| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC NAMOPARA PURULIA | PURULIA | PURULIA | WEST BENGAL | 723101 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹7.0 L+₹10,578.82 (1.54%)Rejected-AOC RANCHI ROAD BANS BANGLOW PURULIA | PURULIA | PURULIA | WEST BENGAL | L2 | Rejected-AOC 2nd lowest bidder | |
| 3 | L3₹7.0 L+₹11,537.23 (1.68%)Rejected-Finance RADHAKRISHNA MORE | L3 | Rejected-Finance 3rd lowest bidder |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
29 Jan 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer, PMD,PHE.Dte
Office of the Executive Engineer Purulia Mechanical Division,PHE.Dte Ranchi Road,Purulia.
Construction of Big Dia RBTW (200mm x 150mm) with supply, delivery and installation of solar powered submersible pump at Guniyara village, Neturia Block in Purulia District under Purulia Mechanical Division PHE.Dte.
2021_PHED_315687_1
NIET No. 12/EE/PMD/PHED of 2020-21
Open Tender
MECHANICAL
Item Rate
30 days
Purulia
Please refer Tender documents.
6 documents required · 6 mandatory
₹16,000
Yes
31 Mar 2021
14 Jan 2021
1 Feb 2021
14 Jan 2021
29 Jan 2021
14 Jan 2021
120 days
Amount
Drilling a bore hole in DTH process through any kind of soils and rocks in overburden suitable for lowering and fitting fixing of 200 mm outer dia casing pipe(casing pipe will be supplied departmentally) up to an average depth of 25±5 mtrs. and subsequently 165 mm diameter boring through any kind of rocky formation upto a total depth of 170 mtrs (for dry drilling or sufficient water not achieved drilling may be continued to 200 Mtr) including all other works necessry for boring and lowering fitting fixing of UPVC casing pipes suitable for 165mm dia drilling in rock bed and grouting the same as per direction of E.I.C Necessary arrangement to be made for proper security of bore hole. (Rates are inclusive of all materials necessary for drilling works) a) 0 to 30 Mtrs/Over burden which one is more
b) 30mtrs /over burden to 200 Mtrs or above
Supply & delivery of 7” (175 mm) nominal dia UPVC casing pipe (minimum wall thickness 8.8 mm) having 3.0 meter length each, both end threaded and one end socketed as per direction of EIC and as per IS-12818-1997 Make:- Oriplast/Utkarsh/Supreme/Dupoll NB:- Materials to be supplied as per requirement of site.
Excavation of earth for Construction of 1.45 mtr dia concrete platform in 1:2:4 ratios (plaster with neat cement finish) with 20 mm down stone chips and avg. drain lenght of 2.5 mtr. as per practically feasible in site and design with 1:50 step grouting and fitting fixing of I.M-II hand pump assembly including lowering of 32 mm dia G.I riser pipe minimum depth of 24 mtrs as per direction of E.I.C including carriage and all other charges for executing the works as per BIS Note:- a) UPVC casing pipes should be properly inserted or lowered in overburden zone for proper RBTW formation. b) In case of collapse in borehole, payment will be done for clear measurable depth only. c) IM-II hand pump set will be supplied departmentally.
Supply, delivery & installation of 1200 watt peak capacity Solar photovoltaic array along with 1.00 HP capacity A.C Submersible pump (suitable for Solar) of approved make which output not less than 2000 ltr per hour at 40 mtr head including supply of all necessary materials of approved quality, labour etc. with all allied works as per approved design and direction of EIC. System must be provided with 2.5 mm2 3 core submersible copper cable and rain protected control Panel. The pump outer dia should not be more than 96 mm with outlet 32 mm dia (the pump and the controller must carry manufacturer’s warranty for at least 5 years ). The cost also includes earthing of the system by 50 mm dia G.I. pipe (ISI medium) 3.64 mm thick and 3.04 mtr long as per IE and PWD rules. [NB: 1. Latest MNRE (GOI) guidelines are to be followed strictly for execution of works 2. There must be provision for remote monitoring of the installed pumps as per MNRE guidelines.] (Test certificate along with curve chart should be submitted at the time of delivery)
Making structure for installation of Solar photovoltaic array panels as per standard and approved drawing which will be grouted either ground based by construction of foundation concrete or integrated with the staging M.S structure (painting with appropriate weather coat) above water tank. The Solar panels will be connected to the pump controller by supplying required size cable which will be connected to the pump as well as level sensor of the water tank as per direction of EIC.
Supply, delivery and erection of pre-fabricated M.S structure of 3.00mtr height above G.L for resting of 5000 Ltr capacity PVC water storage tank capable of withstanding extreme weather conditions including wind velocity upto 100 K.M/ Hour with fixing of necessary MS ladder, railing and painting with approprite weather coats including construction of RCC foundation (column structure) and all allied works as per approved drawing and direction of the EIC.
Supply & delivery of one no. 5000 ltrs. capacity multilayer PVC water storage tank and installation of the same at a height of 3 mtr. staging on the M.S main structure as per direction of EIC. (Make: Patton / Sintex / Approved make)
Supply, fitting & fixing HDPE & UPVC pipes (medium duty) for rising main, delivery main, overflow, washout pipe line with distribution pipe line in underground work of conforming to ASTDM-1785 and threaded to match with G.I. pipes as per IS:1239(Part-1)with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbow, nipple, long screw, reducing tee, short pieces etc. fitted including cost of all materials, jointing materials, cutting pipes, making threads, cutting trenches upto 1.5 mtr below surface in all short of soil and refilling the same as directed complete in all respect. (Make: Approved make)(pipes should be layed as per requirement of site and as per direction of EIC.) a) 32mm dia HDPE pipe
b) 40mm dia UPVC pipe
c) 32mm dia UPVC pipe
d) 25mm dia UPVC pipe
e) 15mm dia UPVC pipe
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq.cm.) (Make: Approved make) a) 40 mm dia
a) 32 mm dia
b) 25 mm dia
Construction of RCC street stand post with platform, drain, drilling & tapping water main, supplying & fitting fixing 15 mm dia brass ferrule,20 mm dia G.I pipe (3 mtr Avg. length) with all necessary specials like20 mm G.I bend, nipple, socket, jamnut, 20x15 mm G.I reducing socket, metal bibcock etc. all complete as per approved drawing and direction of the E.I.C.
Making wire net fencing around the Solar panel platform by supplying and fitting fixing of galvanized M.S angle of approved quality which will be grouted in earth by cement concrete as per drawing including an arrangement for a gate with lock and key facility as per direction of EiC.
Supply delivery fitting and fixing of special GI fabricated water chamber as per specification over and above the third plate of the hand pump as per drawing including all fitting materials as per direction of EIC.
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm.
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety
Brick work with 1st class bricks in cement mortar (1:4) In foundation and plinth
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (b) 15 mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Supply, fitting & fixing UPVC pipes (medium duty) for rising main, delivery main, overflow, washout pipe line with distribution pipe line in underground work of conforming to ASTDM-1785 and threaded to match with G.I. pipes as per IS:1239(Part-1)with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbow, nipple, long screw, reducing tee, short pieces etc. fitted including cost of all materials, jointing materials, cutting pipes, making threads, cutting trenches upto 1.5 mtr below surface in all short of soil and refilling the same as directed complete in all respect. (Make: Approved make)(pipes should be layed as per requirement of site and as per direction of EIC.) a. 25mm dia UPVC pipe
b. 15mm dia UPVC pipe
supply delivery & installation of Chrome plated gravity Cock / Stop Cock with plastic inlet 15 mm dia.
Construction of underground structure (soakwell) that disposes of unwanted water into ground. Dimension of soakwell is (1m x 1m x 1.2m) m3 and four wall make by bricks works with holes upto 0.9m from the base and continue of bricks works with 1:6 cement mortar up to 1.2m for holding cover plate after that soakwell fill by blast bricks (1/2 to 1/4 parts of brick) as 0.6 m3 of total volume and 0.3 m3 by Gravel & Cosrse sand and complete the job as per direction of EIC.
Construction of R.C.C slab (1:1.5:3) with stone chips and necessary reinforcement upto 1% (including main and distribution bars), shuttering and 10 mm. thick cement plaster (1:4) including all moulding, drip course etc. complete in ground floor. 50 mm thick using steel of SAIL/ TATA/RINL.
Dismantling of boundary wall / Entrance of School for movement of Rig Bore machine and after completion of job reconstruction that as early as possible. (If necessary) Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.
Brick work with 1st class bricks in cement mortar (1:4) (a) In foundation and plinth
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar c. 15 mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. Note: After completed the works site should be clear as per direction of EIC. Other wise it should be considered that the works is incompleted.
Maintenance of whole water supply unit including supply of consumables as & when required for a period of 3 (three) Months
Add GST @12%
MS D.PALIT AND CO.
PROGRESSIVE ENGINEERS CO OPERATIVE SOCIETY LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .