| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹43.1 LAccepted-AOC | L-1 | Accepted-AOC Ist Lowest | |
| 2 | L-2₹43.2 L+₹6,017.72 (0.14%)Rejected-Finance 04 7906130592 | L-2 | Rejected-Finance Hiegher | |
| 3 | L-3₹43.2 L+₹11,974.51 (0.28%)Rejected-Finance KHATIMA UDHAM SINGH NAGAR | UDAM SINGH NAGAR | UTTARAKHAND | 244712 | L-3 | Rejected-Finance Hiegher | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹86,500
Closing Date
17 Jun 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, RWD, U S Nagar
Beautification work of Lalkothi Sharda Ghat temple in khatima
Beautification work of Lalkothi Sharda Ghat temple in khatima
2021_RES_33381_1
212/2-lekha/01.06.2021
Open Tender
Civil Works
Item Rate
180 days
Khatima
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
executive engineer, rwd, rudrapur
₹86,500
25 Jul 2023
9 Jun 2021
17 Jun 2021
9 Jun 2021
17 Jun 2021
9 Jun 2021
120 days
Amount
TILE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 60x60 cm
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand)Light shade pigment using white cement
BOUNDRY WALL Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.in all kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:6 (1 cement : 6 coarse sand
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
12 mm cement plaster of mix1:6 (1 cement : 6 fine sand
15 mm cement plaster on rough side of single or half brick wall of mix1: 6 (1 cement: 6 fine sand)
Finishing walls with Acrylic Smooth exterior paint of required shadeNew work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
SHED WORK Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.in all kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinthsides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, leadup to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with Jamuna sand under floors, includingwatering, ramming, consolidating and dressing complete
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:6 (1 cement : 6 coarse sand
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in Beam,suspended floor roof having slop up to 15 degree landing balcony shelf chajjas lintels band plain windoe cills staircase & sprial stair case etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size)
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. TMT bars Fe500D
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with dash fastener or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and nuts as required including fixing of necessary butt hinges and screws and applyinFixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
12 mm cement plaster of mix1:6 (1 cement : 6 fine sand
15 mm cement plaster on rough side of single or half brick wall of mix1: 6 (1 cement: 6 fine sand)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 60x60 cm
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing ISI marked oxidised M.S. sliding door bolts withnuts and screws etc. complete :300x16 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, 200x10 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS125 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodisedTwin rubber stopper
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows alll complete.With 4.0 mm thick glass panes.
Providing & fixing fly proff wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 m and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including finishing the topsmooth.
Brick edging 7cm wide 11.4 cm deep to plinth protection with commonburnt clay F.P.S. (non modular) bricks of class designation 7.5 includinggrouting with cement mortar 1:4 (1 cement : 4 fine sand).
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C.projections.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work
Steel work in built up tubular (round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer, including welding and bolted with special shapedwashers etc. complete.Hot finished welded type tubes
Supply & installation of precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm +/- 5% total coated thickness (TCT) thick Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall befixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete Ridges plain (500- 600 mm)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete Gutter ( 600 mm over all girth).
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories bend 110mm diameter
Miscellaneous Item Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.in all kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster of mix1:6 (1 cement : 6 fine sand
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick.
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Filling with carted earth (excluding rock) in plinth etc in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, leadup to 5,0Km and lift upto 1.5 m.
Supply and Installation of submersible pump including all cost complete upto 60 mtr deep
Toilet Block Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.in all kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinthsides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, leadup to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with Jamuna sand under floors, includingwatering, ramming, consolidating and dressing complete
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:6 (1 cement : 6 coarse sand
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure abov plinth level upto floor V level inCement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks).
Providing and laying in position specified grade of reinforced cement concrete1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in Beam,suspended floor roof having slop up to 15 degree landing balcony shelf chajjas lintels band plain windoe cills staircase & sprial stair case etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size)
Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform.
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. TMT bars Fe500D
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with dash fastener or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
12 mm cement plaster of mix1:6 (1 cement : 6 fine sand
15 mm cement plaster on rough side of single or half brick wall of mix1: 6 (1 cement: 6 fine sand)
Smooth finishing of the exposed surface of R.C.C. work with 6 mm thickcement mortar 1:3 (1 Cement : 3 fine sand).
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm includingpointing the joints with white cement and matching pigmentetc., complete.
Providing and fixing ISI marked oxidised M.S. sliding door bolts withnuts and screws etc. complete :300x16 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, 200x10 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS125 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodisedTwin rubber stopper
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows alll complete.With 4.0 mm thick glass panes.
Providing&laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface prepration, first layer of slurry of cement@ o.488kg/sqm mixed with waterproofing compound &.0.253kg/sqm (b) laying second layer of fiber glass cloth when the first layer is still green. overlaps of joints of fiber glass cloth should not be less than 10 cm.(c)third layer of 1.5mm thickness consisting of slurru of [email protected]/sqm mixed with waterproofing [email protected]/sqm and course [email protected]/sqm thish will be allowed to air cure for 4 huors followed by wter curring for 48 hours. the entire treatment will be taken up to 30cm on parapit wall and tucked into groove in parapit all around(d) fourth &final layer of brick tiling with cement morter (which will be paid seprately .for purpose of measurement the entire treated surface will be measured.
12 mm cement plaster finished with a floating coat of neat cement of mix 1:3
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Concealed pipe with anti corrosive bitumastic paint, cutting chases and making good the wall15 mm dia nominal bore
Concealed pipe with anti corrosive bitumastic paint, cutting chases and making good the wall 20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work)15 mm dia. nominal bore
Providing and fixing brass stop cock of approved quality15 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)20MM nominal bore
Providing and fixing ball valve (brass) of approved quality completeHigh or low pressure with plastic floats15 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms15mm nominal bore..
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15mm nominal bore.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)15 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)20 mm nominal bore
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mmWhite Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C. brass pillar tap.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C.Flexible pipe32mm dia
Providing and fixing uplasticised PVC connection pipe with brassunions :30 cm length15 mm nominal bore
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not lessthan 106 gms.
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finishedWith F.P.S. bricksInside dimensions 455x610 mm and 45 cm deep for single pipe line :
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes75 mm diameter
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories coupler 75mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories coupler110mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories single tee 75x75x 75mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories single tee 110x110x110mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories bend 75mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories bend 110mm diameter
Finishing walls with Acrylic Smooth exterior paint of required shadeNew work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
providing and applying white cement based putty of average thickness 1mm of approved brand and manufacture, over plastered wall surface to prepare the surface even and smooth complete
Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete, as per manufacturer’s specificationTwo or more coats on new work.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including finishing the topsmooth.
Brick edging 7cm wide 11.4 cm deep to plinth protection with commonburnt clay F.P.S. (non modular) bricks of class designation 7.5 includinggrouting with cement mortar 1:4 (1 cement : 4 fine sand).
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10of approved quality using 1.7kg per square metre on damp proof course aftercleaning the surface with brushes and finally with apiece of cloth lightlysoaked in kerosene oil.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C.projections.
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honeycomb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m longcomplete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
DEV ENTERPRISES
Ajay Mourya
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .