Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹39.0 L+₹1.6 L (4.19%)Rejected-Finance | L2 | Rejected-Finance BecomeL2 | |
| 3 | L3₹40.9 L+₹3.5 L (9.29%)Rejected-Finance H NO 18 BY LANE NO 09 SATGAON PRAGATI NAGAR GUWAHATI ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L3 | Rejected-Finance BecomeL3 | |
| 4 | L4₹43.0 L+₹5.6 L (15.0%)Rejected-Finance | L4 | Rejected-Finance BecomeL4 | |
| 5 | L5₹44.1 L+₹6.7 L (18.0%)Rejected-Finance | L5 | Rejected-Finance BecomeL5 |
Tender Value
₹46.1 L
EMD Value
₹92,300
Closing Date
7 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Tezpur
GE South Tezpur, Mission Charlia
SPL REPAIRS TO BLDG NOS T-42 T-43 AND T-52 SINGLE OFFRS ACCN AT 155 BH UNDER GE SOUTH TEZPUR
2023_MES_579598_1
8718
Open Tender
Civil Works
Item Rate
180 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹92,300
Yes
8 Apr 2023
7 Feb 2023
10 Mar 2023
7 Feb 2023
7 Mar 2023
21 Feb 2023
8 Feb 2023 - 27 Feb 2023
Amount
Taking down chowkats or frames not exc 1.5sqm each with shutters( without taking off shutters from the frame ) including dismantling of PCC bed blocks for hold fasts.complete all as specified and as directed.
Taking down chowkats or frames exc 1.5sqm and not exc 4.0 sqm each with shutters ( without taking off shutters from the frame ) including dismantling of PCC bed blocks for hold fasts.complete all as specified and as directed.
Refixing of shutters of any description exc 1.00 Sqm and n.exc 2.00 sqm each in same opening including of taking down, easing, adjusting and renewal/refixing of builders hardware as required including renewal of unserviceable screws, etc.complete all as specified and as directed.
Refixing of shutters of any description n. exc 1.00 Sqm each in same opening including of taking down, easing, adjusting and refixing/renewal of builders hardware as required including renewal of unserviceable screws, etc.complete all as specified and as directed.
S&F 2nd class hard wood plain, solid, striaght in chowkats and framed rebated on the solid rounded or chamfered put together with glue pinned at joints including making rebate for fixing second shutter as per site requirement.complete all as specified and as directed.
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides.complete all as specified and as directed.
Supply and fix 30mm thick second class hard wood glazed and skeleton, open rebated and prepared to receive glass/ wire cloth, gauze exc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. The sizes of members of shutters as per IS-1003 (Part-2), kiln seasonable and chemically pressure treated and fitted to chowkhats complete all as specified and directed. (Note : Glass / wire cloth wil be measured and paid separately).complete all as specified and as directed.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.complete all as specified and as directed.
S&F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.complete all as specified and as directed.
S&F factory made solid PVC door frame of size 50mm x 47 mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube.complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC stiles and plain colour PVC sheets for top rail, lock rail bottom rail on either side & as gap insert for top rail & bottom rail panneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stile & rails with suitable PVC sheet beading & jointed together with solvent cement all as specified and shown on drawing.complete all as specified and as directed.
S&F 100mm size type B-21 Butt hinges extruded aluminium alloy with galvanised MS sheet hinges pin anodised.complete all as specified and as directed.
S&F 75mm size type C-21 Butt hinges extruded aluminium alloy with galvanised MS sheet hinges pin anodised.complete all as specified and as directed.
S&F extruded aluminium alloy handels fabricated type, anodised, 150mm long.complete all as specified and as directed.
S&F extruded aluminium alloy handels fabricated type, anodised, 100mm long.complete all as specified and as directed.
S&F Aluminium anodised sliding door bolts of size 300mm long, with hasp & staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extreded sections or cast aluminium alloy.complete all as specified and as directed.
S&F Aluminium anodised barrel tower bolts of extruded section 200 mm long and fixed with screws.complete all as specified and as directed.
S&F Aluminium anodised barrel tower bolts of extruded section 150 mm long and fixed with screws.complete all as specified and as directed.
S&F MS 300mm ordinary rat tail rod pattern spring including roller and roller plate.complete all as specified and as directed.
Supply & Fix in repairs floor door stopper of brass body and tongues with hard drawn steel spring, overall length cover plate 150mm complete all as specified and directed
S&F standard aluminium powder coated section (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE) frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc complete shall as specified etc complete all as specified and as directed
S&F Anodised aluminium window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws,4mm plain glass/frosted glass and stainless steel wirmesh 0.36mm nominal dia of wire and average width of aperture 1.40mm etc.cComplete all as specified and as directed.
Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors, ladder, framed balusters, railing, frame work for water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
Dismantling Structural steel work includings door, gates, etc and similar works complete all as directed
S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W (Gde 250 quality A) complete all as specified and directed.
Dismantling asbestos cement corrugated semi corrugated etc sheets in roof covering.complete all as specified and as directed.
S&F 0.5mm thick pre-painted galvalume aluminium zinc coating GI based trapezoidal steel sheet of any colour ,tensile strength of 550Mpa as in roof covering ,cladding to wall ,ridge,gutter etc fixed with self tapping screws.complete all as specified and as directed.
All as per item No.27 above but plain sheet for ridge ,gutter etc fixed with self tapping screws as specified.
Dismanting timber scantling 40 Sqcm and over in secion in any position in framed work.complete all as specified and as directed.
M&L 2nd class HW in scantling fixed clean swan in framed work.complete all as specified and as directed.
Dismanting timber boarding of any description fixed in any position.complete all as specified and as directed.
M&L second class hardwood Weather boarding, 20mm thick, wrought both sides and edges shot and chamfered.complete all as specified and as directed.
Demolition of brick work built in cement mortar including pillar etc below/ above ground level etc and removing to a distance not exc 50 meter. Complete all as specified and as directed.
Demolition of reed lathing, single or double including battens and plasters or checken wire lathing.complete all as specified and as directed.
M&L Brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6.complete all as specified and as directed.
Material and labour for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar ( 1:6) all as specified and directed.
M&L 15 mm thick rendering in CM (1:4) on one side of lathing finished even and smooth without using extra cement including 0.71mm chicken wire and size of mesh 12mm.complete all as specified and as directed.
M&L 10 mm thick rendering in CM (1:6) on other side of lathing finished even and smooth without using extra cement.complete all as specified and as directed.
M&L 10mm thick rendering in cm (1:6) on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement.complete all as specified and as directed.
Supply only water proofing compound. Conforming to IS -2645.complete all as specified and as directed.
M&L preparation of newely plaster surfaces and appplying two coats of Acrylic exterior emulsion (Anti fungal) over one primer coats of primer over one coat of putty by smart painting method to new plastered walls as per manufacturer and apllied by approved applicator complete all as specified and directed.
M&L complete removal of old plaseter sufaces and appplying two coats of Acrylic exterior emulsion (Anti fungal) over one coat of primer to wall/chajja of external surface as per manufacturer instruction and apllied by approved applicator complete all as specified and directed.
M&L Applying two coats of Oil bound distemper by smart painting method to newly plastered/previously untreated wall over a coat of 1 mm layer wall care putty over a coat of primer including preparation of newly plastered wall all as specefied and directed.
M&L complete removal of old plaseter sufaces and appplying two coats of Oil bound distemper by smart painting method to old/previously untreated wall over a coat of 1 mm layer wall care putty over a coat of primer complete all as specefied and directed.
Material and labour for preparation of new and previously un-treated wood and wood base surfaces of any description, not otherwise described over 10cmwidth or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed.
M&L prepration of new steel surface and applying two coats of synthetic enamel paint over one coats of red oxide preparation of new surfaces over 10 cm width on ginth.complete all as specified and as directed.
M&L for applying for preparation of old painted surfaces of wood and woodbase surfaces of any description , not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint all as specefied and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as directed.
S&F false ceiling with powder coated exposed G.I. grid suspension system Everest E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner (3600 mm long, 0.25 mm thick, 38mm height) Cross Tee (1200mm/600mm long, 0.25 mm thick, 27 mm height) and Wall Angle (3000 mm long, 0.4 mm thick, 22 mm height). The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. The Main Runners to be placed @ 1200mm, The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 6 mm dia G.I. wire from purlins/soffit. 4 mm thick High Pressure Steam Cured Everest Non Asbestos Fibre Cement Designer Ceiling Board or equivalent quality having Density>1200 Kg/m3, size 595mm x 595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7&8, should be placed in the Grid module to form a False Ceiling.complete all as specified and as directed.
S& F in repairs of 8mm thick prelaminated board in false in any type of frame work all as sepcified and drected
S&F of pre-laminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work thickness of 12 mm complete all as specified and directed.
Material & Labour 19/20 mm thick Block boards, grade 2 quality, interior grade, laminated sheet with decorative face, veneer on one face, commercial type fixed with screws to timber frame work complete all as specified and directed.
S & F Continuous (piano) hinges, 30 mm width of flaps ,mild steel, bright finish or electrogalvanised complete all as specified and directed.
S&F bal catches with 8 mm dia steel ball magnet catches for cuboard shutter including strking plate as approved etc complete all as specified and as directed
S&F100 mm Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
Supply & fix as in repair curtain harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. with two Nos of socket ,end caps and brakets (decorative type) complete for doors/window opening all as specified and directed
Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site complete all as specified and directed.
All as per item No 57 here in before but 20 mm bore.
S&F of 15 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor complete all as specified and directed,
All as per item No 59 here in before but 20 mm bore.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories).complete all as specified and as directed.
Supply and fix, 110mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls/floor all as specified and directed.
S&F in repairs PVC (SWR) 110mm dia bends any radius all as specified and directed.
Supply and fix, PVC cowls 110 mm bore all as specified and directed.
Supply and fix, 75 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls/floor all as specified and directed.
S&F in repairs PVC (SWR) 75 mm dia bends any radius all as specified and directed.
Supply and fix, PVC cowls 75 mm bore all as specified and directed.
S&F Stack clamps including bolts and nuts and securing ends of stays to wall or roof for 100/75mm bore complete all as specified and directed.
S&F in repairs center hole basin mixer without pop-up waste system complete all as specified and directed.
Supply and fix, as in repairs, sheet glass self assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with cromium plated bracket guard and railing 60cm long all as specified and directed.
Supply and fix as in repairs, sheet glass self assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with cromium plated bracket guard and railing 60cm long all as specified and directed.
S&F in repair brass choromium plated towel rail 600 mm long complete all as specified and directed.
S & F in repairs Toilet paper holder of brass chromium plated fixed to walls with chromium plated(CP) brass screws.complete all as specified and as directed.
S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F in repair 15mm bore dia brass choromium plated wall mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repair Towel Ring of CP fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed.
Supply and fix, as in repair, vitreous china wash basin, white, flat back size 580 x 450 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified and directed.
Supply and fix,as in repair, waste coupling CP 32 mm dia for glazed ware basins etc with fly nuts flanged etc complete all as specified and directed.
Supply and fix,as in repair, 32 mm dia PTMT 610 mm long waste pipe suitable for WHB complete all as specified and directed.
Supply and fix,as in repair, CP 40mm dia waste coupling with inlet and out let screwed for pipe or connections including packing, union and cap etc complete all as specified and directed.
Supply and fix,as in repair, 40 mm dia PVC 610 mm long waste pipe suitable for complete all as specified and directed.
S&F in repairs grating 100mm dia of PTMT (minimum weight 25 gms) all as specified and directed.
Supply and fix, as in repair, Overhead Shower 100 mm dia Round Shape Single Flow (Brass Chromium Plated) with Rubit Cleaning Syste, including fixing to steel pipe or union of 15mm bore all as specified and direcetd.
Supply and fix, as in repairs, Hand Shower (Health Faucet) (Brass chromium plated) with 1 Meter Long Easy Flex Tube in Chrome Finish & Wall Hook complete all as specified and as directed.
Supply and fix, as in repair, 10 ltrs capacity PVC valve less syphonic action type, low level flushing cistern, white, with inlet, ball valve float and handle including brackets & flush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specified and directed.
Supply and fix, as in repair,15 mm dia 600 mm long connection pipe with two PVC PTMT nuts at each ends with rubber washer complete all as specified and directed.
S&F 20mm Ball PTMT valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed.
S&F kitchen plate rack made out of stainless steel 0.63 mm thick sheet with partitions and size of rack 800 x 250 x 900 mm with shape and pattern as per sample kept in Sample room of GE Office complete all as specified and directed. Nirali /Anjali/Prayag/Bluestar
S&F in repairs angle cock 15mm bore, two way, chromium plated, fixed to GI or steel tubing incl fittings complete all as specified and directed. Make - Jaguar Model No ALI-85053 Angular Stop Cock with Wall Flange
Supply and fix, 15 mm bore bib taps, cast copper alloy,cromium plated, fancy type, with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and directed.
Supply and fix sinks with drainage board made out of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortor to dwarf wall or including fixing cantiriver lever brackets and connecting union to pipe overall size 915mmX460mm and bowl size 410mmX330mmX160mm all as specified and directed.Make - Nirali /Anjali/Prayag (All ISI marked).
Demolition of reinforced cement conc of any description and in any position.complete all as specified and as directed.
M&L Reinforced cement concrete Type A1(1:1-1/2:3) (20mm graded aggregate) as in shelves, slab and the like.complete all as specified and as directed.
S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.complete all as specified and as directed.
Use & Waste of Formwork to sides and soffits of floor or roof beam , beam haunching, girders ,lintels shevles inclusidng support and hangs
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick above or below ground level all as directed.
M&L 75 mm thick PCC 1: 3:6 type C2 using 20mm graded agg finishing even and smooth without using extra cement as in plinth protections/path and laid fair in alternate bays n including filler joints with sealing compound grade 'A' complete all as specifed and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing) complete and removing rubbish off the premises complete all as specified and directed.
M&L for Chequered cement concrete tiles of size 200 x 200 x 25 mm thick with grey cement and pigment, set and jointed and pointed in neat cement slurry in floors laid over & including 15 mm thick screed bed in cement mortar 1:6 all as specified and as directed.
M/L Granite (of any type) tiles 18-20 mm thick machine cut (table rubbed and polished), bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 15mm thick screed bed in CM 1:6 over cooking platform including grinding the edges half round and polishing including etc complete all as specified and directed.
M&L 18-20 mm thick Granite (of any type) tiles machine cut (table rubbed and polished), in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 10mm thick screed bed in CM 1:4 including grinding the edges half round and polishing including etc complete all as specified and directed.
M&L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) light shade, polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6.complete all as specified and as directed.
All as per item No 103 above but in skirting over 10mm thick screeding in cement mortar 1:4.complete all as specified and as directed.
S&F Coloured Glazed ceramic tiles 450 x 300 mm x 6 to 7mm thick, in skirting /dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete including rendering 10 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface as backing coat coat of dado/skirting etc complete all as specified and as directed
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 for laying floor finishes.complete all as specified and as directed.
Taking down carefully unserviceable point wiring (light,fans,socket etc) complete incl battens and fittings such as switch, ceiling rose,light fittings, regulatos, socket etc and making good disturbed surface of wall/floor etc complete all as specified.
M & L for point wiring for one light /fan point with 1.5 sqmm cable PVC insulated copper conductor multi stranded as per IS-694 FRLS cable controlled by one way switch, drawn through PVC casing capping with all accessories incl PVC sunken boxes of approved size for fixing switches, sockets etc and 1.5 sqmm multi strand copper conductor cable (green colour) PVC insulated and unsheathed for earth continuity complete all as specified and directed.
All as per item No. 108 above but for one fan/Exhaust fan point
All as per item No. 108 above but for 5 amps socket on same board
All as per Ser item No.108 above but for 5 amps socket on independent board.
All as per Ser item No.108 above but with 2.5 sqmm cables for 15 amps switch socket combination outlet on independent board complete all as specified and directed.
All as per Ser item No.108 above but for one bell point controlled by one, one 5 amp switch
S&F modular switch flush type, 6 Amp. SP, one way ,1 module.complete all as specified and as directed.
S&F modular switch, 16 Amp flush type 1 module.complete all as specified and as directed.
S&F in repair modular socket outlet, 3 pin, 6 Amp, flush type 2 module.complete all as specified and as directed.
S&F in repair modular socket outlet, 3 pin, 16 Amp flush type 2 module.complete all as specified and as directed.
S&F in repair modular bell push, flush type, 5 Amp,1 module.complete all as specified and as directed.
S&F Ceiling rose 3 phase, PVC/ Polycarbonate body.complete all as specified and as directed.
S & F electronic fan regulator,100W ,230V ,50Hz stepped socket type for ceiling fan complete all as specified . Make- Anchor/Leader/Standard
Supply and Fix wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution 20W,6500k, 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting. Make Havells,Cat No-LHEXAWP7IN1W020 or equivalent make of Philips/CG/Orient/Surya
S& F in repair exhaust fan of sweep 200/250 mm PVC Body including taking down existing old unseviceable Exhaust fan and taking to MES Store as specified and directed. Make- Crompton cat No 225 Transair (Double bearing) or equivalent make of /Havells/Bajaj/Usha
S & F Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete and all disturbed surfaces of wall shall be made good to match the existing wall finishes all as specified and directed by Engineer-in-charge. make- L&T/Havells/C&S/legrand/hager.
S & F MCB DP 6 to 32 Amps, B series, 230 Volts complete all as specified and directed . Make - Standard/Havells/C&S
S & F MCB SP 6 to 32 Amp, B series , 230 Volts complete all as specified and directed . Make - L&T/Havells/C&S/legrand/hager.
Dismantaling of Geyser of any capacity including its all accessories and refixing it at same position after all work including fixing of new hot and cold connection pipes.complete all as specified and as directed.
Dismantaling of fan of any size including its all accessories and refixing it at same position after all work.complete all as specified and as directed.
M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth wire of dia 4mm as earthing conductor and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge. Note: 1.The above quoted rate shall include cost of main earthing lead wire of 4 mm dia, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GI water pipe including GI protection pipe 40mm dia light grade for earth strip etc. 2. The cost of earth pit is deemed to be included in the unit rate. 3. The cost of taking down old unsv earthing with all its accessories is deemed to be included in the unit price.
S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq mm 2 core including taking down old unsv cable complete all as specified and directed.
Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m depth for foundation and getting out in soft/lose soil.for foundation etc..complete all as specified and as directed.
Returning, filling incl spreading levelling watering and well ramming in layers not exc 25 cm for soft/lose soil. complete all as specified and as directed.
Removing excavated material n exc.50 m and depositing where directed at a level n exc 1.5 m above the starting point.complete all as specified and as directed.
M&L for Sand cushion with clean dry sand for protection of under ground cable.Note : Punned thickness of sand layer shall be measured and paid.complete all as specified and as directed.
M&L for Brick Sub Class 'B' locally available best quality laid in trenches with width equal to length of the bricks, above sand cushioning for cable protection complete all as specified and as directed.
Supply, lay and fix 25 mm bore galvanized iron water tubing low grade including all fittings and fixed/ laid in trenches or on poles complete all as specified and directed. Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies and loyaty charges as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
Chinmay Traders
SHANKAR ENTERPRISE
THE BUILDERS
M/S CHUNILAL SHOME
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .