Loading…
Loading…
Tender Value
₹1.7 Cr
EMD Value
₹1.7 L
Closing Date
12 Aug 2026, 4:00 pm
Executive Engineer, Electric (R&B) Division, Rajkot
Providing and Erecting Air Conditioner Machine in Registrar Rooms, Stenographers Rooms, Branches and Staff Rooms in Court Building of Rajkot, Jamkandorana, Padadhari , Upleta , Bhayavadar , Vinchiya , Jasdan , Dhoraji , Jetpur & Gondal .
327036
No. 05 of 2026-27
Open
Electrical Works
Works
Rajkot
8 documents required · 8 mandatory
₹3,600
Executive Engineer, Electric (R&B) Division, Rajkot.
₹1.7 L
23 Jul 2026
23 Jul 2026
23 Jul 2026
12 Aug 2026
23 Jul 2026
Name of work: Providing and Erecting Air Conditioner Machine in Registrar Rooms, Stenographers Rooms, Branches and
Staff Rooms in Court Building of Rajkot, Jamkandorana , Padadhari , Upleta , Bhayavadar , Vinchiya
Jasdan , Dhoraji , Jetpur & Gondal .
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Providing and erecting Inverter based approved make split air-
conditioning unit consisting of condensing unit with variable
speed fan motor, inverter type hermetically sealed rotary
compressor with accessories etc. duly connected separately
erected evaporating unit and blower motor with its accessories
by means of extra supplied proper insulated copper
1 230 Ea tubing,drain PVC pipes suitable for ( cost includes Eco 61989.76
Friendly green gas charging and 15A plug top & Remote
Control & MS Stand) with necessary core cutting.. (1)For
ISEER Range (KWH/KWH)(3.1 to 3.99) (C) for 1.9 to 2 ton
capacity - Premium Cat. (Mitsubishi Electric Model No.
MSYJZVF3/O General Model No. ASGG24CPWA)
Supplying and erecting insulated pair of soft copper tubing
open or concealed including power and control
2 1495 Rmt cable,necessary PVC drain pipes for Split/Cassette AC 1158.47
machine up to 4 TR capacity
Supply and Erecting of Static Stabilizer suitable for following
capacity of A.C Machine the Stabilizer Must have Minimum
Technical Specification are Input working Single Phase
Voltage Range Up to 150V-280V.50Hz, Output Voltage
Range Up to 200V-240V,50Hz,Autoreset Facility,LED
Display for Indicating Voltage,Spike/Surge Protection,Time
3 230 Ea Delay Facility,Proper Wall Mount Facility with Required 4029.9
Accessries & on site 3 year Replacement/Repairing
Warranty.(2) For 2 Ton Thermal Overload Protection 15 Amp.
( Make : Microtek Imnternational, V-Guard Industries Ltd.,
Luminous Power Technologies, Bluebird Power Controls, Liv
Guard Energy Technologies.)
Note:- The Credit of dismentalled materials for Rs.00.00 shall be recovered from the First R.A. bill payable to the contrator and
there after the dismentalled materials shall be the property of the contractor.
I/We am/are willing to carry out the work at__________________% above/below (in
figures)_____________________________________percent Above / below (in words) the estimated rates mentioned above amount of
my\our tender works out as under :-
Estimated amount put to Tender Rs. _________
Deduct________% below Rs. _________
Net Amount Rs. _________
Estimated amount put to Tender Rs. _________
Net Amount Rs. _________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local situation
regarding material,labour and other factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications and
other tender documents of this work and agree to execute the same accordingly.
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
C Any Excess in Tender Item/Extra Item if Needs to be Execute. Contractors has to carry out work on the instruction
of Competant Authority on Tender Submitted rate,No Excuse will be Accepted.Hence Contractor are Requested to
quote the rate considering this condition.
D Contractor are requested to quote the Tender by considering that payment will be made after availibility of
grant.Contractor has to start the work immediately after issue of Work Order and as per instruction of Engineer-in-
Charge irrespective of availibility of grant.
E "This estimate has been prepared on the new SOR wich is exclusive of GST hence GST additional will be paid to
the agency as per existing guidelines."
(Signature of the Contractor)
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ONLINE_NOTICE(R-2)(dn) RJT.pdf
SCH-B.pdf
AC Stabilizer.pdf
ANNEXURE-A (3).pdf
SBD.docx
DOCX
Contractor_Registration_Paripatra__1_.pdf
EMD GR.pdf
GR for Extra Item.pdf
GR for single Tender.pdf
ANNEXURE-B.pdf
ANNEXURE-C.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].