Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.5 CrAdmitted-Finance | ₹79.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹79.7 CrAdmitted-Finance | ₹79.7 Cr | L2 | Admitted-Finance |
| 3 | L3₹80.0 CrAdmitted-Finance | ₹80.0 Cr | L3 | Admitted-Finance |
| 4 | L4₹80.7 CrAdmitted-Finance | ₹80.7 Cr | L4 | Admitted-Finance |
| 5 | L5₹84.3 CrAdmitted-Finance 614 HARIOM TOWER COMMERCIAL COMPLEX CIRCULAR ROAD LALPUR RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | ₹84.3 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | HEIGHTEN CONSTRUCTIONS L2 | M/S B.P.CONSTRUCTION L1 | RAJBIR CONSTRUCTION PVT. LTD. L5 | SHREE RAM-TRIBENI JV L3 | M/S SINGHAL ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | 1,21,410 | Sqm | 13 ₹15.8 L | 13 ₹15.8 L | 6.5 ₹7.9 L | 12.8 ₹15.5 L | 9.9 ₹12.0 L |
| 2.00 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. | 20,861.75 | Cum | 134 ₹28.0 L | 136.64 ₹28.5 L | 139.58 ₹29.1 L | 133.98 ₹28.0 L | 148.5 ₹31.0 L |
| 3.00 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) | 430.46 | Cum | 14 ₹6,026.44 | 15.51 ₹6,676.43 | 14.26 ₹6,138.36 | 13.69 ₹5,893 | 24.75 ₹10,653.89 |
| 4.00 | Excavation in Soil using Hydraulic Excavator and Tippers with Disposal upto 1000 metres.Excavation for road work in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and tranporting to the embankment location within all lifts and lead upto 1000 m | 11,961 | Cum | 49 ₹5.9 L | 51 ₹6.1 L | 400 ₹47.8 L | 49.6 ₹5.9 L | 123.75 ₹14.8 L |
| 5.00 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation frenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l | 884.19 | Cum | 49 ₹43,325.31 | 55.28 ₹48,878.02 | 118.49 ₹1.0 L | 48.78 ₹43,130.79 | 99 ₹87,534.81 |
| 6.00 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) | 9,481.12 | Cum | 113 ₹10.7 L | 115 ₹10.9 L | 50.82 ₹4.8 L | 113.74 ₹10.8 L | 138.6 ₹13.1 L |
| 7.00 | Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume). | 5.48 | Cum | 519 ₹2,844.12 | 589.51 ₹3,230.51 | 550 ₹3,014 | 520.24 ₹2,850.92 | 594 ₹3,255.12 |
| 8.00 | Excavating, supplying and filling of local earth/Sand (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. | 88,222.1 | Cum | 287 ₹2.5 Cr | 287 ₹2.5 Cr | 500 ₹4.4 Cr | 287.6 ₹2.5 Cr | 297 ₹2.6 Cr |
| 9.00 | Extra for compaction of earth work in embankment under oisture conditions to give at least 95% of the maximum dry density(proctor density). | 84,987 | Cum | 16 ₹13.6 L | 17.84 ₹15.2 L | 30 ₹25.5 L | 15.74 ₹13.4 L | 19.8 ₹16.8 L |
| 10.00 | Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | 9.33 | Cum | 4,618 ₹43,085.94 | 5,247.64 ₹48,960.48 | 9,000 ₹83,970 | 4,631.04 ₹43,207.60 | 6,435 ₹60,038.55 |
Tender Value
₹90.6 Cr
EMD Value
₹90.6 L
Closing Date
1 Mar 2023, 3:00 pmClosed
Executive Engineer
5th Floor Udyog Bhawan Ratu Road Ranchi Jharkhand
Construction of Logistic Park Nirsa Dhanbad.
2023_JIIDC_66261_1
JIIDCO/14/SBD/ Nirsa Dhanbad/ 2022-2023
Open Tender
Civil Works
910 days
DHANBAD
Please refer Tender documents.
5 documents required · 5 mandatory
₹11,800
JIIDCO
₹90.6 L
5th Floor Udyog Bhawan Ratu Road Ranchi Jharkhand
17 Apr 2023
9 Feb 2023
2 Mar 2023
9 Feb 2023
1 Mar 2023
9 Feb 2023
20 Feb 2023
Amount
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B)
Excavation in Soil using Hydraulic Excavator and Tippers with Disposal upto 1000 metres.Excavation for road work in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and tranporting to the embankment location within all lifts and lead upto 1000 m
Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation frenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l
Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume).
Excavating, supplying and filling of local earth/Sand (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Extra for compaction of earth work in embankment under oisture conditions to give at least 95% of the maximum dry density(proctor density).
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade Excluding the cost of centering and shuttering - All work upto plinth level 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Supplying and stacking at site. 90 mm to 45 mm size stone aggregate
Supplying and stacking at site. 63 mm to 45 mm size stone aggregate
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.)For Grading -II Material
Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing
Cement Concrete Pavement Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with approve grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per 18: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
All works Above plinth level
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering Retaining wall for tow wall
Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ)
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Providing Tor steel reinforcement of all dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for Tata (Tiscon),SAIL,JSPL,Electrosteel Steel Ltd.Bokaro &Vizag ( RINL)
Providing Tor steel reinforcement of 8mm. dia rods as per approved design and drawing -do- -do- TMT Fe 500 do-do
Providing Tor steel reinforcement of 10mm.,28mm,32mm Dia. bars as per approved design and drawing -do- -do -
Providing Tor steel reinforcement of 12mm,16mm,20mm,25,Dia. bars as per approved design and drawing -do- -do-
Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I
Providing designation 75A work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:3) in superstrure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112 mm thick reinforced designation 100 A brick work vuith fly ash lirne brick (FLAG)confirming to lS 12894-1990 (9"x4'5"x3" ) in C.M. ( 1 . 4 ) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials,n caffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specificationand direction of E/|.
Extra for providing and placing in position 2 Nos 6mm dia with stirrup. M.S. bars at every third course of half brick masonry.
Supplying fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts, hendle, cleats and sand blocks and laxes all conrplete as pe building specrfication and direction of E/l.
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire- retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing 12 mm thick frameless toughened glass GLAZING CUM DOOR shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings and U channel under floor for fixed portion with silicon jointing fitting all complete as per direction of Engineer-in-charge
Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in?charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge
Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete.
Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.)
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
SITC of Motorised Rolling Shutter - Model: RS78GS, Make: Gandhi Automation or equivalent - Clear width x Clear Height - 5m x 5m - Curtain made of single skinned Galvalume steel laths with natural finish - Pressed galvalume steel hood & motor cover with natural finish - Wind lock-Storm anchors - CE Certified CRS Compact Gear P.R.C. Make Indirect Drive Operator - Three station push button with deadman control
SITC of Motorised Fire Rated Rolling Shutter - Model: Fire Warrior, Make: Gandhi Automation or equivalent - Clear width x Clear Height - 5m x 5m - Tested & approved by Exova Warrington UK which comply with BS 476: Part 22: 1987 standards - Curtain made of single skinned galvalume steel laths with natural finish - Three station push button
SITC of Electro Hydraulic RDL Series Dock Leveler - Model: RDL 2025 - Width x Length - 2m x 2.5m - Carrying Capacity: 6T point load (or uniformly distributed load 15T) - Pair of Super Bumpers - 150mm (W) x 80mm (D) x 400mm (H) with heavy steel support
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty as per building direction of E/I.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 6mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 1.5mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I.
Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5with 5% cico or any other approved water proofing compoundincluding taxes and royalty all complete as per building specification and direction of E/l.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.Two or more coats on new work
Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.
wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
Providing and laying 25mm thick kota stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. Single Piece
Providing and laying 25mm thick kota stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. Single Piece
Providing and laying vitrified Paring / Industrial tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 4457:2007, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 300x300 x 10 mm sizes.
Providing and laying, Doublecharge vitrified floor tiles in different sizes (thickness to be specified by lhe manufacturer) with water absorption less than 0.08% and conforming to lS 15622/ISO 13009 of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 600x600 mm
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile
In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile
Providing and laying vitrified Paring / Industrial tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 4457:2007, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 300x300 x 10 mm sizes.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished machine cut granite for kitchen platforms, vanity counters, wondow sills, fascias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing etc. complete at all levels.Area of slab upto 0.50 sqm
Providing and fixing 75 mm high, 50 mm deep and 18 mm thick stone slab table rubbed, edges rounded and polished, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade
Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.Granite work
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Extra for filling grooves with polysulphide 5mm wide, 10mm deep.
Providing and applying Industrial Epoxy Flooring, 3 mm Epoxy system with 2mm screed and 1mm top coat. Product name: Floarm PES (primer & Screed), Flowarm QS 3080 (Aggregate) and Floarm Top SL1-ST (P) for Top coat, make MYK Arment or equivalent products of FOSROC
Providing Retro-reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge.
Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineerin- Charge.
80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern.
WATERPRROFING FOR OLD AND NEW ROOF SLAB : Providing and laying waterproofing treatment on Roof Slab by applying two component factory designed ,ready to use ,acrylic modified flexible material applied with brush ,roller, or spray for waterproofing coating caoting as per manufacturer specification and following steps surface praparation : Providing nd cleaning of concree surfase to remove the dust oil,grease including removal of existing loose paint/ coating and cement laitance by cleanning with compressed air and water jet including all materials ,laobour tools complete .Pondig test to be done after plugging all outlets and to checked from soffit to identify seepage ,leakage . on identification of seepage ,cement grouting to be done with non shrink expanding admixture of SIKA INDIA PVT Ltd /MYK Schomburg /Dr.Fixit/fosroc or equivalent . providing and Repairing of all corners and joints such as those between the parapet wall and the roof slab etc shall be campererd with 150 mmx150 mm fillet of mortor (Cement :sand-1:4) Admixed with acrylic polymer of Sika /Fosroc/MYK/Dr.Fixit damaged concreting base slab,dead cracks if any with an acrylic polymer modified repair mortor including coat of Bonding agent of the same with cement slurry including all material,labour,tools comlplete.
b) Apply fisrt coat two component acrylic modified ,ready use ,flexible cementituous material on surface saturated dry roof and inside wall of paraphet wall upto 600 mm by brush or roller .After 1st coat of application ,45 GSM of fibre cloth to lay when fibre glass cloth when the first layer is still in green .1st coat to be applied @1.5kg/sqmt/coat. for the purpose of measurement entire treated surface will be maesured. c)2nd coat -To apply the 2nd coat of two component acrylic modified ready to use ,flexible cementituous material at right angle to the first coat over the glass fibre laid surface 2nd coat should be applied at @.7 kg /sqmtr /coat. for the purpose of measurement entire treated surface will be maesured.After three days of drying 2nd coat the rain water outlets to be plugged and ponding test to be done for 48 hrs to identify the seepage ,leakage from the sofit and if found necessary rectification to be done as per satisfaction of E/C.
The waterproofing coating to protected from damage before screed over it.Waterproofing brand- Sika Topseal 109hi/Fosroc Brushbond RFX/Dr.Fixit Pidifin 2K/MYK Aquafin TG Product Prformance--Chemical Base part A Acrylic Polymer ,Part B ,Specially graded cementitious powder Density -1.6 Kg/l(mixed density) at 27 C .Tensile strength -2N/MM2 After 28 days (with fibre cloth )According to ASTM D2370),Pull out bond strength -2N/mm2(concrete failure )According to ISO 4624 Slant shear bond strength -4N/MM2(According to FIP 5.15)Elongation at break -35% without fibre cloth and 20% with fibre cloth (According to ASTM D2370) d) Protection of treated surface with PCC -The treated surface should be covered with 25mm/50MM PCC of M-20 Grade (1:1.5:3) with proper slope (1:20) towards the rain outlets in alternate pannel of 2mtrx2mtr keeping gap of between the pannel joint .Integral waterproofing admixture confirming to IS 2645 @ 100ML Per Bag of cement to be added in screed concrete (Paid seperately for this item) all corners to be champered with 150mmx150mm fillet .The Rain water oulets shall be just levelled with the screed to ensure smooth discharge of water -The pherperal gaps between PVC pipes oulet and concrete surface to be packed properly with moisture insensitive epoxy putty of Sika India Pvt Ltd/MYK Schomburg/Dr.Fixit/Fosroc.
Covering of treated surface with PCC :- Providing 50 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm siza graded and cleaned sand of F.M 2.5 to 3 including screening, shuttering,and mixingcement concrete in mixer with admixture of integral water proofing and placing in position,striking curing,taxexand royality all complete as Per building specifiction and directions of E/.Panels that has been left should be casted next day. There should be 6 mm gap between Panels .Brand-Sika-Plastocrate plus, MYK proof WP 10,Fosroc-Conpiast X 4211C, Dr.fixit Pidiproof LW+ or Equivalent ,
Providing and mixing integral waterproofing compound in concrete or plaster as per manufacturer specification and as per direction of Eng in charge Brand-Sika plastocrete plus,/MYK Schomburg WP 10 /Dr.Fixit-Pidiproof lw+/Fosroc -Conplast X421IC or equivalent
Providing and filling of 6 mm thick Groove between 50 mm PCC Panels with 6 mm thick 25 mm deep thermocol strip and filling the rest 25 mm with Polysulphide Sealant (Poring Grade)as per drawings and technical specifications and direction of E in Charge.(with 18% GST).Brand:-Sika- Polysulphide, Fosroc-Thioflex 600,Dr." Fixit Pidi Seal PS(42P),MYK Seal PS or Equivalent
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:
Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.
IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.
IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.
IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per square metre, including preparation of surface but excluding grading complete with Bitumen felt (hessian base) type 3 grade I conforming to IS : 1322
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. all complete
For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required with all Fittings Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of paymen
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including
Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers
Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight
Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.
The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately
The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 1702
Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVh
Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.
Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml
Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm
Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site.
Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.
(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in?Charge.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:
Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design
Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation.
Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge.
However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Supplying Fixing Lift of Following Specificaion Jhonson or Eque. NEXTRA/ 8 PASSENGER LIFT/ 544 Kgs / 4 Floors / Stops / STAINLESS STEEL (1.5 mm) Car Cabin No. of Elevators-1 Nos. Elevator for your project at Garhwa Type & Capacity-Passenger – 08 Persons – 544 Kgs. (Neo) Speed-1 Mtr/Sec (approx.) Type of Drive-Variable Voltage Variable Frequency Drive with Microprocessor based Simplex Full Collective Control Type of Machine -Top - Gearless Machine - MRL Required Travel- 10 Meters. (max.) Serving -Ground to 3st Upper-Floor 4 -Stops, 4 -Levels,4- Openings Well Size.-1900 mm Wide x 1750 mm Deep (over Plaster) Power Supply-415 V three-phase 50 cycles alternating current Auxiliary Required-Single-phase 220 V 50 cycles alternating current Car Size (Clear Inside) approx.-1300 mm Wide x 1100 mm Deep Required Pit Depth-1600 mm. Required Head Room-4500 mm. Car Enclosure-Car Finish –Vandal Proof Flooring-PVC Flooring Electric Light-LED Light fitting Fan-400/300mm Sweep One Number No. of Entrances-One Location – Front.
Car Entrance-Automatic Power Operated Center Opening Vandal Proof Stainless Steel Doors - with Vision Panel (290 X 590mm- Minimum). Landing Entrance-Automatic Power Operated Center Opening Vandal Proof Stainless Steel Doors - with Vision Panel (290 X 590mm- Minimum). Clear Opening-800 mm Wide x 2000 mm High. Indicators: Car & Landings-Direction & Position Indicator. Other Features-Battery Operated Emergency Light & Alarm Call Registration LED’s OSG Electronic Switch Infra-Red Light Curtain Door Safety Intercom System Handicap provision for Disable Persons Braille Buttons Fireman Drive - FRD Automatic Rescue Device – ARD Load Weight Device – LWD
SAND (UPTO 8KM LEAD)
CHIPS (UPTO 22KM LEAD)
METAL (UPTO 22KM LEAD)
BRICKS (UPTO 8KM LEAD)
Providing and laying RCC Pipe NP 4 heavy duty non presure pipe 900 mm dia with spigot all complete as per direction E/I
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. 19.6.2- R.C.C. pipe
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge
Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge
DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates) Drilling upto 30 mtr. Depth below G.L. in Rural Area
Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
(c) From126.0 M to150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 5 HP
Providing and fixing D.O.L. starterwlth SS Enclosure wlth 380/41S Volt coil
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
HVAC WORK
Supplying, installing, testing and commissioning of Air Cooled Ducted Air conditioners suitable for R410A or eco-friendly refrigerant with evaporating unit comprising of cooling coil, blower with motor in Metallic (Steel) casing and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, Expension kit to connect with DX AHU (If Required), and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting.
Providing, fixing and testing of copper refrigerant piping of appropriate sizes duly insulated with nitrile rubber insulation of 19 mm thickness. The pipes plus nitrile rubber insulation and cable are to be covered with PVC flexible conduits for protection.
Note: Providing and fixing of Powder coated M.S. angle iron frame work/Masonary Pedastal with required anti-vibration mounting for outdoor unit is also included in the above scope. Contractor to submit design/Scheme for Iron frame and obtain approval of engineer/employer before proceeding purchase & installation.
Nitrogen pressure testing for refrigerant pipe leakages & flushing during installation & after commissioning between IDU & ODU shall be done. During brazing an inert gas (such as nitrogen) shall becontinuously passed through the system at a rate sufficient to maintain an oxygen free environment to prevent the formation of copper oxide scale.
Necessary corrosive treatment of copper coil of the ODU with Aluminium hydroxide, 25 microns thickness or equivalent coating as per manufacturer standard to protect from corrosion, sulfur and other chemical contaminants present in the air. The coating should be done in the presence of OEM represantative. The coating shall be carried-out by the authorized applicator of coating manufacturer.
3.0 TR (1200 CFM)
4.0 TR (1600 CFM)
5.5 TR (2200 CFM)
8.5 TR (3400 CFM)
11.0 TR (4400 CFM)
Supply , installation, testing & Commissioning of ceiling suspended DX type split AC units with air cooled condenser complete with 5 Star Inverter type scroll/rotary compressor ,condenser ,wiring & accessories . Indoor units shall be ceiling suspended/wall mounted type complete with evaporator ,fan, filter ,drier, expansion devices & microprocessor control panel along with all accessories with refrigerant & oil charge , corded remote controls. The unit shall be suitable for working at 240 ± 10% ,50 Hz,1 phase AC supply .The unit shall be designed to take care of minimum vertical head 5mt & horizontal length of 30 mt & necessary oil separator shall be included ,Necessary supporting arrangement for both indoor & outdoor units ( Powder Coated /Epoxy painted MS stand for ODU units as per approved make, shade by Architect) with necessary vibration isolation arrangement as per site condition etc. (without condensate drain pipe ,electrical power & control cabling between indoor & outdoor unit which shall be paid separately ).
The coil in the outdoor units shall be provided with anti corrosive treatment. Necessary corrosive treatment of copper coil of the ODU with Blygold PoluAl (Aluminum hydroxide, 25-microns thickness) to protect from corrosion, sulfur and other chemical contaminants present in the air. Coating should be done in presence of OEM representative. The coating shall be carried-out by the authorized applicator of coating manufacturer.
The Outdoor unit Compressor must be provided with 5 Year Warranty Period.
Silver Ion Filter, Dust Filter
Civil Work such as wall hole making , wall chiseling ,refilling of chiseling part with mortar etc. as per site condition.
Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts
Removable Covers for all indoor & Outdoor units shall be supplied & put on the units after installation & commissioning.
Incoming power supply shall be provided near each indoor units
1.5 TR (475 CFM)
2.0 TR (625 CFM)
Supply, installation, testing and commissioning of Scheduled Timer for wall mounted split type Air conditioning units.
Supplying, installing, testing and commissioning of Shielded control cum transmission wiring of 2 core x 1.5 sqmm copper FRLSH, XLPE insulated cable in suitable GI conduits accessories between indoor and outdoor units. Necessary securing of conduit shall be made by contractor. After completion of work wall and floor shall be repaired and brought to its original finish. The rate will also include cost of laying of GI conduit between indoor and outdoor units.2C x 1.5 Sq mm (Shielded-Unarmored)
Supply, fixing, testing and commissioning of interconnecting soft/hard drawn copper refrigerant pipe work of following outer diameter duly insulated with fire rated class'O' closed cell elastomeric nitrile rubber type tubular insulation (19mm/13mm thick) between indoor & outdoor units & protected with 28 G aluminium sheet cladding as per specifications. All piping should be laid on Galvanized/Powder Coated tray supported by Galvanized M S Hangers & Clamps and all external piping shall run in covered cable trays. The rate includes all the items required to complete the piping work and nothing extra should be payable except the cable tray.
Vaccumiazation & Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU.
Civil Work such as wall hole making , wall chiseling ,refilling of chiseling part with mortar etc. as per site condition.
6.4 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
9.5 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
12.7 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
15.9 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
19.1 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
22.2 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
28.6 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
Providing and fixing of cPVC drain water piping complete with fittings, flexible connection to IDU, necessary support as per specification and insulated with 6 mm thick fire rated class'O' closed cell elastomeric nitrile rubber insulation.
25 mm dia
32 mm dia
Supply, installation, testing, commissioning of Inline fan with vibration isolators, speed regulator, GI gravity louvers, Bird Screen and required cable as per specification and drawing. The Motor shall be suitable to run on 1 phase/50 hz/ 220 v electrical power Supply including fire retardant non-porous double layer flexible connection of the following capacity.
The louvers & bird screen shall be made of heavy gauge metallic construction.
600 CFM (1020 CMH) at 12 mm static pressure
1000 CFM (1700 CMH) at 15 mm static pressure
Supply, installation, testing and commissioning of wall mounted Propeller type heavy duty exhaust Fan of metallic construction complete with speed regulator, bird screen, gravity louvers, vibration isolators, required cable, plug & other accessories compete as required, suitable for single phase, 240± 10 volts, 50Hz AC. supply of following capacities:
The louvers & bird screen shall be made of heavy gauge metallic construction.
300 mm sweep dia (900 RPM)
380 mm sweep dia (900 RPM)
450 mm sweep dia (900 RPM)
600 mm sweep dia (900 RPM)
Supply, installation, testing & commissioning of Wall mounted Propeller type exhaust air fans of high grade ABS plastic construction complete with electric motor suitable for operation on 230 V+ 10%,50 Hz, 1 phase AC supply fitted with speed regulator, mountings frames, louvers and bird screen, required cable & plug to connect with socket etc. complete as required of following capacities.250 mm sweep dia
Supply, installation, testing and commissioning of factory fabricated Galvanized Steel (GSS) Sheet metal ducts complete with flanges, neoprene rubber gasket, elbows, Splitter Damper, vanes, hangers & support etc. as required as per IS/DW144/SAMACNA standard & confirming to specification. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications.
Note : Splitter Shall be a part of ducting.
0.63 MM (24 Gauge )
0.80 MM (22 Gauge )
1.00 MM (20 Gauge )
1.25 MM (18 Gauge) Plenum
Supply, Fabrication, installation and testing of Galvanized Steel (GS) sheet metal ducts & finally applying fire rated paint as per BS 476 Part 24 (Site FABRICATED DUCTS For Connection /Plenum etc.) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, etc., as per specifications.
Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006
0.63 MM (24 Gauge )
0.80 MM (22 Gauge )
1.00 MM (20 Gauge )
1.25 MM (18 Gauge) Plenum
Supplying , installation, testing & commissioning of external thermal insulation on ducts with duly laminated aluminum foil of mat finish Closed Cell Elastomeric Nitrile Rubber Insulation of density not less than 50±5 Kg/m³ & thermal Conductive not exceeding 0.032 W/mK at an average Temperature of 0°C and . The Material Shall be rated as Class 1 as per BS476 Part7 for surface spread of flame test and Class O as per BS476 part6 for fire propagation test. The Material shall have Fire Approval from CBRI - Roorkee & no toxicity under flaming and non- flaming condition as per AITM 3.000 (1993). Adhesive used for setting the insulation shall be non - flammable, Vapour Proof. All Joints should be sealed with 3 mm thick 50 mm wide PE tape and Flange to be overlapped by 6" width of the same material thickness. Finally Duct insulated should be strapped by 12mm metallic Packing strip at every random meter & conforming to standard and Specification. 13 mm
Supply and fixing of acoustic lining of supply air duct and plenum with thick Engineered Nitrile Rubber open cell foam having a Noise Reduction Coefficient of 0.55 with Density 160 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.
Acoustic lining in ducts/plenum up to 3.0 Running meter from Fan Outlet as per specification and drawings.
20 mm For Duct
25 mm For Plenum
Supply,. Installation, testing and commissioning of 18 Gauge G.I construction Frame with 22/24 Gauge GI Aero foil blades Volume control Duct/Wall Dampers with linkages, levers & fittings for Controlling the Airflow in Ducts with neoprene rubber gaskets,nuts, Bolts, Screws Linkages, Flanges etc. as per specification.
Supply. Installation, testing and commissioning of powder coated extruded aluminium section grills with aluminium dampers for supply air terminal and grilles without damper for return air for air-conditioning as per specification.
Grilles with Dampers
Grilles without Dampers
Supply. Installation, testing and commissioning of powder coated extruded aluminium square diffusers with antismudge ring and removable core.
Supply/Exhaust air with dampers
Return air without damper
Supply. Installation, testing and commissioning of thermal flexible aluminum duct of following sizes duly supported at regular interval as per site requirement & spefications.200 mm
Supply. Installation, testing and commissioning of slot diffusers with/without damper as specified below and as per specification.
3-Slot Diffuser
2-Slot Diffuser
Supply. Installation, testing and commissioning of powder coated extruded aluminum Linear Grille.150 mm
Supply and fixing of non vision air transfer door grille of powder coated extruded aluminium, single deflection grille with horizontal vanes arrangement etc. as per specifications and drawings.
Supply, Installation, Testing and Commissioning of Fresh Air/Exhaust air Louvers minimum 80 mm deep comprising of inclined blade and extended-out lowest blade for disposal of rain water including the wire mesh, filter (washable type filter section Class-G3 having efficiency >80% down to 20 micron fitted in aluminium frame) . The louver shall be of extruded Aluminum construction, and powder coated to the approved finish and color.
Providing and Fixing Underdeck Insulation with 50 mm thick with closed cell Nitrile Rubber with prelaminated Aluminum foil on one side having a low stable k value of 0.035 k.cal/hr.m at 10.C and minimum density of 40-55 ± 3 kg/cum.The R-value should be as per ECBC Code.50mm
Supply, Installation, Testing & Commissioning of following Switchgears as an Isolator in IP-65 rated in power coated 16 SWG sheet steel enclosure .
40A 4P MCCB(25 KA)
63A 4P MCCB(25 KA)
Supply and laying ,testing and commissioning of following sizes of Copper conductor control cables with PVC conduit & fixing clamps and effecting proper connections to equipment etc. of following sizes :
4C x 10 Sq. mm Copper Conductor (Armoured)
4C x 6 Sq. mm Copper Conductor (Armoured)
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply & laying 25x5mm GI strip at 0.5mt below ground as strip earth electrode including connection/terminating with GI nut,bolt,spring,washer etc. as required.) jointing shall be done by overlapping &with 2sets of brass nuts bolt spring washer spaced at 50mm).25mm x5mm
PLUMBING WORK
Providing and fixing male ended 15 mm dia brass bib cock of approved quality ( wt not less than 350 gms ) with extra socket all complete as per specification and direction of E/l .
Providing and fixing 15 mm dia male ended C.I .Body brass spindle valve and seat bib cock of approved quality (wt not less than 400 gms ) with extra socket all complete as per specification and direction of E/l .
Providing and fixing 15 mm dia male ended C.I push cock (wt not less than 400 gms ) of approved quality with extra socket all complete as per specification and direction of E/l .
Providing and fixing brass / C.I. Stop cock of approved quality all complete as per specification and direction of E/l .
A) BRASS STOP COCK
(a) 15 mm dia
(b) 20 mm dia
Providing and fixing 15 mm dia and 45 cm. long P. V .C connection pipe with heavy quality brass coupling at both ends etc. all complete as per specification and direction of E/l .
Providing and fixing 15mm size C.P brass pillar cock (Weight not less than 350 gms) C.I body brass spindle pillar cock of approved quality as per spcification and direction of E/l.(b) C.I. body brass spindle
Providing and fixing Gun metal full way valve of approved qualtiy, all complete as per specification and direction of E/l
(a) 15 mm dia wt not less than 300 gms
(b) 20mm dia wt not less than 400 gms
(c) 25 mm dia wt not less than 500 gms
(d) 32 mm dia wt not less than 700 gms
(e) 40 mm dia wt not less than 1kg
(f) 50 mm dia wt not less than 1.5 kg
Cutting drain width wise above G.L for laying G.I pipes and restoring with brick in cement mortar (1:4) 12mm cement plaster in (1:4) with neat cement punning as per specification and direction of E/l
Supplying tools and making connection of new G.I. distribution branch 15 mm to 50 mm dia with existing G.I main by providing and fixing G.I. tee including cutting of pipe at two places and threading their ends, providing long screw and G.I nipple all complete as per specification and direction of E/l. (f) 50 mm dia
(b) Mirrors of 6 mm thick plate glass bevelled edge mirror including C.P brass revolving fittings, 3 mm plywood board and C P hinges to fix with mirror.
Supplying materials and construction of brick masonry drain 150 mm width and 150mm depth with 250mm apron on both sides over 50mm thick P.C.C (1:3:6) over a brick flat soling, apron laying brick work in C.M (1:6). 12mm cement plaster (1:3) with punning on exposed surface all complete job as per specification and direction of E/l
Supplying materials and construction of 600x600x900mm stop cock chamber of brick masonary with 125mm thick work of designation 75B in cement mortar (1:6) with 12mm thick cement palster in C.M. (1:6) on inside only.having 50mm thick R.C.C. cover having 12mm dia lifting rings, 2 nos. stop cock chamber will rest over 80mm thick P.C.C. (1:3:6) over one brick flat soling, including cost of earthwork, all complete job, as per approved design, specification and direction of E/I.
Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with "p" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (a)12.5 lit. low level P.V.C. cistern
Supplying, fitting and fixing white glazed fire clay sink of approved make with overflow arrangements supported on C.l. or R.S. painted brackets 40 mm dia C.P. brass waste with C.P. brass chain and rubber plug, 40 mm dia P.V.C. waste pipe about 750mm long with brass coupling at one end and 15 mm C.I. body brass spindle bib cock of approved quality of weight not less than 450 grms. including cutting wall and making good the same etc. all complete as per specification and direction of E/l. (b) Kitchen sink of size 600 mm x 450 mm x 250 mm
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Supplying fitting and fixing H.C.I, pipes with ear of approved make confirming to I.S.I. 1729 including supplying nails and bobins short pieces, cutting loose collars, lead and yarn for making lead chaulked joints, cutting pipes to size including earth work or scaffolding where neccessary etc. all complete as per specification and direction of E/l.
(a) 100 mm dia
(b) 75 mm dia
(c) 50 mm dia
Supplying and fixing H.C.I, fittings of approved make confirming to I.S.S. 1729 including supplying nails and bobins lead and yarn for making lead chaulked joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/l.
(A) H.C.I, single junction with door but without ear except socket
(i) 100mmdia(Wt. 10.5 Kg. app.)
(ii) 80 mm dia (Wt. 7 Kg. )
(B) H.C.I. Heal Rest Bend
(i) 100 mm dia (Wt. 5.5 Kg. app.)
(ii) 80 mm dia (Wt. 4 Kg. app.)
(iii) 50mm dia (Wt. 3.5 Kn. app.)
(G) H.C.I, bend with door and ear
(i) 100 mm dia (Wt. 6.5 Kg. app.)
(ii) 80 mm dia (Wt. 4.5 Kg. app.)
(iii) 50 mm dia (Wt. 4 Kg. app.)
(H) H.C.I plain bend with ear
(i) 100mm dia (Wt. 5.5 Kg. app.)
(ii) 80 mm dia (Wt. 3.75 Kg. app.)
(J) Floor trap with gratings
(i) 100 mm dia
(K) Norton patent H.C.I, cowl
(i) 100 mm dia (Wt. 3.25 Kg. app.)
Making holes in wall for laying H.C.I, pipe and restoring the same after pipe laying as per specification and direction of E/l.
(i) 125 mm dia
(ii) 250 mm dia
Supplying materials and labours for painting the exposed H.C.I, pipes and fittings with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l.
(i) 50 mm dia
(ii) 80 mm dia
(iii) 100 mm dia
Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion.110mm dia
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion.
Coupler 110 mm dia
Single Tee with door
Bend 87.5 deg 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion.PVC Shoe
Providing and fixing unplasticised- PVC pipe clip of approved desing to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwes with M.S. Screw of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse sand ) and making good the wall etc. complete.110mm dia
Providing and fixing white vitreous china battery based infrared sensor operated urinal of appx.size 610x390x370mm having pre & post flushing with water (250ml & 500ml consumption) having water inlet from back side,including fixing to wall with suitable brackets all as per manufacturers specification & direction of Engineer-in charge.
Providing and fixing C.P. bass angle valve for basin mixer and geyser points of approved quality conforming to I.S:8931.15 mm nominal bore
Constructing brick masonry road gully chamber 50 X 45 X 60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500 X 450 mm precast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5.
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) with pre-cast R.C.C. vertical grating complete as per standard design: With common burnt clay F.P.S.(non-modular) bricks of class designation 7.5.
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) including 500x450mm pre-cast R.C.C. horizontal grating with frame & vertical grating complete as per standard design: With common burnt clay F.P.S.(non-modular) bricks of class designation 7.5.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighting not less than 440 grams.
Polythene water storage tank of mark with cover and Suitable locking system in double layer confirming to JS: 12701-1996 Per Litre 6.75 with latest revision.
NP2 R.C.C Hume Di De with ·collar as =r I.S.S.458-1971 (ii) 150 mm dia
NP2 R.C.C Hume pipe with collar as per I.S.S.458-1971 (ivl 250 mm dfa
NP2 R.C.C Hume oioe with coltar as ner I.S.S.458-1971 M 300 mm dia
Labour for laying, fitting and fixing NP2 R.C.C. spun pipe with collars in lines, level and grade and providing approved jointing materials and joints properly filled lo make them leak, proof including_ providing sight rails, bonning rod, night guard, Red light and barrier gtc. all complete as per specificaUon and direction of E/1.
150 mm. dia. RCC Pipes
250 mm. dia. RCC Pipes
300 mm. dia. RCC Pipes
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) upto haunces of SW pipes including bed concrete as per standard design. 300 mm. dia. RCC Pipes
Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design.
Inside size 90 x 80 cm and 45 cm deep including CI cover with frame(medium duty) 500mm internal diameter, total weight of cover and frame to be not less than116 kg (weight of cover 58 kg and weight of frame 58 kg).-With FPS bricks of class designation 75.
Providing M.S. foot rests including fixing in manholes with 20*20*10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) as per standard design : with 20 x 20 mm square bar
Providing and fixing square mouth SW gully trap class SP-1 complete CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.7 kg. as per standard design. 180x150mm size P type With common burnt clay F.P.S (non modular) bricks of class designation 7.5.
Providing and fixing wash basin with CI brackets,15mm brass pillar taps,32mm CP brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required. White vitreous china wash basin size 630 mm x 450 mm with a single 15mm CP brass pillar tap.
Special type of C.P. Bath room fittings for V.I.P. Buildings (JAL, Jaquar, Marc or equivatent make) (ISi Marked) (xv) Sink mixer with swinging casted spout {ISi Marked
Providing and fixing G.I. Inlet fitting of suitable size with 1 to 3 Nos. G.I. Sockets of 32 to 50 dia welded to G.I. pipe 100mm dia and dipped in hot bitumen complete in all respect.
Providing & fixing 100m x 50mm G.I. waste with G.I. reducer including 102mm dia CP Glossy Grating Jayna model no. RRB 102),cutting chases in the floor / slab complete as required.
Providing and fixing brass clean out plug with suitable inlet key for opening male threaded joint with pipe & socket complete as required.
Supply, installation, testing and commissioning built with Drinking Water R.O. unit with micron filtration pre-treatment unit, skid mounted R.O. module with pressure pump and pressure tank, drinking water cooler (High quality SS Tank for Storage 80 lts) , complete in all respects. ( Make & Model No. Eureka Forbes Pure Chill RO Storage Cooler cum Purifier or Equivalent)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil,Pipes, cables etc, not exceeding 80 mm dia.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. .
Internal Work - Exposed on Wall
15 mm nominal outer dia pipes.
20 mm nominal outer dia pipes.
25 mm nominal outer dia pipes.
32 mm nominal outer dia pipes.
40 mm nominal outer dia pipes.
50 mm nominal outer dia pipes.
Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the the same including testing of joints complete as per direction of engineer in charge.
Concealed work including cutting chases and making good the walls etc.
15 mm nominal outer dia pipes.
20 mm nominal outer dia pipes.
25 mm nominal outer dia pipes.
32 mm nominal outer dia pipes.
40 mm nominal outer dia pipes.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc.
Internal work exposed on wall
15mm dia nominal bore
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
40mm dia nominal bore
50mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
External work
65mm dia. nominal bore
80mm dia. nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work.
15 mm diameter pipe.
20 mm diameter pipe.
25 mm diameter pipe.
32 mm diameter pipe.
40 mm diameter pipe.
50 mm diameter pipe.
Painting G.I. Pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality:
15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
Providing & fixing G.I. union in G.I. Pipe including cutting & threading the pipe & making long screws etc. complete( New work):
15mm dia. nominal bore
20mm dia. nominal bore
25mm dia. nominal bore
32mm dia. nominal bore
40mm dia. nominal bore
50mm dia. nominal bore
65mm dia. nominal bore
80mm dia. nominal bore
Providing & wrapping burried G.I. pipes and fittings with 4mm thick pypcoat all around the pipe in external work.
15 mm diameter pipes
20 mm diameter pipes
25 mm diameter pipes
32 mm diameter pipes
40 mm diameter pipes
50 mm diameter pipes
65 mm diameter pipes
80 mm diameter pipes
Providing and fixing M.S. puddle flanges fabricated out of 6 mm thick M.S. plate of size 200 x 200mm plus dia of pipe of 600 mm long pipe pieces to R.C.C. water tanks / R.C.C. walls. The entire fitting shall be painted with black Japan paint .
25 mm dia
50 mm dia
65 mm dia
80 mm dia
PUMP FOR WATER SUPPLY
DomesticWater Supply Pump at (UGT)
Set of Two Pumps (1 Working+ 1 Standby)
Capacity 2.0 LPS
Head 25 M.
HP 2.0 HP Approxi.
Earth Work in Excavation of required width for storm and sewer pipes including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil and then returning the soil as required in layer not exceeding 20 cms in depth including consolidating each deposited layers by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50 m. for all kinds of soil. All kinds of soil Pipes, exceeding 80 mm dia but not exceeding 300 mm dia.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :.
150 mm dia.
250 mm dia.
300 mm dia.
Constructing water tight brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement :4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size). Foundation concrete 150 mm thick 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size), inside and outside plastering 12 mm thick with cement plaster 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels and benching in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design,complete with SFRC cover Heavy duty of adequate size as per standard design and approved drawings . (Price shall include the, cost of excavation, back filling, disposal of surplus earth, dewatering & water proofing of manholes as directed at site & other associated civil works).
Inside size 1200mm x 900mm x 900 mm deep.
Extra over item No. 4 (b) for depth exceeding 90-250 cm.
FIRE FIGHTING WORKS.
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. d) Suitable cement concrete foundation duly plastered with anti-vibration pads.
Capacity : 2850 LPM Pump Head: 88 M App. HP : 60 HP
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) a) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Capacity : 2850 LPM Pump Head: 88 M
Jockey Pump Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) a) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. c) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Capacity : 180 LPM Pump Head: 88 M
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
INCOMING
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps
Set of Copper Bus Bar 300A
OUTGOING
Main Fire Pump
Jockey Pump
DIESEL ENGINE CONTROL
Control for diesel engine comprising -
Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication
All standard relays and accessories for automatic operation of diesel engine
System Controller
Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
250 mm dia (6.3mm thick)
200 mm dia (6.3mm thick)
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
150 mm dia
100 mm dia
80 mm dia
Providing, laying jointing & testing of NP-4 Class RCC pipe S/S jointed with stiff mixture in the proportion 1:2 (1 cement, 2 fine sand), R.C.C. Hume pipe for underground hydrant pipe at road crossings including collar pieces and filling inside of pipe with sand complete as required Cost shall inclusive of earth work in excavation, dewatering and shuttering work complete. (For road crossing) 300 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
200 mm dia
150 mm dia
65 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
40 mm dia
65mm dia
150 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing and fixing of dial type (150 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI with no Syphon. Cost shall be inclusive of providing any short pieces, nipples, elbows etc. as required.
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
150 mm dia
80 mm dia
Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926.
Providing & fixing controlled percolation fire hose pipe (as per IS:8423) of 63 mm dia and 15 meter length rated for brust pressure of 3.5 Kg/sqcm. The hose shall be tested for flame resistance test in accordance to IS:8423. Hose shall be complete with ISI marked SS male & female coupling (IS:903) bound & riveted to hose pipe with copper rivets & 1.5 mm copper wire as required as per specifications. (Location : External fire hydrant).
Providing and fixing weather proof lockable cabinet of size not less than 750 x 600 x 250 mm made out of Mild Steel sheet of 2 mm thickness having central opening and 4 mm thick glazed glass doors (Two No.) suitably marked on the outside with the letters "FIRE HOSE" including necessary locking arrangement and shall be painted with one coat of primer and two coats of stove enamel paint of approved shade. (The aesthetics and design of the cabinet shall be as per the architect / Client). (For External Hydrant).
Providing and fixing 25 mm dia inspecting & testing assembly with gunmetal isolation valve, gunmetal sight glass, bypass valve & connected to drain line complete (excluding the cost of drain pipe).
Providing, fixing, testing & commissioning of annunciater Panel for flow control switches, providing Audio/visual Indication of actuation of Automatic sprinkler system for each zone complete as per specifications. The panel should have interface for connection to complete controlled building management system. The panel should have : a) Fault indication for each zone. b) indication of zone fire c) Fire/fault hooter. d) Alarm Panel for fire/fault. e) Battery for emergency. f) Battery charger. g) Mains supply. Annunciation Panel for minimum 100 Zones working + 20 zones spare
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (Exact quantities will be measured as per site conditions). 25 mm dia
Providing and laying in MS conduit FRLS insulated ISI marked copper control cable in existing conduit (IS:694) from individual flow switches from basement ceiling to annunciation panel installed in fire control room including sleeves cable clips, supports for horizontal runs etc. complete of size (Exact quantities will be measured as per site conditions). 2 x 1.5 mm
Providing & fixing single acting Air release valve with brass gate valve, flanges/ union, suitable for wet riser system with all necessary connections complete with all accessories as required and conforming to IS : 12992 (Part 1).
100 mm dia. Stainless Steel fire brigade draw out collecting head with 63 mm diameter instantaneous male draw out arranged at a suitable point at street level. This draw out shall be connected to galvanized iron pipe of 100 mm diameter with foot valve arrangement in the tank for Fire Brigade.
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)
Supplying & fixing 63 mm dia short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 b) 20 mm nominal internal dia gun metal globe valve & nozzle. c) Drum and brackets for fixing the equipmets on wall. d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 Meter length
Supplying, installation, testing and commissioning of weather proof M.S door and glass fire door size 2100 mm x 900mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mm x 40mmx6mm complete with glass, locking arrangements to accommodate the following: -
a) single headed Hydrant valve - 1 No. b) Fire Hoses 63mm, 15 M long with accessories - 2 Nos. c) Short branch - 1 No. d) First Aid hose Reel - 1 No. e) Fire Extinguisher - 2 Nos. f) Fireman's Axe - 1 No. g) Pressure Gauge - 1 No. The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
2 way-100 mm dia M.S. Pipe
4 way - 150 mm dia M.S. Pipe
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent Sprinkler
Upright Sprinkler
Horizontal side wall sprinkler
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150mm dia
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
Constructing masonry Chamber 1200 x 1200 x 2000 mm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Gate valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (For External Hydrant system). With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and fixing GI floor drain with 65mm x 50mm Elbow with cement mortar, complete in all respect (For FHC Drain)
Providing and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels etc.) including cutting to size, drilling, welding, including cost of fasteners, clamps in RCC structural members as directed, including two or more coats of synthetic paint over one coat of primer after surface preparation including cutting and making good walls (Structural other than pipe support).
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 and amended upto date finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge with CO2 gas conforming to IS : 307-1996..Capacity 4.5 kg. I.S.I. Marked. (IS : 15683 : 2006 and amended upto date)
Providing and fixing ABC stored pressure dry chemical powder Fire Extinguisher IS : 15683 and amended upto date latest revision manufacturer and of CRCA sheet in welded construction, finish with High quality epoxy polyester powder coated complete with brass forged ball valve, gun metal cap and nozzle, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases). Capacity 6 Kg (IS : 15683 : 2006 and amended upto date)
Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized steel sheet, standard 9 litres capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets.
EIECTRICAL WORK
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required Group C
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
CIRCUIT / SUBMAIN WIRING
2x1.5 sq mm + 1x1.5 sq mm earth wire
2x2.5 sq mm + 1x2.5 sq mm earth wire
2x6 sq mm + 1x6 sq mm earth wire.
2x10 sq mm + 1x6 sq mm earth wire.
2x16 sq mm + 1x6 sq mm earth wire.
4x2.5 sq mm + 2x2.5 sq mm earth wire
4x6 sq mm + 2x6 sq mm earth wire.
4x10 sq mm + 2x6 sq mm earth wire.
4x16 sq mm + 2x6 sq mm earth wire.
Supplying and drawing Following pair 0.5 mm dia FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20mm dia
25mm dia
32mm dia
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps one way switch
15/16 amp one way switch
5/6 amp 3 pin socket outlet
5/16 amp 6 pin socket outlet
Telephone Socket Outlet
TV anteena Socket Outlet
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet.
4/5 Module (78mm x140mm x 50mm)
6 Module (78mmX205mmx50mm)
8/9 Module (78mmX230mmx60mm)
12 Module (135mmX205mmx60mm)
Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing Ding dong sound call bell single phase, 230 volts, complete as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc. as required.
Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan, making good the damage, connection, testing, commissioning etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (For UPS Supply)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
20mm dia
25mm dia
Supply & drawing following sizes of FR PVC insulated copper conductor single core cables in existing surface/recessed steel / PVC conduit including dismantling as required.
2 x 1.5 sq.mm
3 x 2.5 sq.mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 Way Double Door
12 Way Double Door
Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 Way (4+18), Double Door Horizontal Type
8 Way (4+24), Double Door Horizontal Type
Supplying and fixing following ways surface / recess mounting Vertical type 415 Volts TPN MCB distribution board, of sheet steel dust protected duly power painted inclusive of 200 Amps tinned copper bus bar common, neutral link, earth bar, din bar, for mounting MCB's (But without MCB's and incomer) as required. ( Note:- Vertical Type MCB TP DB is normally used where 3phase outlets are required.
8 Way (4+18), Double Door Vertical Type
12 Way (4+24), Double Door Vertical Type
Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required.
6 / 32 Amp Single Pole
40 Amp DP
50/63 Amp DP
6/32 Amp TPN
40 Amp TPN
50/63 Amp TPN
Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing of following rating double pole ( Single pole & neutral), 240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required.
Providing and fixing M.V. danger Notice plate of 200mm x 150 mm of made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird
Providing and fixing H.T. danger Notice plate of 250mm x 200 mm of made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required.
Providing and fixing 50 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing of lighting conductor finial made of 25 mm dia 300 mm long, GI tube having single prong at top with 85 mm dia 6mm thick G.I Base plate including hole etc. as required
Providing and fixing GI Tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required. (for Horizental Run)
Providing and fixing GI Tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required. (for Vertical Run)
Providing and fixing testing Jointing made of 20mmx 3mm thick G.I Strip 125 mm Long. With 4 nos of G.I bolts. Nuts chuck nuts and spring washers etc. as required
Providing and Laying G.I tape 32mm x 6mm from earth electrode directoly in ground as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
INSPECTION CHAMBER:
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
2 run of cable
3 run of cable
Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforming to IS-7098. (Part-I).
3.5 core, 300 sq.mm.
3.5 core, 240 sq.mm.
3.5 core, 185 sq.mm.
3.5 core, 150 sq.mm.
3.5 core, 120 sq.mm.
3.5 core, 95 sq.mm.
3.5 core, 70 sq.mm.
3.5 core, 50 sq.mm.
3.5 core, 35 sq.mm.
4 core, 16 sq.mm.
4 core, 10 sq.mm.
4 core, 6 sq.mm.
2 core, 16 sq.mm.
2 core, 10 sq.mm.
2 core, 6 sq.mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with cable tie)
Above 35 sq. mm and upto 95 sq. mm (clamped with cable tie)
Above 95 sq. mm and upto 185 sq. mm (clamped with cable tie)
Above 185 sq. mm and upto 400 sq. mm (clamped with cable tie)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 x 6 sq. mm (19mm)
2 X 10 sq. mm (19mm)
2 X 16 sq. mm (22mm)
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (50mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70mm)
4 X 10 sq. mm (25mm) including 4x6 sq.mm
4 X 16 sq. mm (28mm)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required
125 A 15kA SC for 1 sec (including 100A)
200 A 25kA SC for 1 sec
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes cubicle panel, making connections, etc. as required.
100 A, 25 KA,TPMCCB
200 A, 25 KA,TP MCCB
MAIN L.T. PANEL WITH PLC BASED LOAD MANAGER Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type Main L.T. Panel with PLC based load manager, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable as required.
All incoming & outgoing MCCB's shall be microprocessor based with O/L & S/C and E/F protection.
All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link.
The breaking capacity specified for all ACB's and MCCB's breakers is Ics value (service rating).
Each section of Panel shall have door opearted light of sufficent lux to illumunate that section & each section of capacitor, buscoupler, transformer and DG incomers shall have exhaust fans for ventilation purpose.
All Energy Analyser / TVM Shall have RS 485 Modbus RTU on board Communication protocol for SCADA communication.
INCOMERS from 1 Nos. 1000 KVA TRANSFORMER
1 nos. 1600 AMP. Four Pole, Electrically operated 3 position motorized (220 V AC) drawout type Air Circuit Breaker with all inbuilt protections, with microprocessor based release, over current, earth fault, short circuit, Instantaneous short circuit, closing coil (220 V AC), trip coil (24 V DC), shunt trip release, inbuilt U/V release with LCD / LED display for event history with intruppted current value during fault & measurement of current parameters, 50 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947
The ACB shall be electrically interlocked with the bus coupler, DG incomers and other transformer incomers.
1 nos. 30 KVAR capacitor bank with 100 amp TP MCCB (35 KA) for each transformer incomer.
1 nos. 32 amp TP MCCB (35 KA) for OLTC (for each transformer incomer)
Protection releases / relays, Metering & Accessories for each Transformer incomers
Surge Protection Device - Type - 01 (Class - B), 10/350 µ sec. (100 / 25KA)
Over Voltage / Under Voltage relay / release (3 phase) with timer.
Backup earth fault relay.
Restricted earth fault relay.
There shall be a provision : - If REF operates, they send a signal to Upstream HT breaker of Transformer incomer ( in HT Panel) to make it "OFF" for protection of transformer.
Master trip relay.
Trip Circuit Supervison relay.
TNC switch.
1 set of 3 CT's of ratio 1600/5A, Class 1.0 accuracy 15 VA burden for metering.
1 set of 3 CT's of ratio 1600/5A, Class 1.0 accuracy 15 VA burden for APFCR.
1 set - 415 / √3 / 110 / √3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse.
1 no. CT's of ratio 1600/5A, Class 5P20 for protection.
1 set of 4 CT's of ratio 1600/1A, Class PS for protection.
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.
Power factor meter.
Frequency meter.
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup MCB.
INCOMERS from 2Nos. 400 KVA D G sets.
1 nos. 800 AMP. Four Pole, Electrically operated 3 position motorized drawout type Air Circuit Breaker, with all inbuilt protections, with microprocessor based releases/relays, over current, earth fault, short circuit, Instantaneous short circuit, shunt trip release, closing coil (220 V AC), trip coil (24 V DC), inbuilt U/V release with LCD / LED display for event history & measurement of current parameters with intruppted current value during fault , 50 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947.
Protection releases / relays, Metering & Accessories for each D G set incomers
Over Voltage / Under Voltage relay / release (3 phase) with timer.
IDMT earth fault relay.
Backup earth fault relay.
Master trip relay.
Trip Circuit Supervison relay.
Reverse power relay.
TNC switch.
1 Set - 415 /v3 / 110 / v3 Volts PT Class 1.0 accuracy and 100 VA burden along with primary & secondary MCB.
1 set - 3 CTs of ratio : 800/5A , Class 1.0 accuracy 15 VA each burden for metering.
1 set - 3 CTs of ratio : 800/5A , Class 5P20 accuracy 20 VA each burden for protection.
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.
Frequency meter.
Power Factor meter.
1 No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing.
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB along with hooter, auxillary relay, 2 sets of push buttons.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.
12 window annunciator with accept / reset / test push button for each DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares.
Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop.
Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps.
D G control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out.
1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (400 KVA)
Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same.
The ACB shall be electrically and mechanically interlocked with the bus coupler and Transformer incomers.
BUSCOUPLER
1 nos 800 AMP. Four Pole, Electrically operated 3 position motorised (220V AC) drawout type ACB's, closing coil (220V AC), trip coil (24V DC), with inbuilt U/V release 50 KA Breaking Capacity with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:13947-2.
The bus coupler shall be electrically interlocked with all incoming ACB's in such a way that at any one time two supply should not get mixed up.
BUS BARS
Bus Bar Make :- HINDALCO / JINDAL.
2000 AMP TPN busbars of aluminium alloy as per SLD.
PLC for load management / automation
Design, manufacturing, testing at works, supply of PLC BASED , AUTOLOAD TRANSFER, AUTOLOAD BALANCING PANEL FOR 2 nos. 400 KVA D.G. sets complete as required to acheive the desired functions. (Make : ALLEN BRADLEY / SIEMENS / MITSUBISHI / ABB)
PLC shall be provided in main LT panel for interlocking between different incomers and bus couplers to avoid unintentional paralleling of different supplies.
PLC shall have with VIEW PANEL
In addition to required hardware and software following components shall also be provided.
Based on the load requirement only required no. of DG sets shall be operated.
Monitoring of DG set safeties (mechanical as well as electrical).
PLC Hardware as required
Auxiliary relays/contactor/metering/protection etc as required
230 V AC, UPS of suitable rating
Annunciators as required
All control wiring from PLC to various feeders with min. of 2.5 sq mm copper FRLS cable.
OUTGOINGS:
05 Nos. 630 Amp TP Moulded Case Circuit Breaker (35 KA)
02 Nos. 400 Amp TP Moulded Case Circuit Breaker (35 KA)
02 Nos. 250 Amp TP Moulded Case Circuit Breaker (35 KA)
08 No. 200 Amp TP Moulded Case Circuit Breaker (35 KA)
12 No. 100 Amp TP Moulded Case Circuit Breaker (35 KA)
04 No. 63 Amp TP Moulded Case Circuit Breaker (35 KA)
Main L.T. Panel Described as Above.
AUTOMATIC POWER FACTOR CORRECTION PANEL (CAPACITOR PANEL)
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, testing & commissioning of 14 SWG CRCA sheet steel fabricated cubical type 300 KVAR A P F C Panel consisting of 5 /10 / 25 / 50 KVAR (at 415 Volts rated voltage of bank shall be 440 Volts) capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 42, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 .
All out going MCCB's shall be thermal-magnetic based with inbuilt O/L & S/C release.
AC3 duty contactors should be used for switching individual capacitor banks.
The fault withstanding capacity of panel & its control gear shall be min. 50 KA rms for 1 sec.
Each section of capacitor panel shall have Verticle hood & exhaust fans for ventilation purpose.
INCOMING
Incomer circuit breaker has been included in the main panel.
1 set- 3 CTs , ratio 600 / 5A Class 1.0 accuracy 15 VA burden for metering.
Micro processor based automatic power factor control relay (3 phase) (including power factor meter) in 12 steps for automatic cut off or add on capacitor units to keep the power factor at 0.95 with variation of loads. All associated auxiliary contactors / relays shall be provided with in the scope of work.
Phase indicating lamps with HRC fuses, and indicating in each capacitor chamber unit to indicate On/Off status of capacitor unit.
BUS BARS
600 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coding and insulated by heat shrinkable sleeves and clips on shrouds for joints.
OUTGOINGS
3 nos. of 125 AMPS TPN MCB (35 KA) and 140 amps AC3 duty contactor with 50 KVAR, MPP resin filled, super heavy duty ,440 V capacitor bank, start stop push button for manual operation including on/off indicating lamps and delay timer complete.
5 nos. of 63 AMPS TPN MCB (35 KA) and 80 amps AC3 duty contactor with 25 KVAR, MPP resin filled, super heavy duty ,440 V capacitor bank, start stop push button for manual operation including on/off indicating lamps and delay timer complete.
2 nos. of 32 AMPS TPN MCB (35 KA) and 40 amps AC3 duty contactor with 10 KVAR, MPP resin filled, super heavy duty ,440 V capacitor bank, start stop push button for manual operation including on/off indicating lamps and delay timer complete.
1 no. of 16 AMPS TPN MCB (35 KA) and 20 amps AC3 duty contactor with 5 KVAR, MPP resin filled, super heavy duty ,440 V capacitor bank, start stop push button for manual operation including on/off indicating lamps and delay timer complete.
Capacitor Panel as described above
DISTRIBUTION PANEL
L+P PANEL (Warehouse-1)
INCOMING
1 No. 250 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
300 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
2 Nos. 63 Amp DP MCB (10 KA)
6 Nos. 32 Amp FP MCB (10 KA)
6 Nos. 40 Amp FP MCB (10 KA)
6 Nos. 63 Amp FP MCB (10 KA)
Main L.T. Panel Described as Above.
L+P PANEL (Warehouse-2)
INCOMING
1 No. 630 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
600 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
2 Nos. 63 Amp DP MCB (10 KA)
6 Nos. 32 Amp FP MCB (10 KA)
6 Nos. 40 Amp FP MCB (10 KA)
6 Nos. 63 Amp FP MCB (10 KA)
2 Nos. 160 Amp FP MCB (10 KA)
2 Nos. 100 Amp FP MCB (10 KA)
Panel described as above
UPS PANEL
INCOMING
1 No. 63 Amp DP MCB (10 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
100 Amp DP copper busbar with coloured heat shrinkable sleeve.
OUTGOING
06 Nos. 40Amp DP MCB (10 KA).
Panel described as above
L+P PANEL (OFFICE /LAB BUILDING)
INCOMING
1 No. 200 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
250 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
4 Nos. 63 Amp DP MCB (10 KA)
4 Nos. 40 Amp DP MCB (10 KA)
10 Nos. 32 Amp FP MCB (10 KA)
10 Nos. 40 Amp FP MCB (10 KA)
10 Nos. 63 Amp FP MCB (10 KA)
Main L.T. Panel Described as Above.
EXTERNAL LIGHTING PANEL (OUTDOOR TYPE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker (35 KA) with 100 Amp 4 Pole Contactor & Timer.
1 Set of phase indicating lamps.
1 Set of ON/OFF indicating lamps with SP MCB.
BUS BARS
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
16 Nos. 25 Amp DP MCB (10 KA)
03 Nos. 40 Amp FP MCB (10 KA)
Panel described as above
Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor PVC insulated cable including termination complete as required in existing cable tray.
1C x 50 sq.mm PVC Insulated cu wire including termination etc.
1C x 16 sq.mm PVC Insulated cu wire including termination etc.
Supply, erection, testing and commissioning of following sizes of TV splitter of aluminium die cast body in suitable size of G.I. Box. 4 way
Supply, erection, testing and commissioning of following co-axial cable in existing conduit. RG-11
Supply & installation of 32 Amp 3 phase, 415 volt, 50 Hz water tight (IP-55) socket outlet with interlocking switch complete with all fixing accessories.
Supply & installation of 32 Amp single phase 240 Volt, 50 Hz, water tight (IP-55) socket outlet with interlocking switch complete with all the fixing accessories as below.
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification.
100 mm wide x 40 mm deep.
200 mm wide x 40 mm deep.
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification.
150 mm wide x 50 mm deep.
250 mm wide x 50 mm deep.
Supply, Installation, Testing & Commissioning of Earthing Junction Box size - 400mm x 300mm x 80mm made out of 16 SWG CRCA sheet with seven tank process & powder coating, earthing link (32mm x 6mm copper strip) front door with glass as complete as required.
FIRE ALARM SYSTEM (ADDRESSABLE TYPE) AND PA SYSTEM
Two Loop Panel.
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector acclimate type sensetive level (0.524%) OVS/ft. complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or separete) complete with emitter and receiver including connections with remote test features complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. (75 DBA @3 mtr. & 75CD flashing)
Supply, installation, testing and commissioning of addressable monitor module complete as per specification.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 480 Watt, supply complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
Speaker cable Single pair, 2-core, 1.5 sqmm
S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100- 270 volt AC,50Hz. Luminarie shall be confirm tolS:,1,0322part-5/section-5 and shall be complete with all neccssary accessories as required (Make:- Havells/Philips/Crompton/Wipro.)
Providing fixing testing & commissioning of LED FLOOD Light 240W) complete with all accesries as required
120W LED Flood light
SITC of following rating recess / surface mounted LED round / square shape down light luminarie with pressure die cast housing for single phase supply voltage Luminarie shall be confirm to IS: 10322 part -5 / section -2 or IEC :62722 withh all neccesary accessories as required. (Make:- Havells/Philips/Crompton/Wipro.)
12W LED Round Down Light (Recess / Surface )
15 / 16 W LED Round Down Light (Recess / surface )
18 /20 W LED Round Down Light (Recess/Surface)
2' x 2' LED Panel Light (Recess / surface)
Bulk Head fitting with 9/10Watt LED.
S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required. (Make:- Havells/Philips/Crompton/Wipro.)
10/12 W LED Tube Light
20/22 W LED Tube Light
SITC of 300 mm (12") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. ( Make :- Usha/Crompton / Havells) .
SITC of 600 mm (24") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. ( Make :- Usha/Crompton / Havells) .
Supply Installation, Testing & Commissioning of following sizes ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard (up to 30cm) with 1.5 sq.mm FR PVC insulated copper wire suitable for 230V 50 Hz, Single phase supply etc. complete as required. (Make :- Usha/Crompton / Havells )
1200 mm ( 48") BLDC 5 Star rating 32W Ceiling Fan
450 mm (18") metal body wall fan with speed regulator suitable for sfuncle phase 220Y,50H2 AC supply
For 12 mtr. High mast: ITC of the high mast and light fixture with the help of suitable tools and plans, wiring of luminaries with all Wiring material like PVC insulate[Pvc sheathed flexible cable of suitlblb copper conductor lugs, MCB and all labour & construction of shallow foundation with M25 grade concrete for the high mast considering safe soil bearing capacity of 10T / mhs sq. for 12 M High mast.
Supply of 16mtr. High mast in two section Construction 5355 grade as per BIEN 10 025 Top Dia 15omm, bottom dia 360mm, plate thickness 3mm, 2Oside polygon, galvanisation as per BS EN ISO 1461, base plate dia 520mm, base plate thickness 25mm, GI single spike lighting protection, maximum wind speed 47 m/s with 6 nos foundation bolts of PCD tt45mm TS 600/ 24nm dia/850 mm long. Luminaries carriage : Material for 40 NB ERW Class B --M.S. Pipe, dia of carriage ring 450mq '6tO; -itt 8/72 arm,welded, 2 sekons having carrying capacity uptou 8/12 luminaries. Trailing Cable : 5 core 2.Ssq.mm. PVC flexible copper conductor Winch/Power Tool : Double drum, SWL 350 kg with 1HP 6 pole single speed integral motor Rope : Grade AlSl304,7 /19 construction, dia 5mm, BLC 1450 x 2 having 2 nos of continues rope. Aviation obstruction light: twin dome aviation obstruction lights LED Ityp" "t required. (But excluding lreeder Pillar)
UPS / INVERTER SYSTEM
10 KVA online UI€ single phase input and single phase output power system of input Voltage range 110V AC I 5% - 300V AC L 5"/o, Frequenry range 40Hz - 60FJ2, Power Factor > 0.90 @ full load, and outputVoltage range 200V /208/220/230/240V AC, Voltage regulation l1%, Frequenry range 50Hz t 0.25Hzot 60Hz t .30H2 Harmonic distrortion - < 2% TILD (Linear load) : 4% THD (non-liniear load) efficencv- 88/83"/"
MS battery rack suitable for 10 to 20 UPS Battery installation
SITC of 60 nos. 65 AH Flat type Sealed Maitanace Free (SMF) Battery with 24 months replacement warranty. IS:1652:1991. (VAH Required minimum 11700 for 10 KVA UPS (65AH x 15 Nos. x 12V = 11700 VAH)
Total cost of 1 Set 10 KVA UPS, Batteries & Accessories (A+B+C)
3000VA sine wave inverter input AC range-1O0V to 300V AC, wide- 90V to 300V AC, standard - 180V to 260V AC, DC range -1.0.5 toL4.2, efficiancv- 80%, protection-overload, Short circuit
Trolly for Double tubular Battery
150Ah tubular Lead acid battery with 36 month replacement guaranty. 15:1.652:1991.
DATA, TELEPHONE SYSTEM INCLUDING ACTIVE COMPONENTS
Supply, Installation, Testing & Commissioning of Cat 6, 24 Port Patch Panel
Supply, Installation, Testing and Comissioning of Cat 6 patch cord 3 feet for rack and user end termination - 1Mtr
Supply, Installation, Testing and Comissioning of Cat 6 patch cord 7 feet for rack and user end termination - 2Mtr
Supply, Installation, Testing, Commissioning of Cat 6, Information Outlet (I/O) including G.I. Box and modular cover plate.
Supply, Installation, Testing and Comissioning of 24U floor mounted Rack with accessories.
Supply, Installation, Testing & Commissioning of 24 port 10/100/1000Mbps, 4SFP module, L-2 Switch, POE.
Supply, Installation, Testing & Commissioning of EPABX SYSTEM Configuration as Below:- Analog Trunk Line 6 Nos. Digital Line 2 Nos Analog Extensions 75 Nos.
Supply, Installation, Testing & Commissioning of Digital Phone for Operator Console
Supply, Installation, Testing & Commissioning of Type Analog Phone with speaker phone, .
Supply, Installation, Testing & Commissioning of 6 Core OM4 Multimode Fiber Cable.
IP CCTV SYSTEM
Supplying, installation, testing & commissioning of 1080p HD Indoor IP Dome camera with1/3-inch CMOS, Sensor pixels 1920 x 1080, Sensitivity-0.04 lx (color) , Dynamic range 75 dB Wide Dynamic Range (WDR), True day/night, Automatic Electronic Shutter, Video compression H.264 ; M-JPEG, White balance, BLC, H.264 quad-streaming, Motion/tamper/audio detection, Privacy Mask, Lens 3.6 mm lens, 3-axis adjustment (pan/tilt/ rotation), ONVIF Profile S, CE Certified.
Supplying, installation, testing & commissioning of 4MP 30 fps HD indoor / outdoor IR IP bullet camera with 1/3‑inch CMOS, Sensor pixels 2612 (H) x 1980(V), Sensitivity-0.24 lx (color) 0.04 lx (mono) ,IR range 30 mtrs, Dynamic range 70 db, True day/night, Automatic Electronic Shutter, Video compression H.264 MP ; M-JPEG, White balance, BLC, Analog video output, Lens (zoom / focus) 3.6 mm lens, Two-way, full duplex Audio, Audio compression AAC, G.711, L16 , ONVIF Profile S, CE Certified.
Supply installation and commission of pann tilt zoom camera with 360 deg pan and 90 deg tilt with 36 X Zoom having maximum resolution of Max. 1920 × 1080 @30fps,true day night camera with 130 m IR range , optional, fine picture at Ultra-low light,supports compression format H.265, H.265+, H.264+, H.264, 3D Digital Noise Reduction support.
SITC of IP network recoder with following feature Processor - Dual-core embedded processor . Two-way Talk - 1 channel Input, 1 channel Output, RCA,Video Output - 1 HDMI, 1 VGA , IP Camera Input - 8/16/32 Channel IP , Compression - H.264+/H.264/MJPEG,Video Resolution - 2560 × 1920, 2048 × 1536, 1920 x 1080, 1280 x 1024, 1280 x 720, 1024 x 768 , Hard Disk - 4 SATA Ports, up to 8TB ,Motion Detection - MD Zones: 396 (22 × 18),Recording Mode - Manual, Schedule (Regular, Continuous), MD (Video detection: Motion Detection, Camera Blank, Video Loss), Alarm, Stop, Backup Mode - USB Device /Network , Interface Ports - 1 HDMI, 1 VGA, 2 USB(1 USB 2.0 , 1 USB 3.0 ), 1 RS485, 1 RS232, 1 RJ45.
Supply, Installation, Testing and commissioning of Managable 24 port Switch with Power on Ethernet (PoE) enabled, 10/100, RJ45 Access ports with PoE complete as required.
Supply, installation, testing and commissioning of of 8 TB HDD all accessories complete as required.
Supply installation and commissioning of 48 inch LED monitor for disply of camera.
SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM
Supplying installation testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including all the required accessories like Solar PV module, Grid Tie invertor, arrey junction box, cabling & wiring, earthing, surge protection device, FRLSame structure for mounting of solar panel. The cell shall be poly crystaline silicon cells of 6 inch each and module efficiency shall be more than 17%. Solar module shall have linear output warranty with degradation not exceeding 0.7% FRLSom 2nd Year onwards. Minimum 80% power output must be assured at end of 25 years. The FRLSont glass of solar module shall be low iron tempered glass ARC type. Termination box shall be Thermo-plastic, IP 67 or better, UV resistant with built-in-bypass. The nominal power of a single PV module shall be minimum 500 Wp or higher. Positive power tolerance modules only to be used. RF identification tag for each solar module shall be provided inside the module and must be able to withstand environmental conditions. The solar panel shall be complience of IEC 61215, IEC 61730 certified by TUV Rheinland / UL. The solar panel shall be installed as per BOQ & detailed technical specification.
AUTOMATIC FIRE DETECTION GAS SUPPRESSION SYSTEM IN PANELS
Supply, fixing, testing and commissioning of Automatic Linear pneumatic Tube Detection based Novec 1230 System for Electrical Panels (consisting of the following components. 6 KG Novec 1230, DLP Assembly with automatic valve mounted on approved cylinder, push in connector for tube, Novec 1230 gas, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.
Linear pneumatic heat Detection Tube with all necessary fittings & supports
Master Control Unit with Audio Visual Alarm with wiring to make complete system operational. The Control Panel should have provision for integration with Fire Alarm/SCADA/BMS System (Supply to be provide by the end client at 220 Volt AC).
DG SET & SUBSTATION WORK
DIESEL GENERATING SET
Supply, Installation testing and Commissioning of Silent type Diesel Generating Set with AMF PANEL at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-2) fabricated out of CRCA sheet of 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following.
Diesel Engine -
Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system.
Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings :
Start stop switch with key
Water temperature indication
Lubrication oil pressure indication.
Lubrication oil temperature indication.
Battery charging indication
RPM indication
Over speed indication
Low Lube oil trip indication
Engine hours indication
Alternator -
Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for bus duct termination / cable termination as required.
Note : - Alternator should have with all other accessories as per specified in Technical specfications.
Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.
Inbuilt Fuel tank of standard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete.
Daily service Fuel tank of 990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required.
Exhaust Silencer - Exhaust manifold with residential silencer.
The D G set should be supplied with required hardware for external PLC based auto synchronization, auto load sharing, auto load management system.
Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH.
Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.
Supply, Fixing, testing and Commissioning of Exhaust gas piping system of Class `B' MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with mineral wool / rock wool insulation of minimum 75 mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil. The measurement shall be done on the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will go well above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will be confirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval) 200 mm dia (wall thickness - 4.8 mm)
Supply & fixing of SS Bellow of following diameter 200 mm dia
Supply & fabrication of D G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MS angle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation.
11 KV HT VCB BREAKER PANEL BOARD (INDOOR TYPE) Supplying, Installation, Testing & Commissioning of indoor type floor mounted metal clad, 11 KV VCB panel with 3 nos VCBs, totally inclosed & fully interlocked, horizontal drawout, horizontal isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and manually closing breaker suitable for use on 11 KV, 3 phase, 50 Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 630 Amp capacity, breaker featured with mechanical ON/OFF indicator with hand trip device.
Spring release coil, shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with following switchgears and accessories i/c connections for 3C x 300 sq.mm. XLPE 11 KV cable (cable entry from bottom), end termination with heat shrinkable jointing material etc. as required. (Note - Cost of end termination not included in this item).
a) 1 No, 630 Amp, VCB.
d) 1 No - Microprocessor based numericak relay with O/C, E/F and S/C protection.
e) 1 No - set of dual core dual ratio 3 CTs 100/5A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection.
f) 1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
g) 1 No. hooter with hooter acceptance and reset push button.
h) 1 No - Red, Yellow & Blue for phase indication.
i) 1 No - Amber for Trip indication.
j) 1 No - Red `ON' Green `OFF'indication.
k) 1 No - Spring charge indication.
l) 1 No - Auto trip indication.
m) 1 No. hooter with hooter acceptance and reset push button.
n) 1 No. master trip relay. ( Electromechanical Type )
o) 1 No.Trip ckt supervision relay. (Electromechanical Type )
a) Outgoing - 2 No, 630 Amp, VCB.
c) 2 No - Microprocessor based numericak relay with O/C, E/F and S/C protection.
d) 2 No - set of dual core dual ratio 3 CTs 100/5 A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection.
e) 1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
f) 2 No. hooter with hooter acceptance and reset push button.
g) 2 No - Red, Yellow & Blue for phase indication.
h) 2 No - Amber for Trip indication.
i) 2 No - Red `ON' Green `OFF'indication.
j) 2 No - Spring charge indication.
k) 2 No - Auto trip indication.
l) 2 No. hooter with hooter acceptance and reset push button.
m) 2 No. master trip relay. ( Electromechanical Type )
n) 2 No.Trip ckt supervision relay. (Electromechanical Type )
o) 2 No.auxiliary relay for transformer fault.
p) Power pack.
H.T. Panel described as above
TRANSFORMER Design, manufacture, supply, installation, testing and commissioning of out door type copper wound transformer continuously rated for 3Ph 50 Hz at full load rating the transformer should have oil immersed winding having vector group DY-11, HT side connected in star with neutral brought out connected to provide separate earthing. The transformer shall have power terminal arrangement bushing / cable end box on HT side and cable end box on LT side. 1000 KVA, 11 KV /0.415 KV, 3 phase, 5.0 % impedance, 50 Nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the Transformer. The transformer should have following standard as per amended IS specification and the load * no load losses shall be limited to the values given below or as per IS 2026 and latest IS-1180 or Norms issued by SEB which ever are Lower.
Oil Conservator with filling hole with cap and plain oil level gauge.
Silica gel dehydrating breather charged with silica gel.
Oil drain Valve
Oil Filter Valve
Lifting eyes / Hooks
Two earthing Terminals
Diagram and rating plate
Air Vent
Explosion Vent
100 mm dia thermo meter with thermometer pocket
Four bi directional plain roller
Buchholz relay
Resistance Temp detector
Marshalling box
Automatic Voltage Regulator ( AVR)
Remote Tap Changing controller ( RTCC)
Transformer 11000/415 volts with on load Tap changer -15% to +5% in steps of 1.25% with RTCC, AVR and marshalling box and other specification as per BIS Level-2
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3C x 240 Sqmm, 11KV XLPE
Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required. 3C x 240 Sqmm, 11 KV XLPE
Laying of one number additional PILCA / PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV of size exceeding 120 sqmm but not exceeding 400 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning protective covering and refilling the trench etc. as required.
Supply & Laying of following sizes of 1.1KV grade Copper conductor XLPE insulated and FRLS PVC sheathed armoured control cable including termination conforming to relevant IS.
4 core, 2.5 sq.mm.
10 core, 2.5 sq.mm.
12 core, 2.5 sq.mm.
Supply & Fixing of Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006.
Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.
Supplying & Placing of First aid box as approved by St.John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963 etc as reqd.
Supplying & Installation of Shock treatment chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English) etc. as reqd
S.I.T.C of Following rating LED Street Lighting luminare with pressure die cast housing and toughened glass cover (IP 66 protection ) in existing pole / pipe for supply voltage 100-270 AC 50Hz Luminare shall be confirm to IS :10322 part 5/ section-3 and shall be complete with all nessessary accessories as required. 60W LED Street Light
S.I.T.C of Following rating LED Post Top lamp made in die cast aluminium housing with decorative clear / opel acrylic diffuser on existing pipe including connection with 1.5sq.mm coppwr conductor etc all complete as required. 20/25W LED Post top lamp clear
S.I.T.C of Following rating approved make LED Bpllard Fitting with cylindrical shape and inverted cone shape head of height 600 to 850 mm power input -8/9 watt with die cast aluminium housing opel with PC diffuser, IP-65/54 protection, conferming to IS : 10322 part 5 etc all complete as requird. (Excluding Plinth Charge.)
Supplying & installation of 7 mtr. Height Octagonal Hot Dip galvanized pole (BOP. 7030) with top dia 70 mm bottom dia 130 mm & made of 3 mm thick sheet base plate dimensions 200x200x12 mm (LxBxT) including suitable size of foundation bolt all complete as required (without Arm).
1m Single Arm Suitable for 70MM Top
HORTICULTURE WORK
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment)
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment)
Screened through sieve of IS designation 20 mm
Screened through sieve of IS designation 16 mm
Screened through sieve of IS designation 4.75 mm
Supplying and stacking of well decayed cattle manure at site including royalty and carriage up to 5.0 km (cattle manure measured in stacks will reduced by 8% for Payment)
PREPARATION Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure)
Rough dressing the trenched ground including breaking clods
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation
Fine dressing of the ground
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Engineer-in-charge (cost of sludge, dump manure and / or good earth to be paid separately).
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50.0 m, lift up to 1.50 m complete (cost of sludge, manure or extra earth to be paid for separately)
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)
Holes 1.2 m diameter and 1.2 m deep
Holes 90 cm diameter and 90 cm deep
Holes 60 cm diameter and 60 cm deep
MAINTENANCE Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (the good earth shall be paid for separately)
TREES Delonix regia,Jacranda mimosifolia,Cassia fistula,Azadiractha indica,Alstonia scholaris,Callistimon lanceolatus,Plumeria alba,Bahunia purpurea,Cassia roxburghii,Butea monosperma
SHRUBS Clerodendrome inerme,Tecoma gaudichaudi,Cestrum noctumum,Bouganvillia mahara,Hibiscus rosa sinensis,Ixora,Aclypha wilkensiana singaporensis,Nerium oleander,TMC,Plumbago auriculata,Tecoma stans,Golden duranta
GROUND COVERS Wedelia trilobata,Setcreasea purpurea,Syngonium butterfly,Jasminum sambac,Hymenocallis littoralis
PEB WORK (PRE-ENGINEERED BUILDING STRUCTURE WORK)
Providing and erecting per engineering steel building, system with primary members, secondary members connections, roof sheeting, sheeting fastener, sealer closures, ridge cover flashing and trim, gutters and downspouts, anchor bolt and templates all fabricated primary and secondary member shall have continuous submerged are welding (SAW) as per IS Code for technical specification and as per architecture drawings enclosed. 1- Primary Member,2- Secondary Member,3- Sheeting,4- Hardware and accessories,5- Cold- Formed ( Purling guder)
COLD STORAGE SYSTEM
FROZEN CHAMBER (Room Temp : -20°C to -24°C)
Design, Supply & Installation of Water Cooled Condensing Units with SEMI HERMETIC SCREW or 2 STAGE RECIPROCATING RACK COMPRESSOR (refrigeration capacity : VTS; SST: -28°C, SDT : +40°C) Make: TRUFROST, BITZER, FRASCOLD INDIA or equivalent
Design, Supply & Installation of Evaporators Unit (3 Working +1 Standby) as per cold room URS & finalised drawings. The Unit will include necessary MS angle support duly painted for hanging units along with support tie rods , nuts and bolts etc. (refrigeration capacity : VTS; SST: -28°C, SDT : +40°C) Make: TRUFROST, LUVE, Guntner, KARYER or equivalent
ANTI ROOM & DOCK AREA (Room Temp : +8°C to +12°C)
Design, Supply & Installation of Evaporators Unit (6 Working +0 Standby) as per cold room URS & finalised drawings. The Unit will include necessary MS angle support duly painted for hanging units along with support tie rods , nuts and bolts etc. (refrigeration capacity : VTS; SST: -4°C, SDT : +40°C) Make: TRUFROST, LUVE, Guntner, KARYER or equivalent
CHILLER CHAMBER (Room Temp : +2°C to +6°C)
Design, Supply & Installation of Evaporators Unit (3 Working +1 Standby) as per cold room URS & finalised drawings. The Unit will include necessary MS angle support duly painted for hanging units along with support tie rods , nuts and bolts etc. (refrigeration capacity : VTS; SST: -4°C, SDT : +40°C) Make: TRUFROST, LUVE, Guntner, KARYER or equivalent
Design, Supply & Installation of Water Cooled Condensing Units with SEMI HERMETIC RECIPROCATING RACK COMPRESSOR (refrigeration capacity : VTS; SST: -4°C, SDT : +40°C) Make: TRUFROST, BITZER, FRASCOLD INDIA or equivalent
Electronic Expansion Valve Set (Incl. EXV Controller, Pressure Tranducer, Tempreture Sensor, Coil etc) make: Danfoss, Carel, Sanuha or equivalent
ASTM A333 Low Temperature Seamless Pipe & Copper refrigerant pipes (including liquid and suction line, bends, elbow, Socket, nitrile insulation, MS & GI stud channel support for laying).
Supply & installation of CPVC/UPVC/PVC condensate drain pipe with necessary fittings, supports & accessories from the Evaporator coil to the Nearest Drain point at Ground floor Level.
Electrical Power and Control Cables with Conduit Pipe (including bends, sockets, clamps etc); Cable trays etc
Refrigerant R404A & R134A
Refigeration Control Panel for refrigeration unit & Temperature Controller
Cooling tower
Cooling tower water pump, Water Piping , Pipe fittings, valves pressure guages, pressure controllers, pipeline supports.
Submission of O&M manuals, Test certificates, all the validation documents(Technical data sheet, P&ID Drawings, Electrical power & control layout)
PUF Sandwich Wall & Ceiling Panels Thk. 150mm, 0.40mm TCT, 240 Mpa, 180GSM Colour coated PPGI,Off white color sheet on both sides with PUF density 40± 2 Kg/ cu.m. make : TRUFROST, LLOYDS, Kingspan Jindal or equivalent
PUF Sandwich Wall & Ceiling Panels Thk. 100mm, 0.40mm TCT, 240 Mpa, 180GSM Colour coated PPGI,Off white color sheet on both sides with PUF density 40± 2 Kg/ cu.m. make : TRUFROST, LLOYDS, Kingspan Jindal or equivalent
PUF Sandwich Wall & Ceiling Panels Thk. 80mm, 0.40mm TCT, 240 Mpa, 180GSM Colour coated PPGI,Off white color sheet on both sides with PUF density 40± 2 Kg/ cu.m. Flashings (Internal) ,Flashings (External),Panel Ancillaries (Silicon sealants, SD ST Screws, Butyle tapes,Puf Chemicals/Liquid foaming, Allu. Rivets, Cotch screws, Raval plugs etc.) for Wall & Ceiling Panels .GI "L" 50x40x1.2mm thick along with Hardware & Accessories etc., (for Floor to Wall ). Ceiling Panel Supporting System - with GI Plate along with hardware and complete Accessories etc..(for 150mm thick Panels) make : TRUFROST, LLOYDS, Kingspan Jindal or equivalent
Floor Insulation PUF slab with Ancillaries (Primer,Bitumen,Tarfelt as vapour barrier)
PUF INSULATED AUTOMATIC SLIDING DOOR 80MM- FOR COLD ROOM (Manual Sliding Door of Size 2400mmx4000mm; Temperature Range upto -25 degC) Make : Metaflex, MTH, Infraca, Gandhi Automation or equivalent
PUF INSULATED AUTOMATIC SLIDING DOOR 150MM- FOR COLD ROOM (Sliding Door of Size 2400mmx2100mm; Temperature Range upto 0 degC) Make : Metaflex, MTH, Infraca, Gandhi Automation or equivalent
PUF INSULATED HINGED DOOR 80MM- FOR EMERGENCY EXIT (Hinged Door of Size 1000mmx 2100mm; Temperature Range upto 0 degC) Make : TRUFROST, Metaflex, MTH.
DOCK LEVELLER (Dock Leveler /Loading Ramp of size 2000mmX2500mm with single lip of length 400mm alongwith complete accessories) Make : Shakti Hormann, Infraca, MTH, Gandhi Automation or equivalent
DOCK SHELTER (Retractable Dock Shelter of size 3400 x3500 with Side Flaps of 700mm and top flap of 1000mm) Make : Shakti Hormann, Infraca, MTH, Gandhi Automation or equivalent
MANUAL OVERHEAD SECTIONAL DOOR (Automatic Overhead Sectional Door of Size 2500x3200) Make : Shakti Hormann, Infraca, MTH, Gandhi Automation or equivalent
HEAVY DUTY DUBLE DEEP PALLET RACKING SYSTEM ; Load Capacity - 2160 Kgs UDL / Level
Supply & Erection of the Steel Structure for Building (Including Painting), Roof & Wall Sheeting, Accessories, Hardware, Down take pipe, Gutter & Screws,Mezzanine Including Metal Deck Sheet and Freight,Steel Staircase, PUF Panel Support Structure on Side Wall & End Wall. all fabricated primary and secondary member shall have continuous submerged are welding (SAW) as per IS Code for technical specification and as per architecture drawings enclosed.
ELECTRONIC MODULAR U – BEAM PITLESS TYPE WEIGH BRIDGE:
Fully Electronic 100T – 16 x 3mtr – U – Beam Pit less Type Weighbridge (Capacity – 100T, Accuracy – 10Kg), 6nos. of separate structure, 8nos. of Multiended Shear Digital Load cell, Digital Indicator (D2008), Printer, Printer cable, Jumbo Display, Junction Box, 15 pin Connector for Load cell, UPS without Battery, Weighbridge Software.
Unmanned System: Boom Barrier (2 Nos.),UHF Readers (2 Nos.) ,UHF Cards (50 Nos.) ,Photo Sensor (Self Reflector Sensor) with Pole for Vehicle positioning. (3 Nos.) ,Traffic Light (Two color) with Pole (2 Nos.), Hooter (1 No.) Hik vision IP Camera (2 Nos.), Control Panel with PLC (1 No.) ,Network Switch (4 pole) (1 No.), 4 core Cable(30mtr.) ,CAT 6 network cable (100 mtr.) ,add power cable 100mtr,add 6core cable 100mtr.add 24core cable 15mtr,Weighmast Software for Unmanned (1 Pc),Junction box (1 No.)
ANPR Camera (2 Nos.)
4 Channel NVR for Video Recording
POE Switch (1 Pcs)
Labour Cess @ 1%
HEIGHTEN CONSTRUCTIONS
SHREE RAM-TRIBENI JV
M/S SINGHAL ENTERPRISES
RAJBIR CONSTRUCTION PVT. LTD.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_88964.xls
BOQ • 0.86 MB
SBD_DHANBAD.pdf
Tender Documents • 5.30 MB
Download all tender documents and submit your bid