EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Const of appurtenants works allied works at Fatehpora Phase 1st Baramulla B.W.O SITC of internal Electrification , with Protective and Controlling Devices,Main Control Panel,Cabling,wiring ,with Fire Extinguishers,Earthing ,Lighting fixtur
2025_PWDJK_295074_3
NIT No.190/2025-26 Dt/13/11/2025
Open Tender
Electrical Works
Percentage
Fathepora Baramulla
Please refer Tender documents.
4 documents required · 4 mandatory
₹300
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹3,198
26 Nov 2025
13 Nov 2025
27 Nov 2025
13 Nov 2025
26 Nov 2025
13 Nov 2025
Wiring for Light point/Exhaust fan point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable in surface/recessed Conduits.The job including cost of Circuit Wire (6/8 points per circuit) in 2.5 sq.mm (with 1x2.5 sq.mm) for earth Multi strand Copper wire from Switch board to D.B complete (Havells/Polycab/Anchor/ eq. make to be approved by EIC),including cost of Conduits with other accessories like bends,Deep Junction Boxes,Surface Junctions etc to be laid in wall/ceiling(Slab) complete, with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front,Modular blanking plate where required & suitable GI box etc ISO/IEC Certified Havells/ Legrand/Panasonic/Anchor Rooma Plus/Schneide/ABB/ eq. Make & shall be approved before execution of work.
Wiring for Ceiling fan point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable in surface/recessed Conduits(Havells/Polycab/Anchor eq. make to be approved by EIC) including cost of Conduits with other accessories like bends,Fan Junction Boxes to be laid in ceiling etc complete with 01 No. of 6 Amp Modular Switch,Two Module Stepped Type Electronic Fan Regulator, Modular Plate,Cover in front and suitable GI box etc ISO/IEC Certified Havells/ Legrand/Panasonic/Anchor Rooma Plus/Schneider/ABB/ eq. Make & shall be approved before execution of work.
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor eq. make to be approved by EIC) including cost of Conduits with other accessories like bends,etc complete to be laid in wall and finishing the surface to its original shape by cement mortar plastering, with 01 No. of 16Amp,Modular switch, Modular 01 No. of 3-PIN 16Amp Socket, Modular plate, cover in front,Modular blanking plate where required and suitable GI box etc ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor Rooma Plus/Schneider /ABB/ eq. Make & shall be approved before execution of work.
Wiring for 6Amp Plug (Computer) with (P+N+E) 3 x 2.5 sq.mm FRLS PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab /Anchor/ eq. make to be approved by EIC),including cost of Conduits other accessories like bends etc complete to be laid in wall and finishing the surface to its original shape by cement mortar plastering,with 02 No. of 6 Amp Modular Switch, 02 No.of Modular 6 Amp.of 5-PIN Socket,Modular Plate,Cover, Modular blanking plate where required and suitable GI box etc ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor Rooma Plus/Schneider /ABB/ eq. Make & shall be approved before execution of work.
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/Anchor/Finolex/ eq. make to be approved by EIC) including cost of Conduits with other accessories like bends etc complete to be laid in wall/ceiling(Slab) & shall be approved before execution of work.
2x10 sq.mm+ 1x10 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards.
2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter Sub main From Main Panel to Distribution Boards.
2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) forInverter Circuits.
Supply/Fixing/Testing and Commissioning of SP 6Amp to 32Amp Rating ,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load in existing MCB . DB Complete with connections.(Havells/L&T/Siemens/Legrand/ABB /Schneider / eq. make to be approved by EIC)
Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (Havells/L&T/Siemens/Legrand/ABB/Schneider / eq. make to be approved by EIC)
Supplying and Fixing of MCB 8-Way horizontal typed , sheet steel, Double Door Distribution Board, SPN 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (Havells/L&T/Siemens/Legrand/ABB /Schneider / eq. make to be approved by EIC)
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
Supply/Installation/Testing and Commissioning of 18 W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havells/Wipro/Jaquar / eq. make to be approved by EIC.
Supply/Installation/Testing and Commissioning of 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/LUKER USA/Anchor / eq. make to be approved by EIC.(1-Star)
Supply/Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified.
Supply/Laying/Connecting and Commissioning of 25 sq.mm 2-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/RR / eq. make to be approved by EIC with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories forProtection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench.
Providing & Fixing of IK08 IP-66 protected high power 50 Watt LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. ( Phillips/Wipro/Havells/Jaquar/ eq. make to be approved by EIC
Supply/Installation/Testing/Commissioning of NXG 1150/12V Pure Sinewave Solar Inverter With ISOT Technology, Intelligent Load Sharing(with 2-Year Warranty), 01 No. of 200Ah,12V Tubular battery (with 05 Years Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc Havells/Luminious/EXIDE/AMRON / eq. make to be approved by EIC
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.92 MB
BOQ_954847.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .