| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.9 CrAccepted-AOC 402 MADHAVA PLOT NO C 4 E BLOCK BANDRA KURLA COMPLEX BANDRA EAST MUMBAI MAHARASHTRA 400051 | MUMBAI SUBURBAN | MAHARASHTRA | 400051 | ₹5.9 Cr | 1 | Accepted-AOC L1 rate with taxes |
| 2 | 2₹13.9 Cr+₹8.0 Cr (135.1%)Rejected-AOC FUGRO HOUSE D 222 30 T T C INDUSTRIAL AREA MIDC NERUL NAVI MUMBAI THANE MAHARASHTRA 400706 | THANE | MAHARASHTRA | 400706 | ₹13.9 Cr+₹8.0 Cr (135.1%) | 2 | Rejected-AOC Order placed with L1 |
Tender Value
Refer Docs
EMD Value
₹15 L
Closing Date
14 Sept 2020, 3:30 pmClosed
Division Head Finance and Administration
NIWE, Chennai
Offshore Geotechnical Investigation at proposed LiDAR locations at Zone A1 and Zone C2 and provision for the additional bore hole at Zone C1 subject to clearance protocal/budget availability in Gulf of Mannar, Off Tamilnadu Coast
2020_NIWE_578213_1
NIWE/PUR/17/120/20
Open Tender
Marine Services
Works
45 days
National Institute of Wind Energy
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹15 L
Yes
8 Dec 2020
19 Aug 2020
15 Sept 2020
19 Aug 2020
14 Sept 2020
19 Aug 2020
Amount
Mobilization and Demobilization of equipment/ personnel to site*
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 0-2m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 2-4 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 4-6 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 6-8 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 8-10 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 10-12 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 12-14 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 14-16 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 16-18 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 18-20 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 20-22 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 22-24 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 24-26 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 26-28 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 28-30 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 30-32 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 32-34 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 34-36 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 36-38 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 38-40 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 40-42 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 42-44 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 44-46 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 46-48 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 48-50 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 50-52 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 52-54 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 54-56 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 56-58 m depth
Carry out bore holes through for all types of overburden soil strata using 150 mm dia. 58-60 m depth
Carry out bore holes through for all types of rock strata 0-2 m depth
Carry out bore holes through for all types of rock strata 2-4m depth
Carry out bore holes through for all types of rock strata 4-6m depth
Carry out bore holes through for all types of rock strata 6-8m depth
Carry out bore holes through for all types of rock strata 8-10m depth
Carry out CPT through for all types of overburden soil strata 0-2m depth
Carry out CPT through for all types of overburden soil strata 2-4m depth
Carry out CPT through for all types of overburden soil strata 4-6m depth
Carry out CPT through for all types of overburden soil strata 6-8m depth
Carry out CPT through for all types of overburden soil strata 8-10m depth
Carry out CPT through for all types of overburden soil strata 10-12m depth
Carry out CPT through for all types of overburden soil strata 12-14m depth
Carry out CPT through for all types of overburden soil strata 14-16m depth
Carry out CPT through for all types of overburden soil strata 16-18m depth
Carry out CPT through for all types of overburden soil strata 18-20m depth
Carry out CPT through for all types of overburden soil strata 20-22m depth
Carry out CPT through for all types of overburden soil strata 22-24m depth
Carry out CPT through for all types of overburden soil strata 24-26m depth
Carry out CPT through for all types of overburden soil strata 26-28m depth
Carry out CPT through for all types of overburden soil strata 28-30m depth
Carry out CPT through for all types of overburden soil strata 30-32m depth
Carry out CPT through for all types of overburden soil strata 32-34m depth
Carry out CPT through for all types of overburden soil strata 34-36m depth
Carry out CPT through for all types of overburden soil strata 36-38m depth
Carry out CPT through for all types of overburden soil strata 38-40m depth
Carry out CPT through for all types of overburden soil strata 40-42m depth
Carry out CPT through for all types of overburden soil strata 42-44m depth
Carry out CPT through for all types of overburden soil strata 44-46m depth
Carry out CPT through for all types of overburden soil strata 46-48m depth
Carry out CPT through for all types of overburden soil strata 48-50m depth
Carry out CPT through for all types of overburden soil strata 50-52m depth
Carry out CPT through for all types of overburden soil strata 52-54m depth
Carry out CPT through for all types of overburden soil strata 54-56m depth
Carry out CPT through for all types of overburden soil strata 56-58m depth
Carry out CPT through for all types of overburden soil strata 58-60m depth
Conduct all the Field and laboratory tests (All tests as per IS) as specified in tender on overburden soil samples collected at an interval of every 1.5 m
Conduct all the Field and laboratory tests (All test as per IS) as specified in tender on rock samples collected at an interval of every 1.5 m
Preparation and submission of detailed report with necessary graphs and drawings with recommendations (Both Hard and Soft copy)
Fugro Survey(India) Pvt. Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .