AGM(Commercial)
INCOD OFFICE NAVAL DOCKYARD SBS MARG MUMBAI 400023
INSTALLATION OF TEMPORARY MB-SRE, TELEPHONE EXCHANGE AND AFDS FOR INS BRAHMAPUTRA
2024_NAVY_681936_1
DYT/WEA/106(A)/24-25/MB-SRE TELEPHONE EXCHANGE AFDS
Open Tender
Marine Services
Fixed-rate
120 days
NAVAL DOCKYARD MUMBAI
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹80,472
Yes
NAVAL DOCKYARD MUMBAI
10 Dec 2024
31 Oct 2024
12 Nov 2024
31 Oct 2024
11 Nov 2024
5 Nov 2024
5 Nov 2024
Amount
Services: Laying of SRE cables
Services: Fitment of SRE Speakers Scope of work - a. MS brackets . b.Welding of Brackets c. Nut and bolting of speakers
Services: Fitment of Boxes Scope of work - a. MS brackets . b.Welding of Brackets c. Nut and bolting of speakers
Service - Connectorisation of connectors along with associated cable booting
Service – Fabrication of foundation, fitment of foundation, shipping of units to onboard location and installation of units on the foundation for following equipment at various locations onboard ship as per approved drawings. (a) 24U NW Rack (Qty – 04) (b) UPS (c) Battery Bank (d) Junction boxes (02)
Service – Laying of new Telephone exchange cables (laying, dressing and clamping)
Service - Fabrication of foundation, fitment of foundation, shipping of units to onboard location and installation of units on the foundation for following equipment at various locations onboard ship as per approved drawings. (a) 08 in nos of wall mounting bulkhead telephone sets (b) 08 in nos of desk mounting telephone sets (c) 05 in nos of emergency telephone sets (d) 10 in nos of weatherproof portable telephone sets (e) 05 in nos of IP phones telephone sets (f) 20 in nos of Flasher Hooter telephone sets (g) 20 in nos of Amplispeaker Unit Assembly (h) 156 in nos of analog phones (i) 01 in nos main DB (j) 100 in nos Telephone directory (k) 03 in nos of shore line connection Box. (l) 04 in nos. Administrator console, LAN switch POE enable, Media Gateways and FCBC.
Service – Manufacturing and provisioning of securing arrangement for-: (a) 300 in nos of socket boxes (b) 300 in no of Rossette Box
Service - Connectorisation (a) 300 lines (b) 20 in nos. of relays with main DB (c) 05 shore lines to shore line connection box and main DB. (d) 50 in nos. system and Power supply cables.
Service – Fitment of 50 new MCT glands.
Service - Renewal of cable trays 60 mm (provisioning, installation and removal of old cable tray including hot work)
Service – Proper earthing/ bonding of all units of as per NEC standard (NEC-STD 1101)
Service – Termination of old/ unused cables by terminating the shield circumferentially and grounding the core at both ends.
Service - Fabrication and fitment of clamps for mounting of channel trays and bulkhead mounted devices as required for all units of Telephone Exchange in all compartments.
Service – Manufacture and fitment of cable tallies 6x3x0.5mm – Aluminum (punched) for all cables of all units of Telephone Exchange in all compartments.
Service – Provisioning of all tools, equipment, slings, vehicles or any other item required for undertaking above mentioned work.
Service – Laying of new cable (laying dressing and clamping) 8.6 (sq mm ) 3 core
Service – Laying provisioning and fitment of cable conduit 60 Sq mm
Service – Renewal of cable trays 60 mm (Provisioning, Installation and removal of old cable tray including hot work). Firm has to provide Cable trays
Material and Service – Manufacture of MCTA and PMT glands for laying of cables from one deck to other.
Service – End connection of all cables in respective units/sensor
Material and Service – Manufacturing and fitment of cable tallies 6x3x0.5mm - Aluminium (punched)
Material - Installation of BS-420M Fire alarm panel. max 6(+6)addr. Loops, (ea127 units) including insert sheet (116-E-2879/GB-G)
Service - Installation of BS-420M Fire alarm panel. max 6(+6)addr. Loops, (ea127 units) including insert sheet (116-E-2879/GB-G)
Material - Installation of FL Switch SFNT 4TX/ FX, 4RJ/ 1MM Optical, 24 Vdc/ 160mA
Service - Installation of FL Switch SFNT 4TX/ FX, 4RJ/ 1MM Optical, 24 Vdc/ 160mA
Material - Installation of FL Switch SFNT 8TX/ FX, 8RJ/ 1MM Optical, 24 Vdc/ 160mA
Service - Installation of FL Switch SFNT 8TX/ FX, 8RJ/ 1MM Optical, 24 Vdc/ 160mA
Material - Installation of Operator panel, for AutroNet (Ethernet) including Insert sheet (116-E-2879/ GB-G)
Service - Installation of Operator panel, for AutroNet (Ethernet) including Insert sheet (116-E-2879/ GB-G)
Material - Installation of Repeater or Info Panel, 16x40 car., for AutroNet (Eithernet) including insert sheet (E-2880/ GB-G)
Service - Installation of Repeater or Info Panel, 16x40 car., for AutroNet (Eithernet) including insert sheet (E-2880/ GB-G)
Material - Installation of Repeater Panel - Loop powered 16x40 car., for AL - Com Detector Loop
Service - Installation of Repeater Panel - Loop powered 16x40 car., for AL - Com Detector Loop
Material - Installation of Manual call point BF500V2/ EX SV, IP44 Weather Proof
Service - Installation of Manual call point BF500V2/ EX SV, IP44 Weather Proof
Material - Installation of Heat Detector head SV, (Config. 56-88 deg C), IP44D (conduit box)
Service - Installation of Heat Detector head SV, (Config. 56-88 deg C), IP44D (conduit box)
Material - Installation of Optical smoke Detector head SV, IP44D (conduit Box)
Service - Installation of Optical smoke Detector head SV, IP44D (conduit Box)
Material - Installation of Autroflame Dual IR Loop powered & SCI, IP67 for AP and AS 4
Service - Installation of Autroflame Dual IR Loop powered & SCI, IP67 for AP and AS 4
Material - Installation of Multi Sensor head, Smoke/ Heat, IP44D (conduit box)
Service - Installation of Multi Sensor head, Smoke/ Heat, IP44D (conduit box)
Material - Installation of Heat Detector head, (Config. 56-88 deg C) Exi/ IICT5 IP44D SV Z-1
Service - Installation of Heat Detector head, (Config. 56-88 deg C) Exi/ IICT5 IP44D SV Z-1
Material - Installation of Sounder, Roshni 10 cm, 24v DC/ 35 MA 112 Dba, IP44 Rd
Service - Installation of Sounder, Roshni 10 cm, 24v DC/ 35 MA 112 Dba, IP44 Rd
Material- Installation of Siren/ Beacon, Flashni 101 Dba/2.5J, 24V DC/ 68 MA Red, IP65/ glands
Service - Installation of Siren/ Beacon, Flashni 101 Dba/2.5J, 24V DC/ 68 MA Red, IP65/ glands
Material - Installation of Ex interface unit, Exialic, 1 Branch, , < 20 det. (sep. 24V, Rev3
Service - Installation of Ex interface unit, Exialic, 1 Branch, , < 20 det. (sep. 24V, Rev3)
Material - Installation of Steel cabinet w/ door AE 1260.500 (H1200xw600Xd300mm) Cutout prep. For ASAFE
Service - Installation of Steel cabinet w/ door AE 1260.500 (H1200xw600Xd300mm) Cutout prep. For ASAFE
Material - Installation of General alarm push button, Flush IP22
Service - Installation of General alarm push button, Flush IP22
Material - Installation of Battery 12v/ 42Ah 14.0Kg, sealed & maint free
Service - Installation of Battery 12v/ 42Ah 14.0Kg, sealed & maint free
Material - Installation of Conduit Box
Service - Installation of Conduit Box
Material - Installation of Relays/ Terminals/ Internal Wiring
Service - Installation of Relays/ Terminals/ Internal Wiring
Material - Installation of EISPL - Transformer – 01
Service - Installation of EISPL - Transformer – 01
SUNSHINE ENTERPRISES (BID ID -3161404)
SINAXIS ENTERPRISES PVT LTD (BID ID -3161056)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .