| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 CrAccepted-AOC B 16 SHREEJI NAGAR DURGAPURA JAIPUR RAJASTHAN 302018 | JAIPUR | RAJASTHAN | 302018 | ₹6.1 Cr Quoted ₹6.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹8.1 Cr+₹1.7 Cr (26.7%)Rejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹8.1 Cr+₹1.7 Cr (26.7%) | L2 | Rejected-Finance Lowest L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
| 4 | Rejected-Technical 3RD FLOOR 840 1A CHIRAG DELHI NEW DELHI 110017 CHIRAG DELHI 3RD FLOOR 840 1A CHIRAG DELHI NEW DELHI 110017 SOUTH DELHI SOUTH DELHI DELHI 110017 | SOUTH DELHI | DELHI | 110017 | - | - | Rejected-Technical Disqualified |
Tender Value
₹5 Cr
EMD Value
₹5 L
Closing Date
22 Feb 2021, 3:00 pmClosed
Chairman cum Managing Director, RISL
RISL, First Floor, C-Block, YojanaBhawan, Tilak Marg, C-Scheme, Jaipur-302005 (Rajasthan)
RFP Document for Overall Maintenances and Operation of Non-IT Equipments installed at Datacenter RSDC P-1, P-2 and P-3, Jaipur
2021_RISL_210166_1
F4.2(526)/RISL/TECH/2020/13076 Dated- 07 -01-2021
Open Tender
Miscellaneous Services
Item Rate
1095 days
Jaipur
As Per RFP
4 documents required · 4 mandatory
₹5,000
Managing Director RISL
₹5 L
Yes
Jaipur
25 Apr 2022
9 Jan 2021
22 Feb 2021
9 Jan 2021
22 Feb 2021
16 Feb 2021
12 Jan 2021
Amount
DIESEL GENERATOR (Make: Kirloskar-KOEL) 400KVA DG set with acoustic enclosure with accessories inclusive of 4 Numbers of 12 V,180 AH lead acid batteries along with leads, day fuel tank, fuel piping from fuel tank to Engine, fuel tank to fuel storage tank, Residential silencer, Engine cold start kit, suitable size termination box (Cable / Bus duct) with extended Alternator terminal with bus bars including control switchgear & Exhaust System etc as installed at site.
UPS SYSTEM (Make: Delta) 400 KVA double conversions online IGBT based UPS with active/ Passive filter as installed at site with isolation transformer as installed at site
Battery Bank (Exide Powersafe Plus) 12V VRLA 200AH (Min) battery bank with Battery Breaker suitable for the above UPS and Battery bank with Copper cable of adequate rating from UPS to battery as installed at site. (Each Bank includes 38 batteries of the mentioned model)
UPS SYSTEM (for other load) (Make: Emerson) 2 x 20 KVA Parallel redundant double conversion IGBT based with active! Passive filter as installed at site with isolation transformer as installed at site
Battery Bank (Rocket) 12V SMF mono block 100AH ( Min) battery bank with Battery Breaker as installed at site. (Each Bank includes 34 batteries of the mentioned model)
MAIN LT Panel: MAIN LT Panel including of followings as installed at site but not limited to : A. INCOMER :- 2 Nos 1250 Amps and 2 nos of 1000Amps EDO TYPE ACB 50 kA, 4 pole, microprocessor release, and Motor wound spring charged closing mechanism. Each Incomer shall have one set of the following items: B. BUS COUPLER :- ACB, 1000 Amps, 50 kA, microprocessor release, Motor wound spring charged closing mechanism, EDO type, -01 No Indication Lamps, LED type, for breaker 'ON’, ’OFF’,’TRIP’ indication with SP MCB control fuses- 3 sets Suitable arrangement, interconnection required for electrical and mechanical interlock among 2 Nos. Incomers and 1 No Bus coupler - 01 Set Outgoing Feeders: -:-MCB, 630 Amps, 4 Pole, 36kA, microprocessor release -3 Nos. MCCB, 400 Amps, 4Pole, 36 kA, microprocessor release -3 Nos. MCCB, 160 Amps, 4 Pole, 25 kA -1 Nos. MCCB, 100 Amps, 4Pole, 25 kA -3 Nos. 40 Amps, 4 Pole, 25 kA -1 Nos. Indicating lamps LED type, for breaker “ON“,“OFF“,“TRIP“ indicate on with SP MCB control fuses 14 Sets.( only for ACBs ) As installed at site
APFC panel 300 kVAR automatic, manual Power Factor Correction Panel including followings & as installed at site: Capacitors Type - MD -XL,500V, 3 ph, 50 Hz
PAC Panel 2 nos of PAC Panel, including the followings & as installed at site: A. INCOMER: 1 Nos 400 Amps microprocessor based MCCB 36 kA 4 pole B. Outgoing: 6 nos 100 Amps microprocessor MCCB 25 kA 4 pole Outgoing Feeders:- 3 Nos CTs, 15 VA, class 1.0 and control circuit wiring with SP MCB control fuses.
Lighting DB for item no 11, 12, 13, 14, 15, 16, 17 details given below as installed at site
Double door Distribution Boards including surge arrester for each phase (For Light DBs only): - 12 way TPN
Incomer - 63 Amps TPN -1 nos
Outgoing - 36 nos SP MCB
Double door Distribution Boards including surge arrester for each phase (For Light DBs only): - 12 way TPN Outgoing - 35 nos SP MCB
Incomer - 63 Amps TPN -1 nos
Outgoing - 36 nos SP MCB
Distribution Boards including surge arrester for each phase (For Light DBs only):- 12 way TPN Incomer - 63 Amps TPN - Outgoing - 36 nos SP MCB
UPS OUTPUT PANEL/PDU( for Rack Loads ) as installed at site UPS output Panel, including following: Incomer: 400 Amps 36 kA 4pole microprocessor based MCCB 1 no. Outgoing:16 Amps SP MCB – 4 no.32 Amps SP MCB – 32 No. 32 Amp TP MCB – 10 no, 63 Amp TP MCB – 3 no.
CABLING Upkeep and maintenance of 1100 volt grade, PVC insulated and armored, copper or aluminum conductor cables of the following sizes as installed at site: for item no 20, 21, 22, 23, 24, 25, 26, 27
4 core x 4 sq. Mm. Cu armoured Cable
4 core x 6 sq.mm. Cu. armoured
4 core x 16 sq.mm. Cu. armoured
4 core x 25 sq.mm. Cu. armoured
1 core x 300 sq.mm. Cu. armoured cables
3.5 core x 400 sq.mm. Al. armoured cables
3.5 core x 150 sq.mm. Al. armored cables
3.5 core x 120 sq.mm. Al. armored cables
EARTHING
Upkeep and maintenance of 3.0 meter long gel type earthling with copper electrode as installed at site.
Upkeep and Maintenance of 600 X 600 X 3 mm copper Plate Type Earthing as installed at site.
LIGHTING & POWER WIRING Upkeep and Maintenance of standard wiring electrical points including Wires, sockets/switches (6 Amps,16 Amps & 32 Amps) etc as installed at site:
LIGHTING FIXTURES (make: Philips) Upkeep and Maintenance of the following fixtures wired with high Frequency ballasts, lamp holders and complete with lamps / LED fixtures as installed at site:
1 x 28 watts slimlite Fixtures with electronic ballast/ LED fixtures
2 xPL -L 36 watts decorative panel / LED lights white direct luminaries for modular ceiling.
4x18 watts decorative recessed mounting luminaries.
2 x PL - C 18 watts recessed mounting Down light luminaries with recessed glass Raindrops
2 x PL - C 18 watts recessed ceiling mounting light luminaries with recessed glass Raindrops
2 xPL -L 36 watts decorative panellights white direct luminaries for modular ceiling.
1 x 28 watts recessed mounting Down light luminaries with recessed glass Raindrops.
2 x 36 watts decorative panel Down lights white direct luminaries.
35 wattsP/F recessed type 2'x2' sized standard quality LED lighting fixtures
Maintenance of PAC auto changeover switches per the specs
Maintenance of Automatic fuel level monitoring with flow meter
Air Conditioning System
PRECISION PACKAGED UNITS (Make: Emerson) as installed at site with Indoor and Outdoor units 20 TR (min) sensible capacity Precision air - conditioning unit for Datacenter as installed at site.
Air grills with volume control damper
Return Air Motorized Damper
Comfort Cooling System (Make: Blue Star) a) Air cool duct able type AC units comprising ofb1 X indoor unit, 8.46 TR nominal capacity complete as installed at site.
Air Cooled Cassette Type AC Units (Make: Blue Star) comprising of: 1 x Indoor Unit, 3 TR Nominal Capacity complete & as installed at site.
Access Control System
ACCESS CONTROL UNIT (RTU), (Honeywell)
MAGNETIC LOCK SINGLE 600 LBS,(Bell)
ACCESS READER,(HID)
EXIT PUSH SWITCH
EMERGENCY DOOR REALEASE
TEMA SERVER,(Honeywell)
BIOMETRIC READER, (BioScrypt-4G)
RS 232 TO 485 CONVERTER,(Q Com)
RTU RELAY
MAGNET POWER SUPPLY 24V
MAGNET POWER SUPPLY 12V
DPS SWITCH
MAGNETIC LOCK DOUBLE 600 LBS, (Bell)
U SHAPE BRACKET FOR GLASS DOOR, (Bell)
TEMA SERVER POWER SUPPLY, (Honeywell)
BIO-METRIC WORK STATION, (Secure-Admin)
CCTV SYSTEM
DVR, (Honeywell)
PTZ CAMERA, (Samsung)
FIXED DOME CAMERA,(Honeywell-22, Samsung-1)
HDD ( 1 TB EACH ),(Seagate)
DVR MONITOR, (LG)
CAMERA POWER SUPPLY
DVR REMOTE, (LG)
PTZ CAMERA JOYSTICK (SAMSUNG)
WEB APPLICATION FOR CCTV, (Control Center)
RR SYSTEM
RODIANT PANEL, (Maser)
STAND WITH BRACKET, (Honesty)
RODIANT SATELITE, (Maser)
WLD SYSTEM
WLD PANEL 4 ZONE, (Jay Fire)
WLD HOOTER, (Honeywell)
FIRE ALARM SYSTEM
FIRE ALARM PANEL, (Honeywell)
LOOP POWER MODULE
LOOP CARD DRIVER
485 COMM. CARD
NETWORK MODULE, (Honeywell)
REPETER PANEL, (Honeywell)
PHOTO ELECTRIC SMOKE DETECTOR WITH BASE, (Honeywell)
MANUAL CALL POINT
HOOTER CUM STROBE
CONTROL RELAY MODULE
MONITOR RELAY MODULE
ISOLATER RELAY MODULE
BATTERY, (AMCO-BEST)
RESPONSE INDICATOR, (Honeywell)
PANIC WAR, (DAFIKAS)
VESDA
VESDA 4 ZONE PANEL, (XTRALIS)
POWER SUPPLY
DISPLAY MODULE
P.A SYSTEM
RACK For PA & DVR
CEILING MOUNT SPEAKER, BOSCH
MAIN CONTROLLER, BOSCH
AMPLIFIER 200 W, BOSCH
CALL STATION, BOSCH
FM 200 SYSTEM
FM-200 CYLINDER WITH ASS., KIDDE
GAS RELEASE PANEL, Honeywell
ABORT SWITCH WITH MOUDLE, ADWARDS
MANUAL SWITCH WITH MOUDLE, SUPER FIRE
SERVICE DIS-CONNECT SWITCH WITH MOUDLE, ADWARD
FM 200 NOZZLE , KIDDE
PRESSURE TRANSMETER
POWER SUPPLY
2 Kg NAF PIV Fire Extinguisher, (Safex)
5 Kg ABC Type PIV Fire Extinguisher, (Safex)
CO2 4.5 kg portable Fire Extinguisher, (Safex)
DDC PANEL, (RITTAL)
IPC CONTROLLER, (Honeywell)
EXPIO CONTROLLER(Honeywell)
TEMP CUM RH SENSOR(Honeywell)
485 TO LAN CONVERTOR, (SAN-TELEQUID)
232 TO 485 CONVERTOR, (Q COM)
TANK LEVEL TRANSMITER, (TECHTROL)
EBI SERVER WITH MONITOR, (DELL)
PLC CONVERTOR , (Q COM)
Projector PT-F200NT XGA, (Panasonic)
Description of Work / Item(s)
Amount
Civil Work
FIRED RATED DOOR with lock and heavy duty door closer.
WOODEN DOOR Single and double Leaf for BMS and Storage Rooms, NOC and Call Centre area.
Glass Door with 12 mm toughened glass, floor spring, arrangement for access control, handle, lock etc.
13mm thk nitrile rubber insulation with Alumium Foil use under the false flooring & true ceiling with adhesive and pvc jointing tapes wherever necessary as per standard installation (Server Room Only)
Productivity work chair ( Exclusing Chairs for Call Centre)
Long back executive chair, Visiting chair
Reception Desk with board trays, cpu trollys, three drawer , etc.
Vertical blinds, aluminum perforated, of approved shade to be used for covering the glass wall and windows excluding NOC & Development Center.
Sofa set with 3 + 2 seating arrangement along with Tea table
Wooden Door with Louvers covering Fire suppression Cylinder
Fire Safe ( 300 lt ) Godrej for Media/ backup tapes
Ramp & steps
Fire rated Glass window with powder coated Aluminium Frame for Data Centre Area
H.T. Works:
Cables and Terminations 1(3C x 240 Sq.mm), 11kV cross linked polyethylene (XLPE) insulated aluminium conductor steel armoured cables buried underground.
1(3C x 240 sq.mm), 11kV cross linked polyethylene (XLPE) insulated aluminium conductor cable gland, outdoor type cable sealing kits, insulation tape,
HT METERING CUBICLE (OUTDOOR)
11kV HT Metering Cubicle including all CT's,PTs etc. Suitable for cable entry on both sides.
HT Panel with 1 Incomer and 2 Outgoing of 630A,11kV,20KA HT VCB Breaker (EDO type) With Spare Out going breaker
Battery Charger : Battery charger with one set of 24V DC 100AH station batteries with suitable battery charge inclusive of 6 way SPN DB
3 Phase, 50 Hz, Copper Wound, Oil Immersed, Core Type Transformer of 1000 kVA Rating , ONAN (Oil Natural Air Forced) OLTC with voltage ratio 11/.433 kV, Connection HV/LV: delta/star, . The Transformer should have one side HT cable termination and secondary provision for bus bar for terminating bus duct.
Transformer Output breaker of 1250 Amp breaker panel( out door type)
Spreading of 40 mm metal in outdoor H.T.yard - upto 100 mm - thick layer
Fire buckets with stand filled with fine river sand. 2 buckets with round botton, red painted duly marked as FIRE
LT PANELS
415 Volts, 3Phase 50HZ Panel as per Specification "415V switch boards" as per the specifications and schematic drawing complete as required. DG SYNC CUM AMF panel
415 Volts, 3Phase 50HZ Panel as per Specification "415V switch boards" as per the specifications and schematic drawing complete as required. Datacenter Main panel - 1 and 2 as per RFP Schematic
Supply, loading, unloading, erection, testing & commissioning of 415 Volts, 3Phase 50HZ Panel as per Specification "415V switch boards" as per the specifications and schematic drawing complete as required. 200KVA/ KW Galvonic Isolation Transformer
415 Volts, 3Phase 50HZ Panel as per Specification "415V switch boards" as per the specifications and schematic drawing complete as required. 40 KVA UPS output panel
415 Volts, 3Phase 50HZ Panel as per Specification "415V switch boards" as per the specifications and schematic drawing complete as required. PAC panel
415 Volts, 3Phase 50HZ Panel as per Specification "415V switch boards" as per the specifications and schematic drawing complete as required. CAC Panel -01
415 Volts, 3Phase 50HZ Panel as per Specification "415V switch boards" as per the specifications and schematic drawing complete as required. CAC Panel -02
415 Volts, 3Phase 50HZ Panel as per Specification "415V switch boards" as per the specifications and schematic drawing complete as required. PDU 1A/2A and 1B/2B
415 Volts, 3Phase 50HZ Panel as per Specification "415V switch boards" as per the specifications and schematic drawing complete as required. 380 KVAR APFCR bank
32A, DP, MCB Isolator wall mounted type with suitable enclosure and required accessories for Comfort AC as per RFP Schematic
80Amp Rating Automatic Changeover panel
Bus duct for Transformer-01 & 02 up to the Data Centre LT panel-01 & 02 Respectively. DG Sync Panel to the DC LT panel-01 and 02 1250A Aluminium IP65 Straight Feeder
Bus duct for DG-01, 02 & 03 up to the DC Sync Panel-01 & 02 Respectively 800A Aluminium IP65 Straight Feeder
Track Busways overhead power distribution in data centers and Labs with spring pressure copper conductors in continuous PVC insulation, Extruded aluminum housing, light weight to install with Hitech rods and anchor fastners. Housing will have continuous bottom access to facilitate insertion of outlet box any where along the length. outlet boxes are suitable to reverse to face either cold aisle or hot aisle Busway are for indoor use, finger proof to UL. 100Amp Track Busway,100%N, Busway Section, 3 mtr 200% Note: Proposed busduct shall capable to plun the tapp-off box at any point of busway.
Providing the end terminations with copper lugs for all the above cables with Double compression brass cable glands, taping, crimping, gland and armour earthing, complete electrical system of DC
power wiring circuits (Raw power and UPS Power)
INTERNAL LIGHT FIXTURES
complete DC excluding NOC, CC Area
Motion Sensors for multiple areas for automatic switching the lighs on an off
STEEL ITEMS
Rubber mats, first aid box, shock treatment charts and other sundry items (sizes/capacities to be got approved).
PRECISION AIR CONDITIONING UNITS (SWEGON BLUE BOX)
Air cooled condenser with fan speed controller Inside design condition Server Room - 22 +/- 1 deg. C & Relative humidity : 50% RH +/- 5% a. Nominal Capacity 26 TR - e. BMS Interface for integration with necessary network integration card
Supply air floor grilles with Damper , 600mm x 600mm
CAC/VRV
Outdoor Units: MULTI-VRF units complete with 100% Inverter driven scroll compressor, 22 HP (Cooling-Only), (2x5)
Indoor Comfort AC units:4-Way Cassatte Unit (2TR)
Indoor Comfort AC units: 4-Way Cassatte Unit (2.5TR)
Indoor Comfort AC units: 4-Way Cassatte Unit (3TR)
Indoor Comfort AC units: 4-Way Cassatte Unit (4TR)
Indoor Comfort AC units: MSP Ductable (4.6TR)
Indoor Comfort AC units: Hi-Wall (1TR)
Indoor Comfort AC units: Wireless Remote
Wired Remote
Centralize Remote(Touch Type)
32A, 1 PH, IP Metered PDU (Strip level Monitoring)Rack PDU, Metered, Zero U, 32A, 230V, (20)C13 & (4)C19
32A, 3 PH, IP Metered PDU (Strip level Monitoring)Rack PDU, Metered, Zero U, 32A, 230V, Minimum of 6 No's C13 & 6 No's C19
Cold Aisle Containment System_Row -1 (SR1 to SR72+ 10NR) includes: a. Start & End Roof Element 800x1200 Stable roof elements in a composite metal with a high level of light permeability) b. Center Roof Element 600x1200 (Stable roof elements in a composite metal with a high level of light permeability) C. Door Element 1200W x 2100H (Slimline door element with viewing window, sliding door)
UPS (Delta)
UPS of 200 KW, 3 Phase IN, 3 Phase out, 415 V, Modular hotswappable Design Consisting capable to parrallel up to minimum 400KW of IT load. Quantity of 80 batteries of 12V SMF (ROCKET ESH 12-510W FR) capacity along with each UPS
UPS of 40 KW, 3 Phase IN, 3 Phase out, 415 V, Modular hotswappable, BMS system emergency light and Non_IT Load Quantity of 40 batteries of 12V SMF (ROCKET ESH 12-510W FR) capacity along with each UPS
Battery MS Stand, Inter cell connection, Battery to UPS main Cable for 200/40 kVA UPS
DG Set (Kirloskar-KOEL Green)
500 KVA(+/- 5%) DG set and (Cable /Bus duct) with extended Alternator terminal with bus bars including control switchgear etc.
Exhaust of DG Sets including providing suitable self supporting arrangement
Control Cabling
Copper earthing for DG set
Intelligent Addressable fire alarm control panel with 1 loop card and battery backup of 24 hrs in normal condition and 30 min in alarm condition with necessary accessories
Multisensor Detector with accessories
Response Indicator with accessories
Fault Isolators module with accessories
Addressable Control relay modules. (for GRP, ACS, Hooters, PAS)
Addressable Manual Call Points with accessories
Addressable monitor modules with accessories (monitoring VESDA)
Sounders with strobes with accessories as per technical specification
Ceasefire 4 Kg Fire Extinguisher Clean Agent ,
Public Address System.
6W Ceiling Mount Speaker
Volume Control (for DC Manager Cabins)
Access Control System.
Access Control System TCP/IP enabled 2 Reader Access Door Controller with Power supply and housing
Finger print biometric reader with smart card reader with accessories
Smart Card reader with accessories
Smart Cards
electromagnetic lock with inbuilt magnetic contact & Power Supply with accessories
Emergency break glass unit with accessories
Access Management Software with Time & Attendance Software
PC for Access Control Software
Card Printer with accessories
CCTV Surveillance System.
UL Listed 1/3" CMOS, 800x 600 Resolution, 3~8mm Varifocal lens, minimum of 0.5 lux @ 40 IRE, POE enabled indoor Dome Camera with accessories
UL Listed 1/3" CMOS, 1080x 720 Resolution, 3~8mm Varifocal lens, minimum of 0.5 lux @ 40 IRE, PTZ Camera with accessories
Network Video Recorder with backup of 30 days (Recording: 4 CIF Resolution, 15fps, 30days online ) with camera license & 2 No's. of client licenses
PC for Monitoring camera
42" Colour LED monitor as per technical specification
Aspiration based Detection System
Aspiration Detection Panel for Server Room
Power Supply Unit with accessories as per technical specification
Electronic Hooter
Fire Suppression System
120 Ltr seamless cylinder with valve
Master Cylinder Kit with following items - Pr. Guage + Low Pr. Supervisory Switch - Electromagnetic Actuator - Manual Actuator - Pneumatic Actuator - Flexible Discharge Hose - Flexible Actuation Hose
End Slave Cylinder Accessories as per technical specification Pressure Operated Control Head Actuation Hose, 30" Discharge Hose, 2" x 31"
Gas Discharge Nozzles
Gas Release Panel
Abort Switch
Release Switch
Hooter with Power Supply
Rodent Repellent System
Rodent Repellent System with stands
Water Leak Detection System
Water Leak Detection Panel with Modbus connectivity
Water Leak detection Cable Sensor – 10 mtrs
Water Leak detection Cable Sensor – 25 mtrs
Electronic Hooter
Workstation Operator Machine: Intel i3 processor 3rd generation, 500GB HDD, 4GB RAM, 52X CD RW ,21" colour monitor, USB Mouse, 2 serial, 1 parallel port & Windows operating system
Building Management System Software
Colour Laser Printer
32 Bit DDC Controller above along with System Integration Units, Powder Coated cabinets as per IS Standards for Electrical Panels and all internal terminations and cabling to monitor temperature & humidity in server room DDC for intergartion of variours physical security substems mentioned and Temperature and humidity monitoring as per IO summary PAC Units Integration (30 Points / Unit) UPS Units Integration (30 Points / Unit) Fire Alarm System Water Leak Detection System
Temperature & Humidity Sensor
TV Screens for Manager Cabins with wall mounted 32" LED TV screen for DC manager Cabin-01 and -02
Monitor Screens for Manager Cabin-03: Wall mounted 42" LED Monitor screen for DC manager Cabin-03 with required length of VGA/HDMI Cable
Data Center Infrastructure Management software per rack perpetual license for 80 Racks and as per RFP specification DCIM (Data Center Infrastructure Management) Application for Power, Cooling, Space, Environment, Safety , security Infrastructure devices Monitoring & Management to meet RFP compliance. Non IT Devices: (Device to be Monitored & Managed, Rack, PDU, Energy Meters, UPS PAC, DG set, FSS, FDA, WLD, RRD) Network Infrastructure Monitoring Application ModuleT&H Sensors- 26 No's. Temperature & Humidity Sensor (RS485, Modbus) - Minimum Capability - a. Should have digital dispay, b. 2 RS485 communication port, c. Temperature measurement accuracy +3 or -3 degree, d. Humidity measurement accuracy +5 % or -5 %, e. should have local alarm for identification. Controller-2 No's. Minimum Capability - 1. Should be capable to monitor up to 20 temperature & humidity sensors, up to 16 intelligent devices (snmp & RS485 modbus enable, 2. built in webpage of its own for monitoring 3. local storage of data upto 7 days 4. should be capable of sending email notification directly, 5. should be capable to share data with third party application over Modbus-IP or BacNet-IP or SNMP polling & trap.
Description of Work / Item(s)
Amount
Project Manager Overall in charge responsible for All Non-IT Activities RSDC P-1, P-2 & P-3
Supervisor- Overall in charge responsible for All Non-IT Activities RSDC P-1, P-2 & P-3
Electrician, UPS and DG Operator cum Mechanic
PAC and CAC Operator cum mechanic
Security staff
BMS Operator
Housekeeping
Description of Work / Item(s)
Amount
Air Conditioners (Daikin Make) as installed at site
Ceiling mounted cassette type Acs-1.06 TR
Ceiling mounted cassette type Acs-1.32 TR
Ceiling mounted cassette type Acs-1.65 TR
Ceiling mounted cassette type Acs-2.08 TR
Ceiling mounted cassette type Acs-2.65 TR
Ceiling mounted cassette type Acs-3.3 TR
Ceiling mounted cassette type Acs-4.13 TR
Wall mounted cassette type Acs-0.66 TR
Wall mounted cassette type Acs-1.06TR
Wall mounted cassette type Acs-2.08 TR
Wall mounted cassette type Acs-0.83 TR
PRECISION PACKAGED UNITS (Emerson Make) as installed at site. 20 TR (min) sensible capacity Precision air - conditioning unit for Datacenter.
UPS (Emerson Make) for item no 15, 17 as installed at site.
20 KVA 3 Phase UPS
12V 42AH(ROCKET) Each bank consists 34 batteries.
80 KVA 3 Phase UPS
12V 200AH (ROCKET) Each bank consists of 34 batteries.
Light Fittings & Luminiar (Bajaj Make) for item no 20, 21,22,23,24 as installed at site.
2X36 Watt CFL/LED light panel (Recess)
2X18 Watt CFL/LED light panel (Recess & surface)
1200 mm sweep 5 star ceiling fan
400mm sweep wall fan
1X28 watt T-5 Light
Fire Detection & sprinkler System (Siemens make) for item no 26, 27, 28,29,30,31 as installed at site.
100mm Gun metal butterfly valve
63 mm dia 15 Meter long RRL pipe
First Aid hose reel & drums
1 Loop microprocessor based addressable analog fire alarm control panel.
Hooter
Fire Supression System for serverfarm area for item no 33, 34, 35,36, 37,38 & as installed at site.
80 Leters seamless NOVEC cylinders
Manual release unit & abort
Sinorix1230
Discharge nozzles
Optical smoke detector
Gas release panel
DG sets (Cummins-Sudhir make) for item no 40 & 41 as installed at site.
200 KVA, 415 volt, 50 Hz, 3 phase AC silent DG set
125 KVA, 415 volt, 50 Hz, 3 phase AC silent DG set
LT Panels for item no 43 & as installed at site.
comprising of following: 630 Amp, FP,50 KA MCCB-1 No), (300 Amp,FP,25 KA MCCB-1 No), 300 A, FP, contactor-1 No), (400A TP 35 KA MCCB-1 No), (250 A TP 25 KA MCCB-1 No), (160 A TP 16 KA MCCB-1 No)(63 A, FP,10 KA, c curve MCB-1 No), 63A, FP,10 KA, c curve MCB-4 Nos, APFC section capacitor Bank-100 KVAr, AMF section, protection section, meeting section.
Description of Work / Item(s)
Amount
Electrician, UPS and DG Operator cum Mechanic
One No. PAC and CAC Operator cum mechanic
Description of Work / Item(s)
Amount
One time repair charge for equipment’s of RSDC P-1 as mentioned in Annexure-1
One time repair charge for equipment’s of RSDC P-2 as mentioned in Annexure-2
One time repair charge for equipment’s of RSDC P-3 as mentioned in Annexure-3
Description of Work / Item(s)
Amount
BoQ-1 Overall Maintenance for 36 months for items installed in RSDC P-1 as per items details enclosed in Annexure-1 of RFP. The Maintenance is to be carried out as per maintenance schedule of Original OEM. The bidders should have back to back to maintenance contract for 24 X 7 with original OEM of items installed as per details given in RFP.
BoQ-2 Overall Maintenance for 36 months for items installed in RSDC P-3 as per items details enclosed in Annexure-3 of RFP. The Maintenance is to be carried out as per maintenance schedule of Original OEM. The bidders should have back to back to maintenance contract for 24 X 7 with original OEM of items installed as per details given in RFP.
BoQ-3 Overall Operation for 36 months for Systems installed in RSDC P-1 & P-3 as per items details enclosed in Annexure-1 & 3 and as per number of persons / shifts details, Service Level Agreements (SLA) given in RFP. The bidder has to deploy the manpower at site at both data center premises as per details given in RFP.
BoQ-4 Overall Maintenance for 36 months for items installed in RSDC P-2 as per items details enclosed in Annexure-2 of RFP. The Maintenance is to be carried out as per maintenance schedule of Original OEM. The bidders should have back to back to maintenance contract for 24 X 7 with original OEM of items installed as per details given in RFP.
BoQ-5 Overall Operation for 36 months for Systems installed in RSDC P-2 as per items details enclosed in Annexure-2 and as per number of persons / shifts details, Service Level Agreements (SLA) given in RFP. The bidder has to deploy the manpower at site at both data center premises as per details given in RFP.
BoQ-6 Total One time repair cost of infrastructure (if required) as mentioned in Annexure-1,2 and 3
Blue Star Ltd.
SHUBHAM ELECTRICALS AND MAINTENANCE
Blue Star Ltd.
SHUBHAM ELECTRICALS AND MAINTENANCE
Blue Star Ltd.
Blue Star Ltd.
Blue Star Ltd.
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .