| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | ₹15.8 L Quoted ₹16.5 L | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹16.5 L+₹922.60 (0.06%)Rejected-AOC 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹16.5 L+₹922.60 (0.06%) | L2 | Rejected-AOC Rejected being L2 |
| 3 | L3₹16.8 L+₹32,502.20 (1.97%)Rejected-AOC H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹16.8 L+₹32,502.20 (1.97%) | L3 | Rejected-AOC Rejected being L3 |
| 4 | L4₹18.5 L+₹2.0 L (12.4%)Rejected-AOC GURDASPUR ROAD NEAR SAINIK MANDIR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹18.5 L+₹2.0 L (12.4%) | L4 | Rejected-AOC Rejected being L4 |
| 5 | L5₹20.4 L+₹3.9 L (23.6%)Rejected-AOC | ₹20.4 L+₹3.9 L (23.6%) | L5 | Rejected-AOC Rejected being L5 |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
18 Jul 2023, 6:00 pmClosed
CWE YOL
HQ CWE YOL CANTT
REPAIR AND MAINTENANCE AND IMPROVEMENT OF HT LINES AND CABLES, SWITCH GEAR, PROTECTION SYSTEM, CALIBRATION OF RELAYS AND OTHER CONNECTED WORK AT ELECTRIC INSTALLATION DALHOUSIE CANTT
2023_MES_597419_1
CWE/Y-16/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DALHOUSIE
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) DALHOUSIE
₹36,000
Yes
2 Sept 2023
20 Jun 2023
25 Jul 2023
20 Jun 2023
18 Jul 2023
4 Jul 2023
Amount
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard and dense soil, complete all as specified and directed.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
XLPE HT insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts (Earthed), grade cross sectional area 150 sqmm 3 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured.
Unreinforced precast concrete cable covers class HV, type 1, flat of size 300mm x 180mm x 40mm including taking out old cover, complete all as specified and directed.
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 80mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
Renewal of drop out fuse unit, expulsion type for outdoor air break gang operated switch, single pole, mounted on and including insulators for 11 KV working pressure, fixed to and including MS channels with nuts, bolts & washers etc, synthetic bounded fuse tube complete with line capacity suitable for current carrying capacity upto 100 Amps including taking out old fuse unit all as specified and directed.
Renewal of vertical type air break switch, gang operated, tripple pole, mechnically operated, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length to worked from ground, including locking arrangements , suitable for 11000 volts, 400 Amps current rating complete including dismantling existing air break switch all as specified and as directed.
Cutting/ trimming of tree branches clearing 5 metres horizontal and 5 metres vertical distance from both sides of HT conductor including removing branches from site, complete all as specified & directed. Note:- (i) Clearing branches from both sides of conductor in between two consequtive poles shall be considered as one span irrespective of distance between poles. (ii) Cost of T&P required for cutting and removing branches shall be deemed to be included in rate quoted by bidder.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including cutting and removing existing unserviceable joint, including earth work complete, near 2 pole structure / HT Panel board / transformer and taking out loop cable from trench and refilling the trench with excavated material all as specified and as directed.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185sqmm including cutting and removing existing unserviceable joint, including earth work complete, near 2 pole structure / HT Panel board / transformer and taking out loop cable from trench and refilling the trench with excavated material all as specified and as directed.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sqmm including cutting and removing existing unserviceable joint, including earth work complete, near 2 pole structure / HT Panel board / transformer and taking out loop cable from trench and refilling the trench with excavated material all as specified and as directed.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm including cutting and removing existing unserviceable joint, including earth work complete, near 2 pole structure / HT Panel board / transformer and taking out loop cable from trench and refilling the trench with excavated material all as specified and as directed.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sqmm including cutting and removing existing unserviceable joint, including earth work complete, near 2 pole structure / HT Panel board / transformer and taking out loop cable from trench and refilling the trench with excavated material all as specified and as directed.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm including cutting and removing existing unserviceable joint, including earth work complete, near 2 pole structure / HT Panel board / transformer and taking out loop cable from trench and refilling the trench with excavated material all as specified and as directed.
Disconnecting the electric supply from the existing RMU/VCB/Transformer/HT poles and meggering the HT under ground cable for its IR value and ensuring the servicebility by HT megger,locating the faults by HT fault finder instrument for any distance and reconnect the HT cable. NOTE:- Earth work included in the quoted rate (ii) Joint kit and HT UG Cable shall be measured and paid separetly.
Renewal of pin type insulator porcelain, vitreous, white/brown or green including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm dia and 150mm height for working pressure 11000 volts grade includng taking down existing insulators and removing from site, complete all as specified.
Renewal of disc type insulator, 145 mm height 255 mm dia suitable for 11000 volts HT grade porcelain vitreous white,brown or green including galvanized mild steel sectional straps 38X5mm, insulator bolts dia 20mm, washers and nuts includng taking down existing insulators and removing from site complete all as specified and directed.
Painting to four pole structure made out of steel tubular HT poles, 11m long including cross arms, channels, angle iron support, bracings, clamps, XPM jalli etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed.
Painting to two pole structure made out of steel tubular HT poles, 11m long including cross arms, channels, angle iron support, bracings, clamps, XPM jalli etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed.
Painting to existing steel tubular HT poles, 11m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed
Renewal of lightning arresters (Set of three) expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp for 11000 volts including taking out old unservicable arrester and removing from site complete all as specified and directed.
Carrying out calibration of HT VCB switchgear 800/630/400 Amps, and 11 KV HT RMU SF6 VCB breaker all as per OEM instructions (Make:ALSTOM/Yamuna power/ CG/ AREVA /ABB) after taking proper shut down and disconnecting the cables from panel and VCB Breakers, calibration of over fault relay, earth fault relay, checking of alignment of VCB isolating contacts, servicing of operating mechanism including tripping and closing system of the breakers, dehydrating, decorbonising of panel, bus section & circuit section including incoming/outgoing cable and necessary HT insulation at joints. Removing perished monoplus compound cleaning and re-insulating with HT taps wherever necessary, with and including replacement of burnt out/defective spares like tension springs, tortion springs, nut bolts, washers of suitable size, lingers etc., under the supervision of authorised dealer/ representative, and refixing the panel in its original position and testing entire satisfaction of Engineer -in- Charge .Note : (i) The quoted Rate shall be deemed to include of visiting and inspection of VCBs/RMU of technician/mechanic and minor spares etc. (ii) If any burnt out/defective items like moving/fixed contacts, tripping coils,earth fault relay etc,will be measured and paid separately under respective items. (iii) Labour and T&P required for fixing of supply only items shall be deemed to be included in Unit rate quoted by bidder againest this job.
Supply only Socket Contact 630/800A suitable for VCB trolly as per existing make and model 11 KV,400/630/800 Amps complete all as directed.
Supply only Vacuum Interrupter Assembly with Flex connection suitable for VCB as per existing make and model 11 KV,400/630/800 Amps complete all as directed.
Supply only Shunt Trip Coil 24V DC (OG 835) / 220V AC (OG 870) suitable for VCB as per existing make and model 11 KV,400/630/800 Amps complete all as directed.
Supply only Motor Charge Spring Mechanism assembly complete fitted with close/ trip Coils (Mention trip, close & motor voltage) Motor with Gear Assly 110V AC/220V AC,Gear Box for Motor with Gear Assembly (Bosch make)110V AC/220V AC, Ratchet wheel Assebly all as specified and directed.suitable for VCB as per existing make and modle 11 KV,400/630/800 Amps complete all as directed.
Supply only Solenoid Mechanism (SX-15) with coils & aux. switch (Mention trip & close voltage) suitable for VCB as per existing make and modle 11 KV,400/630/800 Amps complete all as directed.
Supply only Carriage Assembly for breaker complete with Lead Screw with Bevel Gear, Lifting Nut (Brass) Pinion Assembly, Lifting Shaft Bush, Modified Bell Crank suitable for VCB as per existing make and modle 11 KV,400/630/800 Amps complete all as directed.
Supply only Secondary Plug and socket set Board Assembly (28 WAY)suitable for VCB as per existing make and modle 11 KV,400/630/800 Amps complete all as directed.
Disconnecting the electric supply from the existing VCB and disconnect the existing unserviceable/Brunt current transformer set (Set of 3 Phase) from VCB panel and supply & Fixing and testing in replacement new resin cost current transformer set (Set of 3 Phase)11000 Volts HT copper wounded with mild steel parts 100/5 +5 voplts single phase class 0.5 of air cooled accurecy dry type VA15,VK ≥ core 1 R at 75 C as per IS-2705, IEC-60044 connection with panel, properly after installation and testing complete all as directed.
Disconnecting the electric supply from the existing VCB and disconnect the existing Potential transformer set (set of 3 Phase) indoor type with panel and supply & Fixing and testing in replacement new resin cost Potential transformer set (set of 3 Phase) 11000 Volts HT copper wounded with Ratio 11000 Volts/110 Volts burden 100VA-3V class-I 50 HZ , HSV-12 Volts secondry voltage 110 dry type as per sample,properly connection with HT panel after installation and testing complete all as directed.
Supply only Breaker control switch (TNC) Trip,Neutral,Close (32/40A/660V AC) suitable for VCB as per existing make and modle 11 KV,400/630/800 Amps complete all as directed.
Supply only Push to Trip Knob (Red & Green) Assembly With spring & Housing suitable for VCB as per existing make and modle 11 KV,400/630/800 Amps complete all as directed.
Supply only master trip relay mechanical 4No + 4NC, 110 V for VCB 800/630/400 Amps capacity, as per existing make and modle Suitable for type VCB:-VMX/UNIVAC complete all as directed.
Supply only HRC Fuse-Pt HT Side(VTF-11, 3A / VTF 6.6, 3A) suitable for VCB as per existing make and modle 11 KV,400/630/800 Amps complete all as directed.
Supply only Isolating Contact Flat Type - 800/630A suitable for VCB as per existing make and modle 11 KV,400/630/800 Amps complete all as directed.
Supply only Hand Charge spring mechanism (SPX) with coils (Mention trip & close voltage) suitable for VCB as per existing make and modle 11 KV,400/630/800 Amps complete all as directed.
Supply only for three phase Voltmeter 11 KV digital type suitable for VCB 11 KV panel,400/630/800 Amps complete all as directed.
Supply only for three phase Amp meter 11 KV digital suitable for VCB panel ,400/630/800 Amps complete all as directed.
Supply only for Phase Indicator of red,yellow,blue,green 230V or 110V suitable for for VCB 11 KV,400/630/1200 Amps complete all as directed.
Supply only charging motor 230V DC/AC for VCB 400/630/800 Amps capacity, Type:-VMX/UNIVAC complete all as directed.
Supply and installation in replacement of Over current and earth fault relay Auxiliary universal supply 18-52 V AC/DC operated, Digital I/P + O/P(Make: CG/L&T/ ABB) self powered CGI 14N/14C suitable for VCB for VCB 800/630/400 Amps capacity, NOTE : (i) Fixing of protection relay shall be carried out through O.E.M of manufacturer's engineer /technician only complete all as specified & directed.
Supply only Release / Closing Coil 12V/24V DC to 220V DC for VCB 800/630/400 Amps capacity,Type:-VMX/UNIVAC. Note :- for Item No 25.0 to 46.0: The spares shall be measured and paid only when required at site during servicing of VCBs.
Dehydration, filtration, heating and refilling of old transformers oil after testing the same for dielectric strenghth not less than 45 KV (RMS). Note:- (a) Dehydration and filtration can be carried out at site by dehydration machine otherwise the same shall be got done from the manufacturing workshop of transformers complete all as specified.(b) Contractor shall ensure no wastage of transformer oil.(c) Safety of transformer during filteration shall solely be the responsibility of contractor and any damaged caused to transformer during the operation of filteration shall be made good by contractor at his own and no claim for any expanditure on this account shall be entertained during execution of work or later stage.(d) Contractor shall ensure that the conservator tank are full before starting the dehyderation.(e) Testing of transformer oil for BDV and acidity as per IE rules all as specified and directed.(f) Test results shall be submitted to Engineer-in-Charge equipment wise.
Supply and top up of transformer insulating oil HV grade having die-electric stength not less than 45 KVA (RMS) at 2.5mm gap. Make: Transoil/Power Oil Savita
Carrying out servicing and calibration of oil circuit breaker of HT 11 KV OCB by draining out insulating oil and refilling fresh oil, including replacement of defective contacts/ parts and making functional complete, checking all moving mechanism all as required for making functional complete all as directed in instruction of manual of VCBs operating mechanism for smooth and trouble free operation of the system including below:- (a) Adjustment of contact gap for proper functioning. (b) Adjustment of spring operated front shutter for operator's safety. (c) Callibration of circuit breaker for over current, short circuit and earth fault with the help of CT and associated to meet optimum operational requirement. (d) Cleaning of VCB with air blower and removing dust particals. (e) Cleaning and arching contact gap of vaccume intreputer if gap exceeds permissible limits. (f) Checking/ repair replacement of all electrical wiring of electric/ mannual operation including measuring IR values. Note:- (i) Insulating oil shall be measured and paid under respective Item of BOQ. (ii) Labour and T&P required for fixing of supply only items shall be deemed to be included in Unit rate quoted by bidder againest this job. (iii) Cost of necessary tools and plants and transpotation to workshop and return back at site such as Vehicle, hydra/crane etc should be deemed to be included in the unit rate quoted.and refixing at the same at site as per direction by Engr-In-Charge.
Carrying out servicing at site disconnecting / dismantling carefully primary & secondary HT/LT connection from transformer for servicing of capacity 63 KVA to 160 KVA complete,Opening the transformer, safely collecting transformer oil, taking out core of transformer by disconnecting the same from HT/ LT bush rods ,Checking /Repair /Replacement of HT/LT Bush,cork sheet etc. Assembly of transformer after carrying out the repair work and making all HT/ LT connections with respective bush rods. Note : (i) The quoted Rate shall be deemed to include of visiting and inspection of Transformer of technician/mechanic. (ii) Labour and T&P required for fixing of supply only items shall be deemed to be included in Unit rate quoted by bidder againest this job. (iii) Installation of transformer on locations as directed by Engineer in Charge on existing HT pole structure/ plinth and making all HT/ LT and earth connections including testing the transfromer complete all as directed. (iv) Cost of necessary tools and plants and transpotation to workshop and return back at site such as Vehicle, hydra/crane etc should be deemed to be included in the unit rate quoted
All as per item Ser No.50 here in before but of capacity 200 KVA to 400 KVA compete all as specifed
Supply only Ceramic Bush insulators with brass spindle rod complete with cork sheet gasket, washers, nuts and check nuts on HT side as per existing size, shape and specification for 11/0.433 KV transformer (outdoor/indoor) type transformers of capcity not exceding 160 KVA complete all as specified
All as per Item Ser No.52 here in before but capcity 200 KVA to 400 KVA complete all as specified
Supply only Ceramic Bush insulators with brass spindle rod complete with cork sheet gasket, washers, nuts and check nuts on LV side as per existing size, shape and specification for 11/0.433 KV transformer (outdoor/indoor) type transformers of capcity not exceding 160 KVA complete all as specified.
All as per item Ser No. 54 here in before but capacity 200 KVA to 400 KVA compete all as specifed.
Supply only cork sheet gasket of 6 mm thick size/shape for top cover of transformer upto capacity 63 to 400 KVA.
Supply & Fixing in replacement air breather assembly of metallic body complete filled with fresh blue coloured silica gel suitable for indoor/out door type transformer of capacity 63 KVA to 400 KVA.
Supply only fresh silica gel in breather assembly of transformer all as specified and directed.
Painting of transformer externally (indoor/ outdoor type) with one coat of smoke grey colour synthetic enamel paint using spray gun over the existing paint after cleaning and removing the dust and dirt and cleaning with thinner and scrapper/ sand paper and preparing surface for painting complete including writing SM Nos on transformer body with letters 50mm high with white synthetic enameled paint complete for transformer of capacity upto 100 KVA without disturbing the supply including preparing surfaces of plateform and applying one coat of colour wash complete all as specified and directed. Note: Write with white paint on body of transformer " Date of Dehydration". ............................, "Date of Top Up of Transformer Oil".
Painting of transformer externally (indoor/ outdoor type) with one coat of smoke grey colour synthetic enamel paint using spray gun over the existing paint after cleaning and removing the dust and dirt and cleaning with thinner and scrapper/ sand paper and preparing surface for painting complete including writing SM Nos on transformer body with letters 50mm high with white synthetic enameled paint complete for transformer of capacity 150 KVA to 400 KVA without disturbing the supply including preparing surfaces of plateform and applying one coat of colour wash complete all as specified and directed. Note: Write with white paint on body of transformer " Date of Dehydration". ............................, "Date of Top Up of Transformer Oil".
Disconnecting / dismantling carefully primary & secondary HT/LT connection of unserviceable/ serviceable out door/indoor type Transformer up to 400 KVA complete its foundation/substation and safely shifting one sub station to another sub station as directed by Engr-in-Charge and reconnection of cabling, earthing, install testing and commissioning of the Transformer complete all as specified & directed. Note: Cost of necessary tools and plants such as Vehicle, hydra/crane etc should be deemed to be included in the unit rate quoted.
M&L for complete rewinding of unserviceable off load burnt transformer of HV copper coil and LV copper coil using proper size DPC super enameled copper winding wire of appropriate guage and grade,with insulation material suitable for 11/0.433 KV transformer capacity upto 250 KVA including repair/replacement of damaged core also taking out carefully burnt unserviceable copper winding of coils & core complete all as specified and directed. NOTE- (i) Cost of necessary tools and plants and transpotation to workshop and return back at site such as Vehicle, hydra/crane etc should be deemed to be included in the unit rate quoted (ii) Safety of transformer during Repair shall solely be the responsibility of contractor and any damaged caused to transformer during the operation of repair or in transpotation shall be made good by contractor at his own and no claim for any expanditure on this account shall be entertained during execution of work or later stage.(iii) The bidder strictely should be arrange Joint inspection at work shop with MES Rep (JE E/M /AGE E/M) to ensure damaged of transformer.(IV) Installation of transformer on locations as directed by Engineer in Charge on existing HT pole structure/ plinth and making all HT/ LT and earth connections including testing the transfromer on full load for 3 hours and on 10% extra load for two hours complete all as directed.
All as per item Ser No.62 here in before but capacity 300 KVA to 400 KVA compete all as specifed
Supply and fixing 11000 Volts HT Dropout Fuse element 10A to 60Amps all as pecified and directed.
Supply and laying/spreading for loose filling of Hard core of stone broken or boulders of guage 40 to 80mm at electrical sub station 4 pole/2 pole structure including brick work up to 1 feet hight in CM (1:6), 15mm thick cement plaster in CM (1:6) and preparation of surfaces and applying two coats of white wash complete; all-arround the 4 Pole/2 Pole structure up to area of 25m x 25m complete all as specified & directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25 x 4mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregates reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
M & L in replacement for Earth continuity conductor or main earthing lead fixed to walls on batten or recess or chases or buried in ground or drawn in conduit/pipes or fixed to poles or any other indicated situation for loop earthing etc as required 25X4mm galvanised iron strip all as specified.
M & L in replacement for Earth continuity conductor or main earthing lead fixed to walls on batten or recess or chases or buried in ground or drawn in conduit/pipes or fixed to poles or any other indicated situation for loop earthing etc as required 20x3mm copper strip all as specified.
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 28 of tender doucments.
malghotra construction co
M/s Shakti Electric Works
SAINI AND SAINI BUILDERS
dinesh enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .