Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 CrAccepted-AOC 52 SHANTI NAGAR MODEL TOWN PANIPAT OPPOSITE AMAR STEEL SHUTTERING WORKS | PANIPAT | HARYANA | 132103 | ₹17.0 Cr Quoted ₹17.2 Cr | L1 | Accepted-AOC Award |
| 2 | L2₹17.3 CrRejected-AOC RGTPP KHEDAR HISAR HARYANA | HISAR | HARYANA | 125001 | ₹17.3 Cr | L2 | Rejected-AOC Reject |
Tender Value
₹15.3 Cr
EMD Value
₹30.7 L
Closing Date
24 Aug 2020, 10:00 amClosed
Executive Engineer, PHED No. 1 Gohana
Executive Engineer, PHED No. 1 Gohana Near MC Park Jind Road Gohana
PART A- WATER SUPPLY-AUG. WS SYSTEM OF VILL. BHAINSWAL KALAN (NAME OF WORK AS PER DNIT ATTACHED) PART B- SEWERAGE SYSTEM-PROV. SEWERAGE SYSTEM IN VILL. BHAINSWAL KALAN (NAME OF WORK AS PER DNIT ATTACHED) UNDER MAHAGRAM YOJNA
2020_HRY_138952_1
EIC Memo No. 67863-PHE/Mont. dt. 07-08-2020
Open Tender
Civil Works
547 days
Village Bhainswal Kalan Mithan and Bawla
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
Executive Engineer, PHED No. 1 Gohana
₹30.7 L
Yes
31 Aug 2020
10 Aug 2020
24 Aug 2020
10 Aug 2020
24 Aug 2020
10 Aug 2020
Amount
WATER SUPPLY-Desinging, Testing, Commissioning of automated PLC controlled SCADA based water purification plant of 1.50 MLD capacity at Existing Water Works Bhainswal Kalan Mithan & Bawla Panna all other installation etc. comprising of DI pipe from raw water main/pump, inlet box of WTP and to CWT to C.W. suction well, inlet channel, Alum dozing, Flash mixing, Clari floculator, filter box, over head Reservoir for back wash including pump sets and electric control panel, waste water tank including pump sets and electric control panel, DI pipes, DI specials, manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of floe measurement and sand bed with automation complete in all respects as per NIT (Sluice valve of make IVC/ VAG )
PUMPING MACHINERY RAW WATER PUMP SET-Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame a) RAW WATER PUMPING AT R /W PUMPING STATION -4700 LPM, 90 B.H.P., 50 M. Head
b) EXISTING WATER WORKS BHAINSWAL KALAN MITHAN PANNA- 1300 LPM, 7.50 B.H.P., 12 M. Head
c) EXISTING WATER WORKS BHAINSWAL KALAN BAWLA PANNA-1100 LPM, 7.50 B.H.P. 12 M. Head
CLEAR WATER PUMPING SET -Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame- a) EXISTING WATER WORKS BHAINSWAL KALAN MITHAN PANNA-2600 LPM, 30 B.H.P., 40 M. Head
b) EXISTING WATER WORKS BHAINSWAL KALAN BAWLA PANNA-1900 LPM, 30 B.H.P. 40 M. Head ( For Distribution )
400 LPM, 5 B.H.P. 25 M. Head ( For Filling Boosting Stn. )
3A-Supply & fixing following CI D/F pipe and sluice valve/ non return valves/ bell mouth / reflux valve including cost of jointing materials, excavation, laying jointing refilling including making adequate supports of masonry/ concrete steel for delivery and suction pipe from bell mouth in the collecting tank upto the rising main laid by the department as per plan shown from the foundation wall of the pump chamber for all the raw water and clear water pumping sets at water works as per specification given in schedule No.II Details of pipe- CI D/F bends, reducers, tees etc ( For 2 Nos. Water Works ) (i) CI D/F pipes 100mm i/d
(ii) 150mm i/d
(4) a- Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400mm deep having following item:- (for 2 Nos. Raw Water Set) For Old WW set 4700 LPM x 50 M Head = 1 Nos. For Various Pumping Machinery as Under . A Main switch 100 Amp 1 No. (L&T siemens, ABB). B Volt meter 100x100mm range 0 to 500 volt= 1 No. (AE/KAPPA/L&T) C Amp. Meter 100x100mm range 0 to 100 volt= 2 No. (AE/KAPPA/L&T) D CT 100/3 No. (AE/KAPPA/L&T) E VSS & ASS 1 No. each No. of approved make F SSP 4 No. of approved make/ minilac G Motor starter star delta 1 Nos. for 4700 LPM x 50Head motor (L&T, Siemens, ABB) H Capacitor KVAR as per site requirement I Indicating Lamp One Set J Change over Switch 100 Amp. = 1 No.
(4b)-- Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400mm deep having following item:- (for 2 Nos. Raw Water Set) For Various Pumping Machinery as Under . A Main switch 100 Amp 1 No. (L&T siemens, ABB). B Volt meter 100x100mm range 0 to 500 volt= 1 No. (AE/KAPPA/L&T) C Amp. Meter 100x100mm range 0 to 100 volt= 2 No. (AE/KAPPA/L&T) D CT 100/3 No. (AE/KAPPA/L&T) E VSS & ASS 1 No. each No. of approved make F SSP 4 No. of approved make/ minilac G Motor starter star delta 2 Nos. for 1300 LPM x 12 Head motor 7.50 BHP (L&T, Siemens, ABB) H Capacitor KVAR as per site requirement I Indicating Lamp One Set J Change over Switch 63 Amp. = 1 No. h) indicating Lamp - One Set
(4c)-- Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400mm deep having following item:- (for 2 Nos. Raw Water Set) For Various Pumping Machinery as Under . A Main switch 100 Amp 1 No. (L&T siemens, ABB). B Volt meter 100x100mm range 0 to 500 volt= 1 No. (AE/KAPPA/L&T) C Amp. Meter 100x100mm range 0 to 100 volt= 2 No. (AE/KAPPA/L&T) D CT 100/3 No. (AE/KAPPA/L&T) E VSS & ASS 1 No. each No. of approved make F SSP 4 No. of approved make/ minilac G Motor starter star delta 2 Nos. for 1100 LPM x 12 Head motor 7.50 BHP (L&T, Siemens, ABB) H Capacitor KVAR as per site requirement I Indicating Lamp One Set J Change over Switch 63 Amp. = 1 No.
(4d)-- Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400mm deep having following item:- (for Clear Water Pump set 2600 LPM x 40 M Head = 1 Nos.) For Various Pumping Machinery as Under . A Main switch 100 Amp 1 No. (L&T siemens, ABB). B Volt meter 100x100mm range 0 to 500 volt= 1 No. (AE/KAPPA/L&T) C Amp. Meter 100x100mm range 0 to 100 volt= 2 No. (AE/KAPPA/L&T) D CT 100/3 No. (AE/KAPPA/L&T) E VSS & ASS 1 No. each No. of approved make F SSP 4 No. of approved make/ minilac G Motor starter star delta 2 Nos. for 2600 LPM x 40 Head motor (L&T, Siemens, ABB) H Capacitor KVAR as per site requirement I Indicating Lamp One Set J Change over Switch 200 Amp. = 1 No.
(4e)-- Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400mm deep having following item:- (for Clear Water Pump set = 2 Nos.) For Various Pumping Machinery as Under . A Main switch 100 Amp 1 No. (L&T siemens, ABB). B Volt meter 100x100mm range 0 to 500 volt= 1 No. (AE/KAPPA/L&T) C Amp. Meter 100x100mm range 0 to 100 volt= 2 No. (AE/KAPPA/L&T) D CT 100/3 No. (AE/KAPPA/L&T) E VSS & ASS 1 No. each No. of approved make F SSP 4 No. of approved make/ minilac G Motor starter star delta 2 Nos. for 1900 LPM x 40 Head motor 30.00 BHP BHP (L&T, Siemens, ABB) H Capacitor KVAR as per site requirement I Indicating Lamp One Set J Change over Switch 63 Amp. = 1 No.
(4f)-- Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400mm deep having following item:- (for Clear Water Pump set = 2 Nos.) For Various Pumping Machinery as Under . A Main switch 100 Amp 1 No. (L&T siemens, ABB). B Volt meter 100x100mm range 0 to 500 volt= 1 No. (AE/KAPPA/L&T) C Amp. Meter 100x100mm range 0 to 100 volt= 2 No. (AE/KAPPA/L&T) D CT 100/3 No. (AE/KAPPA/L&T) E VSS & ASS 1 No. each No. of approved make F SSP 4 No. of approved make/ minilac G Motor starter star delta 2 Nos. for 400 LPM x 25 Head motor 5.00 BHP BHP (L&T, Siemens, ABB) H Capacitor KVAR as per site requirement I Indicating Lamp One Set J Change over Switch 63 Amp. = 1 No.
Supply erection testing and commissioning of exhaust fans each having a capacity of 45 cubic meters per minutes, complete with suitable G.I sheet Ducting in meter room and pump Chamber and energy for the sites. ( R/W Pump House & 2 Nos. Water Works )
Supply erection & testing of Ceiling fan of size 48" i/d (1200 mm) of reputed ISI make complete in all respect. ( R/W Pump House & 2 Nos. Water Works )
Supply erection, testing of light fitting including wire in the pump chamber with material upto 10 points including switch, button, plug, PVC conduict pipe & copper wire etc. as per approved specifications. ( Pump Chamber at W/W Mithan Panna
Providing and fixing of insulated Rubber matting suitable for HKV installation 1 meter x 2 meter x 12 mm as per specification. (Pump House and 2 Nos. Existing Water Works )
S&S Tank- (a) Providing & fixing suitable floating arme 300 mm size along with swivel bend as per required specifications approved by Engineer-in-Charge ( Both Water Works )
(b) -Supply erection, and commissioning electric operated dewatering pump of 3 HP Kirlosker make complete from priming with wiring starters switches etc. also the required GI pipe (B Class) valves and sight glass etc. complete.
FUNCTIONAL HOUSE HOLD TAP CONNECTION - (a) Providing laying jointing, fixing, testing G.11 pipe ( as approved by Engineer in charge ) including cost of specials such as tees. Bends sockets elbow etc. Cutting treading & testing in trenches in the ground complete ( from ferrule to stop cock ) ( 15 mm i/d )
TRANSFORMER , D.G. SET - (A) Design , Supply & Erection of 1 No. copper wound Transformer of 100 KVA ( at Raw Water Pumping Station ) 63 KVA Each ( At Both Existing water Works ) on load tap charger or suitable capacity on higher side of stsnderd make outdoor type , VCB panel , G.O. Switch , H.T. metering panels along with for each transformer , 11 KV substation , entire cable network from G.O. switch to H.T. metering equipment and from H.T. metering equipment to Transformer Main to L.T. Panel , Earthing , Safety equipment and any other contingent thereto complete in all respect as per DNIT and getting it passed from Chief Electrical Officer including operation & Maintainance of 5 years . (a) 100 KVA
(B)-Supply erection, testing and commissioning of diesel generating set laying noise control acoustic enclosure radiator colled, 3 phase, 4 wire, 50 cycles 415+ (-) 1% volts AC alternator coupled directly through a set of flexible coupling on a common M.S. fabricated base frame with Diesel Engine. The rating should be at 1500 RPM, (a) Diesel Engine, (b) Alternator, (c) Base Plate, (d) Bettery 24 V, (e) 1x120 sq mm 3.0 core XLPE Aluminum = 20 m, (f) Tools, A.M.F. PANEL, (a) Motorised change over switch 250 Amp 4 P with fuse base and HRC links 250 Amp.(b) Under voltage/ over voltage relay - 2 No. 415 VAC, (c) Engine Start relay 24 VDC 1 No., (d) Electronic Timber 24 VDC 1 No. , (e) Electronic Timber 24 VDC 2 No., (f) Auxiliary relay 220 VAC - 2 No.,(g) Auxiliary relay 220 VAC - 3 No., (h) Metering set 415 VAC - 1 set (Amp. Meter, Volt Meter, ASS, VSS, Phase Indicaters, Control fuse, frequency meter, CT'S), (i) Metering set 24 V DC (Amp. Meter, Volt Meter) , (j) Over Load protection for DC - 1 No. , (k) Battery Charger 24 V DC (Blueron make), (l) Copper bus bar of suitable size, (m) KWH meter 96 square mm size, (n) Starting fuse button and key switch (On/Off), (o) Engine Protection unit with Audiovisual alarm and shut down for low lubricating oil pressure and high coolant temperature., (p) Indicating lump for low lubricating oil pressure high collant tempurature, set running, load on, DC control on., Note: Control Panel shall have the provision to provide auto manual failure panel (AMFP). (a) 125 KVA
SEWER SYSTEM -Providing at installation of 2 Nos. Non Clog sewerage Submersible pumping sets complete as given below at IPS Supplying of Non Clog sewerage submersible pumps.Model JSE-6, single stage, side delivery volume casing type, Pump efficiency BKW, Motror efficiency , rating 25.00/18.6/1450 RPM, "f" CLASS , Air fiill, ball bearing with 40000 Hrs life,Grease lubricated,solid Handling , Pump delivery size 150-250 mm,Type of motor TEWC, pump casing C.I.F.G.260, Implar 3-3-16, S.S- 410 shaft,SS-316, 415 Volts, 50 Hr, A.C. suppply, Star Delta, Thrmister & moisture sencer,IP-68/DUTY:81, Cable 10 m of required size, Auto coupling with intergal C.I.bend & ss Hardware-1 set, 50mm Galvanised guide pipe, M.S.Galvanised lifting chain with shackle 15 mtr length complete as per IS specification.( Non Clog Submersible sewage pumps of 36 m3/Hr (DWF) with Head 12 Mtr. all other accessories complete in all respects 500 LPM) 15 M Head- . Non Clog Submersible sewage pumps of 30 m3/Hr (DWF) with Head 20 Mtr. all other accessories complete in all respects.500 LPM) 15 M. Head
Supplying and fixing following C.I. D/F pipe, CI specials, sluice valves with wheel, non return valves with G.M. Flap including cost of jointing materials, excavation, laying refilling including making adequate supports of masonry / concrete / steel for delivery pipe from submersible pump set up to 1.5 meter outside the outer wall of pump chamber as per specification given in Schedule No II. (A) Detail of pipe and specials (a) C.I. D/F Pipes (ii) 150 mm i/d D/F Pipes
(ii) 300 mm i/d D/F Pipes
Note:- i) The ACB, MCCB, contractors, ammeter etc. shall be of suitable rating as per the load requirement . ii) All the power connections should be with solid copper bus bar of suitable rating.- Supply, erection, testing & commissioning Automatic Power Factor correction factor panel of 60 KVAR with automatic Power factor correction in various steps with incoming MCCB with complete metering.
Providing, and fixing of insulated rubber matting suitable for 11 KV installation 1 metre x 2 metre x 12 mm for site as per specifications .
Providing and fixing of exhaust fans each having a capacity of 45 cubic metres per minutes complete with suitable GI sheet ducting in pump chamber.
Providing and fixing of ceiling fans 48” i/d (1200 mm) with suitable GI pipe complete in all respects.
Supply erection, testing of standard make Lighting in the Pump chamber with material upto 10 points including switch, button, plug, PVC pipe & wire etc
Operation and maintenance for the complete scope of work meintioned in the DNIT ( Disinfection material supplied by the PHEd) as per schedule –IV for a period of 5 years after 3 month trail run ( will be changed to the A/mtc Estimate)-(i)-Opertation an Maintenance during Defect liability period (Operation Only)
(ii) Operation and maintencance during 1st year after defect liability period
(iii) Operation and maintenance during 2nd year
(iii) Operation and maintenance during 3rd year
(v) Operation and maintenance during 4th year
(v) Operation and maintenance during 5th year
Bidder Name
Amount
Jai Shree Balaji Constn Co.
NAFE SINGH CONTRACTOR
NAFE SINGH CONTRACTOR
Jai Shree Balaji Constn Co.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid