Tender Value
₹46.7 L
EMD Value
₹1.4 L
Closing Date
29 Aug 2026, 6:00 pm2d left
DGM (E-E)
O/o Airport Director, AAI, Dehradun Airport
Modification of External and Internal Signages at Dehradun Airport
2026_AAI_286769_1
AAI/DDN/E-E/ENIT-07/26-27/
Open Tender
Electrical Works
Item Rate
120 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,180
₹1.4 L
6 Aug 2026
6 Aug 2026
31 Aug 2026
7 Aug 2026
29 Aug 2026
7 Aug 2026
7 Aug 2026 - 18 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Parking Tariff Schedule Signs - Pole Mounted
Providing and fixing Non-illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. All exterior signs should be manufatured considering harsh outdoor conditions, weather proofing techniques and materials shall be used.
1.Sign face - Double Sided, 2400mm x 1800mm, 3mm thick aluminium with a white retro-relective film. Graphics in Plotter RAL:5013 Exterior grade opaque vinyl pasted over white retro-relective vinyl.
2. Sign frame - M.S.frame 50x50x3mm hotdipped galvanised
3. Sign structure - MS square post 125x125x5mm and mounting square sections 75x75x3mm, hotdipped galvanised and PU Painted to match RAL 9006 grouted in ground. Secret ixing methods should be used to fix parts together.
4. Base plate - 300x300x10mm thick plate mounted on the flooring.
Providing and laying foundation for the sign including its compaction and all activities like Excavation, PCC base layer, providing and fixing in position electrical connection wherever applicable and finished as per drawing. The item cost includes cutting and opening the floor finish at location, and making good the location to the match the original finish after fixing and installation of sign.
The actual structural design of the sign for its stability shall be responsibility of the EPC contractor and shall be designed with due consultation and approval from structural designer.
Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
(Note: Ground Clearance of the sign face shall be 2400mm) | 4 | Nos. | - | - |
| 2 | Parking Instructions Signs
Providing and fixing Non-illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. All exterior signs should be manufatured considering harsh outdoor conditions, weatherproofing techniques and materials shall be used.
1. Sign Face: Double Sided, 900mm x 1200mm, 3mm thick aluminium with a white retro-relective film. Graphics in Plotter RAL:5013 Exterior grade opaque vinyl pasted over white retro-relective vinyl.
2. Sign frame - M.S. box section 25x25x2mm, hotdipped galvanised.
3. Sign Structure: MS square post 75x75x3mm thick hotdipped galvanised and P.U. painted to match RAL 9006 grouted in ground. The actual structural design of the sign for its stability shall be responsibility of the EP Ccontactor. Secret fixing methods should be used to fix parts together.
4. Foundation: Providing and laying foundation for the sign including its compaction and all activities like Excavation, PCC base layer, providing and fixing in position finished as per drawing. The item cost includes cutting and opening the floor finish at location, and making good the location to the match the original finish after fixing and installation of sign.
Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. (Sign Size as per TATA Elxsi standards)
(Note: Ground Clearance of the sign face shall be 2400mm) | 12 | Nos. | - | - |
| 3 | Airline Listing & Lane Information Sign - Pole Mounted Sign type 1.5a
Refer design drawing 1.5a-G (On common frame & structure)
Providing and fixing Non-illuminated Airline Listing & Lane Information Sign, to be designed on common frame mounted on common structure, for three departure Gates i.e. D1, D2 & D3 and Lane Information signs, in 04 (four) vertical section arrangement. Each vertical section coresponding to the departure gates shall have provision of indicating 04 (four) airlines per departure gate. The sign face of fourth vertical column i.e. Lane Information, shall have same width and height as that of departure gates sections. Ground clearance of the signage shall be 2800 mm. The job work includes all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. All exterior signs should be manufatured considering harsh outdoor conditions, weather proofing techniques and materials shall be used.
1.Sign face - 3mm thick aluminium with a white retro-relective film. Graphics in Plotter RAL:5013 Exterior grade opaque vinyl pasted over white retro-relective vinyl.
2. Sign frame - M.S. box section 50x50x3mm, hotdipped galvanised to be fixed upon the sign structure.
3. Sign structure - MS hollow box section 125x125x5mm and mounting square sections 75x75x3mm, hotdipped galvanised and PU Painted to match RAL 9006 grouted in ground. Secret fixing methods should be used to fix parts together.
4. Base plate - 300x300x10mm thick plate mounted on the flooring.
Providing and laying foundation for the sign including its compaction and all activities like Excavation, PCC base layer, providing and fixing in position electrical connection wherever applicable and finished as per drawing. The item cost includes cutting and opening the floor finish at location, and making good the location to the match the original finish after fixing and installation of sign.
The actual structural design of the sign for its stability shall be responsibility of the EPC contractor and shall be designed with due consultation and approval from structural designer.
Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
(Note: Ground Clearance of the sign face shall be 1200mm) | 1 | No. | - | - |
| 4 | Airline Listing Announcer - Type 1.5b-G
Refer design drawing 1.5b-S
Providing and fixing Illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. All exterior signs should be manufatured considering harsh outdoor conditions, weatherproofing techniques and materials shall be used.
1. Sign Box - Lasercut Bent Fabricated in clear acrylic 8mm thickwith Pentone YellowC vinyl pasted on it with backlighting.
2. Sign Face - 3mm thick aluminium fabrication hotdipped galvanized mounted on the sign structure with black colour RAL 9011 with a provision of through and through laser cutting for airline branding panel.
Airline Branding Panel - Printed media vinyl pasted on 8mm thick 040 White translucent acrylic with a backlit provision.
3. Sign structure - M.S. hollow box section 50x50x3mm, hotdipped galvanised and PU Painted to match RAL 9006 grouted in ground.
4. Crash Guard - Protection for sign from trollies, wheeled baggage in stainless steel pipe fixed with ss palte bracket.
Providing and laying foundation for the sign including its compaction and all activities like Excavation, PCC base layer, providing and fixing in position electrical connection wherever applicable and finished as per drawing. The item cost includes cutting and opening the floor finish at location, and making good the location to the match the original finish after fixing and installation of sign.
The actual structural design of the sign for its stability shall be responsibility of the EPC contractor and shall be designed with due consultation and approval from structural designer. All hardware used for ixing of sign shall be Stainless steel. Secret fixing methods should be used to fix parts together.
Lighting: All internal illumination shall be using power LED Lights of approved make with electronic controllers, having even spread and overlaps to avoid banding and dark spots. Cost to include all internal connections and Wiring, terminating and connecting the incoming cable laid by Airport contractor at the site.
Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing.
(Note: Signs placed on internal roads and landscape of Airport to align and manage pedestrian movement.) | 3 | Nos. | - | - |
| 5 | Traffic Statutory Sign
Sign Type 1.4a
Refer design drawing 1.4a
Providing and fixing Non-illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. All exterior signs should be manufatured considering harsh outdoor conditions, weatherproofing techniques and materials shall be used.
Sign Face:
Providing and fixing sign face panels 3 mm thick Aluminium sheet fixed to sign structure. White retro-reflective vinyl pasted over edge to edge aluminium sheet. Graphics in plotter cut red Pantone 485C and black Pantone 6C exterior grade opaque vinyl pasted over white retroreflective vinyl.
Sign Structure:
MS square post 50x50x3mm thick hotdipped galvanised and P.U. painted to match RAL 9006 grouted in ground. The actual structural design of the sign for its stability shall be responsibility of the EP Ccontactor. Secret fixing methods should be used to fix parts together.
Foundation:
Providing and laying foundation for the sign including its compaction and all activities like Excavation, PCC base layer, RCC, providing and fixing in position finished as per drawing. The item cost includes cutting and opening the floor finish at location, and making good the location to the match the original finish after fixing and installation of sign.
Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. (Sign Size as per TATA Elxsi standards) | 2 | No. | - | - |
| 6 | Boarding Gate Announcers -Ceiling suspended (Four Sided)
Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.
Sign Box: Providing and fixing sign box of size 600mm x 600mm with lasercut Bent Fabrication in 5mm thick clear acrylic with pantone yellowC Vinyl pasted over acrylic with white diffuser film on inside face. Blockout vinyl for text Pantone Black 6C. Complete box excluding bottom side is lited with internal LED lighting. Acrylic fabrication shall have transparent structural supports for obstruction free lighting. Box to be directly mounted on the sign structure.
Bottom panel: Bottom MS Panel powder coated in colour to match Vinyl Black of Pantone Black 6C.
Suspender: Providing and fixing Stainless steel Hollow section 50mm OD mounted on slabs/beams/
walls.The actual structural design of the sign for its stability shall be responsibility of the EP Ccontactor.
All hardware used for fixing of sign shall be Stainless steel. Secret fixing methods should be used to fix parts together.
Lighting: All internal illumination shall be using Power LED Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots.Cost to include all internal connections and Wiring, terminating and connecting the incoming cable laid by Airport contractor at the site.
Accessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawing. | 4 | No. | - | - |
| 7 | Providing and fixing Illuminated Outdoor type Pylon signage of Size 1600mm x 1000mm x 175mm including all operations from fabrication to installation all complete as per technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge. All exterior signs should be manufatured considering harsh outdoor conditions, weather proofing techniques and materials shall be used. | 3 | Nos. | - | - |
| 8 | Providing and replacing vinyl film of existing illuminated cubical box (Four Sided) type signages of size 600mm x 600 mm., including all operations from peeling-off existing sign films, cleaning the surface, applying new plotter cut Pantone Yellow C vinyl for background and Block out vinyl for text Pantone Black 6C as per technical specifications, signage schedule etc., applying two coats of PU Paint of similar colour/ shade on MS sign structure & base plate, after duly scrubbing/ cleaning the surface and installing the so modified signage by duly grouting the base plate on desired location, making electrical connection etc. to the satisfaction of the Engineer-in-Charge. | 7 | Nos | - | - |
| 9 | Providing Exterior grade Plotter cut Blockout vinyl on existing wall/ ACP cladding/ glass. The jobwork include cleaning/ preparing the surface and properly pasting new vinyl signages in an approved manner. The Plotter cut blockout vinyl shall be as prescibed for background and text as per graphics, as per site requirement and as directed by Engineer-In-Charge. The vinyl shall be of specified make duly approved by the Engineer-in- Charge. | 65 | Sq. Mtr. | - | - |
| 10 | Providing digitally printed vinyl graphics on ACP/ glass/ wall/ other surfaces. The jobwork include cleaning/ preparing the surface and neatly pasting new vinyl creative in an approved manner with text and graphics as per site requirement and as directed by Engineer-In-Charge. The vinyl shall be of specified make duly approved by the Engineer-in- Charge. | 20 | Sq. Mtr. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
TenderDocument.pdf
Tender Documents • 15.16 MB
BOQ_334703.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].