| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹46.6 L+₹4.4 L (10.5%)Rejected-Finance | L2 | Rejected-Finance Rejected being not lowest |
Tender Value
Refer Docs
EMD Value
₹93,000
Closing Date
7 Jun 2021, 6:00 pmClosed
SK Choudhary EE IDSE GE NW Kochi
GE NW Kochi Kataribagh Naval Base Post 682004
ADDN ALTN AND SPECIAL REPAIRS TO WET CANTEEN BEHIND P 172 PARKING SHED FOR STFF AT ND SCHOOL AND CERTAIN SNCTIONED WORKS OF AGE B R II AND AGE E M UNDER GE NW KOCHI
2021_MES_437860_3
GE(NW)KOCHI/8478/E8
Open Tender
Civil Works
Item Rate
GE NW Kochi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
₹93,000
31 Oct 2021
12 May 2021
9 Jun 2021
12 May 2021
7 Jun 2021
26 May 2021
Amount
M&L for plain cement concrete in 1:4:8 type D2 using 40 mm graded stone aggregate for as in foundations, filling and mass concrete compleate all as specified and directed by Engr-In-Charge.
M&L Pre-Cast cement concrete block type C-1 , 1:3:6 (20 mm graded aggregate) masonary with solid blocks, exc 10 cm width and setting in cement mortar 1:4 compleate all as specified and directed by Engr-In-Charge.
M&L for rendering 15 mm thick cement plaster in CM 1:4 on brick work or concrete surfaces including finishing surface even and smooth w/o extra cement compleate all as specified and directed by Engr-In-Charge.
Dismantling Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings compleste all as specied and directed by Engr-In-Charge.
M&L Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceabletiles to store and rubbish off the premises compleate all as specified and directed by Engr-In-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar all as specified and directed by Engr-In-Charge
M&L 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls all as specified and directed by Engr-In-Charge
M&L for Vitreous China wash basin, white, flat back, size 550 x 400mm excluding ditto but including brackets and similar work for rough finished flat all as specified and directed by Engr-In-Charge
S&F 15 dia Fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixedcomplete all as specified and as directed by Engr-In-Charge .
S&F Tubular brass towel rail, 20mm dia, D type, 60cm long between flanges compleate all as specified and directed by by Engr-In-Charge.
S&F 180 mm dia half round ready made sewage gutter of pressure rating 6 kg/cm2 of approved make including necessary fitting like bend WC/MS clips etc compleate all as specified and directed by Engr-In-Charge.
S&F 150 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls compleate all as specified and directed by Engr-In-Charge.
S&F Rolled sections (Tublar Section) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates compleate all as specified and directed by Engr-In-Charge.
M&LPre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, fixed with self tapping screws as specified compleate all as specified and directed by Engr-In-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified compleate all as specified and directed by Engr-In-Charge.
Compleate removal of existing surfaces finishes of external wall, preparation of surfaces and applying two coats of weather proof (antifungal, Asian Ultra Protetect) paint over a coat of suitable primer over 3 mm thick wall care putty of three layers compleate all as specified and directed by Engr-In-Charge. Note :- Application of paint primer and wall care putty shall be as per manufacturer's instructions.
M&L for preparation and compleate removal of existing treatment and applying two coats of Interior Emulsion (Asian Royale Interior Emulsion) a coat of primer and 3 mm thick wall care putty of three layers compleate all as specified and directed by Engr-In-Charge. Note :- Application of paint primer and wall care putty shall be as per manufacturer's instructions.
M&LDismantling floor, hearth orwall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisescompleate all as specified and directed by Engr-In-Charge.
Taking chowkhats or frames N exc 1.5 sqm in each but with shutters (without taking off shutters from the frames) compleate all as specified and directed by Engr- In- charge.
Taking chowkhats or frames exc 1.5 but exc 4.0 sqm in each but with shutters (without taking off shutters from the frames) compleate all as specified and directed by Engr- In- charge.
S&F for Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified compleate all as specified and directed by Engr- In- charge.Make :- JINDAL or equivalent section from HINDALCO/INDALCO/MS AJITH IND PVT LTD.
S&F Powder Coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specifiedcomplete all as specified compleate all as specified and directed by Engr- In- charge.Make :- JINDAL or equivalent section from HINDALCO/INDALCO/MS AJITH IND PVT LTD.
S&F Powder Coated anodised aluminium 5mm dia hexagonal channel for grill (Decogrill) fixed to aluminium frame with aluminium beeding compleate all as specified and directed by Engr- In- charge. Make :- JINDAL or equivalent section from HINDALCO/INDALCO/MS AJITH IND PVT LTD.
S&F for 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane fix to wood/aluminium joinery compleate all as specified and directed by Engr- In- charge.Hindustan pilkinton glass work Ltd/ Modiguard
M&L Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples compleate all as specified and directed by Engr- In- charge.
M&L 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed compleate all as specified and directed by Engr- In- charge.
M&L 35 mm thich Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats compleate all as specified and directed by Engr- In- charge.
M&L 2nd class hard wood 35 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc.with divided into squares with plain chamfered mitred and rebated sash bars any numbers , edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats compleate all as specified and directed by Engr- In- charge.
S&F 150 mm long aluminium handles cast type anodised compleate all as specified and directed by Engr- In- charge.
S&F for 125 mm Butt hinges, extruded aluminium ally with galvanised mild steel hingepin anodised and fixed Type B-21 compleate all as specified and directed by Engr- In- charge.
S&F for 200 mm lomg aluminium anodised barrel tower bolts of extruded type section compleate all as specified and directed by Engr- In- charge.
S&F for 150 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of truded sections or cast-aluminium alloy and fixed compleate all as specified and directed by Engr- In- charge.
S&F for Door closer hydrau lically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed compleate all as specified and directed by Engr- In- charge.
M&L for preparation of wooden Surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of synthetic eamnel paint over a coat of pink primer compleate all as specified and directed by Engr- In- charge.
M&L for compleate removal by mechanical gridinng and preparing of old steel surfaces of any descrption over 10 cm grith or width not other wise decribed and applying two coats of anti corresive paint over a coat primer compleate all as specified and directed by Engr- In- charge.
M&L for preparation of new surfaces of any description, over 10 cm grith or width not other wise descibed and applying two coats of anti corresive epoxy paint over a coat of Epoxy primer, over a coat of redoxide on steel surfaces compleate all as specified and directed by Engr- In- charge.(Make :- Asian , Apcolite or equvalent from berger , Nerolac)
S&F for in repair suspended false ceiling consisting of 8 mm thick calcium silicate seamless board suspended ob GI frame work with suggested joints, GI frame work to consist GI perimeter channel 25mmx 20mm of 22 gauge along perimeter of false ceiling . Channel section of 50X 25 mm of 22 gauge and 300 mm cetre to centre throught out on way fixed with screw / nut bolt and other direction 40x15 mm 22 gauge channel provided with interlocking with GI cleat and expantion fastners including hangers 6mm dia GI fixed to roof truss, Boards are to be joined and finished so as to have a flush look with includes finishing the tapered and square edges of the gypsum board with joining compound paper tape and two coat plasting emulsion piant over one caot of primer and one layer of putty 3 mm yhick in three layers suitable for calcium silicate board (as per recommandations/practice) including neccessary scaffolding and shutterinng compleate all as specified and directed by Engr- In- charge.
M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface compleate all as specified and directed by Engr- In- charge.
M&L providing 100 mm thick PCC type D2 (using 40 mm graded stone aggregate) as in sub floor etc compleate all as specified and directed by Engr- In- charge.
M&L providing Chequered cement concrete tiles 20cm x20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors/steps including screed bed or bedding layer 15 mm thick in CM 1:4 compleate all as specified and directed by Engr- In- charge.
M&L providing joint free cloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors/steps including screed bed or bedding layer 15 mm thick in CM 1:6 compleate all as specified and directed by Engr- In- charge.
All as above item No 46 here -in- before but on vertical surfaces as skirting including screed bed or bedding layer 10 mm thick in CM 1:4 compleate all as specified and directed by Engr- In- charge.
M&L providing Glazed ceramic tiles in vertical surface 600x 300x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including screed bed or bedding layer 10 mm thick in CM 1:3 compleate all as specified and directed by Engr- In- charge.
M&L providing 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite compleate all as specified and directed by Engr- In- charge.
M&L for rendering 10 mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 including finishinng even and smooth with out using extrx cement compleate all as specified and directed by Engr- In- charge.
Demoiltion Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles compleate all as specified and directed by Engr- In- charge.
M&LFormwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etccompleate all as specified and directed by Engr- In- charge.
M&L providing RCC in Type B1 (using 20 mm grade sone aggregate) as in Beams, cantilivers, bressumm ers, lintels over 1.5m compleate all as specified and directed by Engr- In- charge.
M&L providing RCC in Type B1 (using 20 mm grade sone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like compleate all as specified and directed by Engr- In- charge.
M&L for mild steel TMT bars 10 mm and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with andincluding mild steel wire (annealed) not less than 0.9mm dia or securing with clip all as specified and directed by Engr-In-Charge .
M&L for preparation new plastered internal surfaces and applying two coats of Interior Emulsion (Asian Royale Interior Emulsion) a coat of primer and 3 mm thick wall care putty of three layers compleate all as specified and directed by Engr-In-Charge. Note :- Application of paint primer and wall care putty shall be as per manufacturer's instructions.
M&L for preparation of new plastered surfaces finishes of external wall and applying two coats of weather proof (antifungal, Asian Ultra Protetect) paint over a coat of suitable primer over 3 mm thick wall care putty of three layers compleate all as specified and directed by Engr-In-Charge. Note :- Application of paint primer and wall care putty shall be as per manufacturer's instructions.
S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 compleate all as specified and directed by Engr-In-Charge .
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. compleate all as specified and directed by Engr-In-Charge .
M&L point wiring with 1.5 Sqmm PVC insulated unsheathed FRLS multistranded single core copper conductor cable in PVC concealed conduit rigid non metallic on wall except beam, column and RCC roof and chases cutting incl 1.6 mm thick MS sheet pressed terminal box (recessed) with 3mm thick laminated hylem top cover incl 1.5 Sqmm PVC insulated copper conductor earth continuity wire for one light/fan point controlled by one switch.
All aper Item No 56 here in above one 3 pin socket outlet, 5 Amps controlled by one switch in same board with other switches
All as per item No 56 here in above but for one 5 pin 5 amps socket outlet an independent board.
All as per item No 56 here in above but with 2.5 Sqmm copper conductor including 2.5 Sqmm copper cable on earth wire for one 6 Pin 16 Amps Socket outlet independent board.
All as per item No 56 here in above but with one fan point /exhaust fan point controlled by one switch and rehulator
S&F switch piano flush type 5A one way complete all as specified and as directed.
S&F S/S combination 5 pin 5 Amps flush type complete all as specified and as directed.
S&F S/S combination 6 pin 15 Amps flush type multi purpose complete all as specified and as directed.
S&F ceiling rose surface bakelite 65 x 50mm 3 terminals complete all as specified and as directed.
S & F in repair fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed.
Supply & fix Regal Batten for LED tube lights, both side connection type and LED tube rod 1 x 20 Watt, both side connection all as specified and as directed. Make : Havells Cat Part No. REGALBATTENT8 upto 1x822W SSBSWH for Regal Batten & CRYSTAL 1213T8DSTL20W LED 8655 GLASS for tube rod or Surya/Wipro
S&F 07W LED mirror light fitting with tube and provided with high output diffuser including all electrical connection all as specified and dirceted by Engineer in charge.Cat part no LCL-07-CDL of crompton or Philips/Wipro
Supply and fix LED street light 35/36 W IP 65 protection including all accessories and suitable GI pipe for fixing on wall including all connection all as specified and directed by Engineer in charge. Cat Part No. LSTS-36-CDL-M of Crompton
Taking down old DBs from existing position including MCB,s all as specified and as directed.
S&F Sheet metal enclosure SPN DB when MCB's to be used 8 way with 200 amps bus bar double door complete all as specified and as directed.
S&FMCB SPN 6 to 32 Amp ,240 Volts,10 KA all as specified and directed Cat part No -BB20060B to BB20320B of L&T or Legrand/Indoasian.
S&FMCB SP 6 to 32 Amp ,240 Volts,10 KA all as specified and directed Cat part No -BB10060B TO BB10320B of L&T or Legrand/Indoasian
S & F in repair SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified.
Taking down old sub main wiring of any size
M&L for sub main wiring with 2 runs of 4 Sqmm (FRLSH) PVC insulated unsheathed multistranded copper conductor cable and 1 run of 4 Sqmm (FRLSH) cable as earth continuity wire and including PVC conduit concealed in wall/floor including cutting chesses and making good distrubed surface to match with existing surface . Note -1. 2 runs of 4 Sqmm sub main wire and one run of 4 sq mm for earthing and PVC Conduit with accesories shall be measured as one unit.
M&L In repair sub main wiring on wall/ceiling with 2 runs of 2.25 Sqmm single core PVC cable as per IS 694-1990(third revision) insulated unsheathed multistranded copper conductor FRLSH cable 1100 Volts grade drawn through in PVC cassing capping with all accessories such as Tees, elbows, junction box etc.as required of not less than 20 mm dia and 1 run of2.25 Sqmm single core PVC insulated unsheathed 1100 Volts grade, multistranded copper conductor FRLSH cable as earth continuity conductor and connecting to existing earth dolly with suitable size thimble and making good the disturbed surface to match with the existing including taking down of old sub main wiring ,all as specified and as directed Note : 3 runs of 2.25 Sqmm sub main wire and one run of PVC cassing and capping with accesories shall be measured as one unit.
M & L Taking down 1200/1400mm sweep ceiling fan, preparing the surfaces of ceiling fan by cleaning and filling the cavities with filler and applying one coat of synthetic enamel paint (Glossy finish) with spray gun, marking the MES No, fixing the fan in its original location, connecting up including provision of cable from ceiling rosse to connector to fan complete all as specified.
M & L Taking down 450/350/300mm sweep exhaust fan, preparing the surfaces of exhaust fan by cleaning and filling the cavities with filler and applying one coat of synthetic enamel paint (Glossy finish) with spray gun, marking the MES No, fixing the fan in its original location, connecting up including provision of cable from ceiling rosse to connector to fan complete all as specified.
Taking down unserviceable ceiling fan of 1200mm/1400mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No complete all as specified.
M & L Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c , 20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion completeall as specified. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
Supply & fix Regal Batten for LED tube lights, both side connection type and LED tube rod 1 x 20 Watt, both side connection all as specified and as directed. Make : Havells Cat Part No. REGALBATTENT8 upto 1x822W SSBSWH for Regal Batten & CRYSTAL 1213T8DSTL20W LED 8655 GLASS for tube rod or Surya/Wipro
Supply only heavy duty exhaust fans AC single phase 230/ 240 V of size 300 mm sweep all as specified and directed.
Supply only Wall mounted fans of size 300 mm sweep AC single phase 230 / 240 V all as specified and directed.
Taking down existing rusted cable trays except cables of any type or size and removing store yard for selling as scrap all as directed and specified.
Supply and Fixing of cable trays perforated pre-galvanised sheet of following sizes on walls parallel/perpendicular with necessary studs, nuts, bolts of galvanised steel of suitable length all as per site requirement:- 250 mm X 50mm X 1.6 mm (widtgh x Depth x Thick)
(b) 200 mm x 50 mm x 1.5 mm
(c) 150 mm x 50 mm x 1.5 mm
(d) 100 mm x 50 mm x 1.2 mm
(e) 80 mm x 25 mm x 1.1 mm
Supply and Fixing on walls/ on ceilings of casing capping with all accessories like joints, caps, corners, etc of following sizes:- (a) 100 mm
Supply and Fixing on walls/ ceilings of rigid PVC flexible conduit of the following sizes:- (a) 80 mm
Supply and Fixing of cable cap of size 25 mm complete all as specified and directed.
M&L in earthing complete with copper plate electrode 60 cm x 60cm x 3 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meters below normal ground level, connected to copper strip 20x3 mm upto length 7.5 mtr by means of bolts, nuts and washers of galvanised steel all as shown in electrical plate No. 3 connected to earthing test point complete all as specified and indicated including testing on completion including taking out old earthing complete. Note : The rate is deemed to be inclusive of the cost of complete earth work in any type of soil. PCC 1:3:6 type C-1 for chamber,RCC 1:2:4 type B1 for cover slab 50 mm thick, reinforcement 8 mm CTD bars @ 100 mm c/c both way, necessary form work, handle, charcoal dust 20mm dia GI med grade for watering and 40mm dia GI med grade earth lead protection pipes with funnel and wire mesh all complete all as specified and directed.
M&L earth continuity copper strip of size 20 x 3 mm complete all as specified and directed.
M&L air termination, single pointed, copper rod 12 mm dia and 300 mm long complete all as specified and directed.
M&L test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 Nos. 8 mm dia 25 mm long hex. Head screw complete all as specified and as directed including PVC junction boxes.
M&L GI tubing medium grade 40 mm dia with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Taking down existing copper strips of any type/ size along with junction boxes, lightening pointer etc. and keep in safe custody for re-using.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, sheet metal encl. with plug & socket etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L for point wiring 1.5 Sqmm PVC insulated unsheathed FRLSH multistandard single core copper conductor cable in PVC conduit rigid non metalic (ISI marked )/ in PVC casing capping or exsting concealed conduit fixed on wall / roof incl 1.5 Sqmm PVC insulated copper conductor as earth continuity wire are the following (a) One light Point control by one switch
(b) one fan point control by one switch and regulator.
(c,) One 5 pin Amps socket point control by one sitch on same board
(d) One 5 pin Amps socket point control by one sitch on independent board
All as per item No 99 above but with 2.5 Sqmm copper conductor including 2.5 Sqmm copper cable as earth wire for one 6 Pin 16 Amps Socket outlet on independent board.
S&F Socket 5 pin 5 Amps flush type complete all as specifeid and as directed.
S & F socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specifeid and as directed.
S&F Switch piano flush type single pole 1 way, 15 Amps complete all as specifeid and as directed.
S&F step type fan regulator electronic flush type complete all as specified and directed.
Taking down existing Tube light fitting/ Ceiling light ftting/ Building security light/ Flood light of any type and size and removing to store yard.
Supply & fix LED down lighter 2'x2' , 36/40 W 240 volt all as per specified and directed. Make Havells Cat Part No. ENDURASLIMPROPLUS 2x2 PLR36WLED 840MOD and driver LEDDRIVER36V36WS or Philips/ Crompton
Supply & fix Regal Batten for LED tube lights, both side connection type and LED tube rod 1 x 20 Watt, both side connection all as specified and as directed. Make : Havells Cat Part No. REGALBATTENT8 upto 1x22W SSBSWH for Regal Batten & CRYSTAL 1213T8DSTL20W LED 8655 GLASS for tube rod or Philips/ Crompton
S & F for LED Mirror light fitting 8 watt with connected accessories complete all as specified & directed. Make :Polycab Cat Part No. LD00103040 or to Philips/ Jaguar
Taking down ceilingfan/Exhaust fan, Painting of celing fans/Exhaust fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and hanging in original position and connecting up including provision of cable from ceiling rose or connector to fan.
S&F Sheet metal enclosure TPN for DB's when MCB's to be used 4 way with 200 amps bus bar double door
S&F MCCB 3 pole, 415 Volt fixed type 125 Amps with breaking capacity 16 KA complete all as specified and directed.
S&F MCB 'B' Curve 63 Amp Three pole, 415 Volts, Make L&T Cat Part No. BB30630B all as specified and directed.
S&F MCB 'B' Curve 63 Amp Three pole, 415 Volts, Make L&T Cat Part No. BB30630B all as specified and directed.
S&F MCB 'B' Curve SP 6 To 32 Amp , 240 Volts,Make Schneider Cat Part No. A9N1P06B to A9N1P40B, all as specified and directed.
S&F ceiling fans 1200 mm sweep at any location as directed and including suitable electrical connection and hanging arrangement also complete all as specified and directed. Make Usha cat part no. Technix Plus or Bajaj/Crompton
S&F 250mm sweep, PVC body exhaust fan heavy duty, single phase 230 Volts, all as specified & directed. Make: Havells Cat Part No. Ventil Air-DX white or Bajaj/ Crompton
M&L for earthing complete with galvanised steel earth plate elctrode 60 x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm as earthing lead by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.point 3 connected to earthing test point all as specified or indicated including testing on completion. including taking down old one (GI earth plate) galvanised steel all as show in elecrtical plate No 3 connected to earthing test point compleate all as specified and indicating testing on completion. The rate deemed to be inclusive of the cost of compleate earth work in any type of soil , PCC 1:3:6 type C1 for chamber RCC 1:2:4 slab of 50 mm thick reinforcement of 8 mm CTD bars @100 mm C/C both way neccessary form work , handle ,char coal dust, 20 mm dia GI pipe medium grade for watering and 40mm dia GI medium grade earth lead protection pipe wit funnel and wire mesh all compleate all as specified and directed.
Supply and fixing building security light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection of 30 Watt Crompton Cat Part No. LSTS-30-CDL/NL-M including suitable GI bracket of 25 mm dia and fixing arrangement on walls all as specified and directed including taking down of existing light fitting of any type and make.
S&F LED flood light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection, 3000 K, with 10 KV SPD of 50 watt of Crompton Cat Part No. LFL-50-CDL/60-M all as specified and directed including taking down of existing light fitting of any type and make.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft /loose soil complete all as specified and directed.
M&L for plain cement concrete in 1:2:4 type B1 using 20 mm graded stone aggregate for as in foundations, filling and mass concrete and Copings compleate all as specified and directed by Engr-In-Charge.
M&L for preparation of newly or previously untrated steel surfaces of any description over 10 cm grith or width and applying two caots of synthetic enamel paint over a coat of red oxide primer compleate all as specified and directed by Engr-In-Charge.
M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 compleate all as specified and directed by Engr-In-Charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings compleate all as specified and directed by Engr-In-Charge.
Dismantling Dismantling structural steel work in cluding doors, gates but excluding framed truss etc. compleate all as specified and directed by Engr-In-Charge.
M&L for plain cement concrete in 1:2:4 type B-2 using 420 mm graded stone aggregate for as in foundations, filling and mass concrete compleate all as specified and directed by Engr-In-Charge.
Fabrication , errection Rolled sections (Tublar Section) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates compleate all as specified and directed by Engr-In-Charge.
S& F structural steel work in Plates (plain or chequered) Plates (plain or chequered) Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment channels, square cut or notched (ordinary and counter sunk) forming holes, with with riveted, bolted or welded attachment confirming Fe-410-W(Gde E-250) quality B compleate all as specified and directed by Engr-In-Charge.
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth compleate all as specified and directed by Engr-In-Charge.
M&L for preparation of old steel surfaces of any description over 10 cm width or grith not other wise described applying two coats of anticorresive paint over a coat of epoxy primer compleate all as specified and directed by Engr-In-Charge.
M&L for preparation of new steel surfaces of any description over 10 cm width or grith not other wise described applying two coats of anticorresive paint over a coat of epoxy primer compleate all as specified and directed by Engr-In-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) compleate all as specified and directed by Engr-In-Charge.
S&F 180 mm dia of half round ready made evegutter of pressure rating 6 Kg/cm2 of approved make including necessary fittings like bend WC/MS clips etc compleate all as specified and directed by Engr-In-Charge.
Demoiltion of re in-forcment Concrete of any description and in any position not otherwise specifically provided for compleate all as specified and directed by Engr-In-Charge.
Dismantling structural steel work in cluding doors, gates but excluding framed truss etc compleate all as specified and directed by Engr-In-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft /loose soil compleate all as specified and directed by Engr-In-Charge.
Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter compleate all as specified and directed by Engr-In-Charge.
Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter compleate all as specified and directed by Engr-In-Charge.
M&L for providing Reinforement Concrete (nominal mix) of Type B1 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete compleate all as specified and directed by Engr-In-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point compleate all as specified and directed by Engr-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. compleate all as specified and directed by Engr-In-Charge.
Use and waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions compleate all as specified and directed by Engr-In-Charge.
M&L for providing Reinforement Concrete (nominal mix) of Type B1 20 mm graded stone aggregate as inColumns, pillars, piers, posts and struts compleate all as specified and directed by Engr-In-Charge.
S&F for Fe 410 -W(Gde E- 250) quality A Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) compleate all as specified and directed by Engr-In-Charge.
S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work, for portions framed and hung as gates, including pintle hinges, stops,hand-made sliding bolts, etc and for ornamental and intricate design conforming to Fe.290.Gde-E-165 compleate all as specified and directed by Engr-In-Charge.
M&L for plain cement concrete in 1:2:4 type B1 using 20 mm graded stone aggregate for as in foundations, filling and mass concrete and Ditto, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed compleate all as specified and directed by Engr-In-Charge.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders including cranking, bending spirally for hooping for columns, hooking ends and binding with andincluding mild steel wire (annealed) not less than 0.9mm dia or securing with clip all as specified and directed by Engr-In-Charge .
M&L for plain cement concrete in 1:2:4 type B0 using 12.5 mm graded stone aggregate for as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, levelling coarses of concrete in roof slab compleate all as specified and directed by Engr-In-Charge.
Sand filling under trenches for cushioning UG cable using crushed metal sand for protection of UG cable compleate all as specified and directed by Engr-In-Charge.
Supplying and laying reinforced precast concrete cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm compleate all as specified and directed by Engr-In-Charge.
Supply and laying 50 mm dia bore Tubes, 'medium grad',galvanised, with all fitting; laid in trenche compleate all as specified and directed by Engr-In-Charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core compleate all as specified and directed by Engr-In-Charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core compleate all as specified and directed by Engr-In-Charge.
Supply and laying sheet metal enclouser SPN for DB's when MCB's to be used 4 way with 200 Amps bus bar and single door compleate all as specified and directed by Engr-In-Charge.
S&F for MCB SPN 6 to 32 Amps , 230 Volts, C series with all incoming / out going connections with proper size of lugs compleate all as specified and directed by Engr-In-Charge.
S&F for MCB SPN 6 to 32 Amps , 230 Volts, 10 KA C series with all incoming / out going connections with proper size of lugs compleate all as specified and directed by Engr-In-Charge.
S&F for integral LED avaitaion light (Obstruction light ltd fitting) comprising of aluminium housing with polycorbanat encloisr withh all incoming / out going connections with proper size of lugs compleate all as specified and directed by Engr-In-Charge.
M&L for earthing complete with galvanised steel earth plate elctrode 60 x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised iron strip 32x6 mm by means of nuts, bolts, thrimbles, chuck nuts, washers of GI or steel including PCC (Concrete chamber ) shall be PCC 1:3:6 type C-1, using 20 mm graded aggregate, with fair face finished internal surface of concretye chamber shall be given 15 mm thick plaster in CM 1:4 , funnel with wire gauge of (0.68mm) 8 mesh per/liner inch, 80 mm thick RCC jali RCC pit cover 320 mm x 32mm of RCC 1:23:4 type B-1 using 20 mm graded stone aggregate reinforeced with XPM , Jalli annd cahrcole dust and common salt allas shwn in electrical plate No 3 of MES SSR 2009 Part -I (Specifications) and specified including provision of earth wire protected by 40 mm dia medium graded GI pipe, and including all excavation and earth work & connecting teh earth to an earthing test point / transformer nuetral/body/ LT panel etc. and tecting on compleation compleate all as specified and directed as Engr-In-Charge.
M&L for preparation of old steel surfaces of any description over 10 cm width or grith not other wise described applying two coats of anticorresive paint over a coat of epoxy primer at any height compleate all as specified including all neccessary scaffolding work upto 3m height & as directed by ingr - In - Charge.
S&F structural steel work in Stairs (framed) including stringers, treades, landing,balusters, hand rails etc. confirming Fe-410-W(Gde E-250) quality B compleate all as specified and directed by Engr-In-Charge.
S&F structural steel work in Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars,stiffeners, gusset plates, etc confirming Fe-410-W(Gde E-250) quality B compleate all as specified and directed by Engr-In-Charge.
S& F in structural steel work in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without anyattachment confirming Fe-410-W(Gde E-250) quality B compleate all as specified and directed by Engr-In-Charge.
Running welding in repairs compleate all as specified and directed by Engr-In-Charge.
Taking down old PVC stop valve, stop cock, from exsting position including all fittings compleate all as specified and directed by Engr-In-Chnarge.
S&F for CPVC globe or gate valve 25 mm dia iron wheel head screwed both ends for PVC compleate all as specified and directed by Engr-In-Chnarge.
S&F for 15 mm dia borte bib cock short body chromium plated with flange and aerator CP fancy type of 15 mm compleate all as specified and directed by Engr-In-Chnarge. Make :- CERA, JAQUAR, HINDWARE.
S&F of PVC connections 15 mm dia siz with PTMT nuts of length 450 mm and taking down exsting one compleate all as specified and directed by Engr-In-Chnarge.
S&F on wall / ceiling (concealed) CPVC pipe 25 mm dia SDR 11 & plan SDR fittings compleate all as specified and directed by Engr-In-Chnarge. Make :-Supreme
S&F on wall / ceiling (concealed) CPVC pipe 20 mm dia SDR 11 & plan SDR fittings compleate all as specified and directed by Engr-In-Chnarge. Make :-Supreme
takig down old unserviceable GI tubing of size 25 compleate all as specified and directed by Engr-In-Chnarge. Make :-Supreme
takig down old unserviceable GI tubing of size 20 compleate all as specified and directed by Engr-In-Chnarge. Make :-Supreme
THOMSONS CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .