1) Spare
Danger Board [Size - 15cm * 10cm ] [Sch. - D - 13/1 -21.B.]
Fabrication Cost. (UD & MA-P-7/1-39 )complete work
Distribution wiring in 1.1 Kv. Grade single core stranded Fr. PVC insulated & unsheathed copper wire (Brand approved by EIC) in 19 mm. dia. PVC heavy gauge polythine (approved make) cutting channel of 40 mm x 40 mm size on wall and mending good the damages incl. necy. nails as required as per G.S. (from PBDB to A.C Power Point) [ PWD. Schedule - P-E-2,9/1-3,11
A. 2 x 56/0.3 (4 Sq.mm) + 1 x 36/0.3 (2.5 sq.mm) ECC.
B. 2 x 84/0.3 (6 Sq.mm) + 1 x 56/0.3 (4 sq.mm) ECC.
Supply, installation, testing & commissioning of wall mounted type 3-Star, Non-Inverter type 1.5 TR Split AC unit complete with all accessories, mounting brackets ,remote controller pipe, drain pipe, etc complete work as per direction of EIC. (Make- Hitachi) (Office & Lab room only)
Supply & Fixing 240 V,25 A, Modular type starter (Brand Approved by EIC) with 2.5 A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl S& F Switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire, etc. ( (Future Provision One No.)
Earthing with 50 mm. dia. ISI make - Medium Quality Gl pipe 3.64 mm. thick x 3.04 mts. Long and 1 x 4 SWG GI (Hot Dip) wire (4 mts. long), 13 mm dia x 80 mm. long G.I. bolts, double nuts, double washers incl. S & F 15 mm. dia. Gl pipe protraction ( 1 mt. long) to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.65 mts. Below the G.L. as per G.S.
Add GST @18% on Summation of Item no. 1 to 3.22
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.59 MB
WBF2911_2ndCall.pdf
Tender Documents • 2.01 MB
BOQ_2279870.xls
BOQ • 0.45 MB
Drawing2ndCall.pdf
Additional Documents • 5.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .