RE WIRING REPAIR REPLACEMENT AND MAINT OF EM FITTINGS AND FIXTURES IN CERTAIN OTM ACCN UNDER THE AREA OF AGE BR I IN ARMY AREA JODHPUR (8940/E8)
2020_MES_341662_1
GE/J/A- of 2020-2021 (8940/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (A) Central Multan Line Army Area Jodhpur
1.Scanned copy of Application and DD Banker Cheque as cost of tender and copy of EMD for unenlisted contractor 2.Copy of GST Registration Number 3.Copy of enlistment letter 4.For unenlisted contractor details of documents meeting enlistment criteria
5 documents required · 5 mandatory
₹500
GE (A) Central Jodhpur
₹30,000
Yes
21 Dec 2020
29 Apr 2020
29 May 2020
29 Apr 2020
27 May 2020
13 May 2020
Amount
Taking down copper/aluminium point wiring surface/ concealed (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell etc. removing materials from site of work complete or removing materials to store for keeping in safe custody and making good disturbed surfaces of walls, floors, etc.
M&L for point wiring complete with using 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked( Make: Havells, RR kable,KEI/ Finolex ) passing in and including PVC conduit fixed on PVC saddle and clamp (ISI Marked) with accessories fixed on surface of wall / roof / ceiling etc in sunken pressed steel terminal boxes in wall,including 3.00 mm thick plastic laminated hylem sheet and 1.50 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) cable for common earth and connecting to earth dolly material and labour for One light point controlled by one, one way switch.
All as per item No 02 above but One fan point controlled by one way switch.
All as per item No 02 above but One socket outlet 3 pin 5/6 Amps on same board
All as per item No 02 above but One socket outlet 3 pin 5/6 Amp on independent board
All as per item No 2 above but with using 2.5 Sq mm single core multistanded copper conductor cable and 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board .
M&L for point wiring complete with using 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked ( Make: Havells, RR kable,KEI/ Finolex ) passing in existing conduit & existing in sunken pressed steel terminal boxes in wall,including 3.00 mm thick plastic laminated hylem sheet and 1.50 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) cable for common earth and connecting to earth dolly material and labour for One light point controlled by one, one way switch
All as per item No 7 above but One fan point controlled by one way switch.
All as per item No 7 above but One socket outlet 3 pin 5/6 Amps on same board
All as per item No 7 above but One socket outlet 3 pin 5/6 Amp on independent board
All as per item No 7 above but with using 2.5 Sq mm single core multistanded copper conductor cable and 2.50 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board .
M&L for Point wiring complete with 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ( Make: Havells, RR kable,KEI/ Finolex) ( ISI Marked) passing in PVC cassing-N-capping 25/32 mm dia fixed on surface of wall/roof/ceiling with existing/new sunken pressed steel terminal boxes including 3.00 mm thick plastic laminated sheet top cover and 1.50 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) cable for common earth and connecting to earth dolly material and labour for One light point controlled by one, one way switch
All as per item No 12 above but One fan point controlled by one way switch.
All as per item No 12 above but One socket outlet 3 pin 5/6 Amps on same board
All as per item No 12 above but One socket outlet 3 pin 5/6 Amp on independent board
All as per item No 12 above but with using 2.5 Sq mm single core multistanded copper conductor cable including 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board .
M&L for concealed Point wiring complete with 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked , class V ( Make: Havells, RR kable,KEI/ Finolex ) in concealed PVC conduit (ISI Marked) not less than 20 mm dia heavy duty with accessories etc and including sunken pressed steel terminal boxes in wall, including 1.50 sq mm PVC insulated unsheathed stranded copper conductor (FRLS) cable for common earth and connecting to earth dolly material and labour for One light point controlled by one-one way switch (Note- rates of chasing/cutting & making goods shall be included in the unit rate) .
All as per item No 17 above but One ceiling fan/Exhaust fan point controlled by one, one way switch through Regulator.
All as per item No 17 above but One three pin 5/6 Amp socket on same board with other switches.
All as per item No 17 above but One three pin 5/6 Amp socket on independent board.
All as per item No. 17 above but with 2.5 Sq.mm. (nominal area) cable for one 3 Pin 16 amp socket on independent board including one 1.5 sqmm copper conductor multi stranded green colour PVC insulated unsheathed cable 1100 volts grade as earth wire upto common earth & connected to earth dolly complete all as specified and directed by Eng.-in-charge.
S&F switch piano flush type single pole one way 6 Amp ISI Marked. Make: Havells/ABB/legrand
S&F switch piano flush type single pole one way 16 Amp ISI Marked .Make: Havells/ABB/legrand
S&F socket outlet 2 in 1, 5 pin, 6 Amp flush type ISI Marked. Make: Havells/ABB/legrand
S&F socket outlet 2 in 1, 6 pin, 6 and 16 amp flush type ISI Marked. Make: Havells/ABB/legrand
M & L for Ceiling rose, 3 terminal/PVC/ polycarbonate, isolated body. Make: Havells/ABB/legrand
M & L for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting. MMake: Havells/ABB/legrand
Supply and fix socket type(2 Module) electonic fan regulator flush type ISI Marked.Make: Havells/ABB/legrand
S&F sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-42 DB's suitable for one MCB SPN as incoming and 2 MCB SP as out going,SPN 4Way complete all as specified and directed by Engr-in-charge. Make :-Havells/Legrand/ABB
S&F sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 6 MCB SP as out going SPN 8 way complete all as specified and directed by Engr-in-charge. Make :-Havells/Legrand/ABB
S&F sheet metal enclosures 415 volt TPN 4 way with 200 Amp rated bus bar, double door IP-43 DB's suitable for With one No 100 Amp 10 KA TPN MCCB as incoming complete all as specified and directed by Engr-in-charge. Make :-Havells/Legrand/ ABB
Supply and Fix MCB Single pole"C" series 5-32 Amps ISI marked.Make :-Havells/Legrand/ABB
Supply and Fix MCB Single pole & neutral "C" series 40 Amps ISI marked.Make :-Havells/Legrand/ Indo Asian
Supply and Fix MCB Single pole & neutral "C" series 63. Amps ISI marked.Make :-Havells/Legrand/ Indo Asian
M&L in repairs sub main wiring with 2x6 Sq mm single core multistrandred copper conductor PVC insulated and unsheathed cable passing through PVC Cassing-N-Capping of size 25/32mm ISI marked (MMS) fixed on surface of wall/ceiling and making good the distrurbed surface of wall incl 6 Sq mm single core copper conductor cable PVC insulated and unsheathed cable as earth wire. Note :- Two runs of cable 6 Sqmm and One run of 6 Sqmm earth wire shall be measured as unit length.
M&L in repairs sub main wiring with 2x6 Sq mm single core multistrandred copper conductor PVC insulated and unsheathed cable passing through Surface PVC conduit of size 20 mm ISI Marked (MMS)on wall/roof and making good the distrurbed surface of wall incl 6 Sq mm single core copper conductor cable PVC insulated and unsheathed cable as earth wire. Note :- Two runs of cable 6 Sqmm and One run of 6 Sqmm earth wire shall be measured as unit length.
M&L in repairs sub main wiring with 2x6 Sq mm single core multistrandred copper conductor PVC insulated and unsheathed cable passing through in existing PVC conduit of size 20 mm ISI Marked (MMS)on wall/roof and making good the distrurbed surface of wall incl 6 Sq mm single core copper conductor cable PVC insulated and unsheathed cable as earth wire. Note :- Two runs of cable 6 Sqmm and One run of 6 Sqmm earth wire shall be measured as unit length.
M&L in repairs sub main wiring with 2x4 Sq mm single core multistrandred copper conductor PVC insulated and unsheathed cable passing through in existing PVC conduit of size 20 mm ISI Marked (MMS)on wall/roof and making good the distrurbed surface of wall incl 4 Sq mm single core copper conductor cable PVC insulated and unsheathed cable as earth wire. Note :- Two runs of cable 4 Sqmm and One run of 4 Sqmm earth wire shall be measured as unit length.
Supply and fixing repair electronic driver as per sample for LED fitting up to 15watt Make Crompton/Havells/CG/Philips/Osram.
Supply and fixing repair electronic driver as per sample for LED fitting up to 36watt Make Crompton/Havells/CG/Philips/Osram.
Supply and fixing of capacitor 2.5 m.f.d , 230 volts +-5% complete all as directed. Make Havells/Crompton/Bajaj.
Supply & fixing fan capacitor 4.00 m.f.d for Exhaust Fan, all as specified and directed.Make: Havells/Crompton/Bajaj.
Supply and fixing in repair switch piano flush type 5/6 amp single pole one way 230 V all as specified & directed . Make: Havells/HPL/Anchor
Supply and fixing in repair switch piano flush type 5/6 amp single pole two way 230 V all as specified & directed . Make: Havells/HPL/Anchor
Supply and fixing in repair switch piano flush type 16 amp single pole one way 230 V all as specified & directed . Make: Havells/HPL/Anchor
Supply and fixing in repair socket out let flush type 6 amp3/6 pin 2-in-1 suitable for 5/6 Amp plug top 230 V all as specified & directed.Make: Havells/HPL/Anchor
Supply and fixing in repair socket out let flush type 3/6 pin 2-in-1 suitable for 15/16 Amp plug top multipurpose 230 V all as specified & directed.Make: Havells/HPL/Anchor
Supply and fixing in repair lamp holder insulated body with back plate batten/angle type for batten fittings complete all as specified and directed.Make: Havells/HPL/Anchor
Supply and fixing in repair bell push 5/6 Amp .Make: Havells/HPL/Anchor
Supply and fixing in repair bell AC, 230 Volts, Make: Havells/HPL/Anchor
M&L for Point wiring for modular fittings complete with 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked , class V ( Make: Havells, RR kable,KEI/ Finolex ) in concealed PVC conduit (ISI Marked) not less than 20 mm dia heavy duty with accessories in surface of wall / roof / ceiling etc and including sunken pressed steel terminal boxes in wall, including modular cover plates and 1.50 sq mm PVC insulated unsheathed stranded copper conductor (FRLS) cable for common earth and connecting to earth dolly material and labour for One light point/buzzer point controlled by one-one way switch. (Note- rates of chasing/cutting & making goods shall be included in the unit rate) :-
All as per item No. 51 above but One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
All as per item No. 51 above but One three pin 6 Amp socket on same board with other switches.
All as per item No. 51 above but One three pin 6 Amp socket on independent board.
All as per item No. 51 above but with 2.5 Sq.mm. (nominal area) cable for one 3 Pin 15 amp socket on independent board including one 2.5 sqmm copper conductor multi stranded green colour PVC insulated unsheathed cable 1100 volts grade as earth wire upto common earth & connected to earth dolly complete all as specified and directed by Eng.-in-charge.
Supply and fixing repair Modular switch any type and make 6 amp one way 230 V all as specified & directed . Make: Legrand /Havells/ABB/Indo Asian
Supply and fixing in repair Modular switch any type and make 16 amp one way 230 V all as specified & directed . Make: Legrand /Havells/ABB/Indo Asian
Supply and fixing in repair Modular socket any type and make, 6 amp 5 Pin one way 230 V all as specified & directed . Make: Legrand /Havells/ABB/Indo Asian
Supply and fixing in repair Modular socket Any Type and make, 16 amp 5 Pin one way 230 V all as specified & directed .Make: Legrand /Havells/ABB/Indo Asian
Supply and fixing in repair Modular fan Regulator step type and make, 100 watt , 230 Volts all as specified & directed . Make: Legrand /Havells/ABB/Indo Asian
Supply and fixing in repair modular cover plate with frame upto 12 module type for fixing of modular switch socket, regulators, blank plates etc complete all as specified and directed.
Supply and fixing in repair modular cover plate with frame upto 8 module type for fixing of modular switch socket, regulators, blank plates etc complete all as specified and directed.
Supply and fixing in repair modular cover plate with frame upto 4 module type for fixing of modular switch socket, regulators, blank plates etc complete all as specified and directed.
Supply and fixing in repair MCCB 100 amp TPN, 415 volts 16 KA rupturing capacity including proper thimbles, fixing on DB'S complete all as specified and directed.
Supply and fixing in repair MCB SP C Curve 5-32 Amps Make: Legrand /Havells/ABB/Indo Asian
Supply and fixing in repair MCB SPN C Curve 25/32 Amps Make: Legrand /Havells/ABB/Indo Asian
Supply and fixing in repair MCB SPN C Curve 63 Amps Make: Legrand /Havells/ABB/Indo Asian
Supply and fixing in repair MCB DP C Curve 63 Amps Make: Legrand /Havells/ABB/Indo Asian
Supply and fixing in repair MCB TPN C Curve 63 Amps Make: Legrand /Havells/ABB/Indo Asian
Supply and fixing in repair sheet metal enclosure with plug socket single pole and neutral enclosure with two pin and earth plug complete with one MCB 20AMPS SP complete all as specified and directed.Make: Legrand /Havells/ABB/Indo Asian
M&L for sheet metal enclosure with copper busbar 4 pole , 200 Amps factory fabricated powder coated finish including making cable connection with suitable size of cable luggs and cable glands including making good to distrubed surface etc complete.Make: Legrand /Havells/ABB/Indo Asian
Fixing LED batten fittings 20/22 watt, ,branded make such as Havells/Surya/ Phillips/Bajaj etc.including 1Nos tube rod complete with all accessories.
Supply and laying or fixing or passing through pipe,1100 volts grade heavy duty cable with PVC insulated aluminium solid stranded conductor served with an inner sheathing of PVC tape and overall pvc sheathed 6sq mm nominal cross sectional area.
Supply and laying or fixing or passing through pipe,1100 volts grade heavy duty cable with PVC insulated aluminium solid stranded conductor served with an inner sheathing of PVC tape and overall pvc sheathed 10sq mm nominal cross sectional area.
Supply and fixing repair PVC cassing Capping 20/25 mm ISI (MMS) all as specified and directed. Make : Polycab/Plaza
Supply and fixing repair PVC conduit 20/25mm ISI (MMS) all as specified and directed. Make : Polycab/Plaza
Supply and fixing repair PVC insulated and unsheathed FRLS single core multistranded copper conductor for repair, in existing conduit of size 1.5 sqmm as in replacement of any defective/burnt circuit.
Supply and fixing repair PVC insulated and unsheathed FRLS single core multistranded copper conductor for repair, in existing conduit of size 2.5 sqmm as in replacement of any defective/burnt circuit.
Supply and fixing repair PVC insulated and unsheathed FRLS single core multistranded copper conductor for repair, in existing conduit of size 4.0 sqmm as in replacement of any defective/burnt circuit.
S & F in replacment of u/s Street light bracket made out of 50 mm dia medium grade GI Pipe not less than 1.5m length, bent to shape including set of 50 x 6 mm GI 2 Nos Clamps nut,bolts washers,reducer of required size for suitable any type fittings etc complete including necessary painting all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 x x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elevtrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion . Note : Rates are deemed to be included for necessary earth work , earth pit with RCC cover of size 300X300 x25 mm etc complete
S&F round/ square shape surface mounted down light LED fittings 15/18 Watt complete with all accessories and including fixing arrengment etc.complete all as specified and directed. Make: Crompton/ Havells/Phillips/Bajaj/ CG/ Jaquar
S&F LED bulk head light10 watt complete with all accessories pre wired and including connecting up to fiting with flexible cable of suitable size..Make: Crompton/ Havells/Phillips/Bajaj/ CG/ Jaquar
S&F connecting, and commissioning of street light fitting 45 watt LED , IP-65 protection, single peice pressure dia cast aluminium alloy housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and contror gear compartment with high voltage surge protection device upto 4.5 KV, Prewired including 1.60 mtr long 40mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mmx6mm with bolts , nuts & washers and conductor to fitting with 3 core 1.5 sqmm pvc insulated cable complete all as specified cat part No LSTN-30-CDL of Crompton or equivalent in Havell's Cat Part No- LHEWEBP7PL6S030 & Philips Cat Part No-BRP409 .
Note for all above items:All items are fo r"Materials and labour /Supply and fix" and to be executed in "Repairs" incl taking down old materials only unless otherwise specifically mentioned as "Supply only" or "fixing only" in BOQ. Contractors are requested to quote their rates accordingly.
mahalaxmi enterprises
M/S SHREE BHAIRAV NATH ENTERPRISES
Shri Electrical Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .