Loading…
Loading…
Tender ID
Tender Value
₹43.6 L
EMD Value
₹88,000
Closing Date
31 Mar 2026, 5:00 pmClosed
EXECUTIVE ENGINEER, P.H.E.D BANKA
EXECUTIVE ENGINEER
OFFICE OF THE EXECUTIVE ENGINEER, P.H.DIVISION BANKA
Rajiv Ranjan Lal
SUPERINTENDENT ENGINEER
REMAINING WORK OF REORGANISATION OF RURAL PIPED WATER SUPPLY SCHEME CHANDN AND 2 YEARS COMPREHENSIVE OPERATION AND MAINTENANCE UNDER P.H. DIVISION BANKA.
128210
SHORT TERM TENDER NIT No? 09/2025-26
Open Tender
CIVIL
Banka
• Registration paper of appropriate class, Govt of Bihar ( Refer NIT)
• PAN CARD
• GST Registration in State of Bihar with Last Return
• Work Experience (Refer Section 1 ITB Clause 4.5A (b) and 4.5 A (c) )
• Annual Financial Turn Over (Refer Section 1 ITB Clause 4.5 A (a) )
• Affidavit (Refer NIT and SBD Section 2 Qualification Information)
• Availability of Key Item of Constructions equipment (Refer SBD Section 2 Qualification Information)
• Key Personnel (Refer SBD Section 2 Qualification Information)
• Bidding Capacity ( Refer SBD Section 1 ITB Clause 4.7 and SBD Section 2 Qualification Information)
• Character Certificate (Refer NIT)
• Availability of Credit Facilities / Bank Certificate (Refer SBD Section 1 ITBClause 4.2 (i) and SBD Section 2 Qualitification Information)
• Litigation History (Refer SBD Section 2 Qualification Information and SBD Clause 4.3)
• Undertaking (Refer SBD Section 1 ITB Clause 4.2 (ii) and SBD Section 2 Qualification Information)
• Power of Attorney if any
• Proposed methodology and programme of construction (Refer SBD Section 1 ITB Clause 4.3 (l) and SBD Section 2 Qualification Information)
• Email id and Mobile no for Communication
• Any of Last Three Year Income Tax Return
• The bidders are required to submit a duly ?Notarized affidavit? stating that there are no outstanding electricity dues pending for payment against all electric consumer numbers in their completed or ongoing operation & maintenance contracts till 28.02.26.
CIVIL
ITEM RATE
L1
1
18 documents required · 18 mandatory
₹10,000
Processing Fee: 590
₹88,000
OFFICE OF THE EXECUTIVE ENGINEER P. H. DIVISION BANKA
28 Mar 2026
28 Mar 2026
1 Apr 2026
28 Mar 2026
31 Mar 2026
28 Mar 2026
30 Mar 2026
Supply Installation, commissioning and testing of single phase 3 H.P. submersible pump set having discharging capacity 3.35 lps at a total head of 35 meter(approx) of KSB/ Kirloskar or equivalent make with all accessories & fittings etc including load
Providing house connection for each house hold including supplying all materials, labours, tools and making ferrule connection with 20 mm dia MDPE and 15mm CPVC Pipes with all fittings etc all complete. (As per sub Estimate no.- 5)
Supplying all designs drawing construction and commissioning of fully tested and successfully well operated Standard type Fluoride Treatment Unit (activated allumina based/Nano technology based/any approved technology (CSIR) for removal of excessive fluor
Provision of safe waste water disposal etc. all complete work. (As per sub Estimate no.- 6B)
Man Power cost (Rs.322 x 365days x5year)
O& M cost of civil structure
O& M cost of Electrical and Mechnical
O& M cost of treatment plant including chlroura
OM cost of distribution system
Fortnightly Water testing
Training of 5 Nos benificeries and Departmental staff for O & M of the plant and creating water quality awareness compaign
Energy charge(72125.34/-year x 5year)
Block
DHORAIYA
NAME OF STATE
NAME OF DISTRICT
NAME OF BLOCK
NAME OF PANCHAYAT
NAME OF VILLAGE / TOLA
HABITATION BENEFITTED:
POPULATION:
PROPOSED WATER SUPPLY STATUS PER CAPITA
DETAILS OF PROPOSED SCHEME
Source
Motor Pump
Distribution Network
P.V.C. OVER HEAD TANK
HOUSE CONNECTION
COST OF SCHEME WITH O&M
COST OF SCHEME WITHOUT O&M
MAINTENANCE AGENCY
Description
Construction of 150mmX 90m deep T/W etc. all complete and as per direction of E/I. (As per sub Estimate no.- 1)
Constructing masonry Chamber 100x100x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Tube Well, and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ) , necessary excavation, foundation concrete 1:2:4(1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3coarse sand) 12 mm thick with 5% cico fnished with a floating coat of neat cement, out side plastering with cement mortar 1:4 (1 cement : 4coarse sand) 12 mm thick complete as per standard specifications & direction of E/I. (As per sub Estimate no.- 2)
Providing and Laying Distrbution network of High Density Polyethyene pipe (HDPE pipe) including 10000 liter PVC tank installed at 8M high R.C.C staging etc all complete as per direction of E/I. (As per sub Estimate no.- 3)
Supply and Installation of 3HP single phase Submersible pump and motor having discharge of 2.5 to 3 lps again a total head of 45 m including doing power and light wiring S/F service wire extention of L.T. line (0.3 km) & 65 mm dia GI medium class column pipe, 65 mmdia riser pipe (L), 65 mm dia N/R valve, 65 mm dia flange and supplying and installation of 6 KVA stabilizer, taking single psase connection, meter board, starter including power wiring all complete job etc. all complete as per direction of E/I.
Providing house connection for each house hold including supplying all materials, labours, tools and making ferrule connection with 20 mm dia MDPE and 15mm CPVC Pipes with all fittings etc all complete. (As per sub Estimate no.- 5)
Supplying all designs drawing construction and commissioning of fully tested and successfully well operated Standard type Arsenic Treatment Unit (activated allumina based/Nano technology based/any approved technology (CSIR) for removal of excessive Arsenic) suitable for designed flow of capacity given below pipeline, valve and specials all complete job as per requirement and demand of the E/I. The Mild steel pressure tank and other articles should have not less than as per the specification so as to sustain the design pressure with due factor of safety. It should be duly painted with two coats of anticorrosive paints over a coat of red oxide primer. The materials article should be as per respective Indian standard and should be manufactured from ISO : 9001 company including delivery charges and all taxes & duties complete including all civil works all complete as per standard specification and direction of E/I.12 KLPH Cacity
Construction of 8M high STEEL Staging for water storage & to house electric switch panel as per drawing attached. (As per sub Estimate no.- 6)
Installation of Electronically Regulated Doser type chlorinator using Sodium Hypo Chlorite (Hypo NaOCl) (As per sub Estimate no.- 7)
Man Power cost (Rs.322 x 365days x5year)
O& M cost of civil structure
O& M cost of Electrical and Mechnical
O & M cost of distribution system
Fortnightly Water testing & Monitring
Training of 5 Nos benificeries and Departmental staff for O & M of the plant and creating water quality awareness compaign
Energy charge(72125.34/-year x 5year)
Description
Transportation of Machine, equipments including all accessoreis etc.
Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. (All types of soil)
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC (UPVC) medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
(a) 150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC (UPVC) medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
150 mm nominal size dia
Supply Fitting and fixing the following fitting of approved make and specification at work site complete job
Supplying 3 mm to 6 mm well washed assoried pea gravel and doing surrounding around the annular space between bore hole & 125 mm pipe uniformity up to the depth 10 mtr. Below G.L. all work complete as per direction of E/I.
Carriage of Pea Gravel from Dhalbhumigarh (taken av distance 400km.)
Supplying all materials, labour and equipments to seal T/W up to the depth of 12 mtr. Below G.L by Sticky clay to prevent contamination form surface from all complete job as per direction of E.I
Supplying all materials labours and equipments including 150 mm dia G.I Cap/ C.I Cap over the casing of 150 mm dia T/W property all complete
Carriage of necessary equipment & materials
Supplying all tools equipments & labour for flushing washing and developing the T/W to give clean & clear water and all complete job as per direction of E.I
Description
% OF WORK
supplying all materials including laying of different types and size of GI pipe conforming to IS 1536/1989 (Third revision) with amendment no 1 & 2 in standard length in trenches including earth work in excavation in all kind of soil so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift including road cutting and crossing the pipe in ditches etc as required including supplying all jointing materials etc. including all taxces, duties etc. and incidental charges providing acessary tthrust block where as required construction of masanary chamber for valves with cost of certification mark and fixing in trenches including the cost of fulway valves, earth work in back filling the trenches after laying of different types and size of pipe fitting and valves with earth removed during excavation within initial lead and lift etc including providing night guard barrier and red light of safe guard against accident , testing of laid pipes etc all complete job as per specification and direction of E/I (As per sub Estimate no.- 3)
Supply Installation, commissioning and testing of single phase 3 H.P. submersible pump set having discharging capacity 3.35 lps at a total head of 35 meter(approx) of KSB/ Kirloskar or equivalent make with all accessories & fittings etc including load
Providing house connection for each house hold including supplying all materials, labours, tools and making ferrule connection with 20 mm dia MDPE and 15mm CPVC Pipes with all fittings etc all complete. (As per sub Estimate no.- 5)
Supplying all designs drawing construction and commissioning of fully tested and successfully well operated Standard type Fluoride Treatment Unit (activated allumina based/Nano technology based/any approved technology (CSIR) for removal of excessive fluor
Provision of safe waste water disposal etc. all complete work. (As per sub Estimate no.- 6B)
Construction of pump House 5.0M x 3.0M x 3.5M Hight with 1.8m x 1.2m x 2.4m high toilet & 10000 Liter PVC Tank over the roof of pump house with provide 5.0m staging etc. all complete as per direction of E/I.
Installation of Electronically Regulated Doser type chlorinator using Sodium Hypo Chlorite (Hypo NaOCl) (As per sub Estimate no.- 8)
Man Power cost (Rs.322 x 365days x5year)
O& M cost of civil structure
O& M cost of Electrical and Mechnical
O& M cost of treatment plant including chlroura
OM cost of distribution system
Fortnightly Water testing
Training of 5 Nos benificeries and Departmental staff for O & M of the plant and creating water quality awareness compaign
Energy charge(72125.34/-year x 5year)
Specification:
Time of Completion:
Estimated Cost:
Particulars
Supply Installation, commissioning and testing of single phase 2 H.P. submersible pump set having discharging capacity 2.5 lps at a total head of 35 meter(approx) of KSB/ Kirloskar or equivalent make with all accessories & fittings etc including loading unloading and transportation of the pump set to the work site with all required labour, materials, tools and tackles installation, testing & commissioning as per standards specifications and direction of E/I.
Supply Installation, commissioning and testing of floor mounted outdoor type L.T feeder pillar single phase starter controll pannel operated on 220 V, 3 phase , 50 c/s for 2 HP Submersible pump set made of MS sheet (minimum 2 mm thick) duly spray power coated painting with following accessories made of M.S sheet ( minimum 2mm thick) duly spray powder coated painting with following accessories
Supplying & fitting 2.5 mm2 copper service cable from power point from nearest source up-to pumping station..
Providing all materials and labour required for doing earthing station with G.I earth pipe of 40 mm dia x 4.5 mtrs 20fts. long G.I pipe including accessories excavation of earth , providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with salt, charcoal,etc.as per IE & IS specification.
Particulars
Supply Installation, commissioning and testing of single phase 2 H.P. submersible pump set having discharging capacity 2.5 lps at a total head of 35 meter(approx) of KSB/ Kirloskar or equivalent make with all accessories & fittings etc including loading unloading and transportation of the pump set to the work site with all required labour, materials, tools and tackles installation, testing & commissioning as per standards specifications and direction of E/I.
Supply Installation, commissioning and testing of floor mounted outdoor type L.T feeder pillar single phase starter controll pannel operated on 220 V, 3 phase , 50 c/s for 2 HP Submersible pump set made of MS sheet (minimum 2 mm thick) duly spray power coated painting with following accessories made of M.S sheet ( minimum 2mm thick) duly spray powder coated painting with following accessories
Supplying & fitting 2.5 mm2 copper service cable from power point from nearest source up-to pumping station..
Providing all materials and labour required for doing earthing station with G.I earth pipe of 40 mm dia x 4.5 mtrs 20fts. long G.I pipe including accessories excavation of earth , providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with salt, charcoal,etc.as per IE & IS specification.
Particulars
Earthwork in excavation over areas (exceeding 30 cm in depth 1.5m in depth 1.5 in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5m, disposal earth to be leveled and neatly dressed.
Length
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead
Supplying and filling in plinth with local sand and under floors including watering, ramming consolidating and dressing complete.
Length
Providing designation of 100A Brick on edge Soling joints filled with local sand including cost of watering, taxes & royalty all complete as per specification & direction of E/I.
Length
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth
Length
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level
Brick work with bricks of class designation 100A in foundation and plinth in :
Length
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth
Centering and shuttering including strutting, propping etc. and removal of form for:
Brick work with bricks of class designation 100A in foundation and plinth in :
Length
Reinforced cement concrete work in wall (any thickness), inclusing attached pilasters, buttresses, plinth and string courses, fillets, coloumns, plinth and string courses, pillars, piers, abutments, posts and struts etc. upto five floor level excluding the cots of centring, shuttering, finishing and reinforcement.
Length
Centering and shuttering including strutting, propping etc. and removal of form for:
In Shelves & Chajja RCC
Length
Centering and shuttering including strutting, propping etc. and removal of form for:
Length
Providing R.C.C. M-150 with nominal mix of (1:2:4) in roof slab
Length
Centering and shuttering including strutting, propping etc. and removal of form for:
Length
Reinforcement for RCC work including straightening, cutting, bending & placing in position and binding all complete.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Providing and fixing the M.S. grill of required pattern in frames of windows etc. with M.S. flat. Square or round bars etc. all complete
Length
Providing 6 mm thick cement plaster to ceiling of mix 1:4
Length
Cement plaster in coarse sand
Length
Windows
Steps
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 40mm nominal size) finished with a floating coat of neat cement punning etc.
Providing and fixing steel glazed windows of standard rolled steel sections, joints mitered and welded with 15x3mm lugs 10cm long with steel lugs embeded in cement concrete blocks 15x10x10cm concrete blocks (1:3:6) or with wooden plugs and screws or rawl including providing and fixing of glass panes with glazing clips and special metal sash putty of approved make complete including applying a priming coat of approved steel primer including the cost of metal bidding and other fitting all complete as per direction of E/I
Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade
Applying priming coat & painting with ready mixed paint of approved brand and manufacture in all sheds to give an even shade
Providing lighting arrangement both inside & outside the pump house including fitting & fixing two nos., tube lights inside the pump house ad one no. of Vapor Halogen light outside with all necessary electrical power wiring with suitable PVC sheathed copper conductor of ISI mar as per direction of E/I.
Earthwork in excavation over areas (exceeding 30 cm in depth 1.5m in depth 1.5 in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5m, disposal earth to be leveled and neatly dressed.
Brick work with bricks of class designation 100A in foundation and plinth in :
Providing R.C.C. M-150 with nominal mix of (1:2:4) in roof slab
Reinforcement for RCC work including straightening, cutting, bending & placing in position and binding all complete.
Providing brick bats 22 mm to 40 mm size for filling soak pit as par approved including carraige of bricks bats
Providing WC Pan, Sanitary and water supply connection Etc, All complete
Carriage of the following materials from quarry to work site including loading, unloading and staking at work site as per specification & direction of E/I.
Executive Engineer
P.H. Division, Bhagalpur West
Reinforced cement concrete work in wall (any thickness), inclusing attached pilasters, buttresses, plinth and string courses, fillets, coloumns, plinth and string courses, pillars, piers, abutments, posts and struts etc. upto five floor level excluding the cots of centring, shuttering, finishing and reinforcement.
Length
Centering and shuttering including strutting, propping etc. and removal of form for:
Providing R.C.C. M-150 with nominal mix of (1:2:4) in roof slab
Length
Centering and shuttering including strutting, propping etc. and removal of form for:
Length
Reinforcement for RCC work including straightening, cutting, bending & placing in position and binding all complete.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Providing and fixing the M.S. grill of required pattern in frames of windows etc. with M.S. flat. Square or round bars etc. all complete
Length
Providing 6 mm thick cement plaster to ceiling of mix 1:4
Length
Cement plaster in coarse sand
Length
Windows
Steps
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 40mm nominal size) finished with a floating coat of neat cement punning etc.
Providing and fixing steel glazed windows of standard rolled steel sections, joints mitered and welded with 15x3mm lugs 10cm long with steel lugs embeded in cement concrete blocks 15x10x10cm concrete blocks (1:3:6) or with wooden plugs and screws or rawl including providing and fixing of glass panes with glazing clips and special metal sash putty of approved make complete including applying a priming coat of approved steel primer including the cost of metal bidding and other fitting all complete as per direction of E/I
Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade
Applying priming coat & painting with ready mixed paint of approved brand and manufacture in all sheds to give an even shade
Providing lighting arrangement both inside & outside the pump house including fitting & fixing two nos., tube lights inside the pump house ad one no. of Vapor Halogen light outside with all necessary electrical power wiring with suitable PVC sheathed copper conductor of ISI mar as per direction of E/I.
Particulars
Structural steel work riveted or bolted in built up sections, trusess and framed work, including cutting,hoisting,fixing in position and applying a priming coat of approved primer all complete
Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including ressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All Kinds of soil
Supplying and filling in plinth with local sand and under floors including watering, ramming consolidating and dressing complete.
Providing designation of 100A Brick flat Soling joints filled with local sand including cost of watering, taxes & royalty all complete as per specification & direction of E/I.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of entring,shuttering,finishing and reinforcement-All work puto plinth level
Centring and shuttering including strutting,propping etc. and removal of form for.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of oundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead (50% of E/W in excavation)
Neat cement punning
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing anchor bolt of 20 mm dia and 0.60 Mtr length (bolt, washer & double nut) embedded in R.C.C pedestal all complete as per direction of Engineer in charge. @4x4x1.60kg
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:
Carriage of the following materials from quarry to work site including loading, unloading and staking at work site as per specification & direction of E/I.
Executive Engineer
Particulars
Earthwork in excavation over areas (exceeding 30 cm in depth 1.5 in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5m, disposal earth to be levelled and neatly dressed.
Dismantling brick on edge soling in road including stacking serviceable materials in stacks within 15mtr. Lead and disposal of unserviceable materials with all leads, all complete as per direction of Engineer-In-Charge.
Providing designation of 100 A brick Flat soling joints filled with local sand including cost of watering, taxes & royalty all complete as per specification & direction of E/I.
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
1:3:6 or richer mix
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth
Carriage of the following materials from quarry to work site including loading, unloading and staking at work site as per specification & direction of E/I.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
80mm dia nominal bore from PVC Tank to Distribution main
65mm dia nominal bore use for washout and overflow from PVC tank
50mm dia Pipe form T/well to PVC tank
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. all complete as per direction of Engineer-in-charge.
40mm dia GI Pipe
50mm dia GI Pipe
65mm dia GI Pipe
80mm dia GI Pipe
Providing and fixing brass gate valve with C.I. wheel of approved quality (screwed end).
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve,with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , necessary excavation, foundation concrete 1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize) and inside plastering with cement mortar 1:3 (1 cement : 3coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard specifications & direction of E/I.
Carriage 10% of item 11
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.
Particulars
Supplying all designs drawing construction and commissioning of fully tested and successfully well operated Standard type Fluoride Treatment Unit (activated allumina based/Nano technology based/any approved technology (CSIR) for removal of excessive fluoride) suitable for designed flow of capacity given below pipeline, valve and specials all complete job as per requirement and demand of the E/I. The Mild steel pressure tank and other articles should have not less than as per the specification so as to sustain the design pressure with due factor of safety. It should be duly painted with two coats of anticorrosive paints over a coat of red oxide primer. The materials article should be as per respective Indian standard and should be manufactured from ISO : 9001 company including delivery charges and all taxes & duties complete including all civil works all complete as per standard specification and direction of E/I.
Executive Engineer
Earth work in excavation
1.50m x 2.50m x 1.00M =
Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l.
Carriage of materials.
Items
Clean Coarse Sand filling
Brick Flat Soling
B Work in 1:4 C.M.
Cement Plaster 12mm/6mm (1:3)
Cement Plaster 12mm/6mm (1:4)
Particulars
Earthwork in excavation over areas (exceeding 30 cm in depth 1.5m in depth 1.5 in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5m, disposal earth to be leveled and neatly dressed.
Length
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead
Supplying and filling in plinth with local sand and under floors including watering, ramming consolidating and dressing complete.
Length
Providing designation of 100A Brick on edge Soling joints filled with local sand including cost of watering, taxes & royalty all complete as per specification & direction of E/I.
Length
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth
Length
Brick work with bricks of class designation 100A in foundation and plinth in :
Length
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth
Centering and shuttering including strutting, propping etc. and removal of form for:
Brick work with bricks of class designation 100A in foundation and plinth in :
Length
Reinforced cement concrete work in wall (any thickness), inclusing attached pilasters, buttresses, plinth and string courses, fillets, coloumns, plinth and string courses, pillars, piers, abutments, posts and struts etc. upto five floor level excluding the cots of centring, shuttering, finishing and reinforcement.
Length
Centering and shuttering including strutting, propping etc. and removal of form for:
In Shelves & Chajja RCC
Length
Centering and shuttering including strutting, propping etc. and removal of form for:
Length
Providing R.C.C. M-150 with nominal mix of (1:2:4) in roof slab
Length
Centering and shuttering including strutting, propping etc. and removal of form for:
Length
Reinforcement for RCC work including straightening, cutting, bending & placing in position and binding all complete.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Providing and fixing the M.S. grill of required pattern in frames of windows etc. with M.S. flat. Square or round bars etc. all complete
Length
Providing 6 mm thick cement plaster to ceiling of mix 1:4
Length
Cement plaster in coarse sand
Length
Windows
Steps
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 40mm nominal size) finished with a floating coat of neat cement punning etc.
Providing and fixing steel glazed windows of standard rolled steel sections, joints mitered and welded with 15x3mm lugs 10cm long with steel lugs embeded in cement concrete blocks 15x10x10cm concrete blocks (1:3:6) or with wooden plugs and screws or rawl including providing and fixing of glass panes with glazing clips and special metal sash putty of approved make complete including applying a priming coat of approved steel primer including the cost of metal bidding and other fitting all complete as per direction of E/I
Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade
Applying priming coat & painting with ready mixed paint of approved brand and manufacture in all sheds to give an even shade
Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade
Applying priming coat:Applying one coat of cement primer of approved brand and manufacture on wall surface:
Structural steel work riveted or bolted in built up sections, trusess and framed work, including cutting,hoisting,fixing in position and applying a priming coat of approved ateef primer all complete.
Providing ralling at the top with 25 mm GI Pipe
Providing necessary arrangement for proper fixation of PVC Tank for lateral stability against wind pressure force
Providing lighting arrangement both inside & outside the pump house including fitting & fixing two nos., tube lights inside the pump house ad one no. of Vapor Halogen light outside with all necessary electrical power wiring with suitable PVC sheathed copper conductor of ISI mar as per direction of E/I.
Earthwork in excavation over areas (exceeding 30 cm in depth 1.5m in depth 1.5 in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5m, disposal earth to be leveled and neatly dressed.
Brick work with bricks of class designation 100A in foundation and plinth in :
Providing R.C.C. M-150 with nominal mix of (1:2:4) in roof slab
Reinforcement for RCC work including straightening, cutting, bending & placing in position and binding all complete.
Providing brick bats 22 mm to 40 mm size for filling soak pit as par approved including carraige of bricks bats
Providing WC Pan (580 x 440 mm), Sanitary and water supply connection Etc, All complete
Carriage of the following materials from quarry to work site including loading, unloading and staking at work site as per specification & direction of E/I.
Executive Engineer
P.H. Division, Bhagalpur West
Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1500 (1 M á 0.9 M á 0.1 M)
Providing Saucket at joints to G.I. pipes and specials including testing of joints but excluding the cost of Lime
40mm dia Joints
50mm dia Joints
65mm dia Joints
80mm dia Joints
Cost of the laying fifting and fixing of G.I pipe line of size 40 mm to 80 mm dia Including Supplying materials & labours & constructing Sluice Valve Chamber of following sizes having 250 mm thick wall in cement mortar (1:4) including 12 mm cement plaster(1:3) with punning inside RCC cover slab with CI surface cover of 100 mm dia including earth work, B/F/soling, PCC (1:2:4) in foundation refilling etc. all complete work as per S/D of E/I. Type I for pipe dia. in 100 to 150 mm ( 0.90M x 1.2M x 1.2M deep) and also including Providing and fixing C.I. Sluice Valves (With Cap) Complete With bolts, Nuts, Rubber insertions etc. (the tail pieces if required will be paid separately) 150 MM dia
Assistant Engineer
P.H. Sub-Division, No-3
Bhagalpur
Particulars
Supplying all designs drawing construction and commissioning of fully tested and successfully well operated Standard type Arsenic Treatment Unit (activated allumina based/Nano technology based/any approved technology (CSIR) for removal of excessive Arsenic) suitable for designed flow of capacity given below pipeline, valve and specials all complete job as per requirement and demand of the E/I. The Mild steel pressure tank and other articles should have not less than as per the specification so as to sustain the design pressure with due factor of safety. It should be duly painted with two coats of anticorrosive paints over a coat of red oxide primer. The materials article should be as per respective Indian standard and should be manufactured from ISO : 9001 company including delivery charges and all taxes & duties complete including all civil works all complete as per standard specification and direction of E/I.
Particulars
Structural steel work riveted or bolted in built up sections, trusess and framed work, including cutting,hoisting,fixing in position and applying a priming coat of approved primer all complete
Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including ressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All Kinds of soil
Supplying and filling in plinth with local sand and under floors including watering, ramming consolidating and dressing complete.
Providing designation of 100A Brick flat Soling joints filled with local sand including cost of watering, taxes & royalty all complete as per specification & direction of E/I.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of entring,shuttering,finishing and reinforcement-All work puto plinth level
Centring and shuttering including strutting,propping etc. and removal of form for.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of oundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead (50% of E/W in excavation)
Neat cement punning
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Providing corrugated G.S. sheet roofing fixed with G.I.J. or hooks, bolts and nuts 8 mm diameter with bitumen and G. I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete (upto a pitch of 60°) excluding the cost or purlins, rafters and trusses.
Providing and fixing anchor bolt of 20mm dia and 0.60 Mtr length(bolt, washer and double nut) embedded in R.C.C pedestal all complete as per direction of Engineer in charge. @4x4x1.60kg
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:
Carriage of the following materials from quarry to work site including loading, unloading and staking at work site as per specification & direction of E/I.
Particulars
Providing cost of electronically regulated Doser type chlorinator using sodium Hypo Chlorite (NaOCl ) and installation including all cost and necessary fittings and connections as required and carriage cost etc. all complete as per direction of E/I.
Executive Engineer
Particulars
Supply and Installation of 3HP single phase Submersible pump and motor having discharge of 2.5 to 3 lps again a total head of 45 m including doing power and light wiring S/F service wire extention of L.T. line (0.3 km) & 65 mm dia GI medium class column pipe, 65 mmdia riser pipe (L), 65 mm dia N/R valve, 65 mm dia flange and supplying and installation of 6 KVA stabilizer, taking single psase connection, meter board, starter including power wiring all complete job etc. all complete as per direction of E/I.
Supply Installation, commissioning and testing of floor mounted outdoor type L.T feeder pillar single phase starter controll pannel operated on 220 V, 3 phase , 50 c/s for 3 HP Submersible pump set made of MS sheet (minimum 2 mm thick) duly spray power coated painting with following accessories made of M.S sheet ( minimum 2mm thick) duly spray powder coated painting with following accessories
Supplying & fitting 2.5 mm2 copper service cable from power point from nearest source up-to pumping station..
Providing all materials and labour required for doing earthing station with G.I earth pipe of 40 mm dia x 4.5 mtrs 20fts. long G.I pipe including accessories excavation of earth , providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with salt, charcoal,etc.as per IE & IS specification.
Description
Cost of Operation
Pump operator (Rs.318+ (15% +1%+18%))
Cost of Maintenance
O&M cost of Civil structure (2% of Staging & Masonary chamber)
O&M cost of Electrical and Mechanical Item (2.5% of the cost of EM equipment )
O&M cost of Chlorination Including chemicals
O&M cost of Distribution System-16000/-Km X (----- Km / year)
Cost of Energy charges
O & M of Water Treatment Plant with comprehensive AMC
Executive Engineer
Description
Cost of Operation
Pump operator (Rs.318+ (15% +1%+18%))
Cost of Maintenance
O&M cost of Civil structure (2% of Staging / Switch Room/ Pump House & Masonary chamber)
O&M cost of Electrical and Mechanical Item (2.5% of the cost of EM equipment )
O&M cost of Chlorination Including chemicals And Water Testing
O&M cost of Distribution System-16000/-Km X (----- Km / year)
O & M of Water Treatment Plant with comprehensive AMC
Executive Engineer
24 MONTHS
As per eproc2. (to be paid online)
Rs 10000.00 (to be paid online)
Name and Address of the Bidder
Particulars
Supplying and installation centrifugal pump and motor including making rising and delivery pipe connection, cost of valves and main service connection by power cable with transformer to main switch including power wireing, panel board, volt meter, ammeter, OBC switch, starter, required size earthing etc all complete as per direction of E/I.
Design, detail engineering, soil investigation work, preparation of working drawing, Construction of Ground storage tank at OHT sites of effective storage made with M-30 grade concrete( design mix is mandatory), including proper measures to counter-balance Uplift force, considering ground water level may rise up to existing ground level, including provision for water-proofing compound, water-stopper, and any other measures as required to make the structure water-tight including Pump House and Pumps , Motors & associated pies and valves all comple.(150 KL) (As per sub Estimate no.-08)
Painting work of 1.50m (High) Compound wall. As per sub estimate no-10
Provision for Retrofitting work of existing house connection. As per Sub-Estimate No.-11
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NOTES TO TENDER.docx
NIT • 0.40 MB
09_2025-26 Tender Notice.pdf
NIT • 1.14 MB
09_2025-26 Paper Cutting.pdf
NIT • 1.07 MB
BOQ CHANDAN PWS.xls
NIT • 1.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .