Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.8 L+₹1.6 L (19.3%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹8.4 L
EMD Value
₹12,700
Closing Date
10 Feb 2022, 5:00 pmClosed
Executive Engineer (Electrical)
Executive Engineer (Electrical) Office of the Executive Engineer Electrical Electrical Division Engg Department University of Calicut Calicut University P O Malappuram District Kerala 673635
Rewiring of H type Quarters in the University Campus
2022_UoC_472242_1
D3/E-Tender No.21/2021-22
Open Tender
Electrical Works
Item Rate
60 days
University of Calicut
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,995
₹12,700
28 Mar 2022
3 Feb 2022
15 Feb 2022
3 Feb 2022
10 Feb 2022
3 Feb 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A. (1.10.1)
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (1.11)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2x1.5 sq.mm + 1 x 1.5 sq. mm earth wire. (1.14.1)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (1.14.2)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. (1.14.3)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire. (1.14.7)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm. (1.17.3)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required - 3 x 2.5 sq. mm. (1.17.12)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm. (1.21.1)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (1.25)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(1.26)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings. (1.31)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (1.32)
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. (1.33)
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.. (1.38)
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). (1.56)
Supplying and fixing PVC batten/ angle holder including connection etc. as required. (1.58)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator - 8 way, Double door. (2.3.2)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole. (2.10.1)
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. (2.11)
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps. (2.12.1)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps. (2.14.2)
Dismantling the existing service connection from the LT post with out causing any damages and installation of new/existing WP wire including supporting wire. Dismantled materials shall be returned to the Electrical store with out causing any damages. (od211462/ 2019_ 2020)
Supplying 4 Sq.mm PVC insulated and sheathed 2 core weather proof aluminium cable. (od211463/2019_2020)
Dismantling the damaged wiring installations and its accessories and the dismantled materials should be returned to the Electrical store. (od211464/2019_2020)
Dismantling the 1400/1200 mm AC ceiling fan overhauling greasing and refixing the same on the existing fan hook after repainting with 2 coat of enameled paint over the primer and giving connection etc.. Complete. (od211465/ 2019_2020)
Dismantling the old Energy meter with supplying and installing of M.S Box meter board (Glass window type), kit kat Fuse (32A), DP isolator (40A), & Neutral link and refixing of dismantled energy meter, Including connection etc Complete. (od211466/ 2019_2020)
Supplying Nylon rope for supporting WP service wire. (od211467/2019_2020)
Wiring plug point along with wiring of light point including supply fixing 5A flush type modular switch and 3pin plug socket in combined position.(Combined plug). (od211468/ 2019_2020)
Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture. (90.3.20.3)
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. (Dimension of pit shall be minimum of 2.5m * 0.6m * 0.6m). (od211486/2019_2020)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4sq.mm. (1.17.21)
Providing and fixing 10 SWG copper wire on surface or in recess for loop earthing as required. (od214426/ 2019_ 2020)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2 way 5/6 amps switch. (1.24.2)
ASIF ELECTRICAL WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_677241.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .