| 1 | L1₹99.5 LAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹99.5 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹1.0 Cr+₹5.2 L (5.18%)Rejected-Finance G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA GUJARAT 390002 | VADODARA | VADODARA | GUJARAT | 390002 | ₹1.0 Cr+₹5.2 L (5.18%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹1.1 Cr+₹6.4 L (6.45%)Rejected-Finance 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹1.1 Cr+₹6.4 L (6.45%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹1.1 Cr+₹6.6 L (6.59%)Rejected-Finance | ₹1.1 Cr+₹6.6 L (6.59%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹1.1 Cr+₹9.6 L (9.63%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹1.1 Cr+₹9.6 L (9.63%) | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹97 L
EMD Value
₹1.7 L
Closing Date
8 Nov 2022, 6:00 pmClosed
CWE (AF) CHILODA
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
PROVN OF RING MAIN UNIT RMU AT HT LINE AT MALHAR CAMP MAKARPURA AT AFS VADODARA
2022_MES_553418_1
82128/BRD/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BARODA
As per tender document
7 documents required · 7 mandatory
₹1,000
GE (AF) BARODA
₹1.7 L
Yes
28 Nov 2022
21 Sept 2022
15 Nov 2022
21 Sept 2022
8 Nov 2022
31 Oct 2022
22 Sept 2022 - 13 Oct 2022
Amount
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed
Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as directed.
Removal of excavated material at a distance not exc 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point in soft / loose soil complete all as directed.
M&L Dry sand cushioning to underground cable with screened, washed river sand, including punning gently all as specified and directed. Note: - Thickness after punning will be measured for payment.
S& F 100 mm butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and directed.
S & F 200 mm mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two on staple plate complete all as specified
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work portions framed and hung as gates, including spindle hinges, stops, hand-made sliding bolts, etc conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F 4 mm dia galvanised mild steel wire, 150x100 mm mesh, made up into mattresses or cages, lapped, wired and laid in position including closing after filling complete all as specified and directed by Engr-in-charge.
M&L Preparation of new steel surfaces over 10 cm width of girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
Supply ,laying, jointing and testing 11 KV (Earthed), aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-II) amended upto date having cross sectional area 150 Sqmm 3 core all as specified
Supply , jointing and testing cable jointing kit of 11 KV grade cable for outdoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sq mm all as specified.
Supply , jointing and testing cable jointing kit for 11 KV(Earthed) grade cable for straight through heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured at cable of size 120 sqmm to 185sqmm all as specified Note : (i) Rate quoted shall be deemed to be inclusive of necessary excavation/ filling making good the existing surfaces with the necessary T&P as required all as directed by the Engineer-in-Charge.
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type 2 , size 450mm x 230mm x 50mm, factory made, complete all as specified
M & L Boring holes under road, pavement, hard standing by trenchless technology using Pipeline laying Horizontal Directional Drilling Technique, without casing pipe for insertion of pipe up to 100 mm complete by Horizontal Directional MACHINE all as specified and as directed.
S&F 100mm bore GI tubing light grade including all fittings laid in under road / drain/ trenches as in cable protection all as specified and as directed.
S&F Cable route indicator made out of 150 mm round disc of cast iron duly written with yellow paint as HT/11 KV cable properly fixed with nut bolts to angle iron 40X40X5 mm length 60 cms properly grouted in ground at a depth 30 cm with PCC 1:2:4 type B1 using 20 mm graded stone aggregate Size 10X10X30 cm underground, including necessary excavation earthwork complete. Angle iron shall be painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
Supply, installation ,testing, and commissioning of 4 way- 11 kV SF6 Insulated outdoor one side extensible cubical type Ring Main Unit Comprising of 2 no Incoming LBS and 2 Nos Outgoing SF6 Insulated VCB’s Type SS+VV , SF6 insulated, 11 kV vacuum circuit breaker ring main unit contained within a metal clad enclosure thickness of sheet min 2 mm thick, duly power coated (7 tank treatment) having degree of protection to IP-54, suitable for outdoor use, free standing and comprising of .:- (i) Outgoing circuit breaker 2 Nos.– 630 Amp triple pole, Motor operated vacuum circuit breaker encapsulated in SF6 Stainless Steel Tank with independent spring mechanism and fully rated earth switch with provision for earth of the cable. (ii) Outgoing circuit breaker 2 Nos. - Air insulated cable boxes with split gland plate suitable for a bottom entry 3 core cable up to 185 sq. mm (iii) Incomer load break switch 2 Nos. - 630 Amp triple pole, single break, 3 position (ON, OFF & EARTH) ring main Isolator with independent charged spring mechanism and fully rated earth switch. (iv) Incomer load break switch 2 Nos. - Air insulated cable boxes with split gland plate suitable for a bottom entry 3 core cable up to 185 sq. mm.
(v) The Ring Main Unit/secondary GIS will be complete with: (a) Mimic diagram on front panel complete with status indicators-01 Nos, (b) Set of positive standard mechanical interlocks- 01 Nos (c) Set of current transformers for protective relays CT ratio 100-200/1 A class 5P10 Burden epoxy resins cast 2.5VA for VCB- 03 Set (d) Self Powered microprocessor base Numerical Relay 3 O/C and 1 E/F(50,50N,51 & 51N ) with, communicable with rechargeable battery (for VCB unit) Make: Asida ADR2415/ABB-REH 603- 02 Nos (e) Set of Neon indicator lamps for Cable Live indication - 10 Nos (f) SF6 Gas tank with 3 mm wall thickness all side of S.S Tank wall SS 304 -01 Nos (g) External stud for earthing connections- 01 Nos (h) SF6 gas pressure indicator-01 Nos (j) Local ‘PULL TO TRIP’ mechanism- 02 Nos (k) Operating handle- 01 Nos (l) top LV chamber with provisioning battery and battery charger-01 Nos (m) Provision of FPI for O/C & SC & EF indication with LB switch - 01 Nos (n) Provision internally Auxiliary PT 11Kv/V3/415 V/V3 Volts -01 Nos Paint Finish : All steel work will be finish painted in Light Grey OR Dark grey shade as per IS: Note : (i) Isolators shall be provided with mechanical interlock . (ii) Procurement of complete unit shall be from approved OEM only warranty, certificate shall be produced by the contractor. (iii) PCC foundation as per manufacturer recommended/drawing and foundation is above the 1 mtr ground level with PCC step. (iv) Rate of foundation RMU is included RMU rate. LOCATION : MRS & AIRMEN MESS
Supply, installation ,testing, and commissioning of 6 way- 11 kV SF6 Insulated outdoor one side extensible cubical type Ring Main Unit Comprising of 2 no Incoming LBS and 4 Nos Outgoing SF6 Insulated VCB’s Type SS+VVVV , SF6 insulated, 11 kV vacuum circuit breaker ring main unit contained within a metal clad enclosure thickness of sheet min 2 mm thick, duly power coated (7 tank treatment) having degree of protection to IP-54, suitable for outdoor use, free standing and comprising of :- (i) Outgoing circuit breaker 4 Nos.– 630 Amp triple pole, Motor operated vacuum circuit breaker encapsulated in SF6 Stainless Steel Tank with independent spring mechanism and fully rated earth switch with provision for earth of the cable. (ii) Outgoing circuit breaker 4 Nos. - Air insulated cable boxes with split gland plate suitable for a bottom entry 3 core cable up to 185 sq. mm (iii) Incomer load break switch 2 Nos. - 630 Amp triple pole, single break, 3 position (ON, OFF & EARTH) ring main Isolator with independent manually charged spring mechanism and fully rated earth switch. (iv) Incomer load break switch 2 Nos. - Air insulated cable boxes with split gland plate suitable for a bottom entry 3 core cable up to 185 sq. mm
(v) The Ring Main Unit/secondary GIS will be complete with (a) Mimic diagram on front panel complete with status indicators-01 Nos (b) Set of positive standard mechanical interlocks- 01 Nos (c) Set of current transformers for protective relays CT ratio 50-100/1 A class 5P10 Burden epoxy resins cast 2.5VA for VCB- 04 Set (d) Self Powered microprocessor base Numerical Relay 3 O/C and 1 E/F(50,50N,51 & 51N ) with, communicable with rechargeable battery (for VCB unit) Make: Asida ADR2415/ABB-REH 603 qty-04 Nos (e) Set of Neon indicator lamps for Cable Live indication - 10 Nos (f) SF6 Gas tank with 3 mm wall thickness all side of S.S Tank wall SS 304 -01 Nos (g) External stud for earthing connections- 01 Nos (h) SF6 gas pressure indicator-01 Nos (j) Local ‘PULL TO TRIP’ mechanism- 02 Nos (k) Operating handle- 01 Nos (l) top LV chamber with provisioning battery and battery charger-01 Nos (m) Provision of FPI for O/C & SC & EF indication with LB switch - 01 Nos (n) Provision internally Auxiliary PT 11Kv/V3/415 V/V3 Volts -01 Nos Paint Finish : All steel work will be finish painted in Light Grey OR Dark grey shade as per IS: Note : (i) Isolators shall be provided with mechanical interlock. (ii) Procurement of complete unit shall be from approved OEM only warranty, certificate shall be produced by the contractor .(iii) PCC foundation as per manufacturer recommended/drawing and foundation is above the 1 mtr ground level with PCC step. (iv) Rate of foundation RMU is included RMU rate. LOCATION : MALHAR CAMP
Supply, installaton,testing, and commissioning of 3 way- 11 kV SF6 Insulated outdoor one side extensible cubical type Ring Main Unit Comprising of 2 no Incoming LBS and 1 Nos Outgoing SF6 Insulated VCB’s Type SS+V , SF6 insulated, 11 kV vacuum circuit breaker ring main unit contained within a metal clad enclosure thickness of sheet min 2 mm thick, duly power coated (7 tank treatment) having degree of protection to IP-54, suitable for outdoor use, free standing and comprising of :- (i) Outgoing circuit breaker 1 Nos.– 630 Amp triple pole, Motor operated vacuum circuit breaker encapsulated in SF6 Stainless Steel Tank with independent spring mechanism and fully rated earth switch with provision for earth of the cable. (ii) Outgoing circuit breaker 1 Nos. - Air insulated cable boxes with split gland plate suitable for a bottom entry 3 core cable up to 185 sq. mm (iii) Incomer load break switch 2 Nos. - 630 Amp triple pole, single break, 3 position (ON, OFF & EARTH) ring main Isolator with independent manually charged spring mechanism and fully rated earth switch. (iv)Incomer load break switch 2 Nos. - Air insulated cable boxes with split gland plate suitable for a bottom entry 3 core cable up to 185 sq. mm
(v) The Ring Main Unit/secondary GIS will be complete with: (a) Mimic diagram on front panel complete with status indicators-01 Nos, (b) Set of positive standard mechanical interlocks- 01 Nos (c) Set of current transformers for protective relays CT ratio 25-50/1 A class 5P10 Burden epoxy resis cast 2.5VA for VCB- 02 Set (d) Self Powered microprocessor base Numerical Relay 3 O/C and 1 E/F(50,50N,51 & 51N ) with, communicable with rechargeable battery (for VCB unit) Make: Asida ADR2415/ABB-REH 603-02 Nos (e) Set of Neon indicator lamps for Cable Live indication - 10 Nos (f) SF6 Gas tank with 3 mm wall thickness all side of S.S Tank wall SS 304 -01 Nos (g) External stud for earthing connections- 01 Nos (h) SF6 gas pressure indicator-01 Nos (j) Local ‘PULL TO TRIP’ mechanism- 02 Nos (k) Operating handle- 01 Nos (l) top LV chamber with provisioning battery and battery charger-01 Nos (m) Provision of FPI for O/C & SC & EF indication with LB switch - 01 Nos (n) Provision internally Auxilary PT 11Kv/V3/415 V/V3 Volts -01 Nos Paint Finish : All steel work will be finish painted in Light Grey OR Dark grey shade as per IS: Note : (i) Isolators shall be provided with mechanical interlock. (ii) Procurement of complete unit shall be from approved OEM only warranty, certificate shall be produced by the contractor .(iii) PCC foundation as per manufacturer recommended/drawing and foundation is above the 1 mtr ground level with PCC step.(iv) Rate of foundation RMU is included RMU rate. LOCATION : AF NET & SPYDER
Supply, install, testing, and commissioning of 3 way- 11 kV SF6 Insulated outdoor one side extensible cubical type Ring Main Unit Comprising of 1 no Incoming LBS and 2 Nos Outgoing SF6 Insulated VCB’s Type S+VV , SF6 insulated, 11 kV vacuum circuit breaker ring main unit contained within a metal clad enclosure thickness of sheet min 2 mm thick, duly power coated (7 tank treatment) having degree of protection to IP-54, suitable for outdoor use, free standing and comprising of :- (i) Outgoing circuit breaker 2 Nos.– 630 Amp triple pole, Motor operated vacuum circuit breaker encapsulated in SF6 Stainless Steel Tank with independent spring mechanism and fully rated earth switch with provision for earth of the cable. (ii) Outgoing circuit breaker 2 Nos. - Air insulated cable boxes with split gland plate suitable for a bottom entry 3 core cable up to 185 sq. mm (iii) Incomer load break switch 1 Nos. - 630 Amp triple pole, single break, 3 position (ON, OFF & EARTH) ring main Isolator with independent manually charged spring mechanism and fully rated earth switch. (iv)Incomer load break switch 1 Nos. - Air insulated cable boxes with split gland plate suitable for a bottom entry 3 core cable up to 185 sq. mm
(v) The Ring Main Unit/secondary GIS will be complete with: (a) Mimic diagram on front panel complete with status indicators-01 Nos, (b) Set of positive standard mechanical interlocks- 01 Nos (c) Set of current transformers for protective relays CT ratio 100-200/1 A class 5P10 Burden epoxy resins cast 2.5VA for VCB- 02 Set (d) Self Powered microprocessor base Numerical Relay 3 O/C and 1 E/F(50,50N,51 & 51N ) with, communicable with rechargeable battery (for VCB unit) Make: Asida ADR2415/ABB-REH 603-02 Nos (e) Set of Neon indicator lamps for Cable Live indication - 10 Nos (f) SF6 Gas tank with 3 mm wall thickness all side of S.S Tank wall SS 304 -01 Nos (g) External stud for earthing connections- 01 Nos (h) SF6 gas pressure indicator-01 Nos (j) Local ‘PULL TO TRIP’ mechanism- 02 Nos (k) Operating handle- 01 Nos (l) top LV chamber with provisioning battery and battery charger-01 Nos (m) Provision of FPI for O/C & SC & EF indication with LB switch - 01 Nos (n) Provision internally Auxilary PT 11Kv/V3/415 V/V3 Volts -01 Nos Paint Finish : All steel work will be finish painted in Light Grey OR Dark grey shade as per IS: Note : (i) Isolators shall be provided with mechanical interlock (ii) Procurement of complete unit shall be from approved OEM only warranty, certificate shall be produced by the contractor .(iii) PCC foundation as per manufacturer recommended/drawing and foundation is above the 1 mtr ground level with PCC step. (iv) Rate of foundation RMU is included RMU rate. LOCATION : 57 ASP & TECH FLT
Supply, install,testing, and commissioning of 2 way- 11 kV SF6 Insulated outdoor one side extensible cubical type Ring Main Unit Comprising of 1 no Incoming LBS and 1 Nos Outgoing SF6 Insulated VCB’s Type S+V SF6 insulated, 11 kV vacuum circuit breaker ring main unit contained within a metal clad enclosure thickness of sheet min 2 mm thick, duly power coated (7 tank treatment) having degree of protection to IP-54, suitable for outdoor use, free standing and comprising of :- (i) Outgoing circuit breaker 01 Nos.– 630 Amp triple pole, Motor operated vacuum circuit breaker encapsulated in SF6 Stainless Steel Tank with independent spring mechanism and fully rated earth switch with provision for earth of the cable. (ii) Outgoing circuit breaker 01 Nos. - Air insulated cable boxes with split gland plate suitable for a bottom entry 3 core cable up to 185 sq. mm (iii) Incomer load break switch 01 Nos. - 630 Amp triple pole, single break, 3 position (ON, OFF & EARTH) ring main Isolator with independent manually charged spring mechanism and fully rated earth switch. (iv) Incomer load break switch 1 Nos. - Air insulated cable boxes with split gland plate suitable for a bottom entry 3 core cable up to 185 sq. mm
(v) The Ring Main Unit/secondary GIS will be complete with (a) Mimic diagram on front panel complete with status indicators-01 Nos, (b) Set of positive standard mechanical interlocks- 01 Nos (c) Set of current transformers for protective relays CT ratio 100-200/1 A class 5P10 Burden epoxy resins cast 2.5VA for VCB- 01 Set (d) Self Powered microprocessor base Numerical Relay 3 O/C and 1 E/F(50,50N,51 & 51N ) with, communicable with rechargeable battery (for VCB unit) Make: Asida ADR2415/ABB-REH 603-01 Nos (e) Set of Neon indicator lamps for Cable Live indication - 10 Nos (f) SF6 Gas tank with 3 mm wall thickness all side of S.S Tank wall SS 304 -01 Nos (g) External stud for earthing connections- 01 Nos (h) SF6 gas pressure indicator-01 Nos (j) Local ‘PULL TO TRIP’ mechanism- 02 Nos (k) Operating handle- 01 Nos (l) top LV chamber with provisioning battery and battery charger-01 Nos (m) Provision of FPI for O/C & SC & EF indication with LB switch - 01 Nos (n) Provision internally Auxiliary PT 11Kv/V3/415 V/V3 Volts -01 Nos Paint Finish : All steel work will be finish painted in Light Grey OR Dark grey shade as per IS: Note : (i) Isolators shall be provided with mechanical interlock (ii) Procurement of complete unit shall be from approved OEM only warranty, certificate shall be produced by the contractor. (iii) PCC foundation as per manufacturer recommended/drawing and foundation is above the 1 mtr ground level with PCC step. (iv) Rate of foundation RMU is included RMU rate. LOCATION :GURDWARA & MAP
Supply, install, testing and commissioning of 4 way- 11 kV SF6 Insulated outdoor one side extensible cubical type Ring Main Unit Comprising of 1 no Incoming LBS and 3Nos Outgoing SF6 Insulated VCB’s Type S+VVV , SF6 insulated, 11 kV vacuum circuit breaker ring main unit contained within a metal clad enclosure thickness of sheet min 2 mm thick, duly power coated (7 tank treatment) having degree of protection to IP-54, suitable for outdoor use, free standing and comprising of :- (i) Outgoing circuit breaker 3 Nos.– 630 Amp triple pole, Motor operated vacuum circuit breaker encapsulated in SF6 Stainless Steel Tank with independent spring mechanism and fully rated earth switch with provision for earth of the cable. (ii) Outgoing circuit breaker 3 Nos. - Air insulated cable boxes with split gland plate suitable for a bottom entry 3 core cable up to 185 sq. mm (iii) Incomer load break switch 2 Nos. - 630 Amp triple pole, single break, 3 position (ON, OFF & EARTH) ring main Isolator with independent manually charged spring mechanism and fully rated earth switch. (iv) Incomer load break switch 1 Nos. - Air insulated cable boxes with split gland plate suitable for a bottom entry 3 core cable up to 185 sq. mm
(v) The Ring Main Unit/secondary GIS will be complete with :(a) Mimic diagram on front panel complete with status indicators-01 Nos, (b) Set of positive standard mechanical interlocks- 01 Nos (c) Set of current transformers for protective relays CT ratio 100-200/1 A class 5P10 Burden epoxy resins cast 2.5VA for VCB- 02 Set (d) Self Powered microprocessor base Numerical Relay 3 O/C and 1 E/F(50,50N,51 & 51N ) with, communicable with rechargeable battery (for VCB unit) Make: Asida ADR2415/ABB-REH 603, qty - 02 Nos (e) Set of Neon indicator lamps for Cable Live indication - 10 Nos (f) SF6 Gas tank with 3 mm wall thickness all side of S.S Tank wall SS 304 -01 Nos (g) External stud for earthing connections- 01 Nos (h) SF6 gas pressure indicator-01 Nos (j) Local ‘PULL TO TRIP’ mechanism- 02 Nos (k) Operating handle- 01 Nos (l) Top LV chamber with provisioning battery and battery charger-01 Nos (m) Provision of FPI for O/C & SC & EF indication with LB switch - 01 Nos (n) Provision internally Auxiliary PT 11Kv/V3/415 V/V3 Volts -01 Nos Paint Finish : All steel work will be finish painted in Light Grey OR Dark grey shade as per IS: Note : (i) Isolators shall be provided with mechanical interlock .(ii) Procurement of complete unit shall be from approved OEM only warranty, certificate shall be produced by the contractor .(iii) PCC foundation as per manufacturer recommended/drawing and foundation is above the 1 mtr ground level with PCC step. (iv) Rate of foundation RMU is included RMU rate. LOCATION :MANDIR S/S
M & L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth strip 32 x 6mm by means of bolts, nuts check nuts and washers of galvanised iron earth strip protection by provision of GI medium grade pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point all as specified or indicated including testing on completion Note: (i) Item includes the cost of 7.5 metre length GI pipe for protection of earth lead and earth lead . Any variation in length shall be adjusted through deviation order (ii) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance in not obtained the earthing will be redone at no extra cost
M&L Re-arrangement of existing VCB,s installed at sub stations not exceeding 25 mtr to insert including provisioning of new bus bar coupler(to be considered separately) by taking out old incoming & outgoing cable connection of any size and refixing as directed. (MRS-01 No, Sub Stn No 1 -2 Nos)
M&L Re-arrangement of existing RMU,s installed at sub stations not exceeding 25 mtr to insert including provisioning of new bus bar coupler(to be considered separately) by taking out old incoming & outgoing cable connection of any size and refixing as directedincluding S&F 02 set of current transformers for protective relays CT ratio 100-50/1 A Class 5P10 Burden epoxy resins cast 2.5VA for RMU(set) and testing with relays. (Palace sub station 06 Nos)
City Light
M K ENGINEERS CO.
SHISHODIA ENTERPRISES
ALBA AC AND REF SERVICES
vijay infraprojects pvt ltd
Nitesh Enterprise
M/s Prem Associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .