| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹15.9 L+₹98,766.95 (6.64%)Rejected-Finance 122 SAMHARIYA ASOPUR TANDA AMBEDKAR NAGAR UTTAR PRADESH 224190 | AMBEDKAR NAGAR | UTTAR PRADESH | 224190 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹16.0 L+₹1.1 L (7.36%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹17.2 L+₹2.4 L (15.8%)Rejected-Finance 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹18.6 L+₹3.7 L (24.9%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
8 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-60/2020-21 REPAIRS / MAINTENANCE AND CERTAIN B/R WORKS IN MES INSTALLATIONS, BUILDINGS, OFFICES IN DOMESTIC AND TECHNICAL AREA AT AF STATION AMBALA
2021_MES_419978_1
GE AF/AMB-60/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
11 documents required · 11 mandatory
₹500
GE AF AMBALA
₹40,000
Yes
30 Mar 2021
8 Feb 2021
10 Mar 2021
8 Feb 2021
8 Mar 2021
23 Feb 2021
15 Feb 2021 - 19 Feb 2021
60 days
Amount
Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame) and disposing off
Taking down chowkats or frames exceeding 1.5sqm but not exceeding 4sqm each but with shutters (without taking off shutters from the frame) and disposing off
Taking up or down 15mm bore steel water tubing and connections including disposing off, etc. complete all as specified and as directed
Taking up or down 20mm bore steel water tubing and connections including disposing off, etc. complete all as specified and as directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and disposing off complete all as specified and as directed
Disconnecting, dismantling and taking down PVC water storage tanks 250 to 500litres capacity from any location and disposing off complete all as specified and as directed
Taking off existing water proofing treatment including PCC padding, mortar bed, etc. hacking for keys, scrubbing and washing with clean water and disposing off rubbish, refuse, etc. complete all as specified and as directed
Dismantling boarding including fillets of any decription fixed in any position with nails / screws, etc. and disposing off complete all as specified and as directed
Dismantling stone slabs / tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar and disposing off complete all as specified and as directed
Dismantling mild steel work or wraught iron of any description and in any position complete all as specified and as directed
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and as directed
M&L for grinding, rubbing, washing clean and mirror polishing kota stone as in floors, walls, claddings, skirting, dado, etc. complete all as specified and as directed
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 10cm girth complete all as specified and as directed
M&L for 25mm thick plain cement concrete type B-1,1:2:4 (using 20mm graded stone aggregates) as in padding, floors, sub-bases, etc. finished to receive floor finishes, etc. complete all as specified and as directed
M&L for plain cement concrete 1:2:4 (type B-1) using 20mm graded stone aggregates as in coping, padding, kerbs, bed blocks, locking of interlocking tiles, for hold fasts, etc. including necessary formwork complete all as specified and as directed
M&L for plain cement concrete type B-0,1:2:4 (using 12.5mm graded stone aggregates) as in coping, drains, etc. complete all as specified and as directed
M&L for 75mm thick plain cement concrete 1:3:6 (type C-1) using 20mm graded stone aggregate as in hard standing, footpaths, pavings, etc. including making spike rolling to surfaces or making impressions of expanded metal whilst the concrete is green laid in alternate bays complete all as specified and as directed
M&L for 75mm thick plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in floors, plinth protection, pavings, etc. including making spike rolling to surfaces or making impressions of expanded metal whilst the concrete is green laid in alternate bays of 3m length and joints between bays filled with 85/25 grade bitumen and sand mix @ 1:2 complete all as specified and as directed
M&F for rolled sections conforming to Fe 410-W (grade E-250) quality- A as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:4) complete all as specified and as directed
M&L for bedding / screed bed 15mm thick in cement mortar (1:6) roughened to received floor finish complete all as specified and as directed
M&L for backing coat 10mm thick in cement mortar (1:4) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, roughened to receive tiles, etc. complete all as specified and as directed
M&L rendering 15mm thick in cement mortar (1:4) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, inner sides of drains, roof, etc. finished even and smooth without using extra cement complete all as specified and as directed
M&L rendering 10mm thick in cement mortar (1:6) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, inner sides of drains, roof, etc. finished even and smooth without using extra cement complete all as specified and as directed
M&L for rendering 5mm thick plaster, in cement mortar (1:3) on fair faces of concrete surfaces of soffits of slabs, ceilings, etc. finished even and smooth without using extra cement complete all as specified and as directed
M&L for rough cast plaster including 15mm thick rendering in CM 1:3 on brickwall or concrete surfaces, all as specified in SSR Part-I clause 14.22 complete all as specified and as directed Note: Rough cast finish shall be made as under: (i) After applying the under coat of cement mortar 1:3 and while it is still in plasic state the rough cast mixture consisting of crushed stone or fine gravel / aggegates (of size between 6 to 12mm depending on the texture required) mixed with course sand and cement in the ratio of 1:1:1 shall be applied and finished even (ii) The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered
M&L for preparing of new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) complete all as specified and as directed
M&L for preparing of new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
M&L for preparing of old steel surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint (tint as approved) complete all as specified and as directed
M&L for preparing of new wood / wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, tint as approved complete all as specified and as directed
M&L for preparing of old wood / wood based surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint, tint as approved complete all as specified and as directed
M&L preparation of new plastered / unplastered masonry / concrete wall surfaces, roof coverings, etc. and applying two coats of exterior acrylic anti-fungal paint (tint as approved by the GE) as per manufacturer's instructions complete all as specified and as directed
M&L preparation of old plastered / unplastered treated / untreated masonry / concrete wall surfaces, roof coverings, etc. including complete removal of existing treatment and applying two coats of exterior acrylic anti-fungal paint (tint as approved by the GE) as per manufacturer's instructions over and including 3mm thick wall care putty and a coat of wall primer complete all as specified and as directed
M&L for preparation of new masonry / concrete wall surfaces and applying two coats of oil emulsion distemper over a coat of wall primer including a coat of wall care putty 1mm thick including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed
M&L preparation of old plastered / unplastered, treated / untreated surfaces and applying one coat of oil emulsion distemper on walls, etc. complete all as specified and as directed
M&L preparation of old plastered / unplastered, treated / untreated surfaces and applying two coats of oil emulsion distemper on walls, etc. over and including 3mm thick wall care putty and a coat of wall primercomplete all as specified and as directed
M&L preparation of old plastered / unplastered, treated / untreated surfaces and applying three coats of white wash on walls, etc. complete all as specified and as directed
M&L preparation of old plastered / unplastered, treated / untreated surfaces and applying three coats of white wash on ceilings, etc. complete all as specified and as directed
M&L preparation of old plastered / unplastered, treated / untreated surfaces and applying one coat of white wash on ceilings, etc. complete all as specified and as directed
M&L for preparation of surfaces of wood or steel and treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc. area not exceeding 0.1sqm each complete all as specified and as directed
M&L for non-skid ceramic tiles, coloured, 7 to 8mm thick, joint free, edge cut, exceeding 0.06sqm and not exceeding 0.11sqm in size, of superior quality on floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles complete all as specified and as directed
M&L for non-skid ceramic tiles, coloured, 7 to 8mm thick, joint free, edge cut, exceeding 0.11sqm and not exceeding 0.18sqm in size, of superior quality on floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles complete all as specified and as directed
M&L for glazed ceramic tiles, coloured of size 450x300x7 to 8mm thick, of superior quality on vertical faces, dados, skirting, risers, etc. lset and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles with complete all as specified and as directed
M&L for chequered cement concrete tiles 300x300x25mm thick, set, jointed and pointed in neat cement slurry in floors laid over and including 15mm bedding layer in CM 1:4 complete all as specified and as directed
M&L machine cut and machine polished kota stone slab 20 to 25mm thick as in flooring in single piece laid, set and jointed in neat cement slurry and pointed with cement and pigments to match the shade of slab including rubbing and mirror polishing etc. laid over and including 20mm screed base in CM 1:4 complete all as specified and as directed
M&L machine cut and machine polished kota stone slab 18 to 20mm thick as in vertical surfaces, cladding, etc. in single piece laid, set and jointed in neat cement slurry and pointed with cement and pigments to match the shade of slab including rubbing and mirror polishing etc. laid against and including 15mm backing coat in CM 1:4 complete all as specified and as directed
S&F 18/19mm thick pre-laminated particle board, exterior grade, pre-laminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work in cupboard shutters, shelves, etc complete all as specified and as directed
M&L 35mm thick factory made plain framed paneled door shutter (two panels) 2nd class HW rail and style with lock rail and panels of 12mm thick ISI marked veeneered particle board with commercial veeneering on both faces, with size of rail and style shall be as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and as directed
S&F solid PVC wall lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as detailed and shown in SSR Part-I complete all as specified and as directed
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as detailed and shown in SSR Part-I complete all as specified and as directed
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed
S&F steel water tubing, 15mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS: 1239 fixed to walls / ceilings or laid in floor / trenches complete all as specified and as directed
S&F steel water tubing, 20mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS: 1239 fixed to walls / ceilings or laid in floor / trenches complete all as specified and as directed
M&L for bands, straps, supports or stays including bolts, if required hooks (stay), hand made sliding bolts, clamps, hold fasts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 grade E-165 including duly painting with two coats of synthetic enamel paint complete all as specified and as directed
M&L for framed works conforming to Fe 410-W (grade E-250) quality-A as in doors or gates of angle or other section with gusset plates, rails, braces, etc. drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and as directed
M&L in repairs for mild steel, 0.63mm thick, plain, black sheet in hearths, covering to door shutters, covering to door chowkats (frames), chullah hoods, water tanks, water troughs, ducts, urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel members, etc. with plain 40mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and as directed
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed
S&F in position steel rolling shutters, with thickness of lathe 1.25mm, without ball bearing, including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position, push pull or manual type including taking down of old shutter and disposing off complete all as specified and as directed
S&F steel ventilator with top hung shutter including hinges, steel peg stay, etc. to receive glazing / gauge and one coat of primer and including cutting into and fixing into walls, etc. with hold fast made out of flat iron 25x5mm complete all as specified and as directed
S&F steel window (box type) factory fabricated, double shutter (glazed and wire gauzed) with side hung shutters including pintle type hinges, steel handles fabricated type for each leaf duly welded, mild steel barrel tower bolts 150mm size (02Nos for each leaf) duly welded, with glazing bars dovetailed or welded including MS fillets, welding of guard bars with one shop coat of red oxide zinc chrome primer overall complete all as specified and as directed Notes: (i) Windows shall be fabricated as per CE Palam drawing No. TD-219 Sh 1/3 to 3/3 dated 02 Jan 2007 (updated up to date) and these drawings shall be referred at the O/o the GE (AF) Ambala (ii) Glazing, wire gauge, guard bars will be measured and paid separately under respective items herein (iii) Any other sundries, etc. as required at site shall be deemed to be included in the quoted rate (iv) For payment purpose double the area will be measured
S&F solid PVC door frame of size 50x47mm made out of 5mm thick plain / printed coloured PVC sheet (as approved) reinforced with MS square tube all as per specifications and drawing given in SSR Part-I 2009 all as per manufacturer's instructions and making good the disturbed surfaces complete all as specified and as directed
S&F factory made solid PVC moulded door shutter (with wood free EPS), 28 to 30mm thick (styles), with 2, 4, 6 raised panel design with 2mm thick moulded PVC sheet on the front and 2mm thick coloured PVC sheet (tint as approved) on back faces and fixing in frame at site all as shown in and specified in MES Schedule 2010 complete all as specified and as directed
S&F 100mm long mild steel medium weight cold rolled butt hinges fixed with screws / welded to frames complete all as specified and as directed
S&F 125mm long extruded aluminim handles, fabricated type, anodised complete all as specified and as directed
S&F 250mm aluminium anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed
M&L for hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed
S&F 3mm thick figured / pin head glass, ordinary quality, cut to required size and shape for windows, etc. in glazing not exceeding 0.5sqm in area with oil putty including hacking off old glass and putty fillings, etc. complete all as specified and as directed
S&F 3mm thick sheet glass, ordinary quality, area not exceeding 0.5sqm in each pane, cut to required size and shape to existing wooden shutters / MS windows / shutters, etc. with glazing clips, glass oil putty, etc including hacking out old broken glass (any thickness), cleaning hacked grooves, removing damaged putty, beads, etc complete all as specified and as directed
M&L for 2nd class hardwood plain fillets, square, rectangular or triangular in section, area exceeding 3sqcm but not exceeding 6sqcm, clean sawn, secured with nails or brads complete all as specified and as directed
M&L for 2nd class hardwood plain fillets, square, rectangular or triangular in section, area exceeding 6sqcm but not exceeding 13sqcm, clean sawn, secured with nails or brads complete all as specified and as directed
S&F in repairs continuous (piano) hinges, mild steel, bright finish or electro-galvanised, width of flaps when open 40mm complete all as specified and as directed
S&F in repairs hasp and staple, safety type, aluminium anodised, with mild steel hinge pin including bolt to hinge plate and fixed with 100mm screws complete all as specified and as directed
S&F in repairs 15mm dia bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S&F in repairs 15mm dia stop cocks / angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed
S&F in repairs 20mm dia stop cocks / angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed
S&F in repairs 15mm dia pillar taps, fancy type, cast copper alloy, with capstain heads, chromium plated, screwed down, high pressure, with or without lettered 'HOT'/'COLD', with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed
S&F brass chromium plated shower rose (minimum 40gm in weight) 195mm size fixed to 15mm bore pipe, with bend at 45o with flange of PTMT any colour, complete all as specified and as directed
S&F cast iron Nahani trap, with grating including jointing to waste pipe (dia of outlet 75mm) fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed
S&F in repairs wash hand basin, vitreous China, coloured, flat back type, of size 640x450mm, including CI brackets, cutting for and pinning in ends of brackets with coupling and including PVC connection 60cm key with brass union complete all as specified and as directed
S&F in repairs vitreous China squatting pan, Orissa pattern of size 580x440mm, white, with integral foot rests and 'P' or 'S' trap including lime concrete bedding, connecting and flushing pipe and trap complete all as specified and as directed
S&F 10litres capacity PVC flushing tank, white / coloured, syphonic action type, low level, valveless, with PVC inlet ball valve, PVC flush pipe, float and suitable sized brackets including cutting of floor / wall and making good to the disturbed surfaces in CM 1:3 with finishes to match with the existing and taking down of old PVC flush tank and disposing off complete all as specified and as directed
S&F 15mm PVC connections, 450mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed
S&F vitreous China bowl urinal flat back half stall of size 465x355x265mm (minimum), white, with grating and union for discharge pipe, including providing fixing plugs, brackets, grating, union and connections to flushing pipe, bedding urinal against wall in CM 1:2, securing bowl with plugs and 60mm long brass screws, pointing around urinal bowl in white cement (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed
Supplying, hoisting, fixing and connecting up rotational moulded polythylene water storage tanks (cylindrical vertical with closed top), 500litres capacity, hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. complete all as specified and as directed
S&F false ceiling with powder coated GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with 2Nos. unequal flanges of 20 & 30mm and web 27mm fixed to surrounding wall using nylon sleeves at 900mm c/c with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2m in length) of 0.55mm thickness, having curled web of 50mm and flange 26mm each with lips of 10.5mm fixed to intermediate channel with connecting clips at 457mm c/c to 6mm dia GI hangers (1.2m long) adjusting level fixed to roof slabs by means of ceiling cleats made of GI flat 40x3mm, 60cm long and expansion hold fasteners 12.5mm dia 40mm long including 9 to 10mm thick ceiling boards / tiles (of approved design) of size 600x600mm for insulation and accoustic purposes, decorative type, with silver foil coating on backsides fixed with staples on snap grid with and including 4mm dia GI wire, nuts, bolts, washers, etc. including taking down and disposing off old false ceiling complete all as specified and as directed
M&L for laying pre-polished 80mm thick rubber moulded, double glossy, coloured, designer, interlocking tiles made of M-40 design mix concrete of approved design and shape with the crushing strength not less than 400kg/sqcm laid over and including 25mm thick (compacted thickness) sand bed (rate shall be included) complete all as specified and as directed
M&L for Atactic Poly Propaneylene (APP) modified bituminous membrane, weight not less than 4.0kg/sqm, reinforced with non-woven polyester fibre @160gm/sqm by torch method as per manufacturer's instructions complete all as specified and as directed Specifications for membrane: (i) Softening point 150oC minimum (ii) Cold flexibility (-)2oC minimum (iii) Single centre core non-woven polyester reinforcement of not less than 160gm/sqm (iv) Tensile strength of 650N/sqcm and 450N/sqcm in longitudinal and transverse directions respectively (v) Minimum elongation of >20% in both directions (vi) Dimensional stability of 1% maximum (vii) Water tightness / impermiable at 2kgf/sqcm (viii) Water absorption of not more than 1% on mass within 24hrs (ix) Overlaps of minimum 100mm on longitudinal direction and 150mm along transverse direction shall be maintained while laying
S&F in position aluminium-zinc colour coated high tensile alloy steel trap sheeting of 0.5 to 0.53mm thick, high rib, having 550 Mpa yeild strength BMT 0.45mm and zinc (galvanized) and aluminum combined coating of 150 gms/sqm (AZ-150) of 0.50mm TCT having top colour coat of regular modified polyester/silicon modified polyester/HDPE polyester of 18 to 20micron and back coat of 5 to7 micron epoxy primer fixes, RMR 1040 profile width 1125mm in roofing panels / sheeting complete as per manufacturer's instructions, all as specified and as directed Note: The sheet shall be fixed to MS angles with self drilling and self topping screws conforming to AS 3566 with moulded EPDM washers
Shiv Construction Co.
Swami Enterprises
Bairagi Builders
Anil jindal and sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .