Tender Value
₹9.0 Cr
EMD Value
₹9.0 L
Closing Date
2 Jul 2026, 4:00 pm
Similar tender results from the same govt authority in the past 3 years.
Ahmedabad Municipal Corporation Central Zone
CONSTRUCTION OF COMMUNITY Hall AT T. P. S. No. 5 (City Wall Improvement) (Section - 7) Final Sanc., F. P. No. 26 Ahmedabad, near dariyapur Darwaja central zone.
313530
02/ 2026-27
Open
Miscellaneous Works
Ahmedabad
3 documents required · 2 mandatory · 1 optional
₹12,000
Municipal Commissioner, Ahmedabad
₹9.0 L
11 Jun 2026
11 Jun 2026
11 Jun 2026
2 Jul 2026
11 Jun 2026
5 30.00 Extra above over item of boring to the rates of bore holes
of 3.5 mtr if bore are made deeper than 3.50 mtr. For a)
300 mm dia. Rmt. 539.34
6 970.00 Excavation for foundation upto 1.50 Mt depth including
sorting out and stacking useful materials and disposing
off the excavated stuff upto 50 Meters lead (B) Dense or
hard soil. Cmt. 259.14
7 970.00 Excavation for foundation 1.50 Mt to
3.0 Mt. depth including sorting out and stacking useful
materials and disposing off the excavated stuff upto
Meters lead (B) Dense or hard soil.
8 323.50 Excavation for foundation 3.0 Mt. to
5.00 Mts. depth including sorting out and stacking useful
materials and disposing off the excavated stuff upto
Meters lead (B) Dense or hard soil.
9 100.00 Filling available excavated earth (excluding rock) in
trenches, plinth, sides of foundations etc. in layers not
exceeding 20 cm. in depth, consolidating each deposited
layer by ramming and watering etc. complete.
10 10.00 Filling in foundation and plinth with murrum or selected
soil in layers of 20 cm. thickness including watering,
ramming and consolidating etc. complete. Cmt. 286.20
11 10.00 Sand filling with sand as approved by Architect in plinth /
under floor / elsewhere including watering, ramming,
consolidating and dressing to the required grades and
levels as directed by Clerk-of-Work.
12 2025.0 Anti-Termite System: Providing and laying of
0 permanent piping technology anti-termite treatment
before flooring work by installing LLDP (Low linear
density polyethylene) tube of 8 mm O.D. & 6.4 mm 1.D.
with inbuilt pressure compensation chip every 30 cm
interval in the tube, having working pressure of 2 Kg/cm2
and release rate of 1.9 Itr/hour fixed by P-clips and nails.
The LLDP pipe shall be installed at the entire periphery of
the building and at internal network of building at a depth
of 20 to 200 mm under floor at every 2 to 3 mtr. c/c
distance (adjusted as per building layout ) & Ends of loop
pass through a PVC elbow of minimum 32 mm ID at
junction box of wall and floor level, entering into a steel
reinforced grooved flexible pipe of minimum 22 mm ID
leading into junction box and the loops shall terminate in
junction boxes & test every junction during injecting
chemicals for termite control treatment. The anti termite
chemical Imidacloprid 30.5% SC mix as per IS-6313 (part
III) shall be injected by the pressure pump diluted with
water @ 10.5 ml/5 ltr of water at the rate of 2 Kg/sq.cm @
5 Ltr/SMT. The contractor shall submit approved line plan
for piping system and junction boxes dully approved by
Engineer-in-Charge with bond of 5 year warranty.(i)Anti
Termite chemical injected area (Chemical injecting incl.
labour cost) Sq. mt 133.00
13 2025.0 Carrying out timber treatment to all woodwork,
0 including drilling holes and spraying oil-based chemical
solution on the surface of timber work for termite control,
including labor and material etc., complete. Using
Chlorpyriphos20 EC as per 6313 2013 Part III (1%
concentration by mass) is recommended: one litre of
chemical emulsion diluted with 19 litres of kerosene.
Total diluted concentration will be 20 liters, inclusive of
liter chemical emulsion application in drilled holes and
0.75 / Litre chemical per one Sqmt two coat on wood
surface not protected by paint or varnish. Sq. mt 54.98
14 3100.0 Applying general insecticide pest control treatment to
0 floors, cupboards etc including labour materials etc.
complete. Using Imidacloprid 30.5 SCas Per IS 6313 part
-II( (0.075% concentration by mass) is recommended
10.5ml chemical diluted with 5 liters of water application
0.5 litre chemical /Sqm of surface is recommended as per
15 600.00 Carrying out plinth treatment to post construction /
existing structure by spraying chemical solution for
termite control treatment, including labour and material,
consistent with I.S.I specification. Using Chlordene and
Chlorpyrifos 20 EC. As Per 6131_paret-II Concentration
Weight one percent is recommended i.e one litre 20 EC
chemical emulsion with 19 liter give 1 % concrentration,
inclusive of one litre chemical emulsion application at the
rate of 5 Litre chemical / Sqm of surface is recommended
as per I.S Sq. mt 104.90
16 2690.0 Carrying out wall treatment for termite control,
0 including spraying with chemical solution in oil base,
including labour and material. Using Chlorpyriphos
ECAs per IS 6313 part- II (1% concentration by mass) is
recommended i.e one litre chemical emulsion diluted with
19 litres of oil base. Total solution will be 20 liters
inclusive of one liter chemical emulsion application at the
rate of 7.5 litres chemical / Sqm of surface is
recommended as per I.S.
17 Conveyance charge of lime , murrum, building rubbish,
earth manure or sludge, and excavated earth and fly ash
and any kind of debris etc. complete. No dry factor for
this item shall be calculated.
a 800.00 a) Upto lead of 5 Kms. Cmt. 235.51
b 300.00 b)Conveyance Charge (Extra Rate) above 5.00 Km
and Up to 10.00 Km. Cmt. 350.00
B CONCRETE AND ALLIED WORK
18 100.00 Providing and laying cement concrete 1:3:6 (1- Cement :
3 - Coarse aggregate : 6-Hand broken stone aggregates
mm nominal size) and curing complete excluding
formwork in (A) Foundation and plinth.
19 550.00 Providing and laying in situ controlled Reinforced Cement
Concrete of Mix M20 grade using cement of OPC and
20mm and down size machine crushed black trap of
approved coarse aggregate and fine aggregates confirming
to IS: 383 - 2007, by concrete batch mix plant, weight
batch machine mixed and machine vibrated design mixed
concrete, including design of concrete mix and shall be
confirming to latest IS : 456, IS : 10262 : 2009, SP23 &
SP24 with minimum cement content of 325 Kg per CUM
of concrete and if necessary adding admixtures in
recommended proportions as per IS : 9103 as retarding
admixture to retard setting of concrete and or water
reducing admixture to maintain workability with reduced
amount of water and to improve durability without
impairing strength of concrete for any type, any shapes
and any sizes of reinforced cement concrete structural
members and mass concrete such as..........for foundation,
raft, retaining wall, column, pedestals, ground/plinth
beam, beam, suspended slab, coping, wall lintel , weather
shed, chajjas, lofts, steps and waist slab of staircase,
platform, canopy, peragolas, parapet, dropwall, window
cills, mullions, facia, fins, gutter, bed block, ramp,
overhead and under ground water tank........etc., as shown
in the drawings and specifications for all sectionc in all
position for including mixing, transporting, pumping and
placing (pouring), hoisting, necessary scaffolding,
vibreting , finishing evenly, watering, levelling,
roughening and or hacking concrete at construction joints,
leaving pockets and holes, keeping drip moulds, grooves,
including curing, testing etc.with rigid and waterlight
centering and shuttering as ordinary formwork using steel
/ plywood shuttering materials for horizontal, vertical and
inclined membe of rectangular, square, round, hexagonal,
octagonal or curved shape, including necessary propping,
scaffolding, bracing, shorig, strutting, bolts, fastener nails
etc; and keeping the same in position during and after
concreting and careful stripping / careful removal of the
same at and up to appropriate time, applying approved
shuttering oils and by approved manner will prior to
placing the reinforcing steel in position to ptevent the
adhesion of concrete to form work etc. complete and as
directed and specified by PMC / ARCHITECT /
(1) The Concrete Mix Design shall be done by the
CONTRACTOR in testing laboratory approved by PMC /
ARCHITECT / ENGINEER with the Maximum Water
Cement ratio shall be limited to 0.50.
(2) The concrete design mix shall be of without mixing
/ using of Admixtures / Additives to achieve the desire
strength etc; and it shall be not paid extra.
(3) Rate EXCLUDES providing and installing
Reinforcement Steel, conduits, sleeves and inserts & form
work-Shuttering and Centering.
(4) If in Concrete Mix Design Fly Ash is allowed to use
with OPC cement - use of Fly Ash as maximum 25 % by
weight of total cementatious material to replace by Fly
Ash conforming to IS : 3812 - 2013 (Latest), than Price
Difference between OPCement and Fly Ash shall be
discounted / adjusted in next respective RA
20 273.10 -Do- as per above item but from below ground level to
Ground Floor Slab level Cmt. 12500.00
21 353.00 -Do- as per above item but from Ground floor Slab to
First Floor Slab level Cmt. 13500.00
22 307.00 -Do- as per above item but from First floor Slab to Third
Floor Slab level Cmt. 13500.00
23 313.00 -Do- as per above item but from THird floor Slab to Fifth
Floor Slab level Cmt. 13500.00
24 790.25 Extra for M
25 1005.8 Extra for M
26 142 Providing TMT Bars FE- 550 reinforcement for R.C.C.
000.00 work including bending, binding and placing in position
complete upto floor two level. Kg 75.46
27 Providing, laying and fixing in position galvalume pre
painted and pre coated (PPGA) trapezoidal profile sheets
(size, shape and pitch of corrugation as approved by PMC
/ ARCHITECT / ENGINEER) with special male / female
side laps and anti siphoning feature at male and to prevent
leakage made from high tensile strength - 345mpa /
500mpa GALVALUME steel and AZ-150gsm Zincalume
coating to total on both side as per ASTM 1397 (55%
aluminium + 43.5% zinc and 1.5% silicon) having sheet
0.55mm TCT at top and base metal thickness 0.48/0.5mm
including colour coating of 20 micron finish coat over
micron primer coat on exposed side and back coat of
microns over a primer coat of 5 microns and having
protective gard film of 25 micrones to avoid stretches
while handling the sheet and upto erection process for
roofing and side clading, approved make and approved
shade, for roofing at all levels and heights including
cutting sheets and drilling the holes with side laps as
required and end laps 150mm to 200mm including fixing
by self tapping and self drilling 8 mm dia x 55mm long
SDST screw of 'BUIDEX' orcorroshield make as per AS -
3566 class-3 with EPDM seal, washer of 25mm dia 3mm
thick bitumen washer with 6mm central hole to form
water proof joint etc. and using templates as suggested by
manufacturer to ensure proper side laps for any pitch in
horizontal and verticle or curved surface, etc. complete
and as directed and spaecified by PMC / ARCHITECT /
a 480. do as per above item but for roofing monitors from
00 mm thick Sq. mt 650.00
b 56.0 do as per above item but for roofing monitors from
0 mm thick Rmt. 775.00
C MASONARY AND PLASTER WORK
28 5.09 Brick work using common burnt clay building bricks
having crushing strength not less than 35 kg/Sq. cm. in
foundations and plinth in cement mortar 1:5 (1 cement :5
fine sand) for conventional type bricks.
29 50.0 Extra rate over above item 37 Brick work using common
0 burnt clay building bricks having crushing strength not
less than 35 kg/Sq. cm. in cement mortar 1:6 (1 cement :6
fine sand) for superstructure upto floor three level height.
For conventional type bricks. (a) For Superstructure above
plinth level upto floor two level
(B) Conventional.
30 170. Extra rate over above item 37 and 38 Brick work in super
00 structure above floor two level over and above the above
item of brick work in superstructure (B) Conventional. Cmt. 4324.00
31 50.0 Half Brick masonary in common burnt clay building
0 bricks having crushing strength not less than 35 Kg/Sq.
Cm in Cement Mortar 1:4 (1-Cement : 4- Coarse Sand) in
superstructure above plinth level for any level and
(B) Conventional Bricks. Sq. mt 633.99
32 269 Providing and applying double coat waterproof cement
0.00 plaster (mala finish) on internal surfaces in two layers,
including surface preparation, mixing approved integral
waterproofing compound, curing, scaffolding, etc.
complete.First coat: 10–12 mm thick in CM 1:4 with
waterproofing compoundSecond coat: 6–8 mm thick in
CM 1:3 with waterproofing compound (mala
finish)Finished smooth and even, true to line and level. Sq. mt 366.12
33 156 Providing and applying 15–20 mm thick stucco plaster in
7.00 cement mortar (1:3 / 1:4) in two coats, including surface
preparation, scaffolding, finishing to the desired texture,
curing, and all leads & lifts complete as per specifications.
34 156 Providing 20 mm thick double coat mala / sandface
7.00 cement plaster on brick/ concrete work for plastering
comprising of base coat of 12 mm thick cement plaster in
cement mortar (1 Cement : 4 Coarse Sand) in rough
finishing and 8 mm thick top coat of cement mortar 1:2 (1
Cement : 2 Coarse Sand) finished with trowel including
scaffolding curing etc. complete. Sq. mt 394.02
35 150 Providing and fixing 23 cms wide chicken mesh jaali with
0.00 nails & then application of 15 mm plaster on R.C.C. &
Masonary joints as per directed of Engineer in Charge Sq. mt 210.00
D STRUCTURE STEEL AND ALLIED WORK
36 143 Providing, Fabricating, Transporting and Erecting in
10.00 position at all levels as per drawing welded / bolted /
riveted steel structures with field bolting / riveting /
welding / drilling whebever necessary and finally full
welde after completting erecting work, applying one coat
of rust remover one coat of anti - corrosive red oxide paint
or yellow zinc chromate and three or more coats of
approved make and shade flat / enamle / aluminium paint
to give even shade etc, as directed and specified with
necessary gusset plates, base plates, base plates, battened
plates, cleats, etc. complete as per design and as directed
and specified by PMC / ARCHITECT / ENGINEER. (a)
Gusset plates will be measured and actual and paid for.
(b) Weight of bolts , nuts, washers, rivets and welding will
not be considered and paid for.
(c) The measurements of rolled sections shall be taken in
length and area and the weight will be computed as per
standard steel tables, Rolling margin and wastage if any
will be to contractor's account.
(d) Rate includes for any Rectifications and minor works
to be carried out etc. cpmplete. Kg 126.68
37 280 Providing and fixing M.S. grills of required pattern to
0.00 wooden frames of windows etc. with M.S. flats at required
spacings and frame alround, square or round bars with
round headed bolts and nuts or by screws. (B)
ORNAMENTAL GRILL pattis, and all other visible
wooden pattis with melamine polish of approved brand
and procedure. KG 143.64
E PAVING AND FLOOR FINISH WORK
38 75.0 Providing and laying marble stone slab flooring over
0 20mm (average)base of cement mortar 1:6 (1-cement :
coarse sand) or L.M. 1:1.5(1- lime putty : 1.5 - coarse
sand) laid and jointed with gray cement slurry including
rubbing and polishing complete. (A) Marble slab 25mm
thick Sq. mt 2267.88
39 59.0 Providing and laying polished kota stone slab 25mm thick
0 in risers of steps,skirting Dedo and pillars laid on 10mm
thick cement mortar 1:3 (1-Cement : 3 coarse sand) and
jointed with gray cement slury mixed with pigment to
match the shade of slab including rubbing and polishing
etc. complete. Sq. mt 1214.30
40 120. Providing and laying Vitrified tiles 8 to 10 mm thick , 36''
00 x 36'' in flooring treads of steps and landing laid on a bed
of 12mm thick cement mortar 1:3 (1-cement : 3-coarse
sand ) finishing with flush pointing in white cement.
41 75.0 Providing and laying Vitrified tiles 8 to 10 mm thick , in
0 skrting risers of steps and dedo on 10mm thick cement
plaster 1:3 (1-cement : 3-coarse sand) and jointed with
white cement slurry Sq. mt 1103.06
42 110. Providing and laying broken china mosaic flooring for
00 terrace using 12 mm to 20 mm broken pieces of glazed
tiles to be laid over cement mortar 1:3 to plain or slope
and to be tempered to bring mortar creme out upto surface
using white cement including rounding off junctions and
extending them upto 15 cm along the wall,clearing with
water and oxalic acid etc. as directed. Sq. mt 771.98
43 50.0 Providing and laying white or golored glazed tiles of the
0 size 300 mm x 200 mm x 8 mm / 300 mm x 450 mm x
mm in skirting, risers of steps and dedo on 10 mm. thick
cement plaster 1:3 (1 cement : 3 coarse sand) & jointed
with white cement slurry.
44 910. Providing & fixing heritage cement / Athangudi tiles in
00 COMMUNITY HALL ,EVENT HALLS, MEETING
ROOMS including base preparation, polishing & sealing Sq. mt 2250.00
45 300. Providing & fixing heritage patterned vitrified tiles
00 (Moroccan/Jaipur design) in150mm border along with
kotah stone in PASSAGES AND FOYER AREA Sq. mt 2250.00
46 450. Providing and fixing Kota stone flooring of approved
00 green and brown shades in leather finish (machine
brushed anti-skid texture), 20–25 mm thick,laid over
mm thick cement mortar bed (1:4), including dressing of
edges,jointing with cement slurry mixed with matching
pigment, curing, and cleaning and sealing is complete.in Sq. mt 1750.00
PASSAGES AND FOYER AREA
47 377. Providing and Fixing 16 mm thick Kota stone skirting of
00 100 mm height with C.M. 1:4 (1 Cement:4 Sand) in good
line and level Rmt 180.00
48 40.0 Providing & fixing 15 mm thick kadappa stone riser in the
0 STAIRCASE including polishing Sq. mt 1250.00
49 80.0 Providing & fixing 15 mm thick Jaisalmer stone steps in
0 STAIRCASE including polishing Sq. mt 1800.00
50 110 8 mm thick Vitrified Skirting (100 mm height) matching
0.00 the flooring Rmt 350.00
51 120. Providing & laying 8 mm thick vitrified tile flooring
00 complete in male female toilet area Sq. mt 1350.00
52 240. Providing & fixing 8 mm thick vitrified tile skirting
00 mm height in male female toilet area Rmt 180.00
53 39.0 Providing and fixing 12 mm thick wooden flooring on
AND GREEN ROOMS Sq. mt 4262.00
54 90.0 Providing and laying integral cement based water
0 proofing treatment Average 120 mm thick including
preparation of surface as required for treatment of roof,
balconies, terraces etc. and making necessary vata at the
junction of Wall and floor wherever required as directed
by Engineer In Charge and consisting of following
operation .Applying and grouting a slurry coat of neat
cement using 2.75 kg/Sq.Mt. Of cement admixed with
proprietary water proofing compound conforming to IS
.2645 over the RCC slab including cleaning the surface
before treatment. Laying cement concrete using broken
bricks/brickbats25 mm to 100 mm size with 50% of
cement mortar 1:5 ( 1 cement , 5 coarse sand)admixed
with proprietary water proofing compound conforming to
IS 2645 over 20 mm thick layer of cement mortar of mix
1:5 After two days of proper curing applying a second
coat of cement slurry admixed with proprietary water
proofing compound confirming to IS 2645 Finishing the
surface with 20 mm thick jointles cement mortar mix 1:4
(1 cement, 4 coarse sand) admixed with proprietary
water proofing compound conforming to IS: 2645 and
finally finishing the surface with trowel with neat cement
slurry and making of The whole terrace so finished shall
be flooded with water for a minimum period of two weeks
for curing and for final test.all above operations to be
done in order and as directed and specified by Engineer -
In- charge Sq. mt 1890.00
55 110. Providing and laying cement concrete flooring 1:2:4 (1
00 Cement : 2 Sand : 4 graded stone aggregates 20 mm
nominal size) laid in one layer and finished with a floating
coat of neat cement (A) 50 mm thick.
56 110. Providing and layingbrick bat koba concrete for china
00 mosaic bedding Sq. mt 750.00
57 100. Providing and Laying of Rubber Moulded Paver Block
00 Grey/Coloured 60 mm thick, M-35 Grade of any size ;
shape (Usually Uni-Paver Blocks) using black trap good
quality aggragate of 20 mm nominal size for footpath,
parking areas, service lanes and other areas as mentioned
in the drawing / instruction of engineer in charge. Cost
includes formworks using rubber mould,providing and
laying paver blocks as per required grading and
specification. The paver block shall be mechanically
compacted. The work of paving blocks shall be executed
in line and level by skill mason of flooring work only. It
should be laid in such a way that the no cutting of the
paver block to be necessary. if cutting of paver block
necessary then it should be cut by machine only and
carting. The finished surface of the paver block shall have
resonably good, plain finished. Paver blocks shall be
compacted and shall be relaid if necessary. Gravel or such
type of materials shall not be allowed for production.
Laying on 5 cms thick sand bedding Sq. mt 501.60
58 100. Providing and fixing pre-cast concrete kerb stone of gray
00 cement based concrete block 30 cm length x 30 cm heigh
and 75 cms thick of M-200 grade concrete as per
approved design and including excavation for fixing in
proper line and level, filling the joints in C: M 1:3 (1
Cement : 3 Fine sand) etc. complete. Rmt 328.00
F PAINT AND POLISH WORK
59 180 Providing & Applying two coat of white putty of Birla or
0.00 equivalent at all levels to internal plaster surfaces/POP
surfaces of concrete, masonry work including jambs, sills,
grooves, pattas, rounding of corners after thoroughly
brushing the surfaces free from mortar dropping and other
foreign matter and also including preparing the surface
even and sand papered smooth etc. after applying every
coat of putty. Priming coat of alkali resistant cement
primer (water or solvent based) is to be applied before at
all levels, all floors, all height, all complete as per
drawing, specifications, instruction & directions of the
Engineer-in-charge. Payment shall be done as per
drawing/laid at site of plastered area. Approved Brands :
J.K. White, Birla, Asian.
60 100. Painting two coats (excluding priming coat) on new steel
00 and other metal surface with enamel paint, brushing,
interior to give an even shade including cleaning the
surface an even shade including cleaning the surface of all
dirt, dust and other foreign matter.
61 100. Painting one coat extra on new steel and other metal
00 surface with enamel paint, brushing, interior to give an
even shade including cleaning the surface an even shade
including cleaning the surface of all dirt, dust and other
foreign matter. Sq. mt 50.40
62 150 Painting two coats (excluding priming coat) on new wood
0.00 and other wood base surface with enamel paint, brushing,
interior to give an even shade including cleaning the
surface an even shade including cleaning the surface of all
dirt, dust and other foreign matter.
63 180 Wall painting (Two coats) with plastic emulsion paint of
0.00 approved brand and manufacture on undecorated wall
surface to give an even shade including thoroughly
brushing the surface free from mortar droppings and other
foreign matter and sand papered smooth.
64 180 Finishing wall with weather proof exterior emulsion paint
0.00 on wall surface (two coats) to give an required shape even
shade after thoroughly brushing the surface to remove all
dirt, and remains of loose powdered materials.etc
complete Sq. mt 113.40
65 15.0 Providing and fixing exterior grade teak wood
0 door/window frames made from well-seasoned timber
having a moisture content of 12–15%, including
machining, rebates, mortise-tenon joints, preservative
treatment to concealed surfaces, stainless steel holdfasts,
fixing in masonry, and finishing smooth complete as per 200000.0
drawings and specifications. Cmt. 0
66 10.0 Providing and fixing teak wood external door shutters
0 of approved thickness and design including styles, rails,
panels or glazing provision, waterproof adhesive joints,
machining, sanding, preparation for hardware and
application of approved exterior wood finish complete as
per drawings and specifications. 190000.0
67 6.50 Providing and fixing carved teak wood pillar / column
including base, shaft and capital as per architectural
drawings, complete with carving work, machining,
stainless steel anchoring arrangement, preservative
treatment, sanding and exterior protective coating. 211860.0
68 3.00 Providing and fixing decorative wooden brackets /
fascia made from seasoned hardwood including shaping,
joinery, anchoring to structural support, preservative
treatment and exterior finish complete as per architectural
details. Cmt. 0
69 50.0 Wooden handrail as per design for the staircase Made out
0 of hard wood (teak,sal)with pu polish Rmt. 6000.00
H CEILING AND GLASS WORK
70 195. Providing and fixing sheet glass, selected quality (Type-
00 C) bedded in putty and fixed with wooden beading,
including the cost of wooden beadings of first-class
teakwood and necessary cutting of glass. (2) 6 mm thick.
71 21.0 Providing and fixing glazed louvered glass windows and
0 ventilators with teak wood frame 10cm. x 7cm. size
including 3 coats of oil painting to wood work
etc.complete. Sq. mt 4102.54
72 550. Providing and fixing PVC printed false ceiling with flush
00 type with alluminium frame, frame work is done with
three different sections of G.I. sheet of 24 gauge thickness
named as C, U and L. The C section is fixed with hangers
at an equal distance of 36” each and then U section is
fixed perpendicular on C section with steel screws at and
equal distance of 16” each. The complete frame work is
supported by G.I. L angle/6 mm rod hangers from the roof
and L sections is fixed all around the wall as shown in the
diagram. 5mm PVC sheet strips of size 2 wide are fixd
with counter sunk steel screws on the U section. Further
3mm PVC sheet is stuck to these PVC strips with solvent
cement such that joining lines are perfectly matched. P.U.
putty is filled, dried and leveled and requisite coats of
primer and paint is done on the ceiling for getting fine
surface finish etc. complete as per direction of
Engineering and charge manufacturer’s specification and
drawing. Sq. mt 902.00
73 550. Providing and fixing wooden planks ceiling with tounged
00 and grooved jointing and wood screws (frame work and
cover fillings to be measured and laid for separately) (A)
Indian Teak wood (iii) 25mm thick
74 15.0 Providing and fixing M.S. Fan clamps type 1 to 16mm
0 dia M.S. bar bent to shape with hooked ends to R.C.C.
slabs curing, laying including painting the exposed portion
of loops, all as per standard design complete. Eac h
130.98 11011 11.21 Extra over rate of item 20 for
providing and fixing M.S. fan clamps type-II as per
standard design in R.C.C. beams during laying towards
additional height of the clamp due to beam rib. Cm Hei
ght 1.49 11012 11.23 Providing and fixing M.S. round
holding down or anchor bolts with nuts and washer plates
complete. Each 124.74
75 550. Providing and fixing wooden false ceiling including
00 framework, ceiling boards, suspension system, finishing
and all complete as per drawings and directions of
Engineer-in-Charge.Framework to be fixed true to line,
level and plumb. Grid spacing 600x600 mm. Boards fixed
with screws. Provide cut-outs for services. Framework:
Seasoned wooden battens 50x25 mm or GI sections.
Boards: 12 mm BWR/BWP plywood. Suspension: MS
rods 6–8 mm dia. Finish: Veneer/laminate/ PU polish.
Fasteners: SS/GI screws. Sq. mt 3140.00
I GFRP AND ROOFING WORK
76 68.0 Providing and fixing Glass Fiber Reinforced Polymer
0 (GFRP) elements of approved design, shape, size, and
pattern as per drawings and instructions of the Engineer-
in-Charge.The GFRP shall be manufactured using
isophthalic polyester/vinyl ester resin reinforced with E-
glass fiber, produced through hand lay-up or spray-up
process in approved moulds.The minimum thickness of
GFRP elements shall be 5 mm, unless otherwise
specified.The outer surface shall have a UV-resistant gel
coat finish, smooth or textured as per the approved
sample. The material shall be resistant to weathering,
moisture, and temperature variations.The GFRP panels
shall be fixed over MS structural framework (minimum
40x40x3 mm) anchored to the base structure using
approved anchor fasteners. Panels shall be fixed using SS
screws, rivets, or adhesive as required.All joints shall be
properly sealed using weatherproof silicone sealant.The
rate shall include:Cost of materials, labour, moulds
Transportation, loading/unloading Scaffolding and
installation All leads and lifts Finishing and cleaning.
Complete work shall be executed as per approved
drawings and sample, to the satisfaction of the Engineer-
in-Charge.Submittals Required Shop drawings Material
test certificate Sample panel (mock-up) Sq. mt 88275.00
77 550. Stone-coated roof tiles fixing over an aluminium sheet,
00 including accessories Sq. mt 3500.00
78 110 Providing & fixing aluminium roofing sheet 0.8 mm thick
0.00 with 50 mm thick rock wool insulation, including
fasteners, sealants, overlaps, flashing, complete Sq. mt 2600.00
79 121 Providing, Fabricating, Transporting and Erecting in
00.00 position at all levels as per drawing welded / bolted /
riveted steel structures with field bolting / riveting /
welding / drilling whebever necessary and finally full
welde after completting erecting work, applying one coat
of rust remover one coat of anti - corrosive red oxide paint
or yellow zinc chromate for MS truss including erection
80 385 Providing, Fabricating, Transporting and Erecting in
0.00 position at all levels as per drawing welded / bolted /
riveted steel structures with field bolting / riveting /
welding / drilling whebever necessary and finally full
welde after completting erecting work, applying one coat
of rust remover one coat of anti - corrosive red oxide paint
or yellow zinc chromate for Purlins
81 100. Providing and fixing GI/Aluminium gutters having section
00 400 mm wide and 150 mm deep with 0.50 mm thick sheet Rmt 800.00
82 28.0 P&F PVC Downpipes of 100 mm dia 4 Kgf/sqcm
83 120. Flashing & ridge caps
84 480. Providing, laying and fixing in position galvalume pre
00 painted and pre coated (PPGA) trapezoidal profile sheets
(size, shape and pitch of corrugation as approved by PMC
/ ARCHITECT / ENGINEER) with special male / female
side laps and anti siphoning feature at male and to prevent
leakage made from high tensile strength - 345mpa /
500mpa GALVALUME steel and AZ-150gsm Zincalume
coating to total on both side as per ASTM 1397 (55%
aluminium + 43.5% zinc and 1.5% silicon) having sheet
0.55mm TCT at top and base metal thickness 0.48/0.5mm
including colour coating of 20 micron finish coat over
micron primer coat on exposed side and back coat of
microns over a primer coat of 5 microns and having
protective gard film of 25 micrones to avoid stretches
while handling the sheet and upto erection process for
roofing and side
clading, approved make and approved shade, for roofing
at all levels and heights including cutting sheets and
drilling the holes with side laps as required and end laps
150mm to 200mm including fixing by self tapping and
self drilling 8 mm dia x
55mm long SDST screw of 'BUIDEX' or corroshield
make as per AS - 3566 class-3 with EPDM seal, washer of
25mm dia 3mm thick bitumen washer with
6mm central hole to form water proof joint etc. and using
templates as suggested by manufacturer to ensure proper
side laps for any pitch in horizontal and verticle or curved
surface, etc. complete and as directed and spaecified by
PMC / ARCHITECT / ENGINEER. for roofing 0.50 mm
thick Sq. mt 650.00
85 56.0 Do as per above item but for ridge about 500 mm wide
0 having 0.50 mm thickness Rmt 775.00
J PLUMBING AND SANITARY WORK
86 SITC (Supply,Installation,Testing & Commisioning)of C
PVC (SDR-11) water supply, comprising of necessary
fittings like ,elbows ,tees, unions, reducers, coupling , pipe
nipples etc.comp. confirming to relevant ASTM D
standards necessary brass threaded male / female adaptors
or elbows necessary clamps or hangers of approved make
and made out heavy FRP channel, Zinc Coated L clamp,
G.I U clamp covered with EPDM or Silicon rubber and
Anchor fasteners etc.comp Zari cutting with el.grinder &
finishing the same in wall or floor for concealing the pipe
line jointing materials like solvent cement along with
primer base of solvent of pipe and fitting supplier's
a 25.0 20 mm dia. (NB) pipe line
b 55.0 25 mm dia. (NB) pipe line
c 75.0 40 mm dia. (NB) pipe line
d 15.0 50 mm dia. (NB) pipe line
87 Providing and Fixing PVC SWR Pipes and Fittings,
solvent fix 6kg/cm2, confirming to IS4985 and IS7834
including all fixtures such as Couplers, Elbows, Tees,
a 24.0 40 mm dia. (OD) pipe line
b 191. 110 mm dia. (OD) pipe line
c 15.0 160 mm dia. (OD) pipe line
d 10.0 200 mm dia. (OD) pipe line
88 SITC of C PVC/U PVC Ball Valve for water supply pipe
line. comprising of Jointing materials like solvent cement
along with primer base of solvent of same company make
a 2.00 C PVC ball valve of Heavy duty confirming to relevant
ASTM D standards 40 mm dia. (NB) pipe line Nos. 1000.00
89 Providing and Fixing Eurpean Type W.C. of following
a 16.0 Providing and Fixing Concealed flush tank comprising of
Providing and Fixing Concealed flush tank with upper
plate (Jaquar cat.No.JCS-JCS-WHT-2400 and Plate
Cat.no.JCP-CHR-352415)
making necessary Brick masonry wall (approx.
1000x600*150mm thick) with single coat of plaster to
concealed the flush tank with chair bracket as per
architectural design
b 16.0 Providing and Fixing ewe wall mounting suite with proper
0 line, level (Jaquar cat.No.CNS-WHT-961SPP with seat
cover) Nos. 11000.00
c 16.0 Providing and fixing Health Faucet with one metre long
0 easy flex tube in chrome finish and wall flange(cat.No -
d 16.0 Providing and fixing toilet paper holder:C.P. brass( Cat
90 Providing and Fixing Washbasin of following make and
a 13.0 Providing and Fixing wash basin above counter type
0 comprising of. Nos. 12500.00
Providing and Fixing waste coupling and Bottle trap for
wash basin (Jaquar cat.No.FLS-WHT-5601)
Making Hole for waste coupling- Pillar Cock or basin
mixer on platform
Providing and Fixing waste coupling (Jaquar cat.No.ALD
Providing and Fixing bottle trap (Jaquar cat.No.ALD
b 13.0 Providing and Fixing Pillar Cock comprising of.
Providing and Fixing Pillar Cock (Jaquar cat.No.FLR-
Providing & Fixing necessary 450mm long Braided hose
with nut and washer of Jaquar make ALD-805B
c 13.0 Providing and fixing liquid soap container (Cat No- CAN-
d 13.0 Providing and fixing PTMT towel ring. (Cat No -CAN
Providing and fixing mirror of superior glass (of approved
quality) and of required shape and size with plastic
moulded frame of approved make and shade with 6 mm
thick hard board backing :
e 13.0 Rectangular shape (Cat No - AKP-35795)
91 Providing and Fixing Urinal of following make and model
a 12.0 Providing and Fixing Sensor type urinal flushing system
0 comprising of. Nos. 21300.00
Providing and fixing white vitreous china flat back or wall
corner type lipped front urinal basin (Cat No- URS-WHT-
Providing Sensor type Urinal flushing system of jaquar
make cat. No SNR-STL-51087
Fixing sensor type flushing system at proper location with
necessary concealed box fittings etc.
b 12.0 Providing and fixing Bottle Trap (Cat No- ALD
c 12.0 Providing and Fixing waste coupling (Jaquar cat.No.ALD
92 Providing and Fixing S.S. Kitchen Sink of following make
a 2.00 Providing and Fixing Stainless steel sink made out of
1mm thick Nirali make Popular Range, Large having
Bowl size 460 x 460 x 230 mm, comprising of. Nos. 8000.00
Providing & Fixing brackets
b 2.00 Providing and Fixing wall mounted sink cock with regular
swinging spout comprising of. Nos. 2600.00
Providing and Fixing wall mounted sink cock with regular
swinging spout (Jaquar cat.No.FLR-5347N)
Providing & Fixing necessary heavy C P flange &
extension nipple heavy of Viking or Eq.make with Teflon
c 2.00 Providing and Fixing Angle Cock comprising of. Nos. 1500.00
Providing and Fixing Angle Cock ( Jaquar cat.No.FLR-
Providing & Fixing necessary heavy C P flange &
extension nipple heavy of Viking or Eq.makewith Teflon
d 2.00 Providing and fixing Bottle Trap (Cat No- ALD
93 42.0 110x110mm dia.(OD) Deep Seal P trap having water Seal
0 not less than 50mm Nos. 680.00
94 Providing and Fixing Pumps & Pressure System
a 1.00 Submersible Twin Pump System using Grundfos Make
Openwell Submersible Pumps,
2 Pumpsets (1W + 1S),Each Motor Rating : 1.5kW (2
HP), Three PhaseSystem Rating : 3.0kW (4 HP), Three
PhaseEach Pump : Flow 122 LPM @ 39 Mtr. Delivery
HeadSystem : Flow 244 LPM @ 39 Mtr. Delivery Head
Scope of Supply:Horizontal Submersible Pumpsets -
Nos., Multi Pump Controller - 1 Nos., Float / Magnetic
Sensor - 2 Nos.incl. of Material Handling &
Commissioning Charges
Controller Features:One Working One Assist Operation
With Auto Cascading (Alternating Logic) of Pumps, Over
Load / Dry Run Protection, Digital Display, On - Off
Timer & Hooter Connection
b 1.00 Pressure Booster System Grundfos Make HYPN Booster
System - Single VFD
2 Pump + Motor sets (1W + 1S),
Each Motor Rating : 1.5 kW, Three Phase, IE 3 Efficiency
System Rating : 3.0 kW, Three Phase, IE 3 Efficiency
Each Pump : Flow 10 M3/hr @ 30 Mtr. Delivery Head
System : Flow 20 M3/hr @ 30 Mtr. Delivery Head
Pump M.O.C.: Base - CI, Impeller & Chamber - SS
Scope of Supply:
Pump with Motor - 2 Nos, Pressure Transmitter - 1 Nos,
Non Return Valve - 2 Nos, Isolating Valve - 4 Nos,
Pressure Gauge - 1 Nos, Base Frame (MOC : MS, CED
Coated) - 1 Nos, Suction and Discharge Manifolds (MOC
: MS, CED Coated) - 1 Nos, Single VFD Pump Controller
- 1 Nos, 100 Ltr. Pressure Tank – 1 Nos., Dry Runing
Protection Sensor for UG tank - 1 Nos.
95 6.00 Providing and fixing in position cowl vent to pipes. (B)
75 mm diameter. Nos. 450.00
96 6.00 Providing and fixing in position cowl vent to pipes. (C)
110 mm diameter. Nos. 600.00
97 10.0 Providing and fixing 12 mm dia C.P. bib cock of approved
0 make like jaquar or Essess or any other type and make
specified by the Architect. All pillar cocks, stop cock,
angle cock etc to be Jaquar or EssEss make with quarter
turn disc ceramic cartridge and chrome finish.
98 4.00 Providing and fixign S.W. gully trap with C.I. grating
brick masonary chamber and water tight C.I. cover with
frame of 300 mm x 300 mm size (inside) with standard
weight (i) Square mouth traps. (A) 100 mm x 100 mm size
P- Type. Nos. 1997.22
99 4.00 Constructing chamber of following size including
excavation, refilling, BBCC (1:5:10) for foundation,
Cement concrete channel(1:2:4) finished with 15 mm
thick cement plaster inside in cement mortar 1:3, finished
with cement slurry, brick masonary in C.M. 1:5 and
excluding the cost of chamber seat cover etc. complete.
(ii) for size 600 x 750 mm inside clear for depth
0.00 to 900 mm for pipe dia <= 200 mm diameter.
100 500 Construction of under ground tank with 23 cm thick
00.00 Masnory wall in c.m. 1:6 incl. Excavation, necessary
cm P.C.C. in 1:4:8 for foundation and providing R.C.C.
1:2:4 for top slab ( 150 mm thick & bottom slab (120 mm.
thick). Also having 100 mm. thick R.C.C.(1:2:4) paradi on
internal face of periphery walls. Rate includes all
necessary formwork, T.M.T. steel reinforcement as per
given design, vibrating,curing, & mixing of approved
water proofing material 1 Kg. of chemical with every
Kg.bag of cement ,inside plaster in C.M. 1:3 and vatta in
C.M.1:1 inside the tank. Providing and fixing F.R.C.
frame & cover of size 600 x 450 mm , F.R.P. steps etc.
comp as directed. This includes making Two tanks of
various capacities.
101 250 Construction of overhead tank with R.C.C. 1:2:4 pardi
00.00 and top slab Rate includes all necessary formwork, T.M.T.
steel reinforcement as per given design, vibrating,curing,
& mixing of approved water proofing material 1 Kg. of
chemical with every 50 Kg.bag of cement ,inside plaster
in C.M. 1:3 and vatta in C.M.1:1 inside the tank .
Providing and fixing F.R.C. frame & cover of size 600 x
F.R.P. steps etc. comp as directed. Litre 20.00
PART -C (ELECTRICAL ITEMS)
CHAPTER - I WIRING
SECTION - 1-2 Point wiring in Copper (MODULAR)
1 Point wiring for secondary light point with 2-1.5 sq.mm &
earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multistrand copper wires, in
following type of pipe to be erected concealed in / flushed on
wall/ceiling, complete with earth continuity and necessary
connection with primary light with accessories erected on
Metal / PVC box covered with 3 mm thick PC(Polycarbonet) /
Acrylic sheet for open / concealed wiring. with necessary
Lamp holder / ceiling rose / H.D.Connector as directed.
Note:- Maximum up to 6 mtrs length, excess will be considered
as Mains for Secondary Point.
163 (a) with medium class Rigid PVC pipe and accessories Pt. 131
2 Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire
of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multistrand copper wires, in following
type of pipe to be erected concealed in/ on surface on
wall/ceiling complete with 6A Modular type switch / bell push
& accessories and earth continuity of following type, erected
on PVC / Metallic box, single mounting base frame covered
with textured/metallic front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder/ceiling
rose / H.D.Connector as directed. 0
(a) with medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete 0
162 Cat. III Pt. 372
3 Point wiring for FAN with 2-1.5 sq.mm & earthwire of
sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS
PVC insulated multistrand copper wires, in following type of
pipe to be erected concealed in / flushed on wall/ceiling
complete with 6A Modular type switch and hum free EME four
or more step type electronic fan regulator with separately
mounted and accessories with earth continuity of following
type erected on PVC / Metallic box, single mounting base
frame covered with textured/metallic front plate modules
erected on / in wall / ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed. 0
(a) with medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete 0
60 Cat. III Pt. 632
4 Point wiring for Individual Plug with & earthwire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires, in following type of to be
erected concealed in / on surface of wall / ceiling complete with
Modular type switch & 5 pin Plug erected on PVC / Metallic
box covered with appropriate front plate modules erected on /
in wall / ceiling as per pipe erected with following type of
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire
from nearby switchboard/mcb db board 0
(a) with medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete 0
70 Cat. III Pt. 471
5 Point wiring for Looped Plug with 6A Modular type switch &
pin socket erected on PVC / Metallic box, single mounting base
frame covered with textured / metallic front plate modules
erected on / in wall / ceiling with following type accessories 0
79 Cat. III Pt. 255
6 Providing following type of Modular Type Accessories
mounted with pvc / metallic box, single mounting base frame
covered with textured / metallic front plate , modules erected
with necessary connection. As desired by Engineer In charge 0
(9) 16 Amp. SP one way switch 0
43 Cat.III Ea. 179
(10) 6/16Amp. Universal socket 0
43 Cat.III Ea. 198
Section :- 1- 3 / Conduits & Pipes 0
7 Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall or
ceiling erected with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with following dia of
pipes, in approved manner as directed 0
25 (a) 20 mm Mtr. 33
8 Providing & erecting PVC Corrugated Flexible Conduit with
required nos. of coupling, PVC bushes, Check-nuts etc.
complete of following sizes. 0
Section 1-4 Mains & Wires 0
9 Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm
copper conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size 0
(a) with medium class Rigid PVC pipe and accessories 0
1500 (b) 2 wire 2.5 sq. mm (From LDB to SB and SB) Mtr. 82
10 Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm copper conductor
FRLS PVC insulated stranded wire of green colour for earth
continuity of following size 0
. (a) with medium class Rigid PVC pipe and accessories 0
1000 (a) 2 wire 4 sqmm Mtr. 111
11 Providing & Erecting approved make following size of TV Co-
axial flexible cable comprising inner conductor of solid bare
copper insulated with Foam PE & Secondary conductor made
of poly - Aluminium film bonded Al. Braids @ suitable
coverage overall sheathed with black PVC insulation. 0
50 (c) RG - 6 CCS Mtr. 21
12 Supplying & erecting approved make Telephone Cable
electrolytic copper conductor PE insulation twisted in two
pairs, & wrapped with FRLS PVC tape & sheathed with
FRLS PVC or HFFR outer Jacket suitable for telephone wiring
& confirming to C-DOT erected in existing pipe. of following
size of conductors & nos.of pairs. With necessary connections. 0
[A] Conductor Size 0.5 mm 0
(a) Unarmoured 0
75 (2) Two Pairs Mtr. 20
LED LUMINARIES 0
Indoor LED Fittings 0
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with
diffuser with company mark/name 160V to 270V, Power
Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with
diffuser with company mark/name 160V to 270V, Power
Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
12 (i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet
28 Cat-lll Ea 164
(iii) 18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet
42 Cat-lll Ea 293
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/aluminium pressure die cast
powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/aluminium pressure die cast
powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount
Downlight with provision for spring loaded mounting clips
(i) 5-9 watts,Surge-2 KV
82 Cat-lll Ea 218
(ii) 11-15 watts, Surge-2 KV
14 Cat-lll Ea 423
(iii) 16-20 watts, Surge-2 KV
110 Cat-lll Ea 584
13 Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD <
10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency >
85 %.( fittings required LM-79 & LM-80 certificates)(NOTE:
Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)
(C) Post Top Lantern LED fitting comprises of finish cast
aluminum spigot and spun aluminum canopy fixed with opal
polycarbonate, pipe arrangement for vertical mounting driver
and accessories wired upto terminal block.IP
25 Cat-lll Ea 4052
(G) Step Light having Aluminium die cast and ABS Plastic
(i) 5 watts, Direct/Indirect luminaire
6-1 STREET LIGHTPOLES
Indoor LED Fittings
14 Supplying & erecting Galvanized M.S pipe post “B” class
mm O.D 4 mtr. Long duly painted with two coats of
aluminium paint complete with metallic base plate of 300 mm x
300 mm x 4mm thick for using as a compound light pole with
approx. weight 32 Kg.
15 Supplying & erecting approved make SMC press moulded
composite FRP. loop-in, loop-out approx. 2mm thick box
complete with Bakelite connector strip 5way(3P+N+E),DIN
rail for mounting mob & hinged doors as per requirement
having locking arrangements with mounting clamp with nuts,
bolts & washers suitable for erection on pole with cable
clamps& earth bolt of following size of box.
25 (B) 250mm x 200mm x 100mm [deep] Ea. 510
16 Providing 1:2:4 cement concrete foundation & 70 % PCC from
bottom including excavation for the pole of size 45 x 45 x
cm. Deep in below ground level with plinth of 45 cm x 45 cm
(or 45 cm dia x 45 cm) high upper ground level with necessary
curing and finishing in approved manner.
( for 4 & 6 mtr pole)
SWITCHGEARS & DISTRIBUTION BOARDS 0
Section 3-4 MOULDED CASE CIRCUIT BREAKERS 0
14 Providing and erecting Approved make Four pole moulded case
circuit breaker having breaking capacity ICU of 25 KA. at
V,having normal current rating up to 25 A to 100A. with Fixed
thermal & magnetic release suitable to work on A.C. supply
c/s. with all internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S. housing. 0
6 ICS=100% of ICU only Cat III Ea. 6112
17 Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 35 KA. at
415 V. having Normal current rating 200A.with variable
Thermal & magnetic release suitable to work on A.C.supply
c/s. with all internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S.housing 0
2 ICS=100% of ICU only Cat III Ea. 16061
Section 3-8 / PANEL MOUNTING BUSBARS 0
18 Supplying and erecting triple pole & neutral 440V / 500V panel
mounting Copper Busbars with four equal Nos. of electrolyte
bus having current density not more than 1.6 Amp. / sq.mm
(Rated current / cross section area) duly wrapped with colour
insulating tape for phase sequence of following current carrying
capacity, erected with necessary bus bar supports /insulators,
main cable socket to each bar, erected in existing cubical panel
with necessary connections. 0
14 (B) Suitable for 200 Amp. capacity Rn.Mtr 3171
12 (C) Suitable for 300 Amp. capacity Rn.Mtr 4861
SECTION 3-10 / MINIATURE CIRCUIT BREAKERS 0
19 providing and erecting Miniature circuit breaker single pole 6A
to 25A suitable to operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI Mark 0
110 Cat.III Ea. 111
20 Providing & erecting 240 V MCB double pole switch for motor
& inductive load (C Curve) having 10 KA breaking capacity
& confirms to IS : 8828 in existing box having following
21 Providing & erecting 415 V MCB Four Pole for Motor &
Inductive Load (C Curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following capacity 0
8 Cat III Ea. 662
12 Cat iii Ea. 730
22 Providing & erecting 415 V MCB three Pole for Motor &
Inductive Load (C Curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following capacity 0
(a) 6 to 32 Amp. 0
23 Supplying & erecting 20 Amp 10 KA ‘C Curve’ single
pole MCB with 20 Amp. Plug socket, company fabricated
powder coated sheet steel enclosure erected as directed with
[A] Metal Clad Socket with metal clad top 0
1 Cat.III Ea. 582
SECTION 3-11 MCB DISTRIBUTION BOARDS 0
24 5 Half / One Module Blanking Plate of Standard Size. Ea. 35
25 Supplying & erecting approved make RCCB + MCB (Electro
magnetic type only) working on residual current device having
10 KA short circuit breaking capacity and 30 mAmp.
Sensitivity & 30 mili sec. tripping time conforming to IS
test knob facility trip free mechanism operating for rated
leakage at nominal ten volt, complete erected including all
materials lugs screws etc. completed.
[e] 32A to 40 A, 4 Pole Three Phase
2 Cat. II Ea. 2145
[f] 63A, 4 pole Three Phase
6 Cat. II Ea. 2806
SECTION 3-14 EARTHING 0
26 Providing and erecting required size HOT deep Galvanised iron
strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel
20 board, Motors etc. using proper clamp. (25x3MM) Kg. 77
27 Providing and erecting Annealed bare Copper wire 8 to
28 Supplying & erecting in earthpit of minimum bore dia. 225mm
size ASH or approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free G.I.Pipes having Outer pipe dia of
mm having 80-200 Micron galvanising, Inner pipe dia of
mm having 200-250 Micron galvanising, connection terminal
dia of 14 mm with constant ohmic value surrounded by
highly conductive compound with high charge dissipation
suitable for following type of applications. 0
[C] For Electrical Installation covering Transformer Neutrals,
Lightning arrester Earthing, A.C.Plant & Sensitive
Computer System(like Automation, SCADA)i.e.
independent Earthing located in other than normal soil i.e.
Soft Rock, Marshy Soil etc..
-Length of Pipe : 3 Mtrs.
8 -Back filling Compound :2 nos Bags of 25 Kg. Ea. 10489
SECTION 3-16 CUPBOARDS. 0
29 Providing & erecting weather proof, dust & vermin proof, floor
mounted front operated indoor type cubical panel board
necessary IP-42 and above protection as per approval from
engineer incharge made from 14 SWG thick CRC M.S. sheet
for outer body & doors, 16 SWG thick CRC M.S.sheet for
internal partitions with necessary accesories , supporting
angles/ flats channel including cutting, bending, drilling,
welding, riveting with internal partitions & cable alley as per
requirements & instruction of engineer-in-charge with erection
supplied switch gears, BUSBARS, suitable size of inter
connecting PVC copper wire / copper-aluminium strips, rubber
grommets, rib, bakelite control fuses/MCB for measuring
instruments, earth bus & earth bolts, foundation flange - bolts-
base Plates, sufficient nos. of hinged doors, handles with
locking arrangement and rubber gasket,heavy duty end terminal
connection,danger notice board,necessary ventilation,earthing
strip complete. The Panel shall be painted with epoxy powder
(The rates excludes the cost of switchgears, bus bars, inter
connecting mains & Copper Aluminium strips, meters, Fuses
etc. The dimension shall be measured excluding base beams)
The panel shall be supplied with following approved
manufacturers with following size.
(A) locally fabricated panel board 0
45 (i) with 350 mm depth Sq.Mtr 10365
SECTION 4-3 / ARMOURED ALUMINIUM CABLES 0
30 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing trench / pipe of
following size of cables (VERIFY THE ACTUAL LENGTH
6 (A) 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core) Mtr. 182
SECTION 4-4 / ARMOURED COPPER CABLES
31 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Copper conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing trench / pipe at road
crossing or floor of following size of cable.
60 (A) 4 core 2.5 Sq. mm Mtr. 269
50 (B) 4 core 6 Sq. mm Mtr. 505
32 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Copper conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing trench / pipe at
road crossing or floor of following size of cables.
160 (A) 4 core 10 Sq. mm Mtr. 269
SECTION 4-5 MISCELLANEOUS.
33 Making trench in soft soil of suitable width of 90 cm deep for
laying cable or locating the fault all over the run and back
300 filling the same and making the surface as normal ground. mtr 55
34 Covering of cable with second class bricks or cement tiles laid
cover the cable crosswise & also on both sides with covering of
7. 5 Cm. layer of sand above & below cable (16 bricks per
375 meter) mtr 139
SECTION 4-6 / CABLE GLANDS.
35 Providing and, fixing heavy duty flange type brass cable gland
with rubber ring for PVC insulated armoured cable complete
with out going tails, insulating tape etc for following size of
16 (\B) 2 to 4 core 2.5 / 6 Sq. mm Ea. 38
52 (C) 2 to 4 core 10 Sq. mm Ea. 38
36 Providing and, fixing heavy duty flange type brass cable gland
with rubber ring for PVC insulated armoured cable complete
with out going tails, insulating tape etc for following size of
SECTION 4-7 CABLE LUGS.
37 Solderless crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner.
38 Solder less crimping type Copper lugs conforming to IS
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner.
CHAPTER - V Fans and Accessories
SECTION 5-1 / CEILING FANS AND ACCESSORIES
39 Providing & erecting Approved make Ceiling Fan with double
ball bearing ISI mark with Condenser 230 volt A.C.50 Hz
1200 mm sweep complete having 3 blades aluminium body and
blade sets having ornamental design shanks , canopy erected
with earthing. [ Make shall be approved by Engineer in
60 Charge] Ea. 2289
SECTION 5-2 FAN ACCESSORIES
40 Supplying and erecting 19 / 20 mm. nominal bore Medium
Class M.S. Pipe down rod erected duly painted for fan
60 complete with proper insulation without leakage and earthing. Mtr 107
41 Supplying & erecting Fan Hook of 10 mm M.S. Round bar
60 grouted in RCC slab with Making the site as original. Ea. 43
SECTION 6-7 TIME SWITCHES
42 Supplying & erecting approved make time switch with single
pole air break contacts suitable for 230 V.15/16A.complete
with self starting motor driven clock ‘ON’ &’ OFF’ automatic
arrangement at any predetermined time during each
hours,With nickel cadmium rechargeable battery backup
3 erected as directed. Ea. 2331
43 Supplying & erecting power contactor ,AC3 duty for time
switch complete erected as per direction Cat III
3 (D) 4 pole 440V 40 Amp. Ea. 2755
LIGHTNING ARRESTER
44 SITC of Vertical Air Termination Solid aluminium with Base-
10 mm dia and 1000 mm long. Air Termination Base tested for
conditioning, Ageing Test & Lightning impulse current
withstand test: 100 kA of 10/350µs waveform in an accredited
Third party laboratory as per 6.3 & 6.4 of IEC 62561-1
protocol with MAST 34mm dia 3000 mm long- Cold
2 Galvanized Each 11000
45 SITC of Galvanized Steel Flat 25x6 mm thickness from earth
electrode directly in ground as required. Zinc coating: 500 g/m
square (Approx:70 micron coating) tested and used exclusively
for lightning protection earthing system and ring equipotential
200 bonding. Mtr 153
MARKET RATE ITEMS:-
SUB PANEL & DISTRIBUTION BOARDS
46 Supply, installing, testing and commissioning of metallic
double door type distribution board with following MCBs /
ELMCBs / RCCBs / etc. with all necessary connections,
remaining blank area shall be covered with blanking (dummy)
plates etc. complete. (All DBs shall be installed concealed in
Non-Plant Bldg.) w.r.t Technical specification
Note All MCBs & MCCBs taken in SOR
47 4-WAY VTPN DB :
Incoming : 40 A FP RCBo-30mA
Outgoing : 6 to 32 A SP MCB (12 nos) (MCB TAKEN IN
2 ABOVE SOR) Ea. 12000
4-WAY VTPN DB :
Incoming : 63 A FP RCBo-30mA
Outgoing : 6 to 32 A SP MCB (12 nos) (MCB TAKEN IN
4 ABOVE SOR) Ea. 12000
4-WAY VTPN DB :
Incoming : 63 A FP MCB
Outgoing : 6 to 32 A SP MCB (12 nos) (MCB TAKEN IN
3 ABOVE SOR) Ea. 12000
6-WAY VTPN DB :
Incoming : 63 A FP RCBo-30mA
Outgoing : 6 to 32 A SP MCB (18nos) (MCB TAKEN IN
2 ABOVE SOR) Ea. 13500
6-WAY VTPN DB :
Incoming : 80 A FP MCB
Outgoing : 6 to 32 A SP MCB (18nos) (MCB TAKEN IN
1 ABOVE SOR) Ea. 13500
8 -WAY VTPN DB :
Incoming : 100 A FP MCCB
Outgoing : 6 to 32 A SP MCB (24 nos) (MCB TAKEN IN
1 ABOVE SOR) Ea. 15000
Incoming : 160 A FP MCCB
Outgoing : 63 A FP MCB (1 nos) (MCB TAKEN IN
Outgoing : 100 A FP MCB (1 nos) (MCB TAKEN IN
SUB PANEL SF PANEL 1 (BANQUET HALL 1)
Incoming : 160 A FP MCCB
Outgoing : 63 A FP MCB (1 nos) (MCB TAKEN IN
Outgoing : 100 A FP MCB (1 nos) (MCB TAKEN IN
SUB PANEL SF PANEL2 (BANQUET HALL 2)
Incoming : 80 A FP MCCB
Outgoing : 63 A FP MCB (1 nos) (MCB TAKEN IN
Outgoing : 40 A FP MCB (1 nos) (MCB TAKEN IN
SUB PANEL TF PANEL1 (GYMNASIUM)
Incoming : 80 A FP MCCB
Outgoing : 40 A FP MCB (2 nos) (MCB TAKEN IN
SUB PANEL TF PANEL2 (RESTAURANT)
Incoming : 80 A FP MCCB
Outgoing : 63 A FP MCB (1 nos) (MCB TAKEN IN
Outgoing : 40 A FP MCB (2 nos) (MCB TAKEN IN
48 Supply, installation, testing and commissioning of OUTDOOR
water tight fitting wall washer suitable for wall mounting with
29 12 W LED lamp complete Ea 900
49 Supply and Installation of High Volume Low Speed Fan
(HVLS) 12 feet Dia., 5 blades complete. With Motor, Control
2 Panel, Controller, Mounting arrangements etc. Ea 192500
50 Supply and Installation of High Volume Low Speed Fan
(HVLS) 10 feet Dia., 5 blades complete. With Motor, Control
4 Panel, Controller, Mounting arrangements etc. Ea 172500
PART-D ( FIRE FIGHTING ITEMS)
A FIRE HYDRANT SYSTEM
Providing, laying, jointing, testing and
commissioning of following sizes of pipes
conforming to IS-1239 and IS:3589, with all
accessories like all fittings (standard M.S.
fitting with welded joint shall be used on the
pipes) including tees, elbows, reducers, union,
flanges, rubber gaskets, GI nuts bolts,
washer including supporting/fixing the pipe
1.00 on floor / wall /ceiling with clamps, hangers
(using anchor fastners) as per specification.
All hangers, clamps, brackets etc. shall be of
galvanized iron unless specified otherwire and
then supply of the same shall also be included
for rates under this head.. Welding of any
kind on the galvanized support / hanger shall
not be permitted. Arc Welding procedure as
For wet riser System - M.S `C' Heavy class
pipe (For Hydrant ,)
Providing & fixing of Single Fire Hydrant
Valve, Single Outlet, SS-304, 63 mm female
inst. oblique type, 80 mm NB flange Inlet.,
200 mm OD, 160 mm PCD, 4 holes of
1.1 4 mm, complete with C.I wheel, PVC Blank Nos.
Cap and G.I Chain, Bearing IS:5290 mark,
Painted red. Including fixing with anchor
fastner and flanged tapping from wet riser
complete as required.
SITC of Air Release Valve For Fire Hydrant
Riser, 25 mm Male BSP
Threaded, GM, Nitrile Rubber Ball And
Sheet, Minimum 1,556.00
Operating Pressure 2 Kg/Cm2 with all
Providing & fixing swinging type ISI mark,
First Aid hose reel in red colour drum with
mts long and 20 mm dia heavy duty rubber
braided water hose , terminating with SS
coupling & nozzle of 6mm outlet with shut
1.3 4 off valve confirming to IS 8090 - 1976 Nos
complete with MS socket for tap-off, drum
and brackets (including painting) for fixing on
wall with anchor fastner, bolts & nuts
conforming to IS:884-1969 complete as
Providing and Fixing of Branchpipe,
short, Stainless Steel, 63mm male inst. inlet,
Fitted with male threaded outlet,20 mm bore
1.4 4 nozzle, Nos.
bearing IS:903 mark, suitable for inter
connection to hose pipe coupling
complete as required.
Providing and fixing Hose Box lockable
cabinet, made out of MS sheet of 16 gauge
thickness having central opening and 4 mm
thick glazed glass doors (Two nos.) suitably
marked on the outside with the letters "FIRE
HOSE" including necessary locking 1,905.00
arrangement and shall be painted with one
coat of primer and two coats of synthetic
enamel paint of approved shade.(External)
Size: 750 mm x 600 mm x 250 mm.
Providing & fixing of fire brigade connection
made from SS 304 (suction collecting head)
consisting of 4 Nos. 63 mm dia instantaneous
type male couplings with built-in check
1.60 1 valves, drain valve 1 No. 150 mm dia Nos.
butterfly valve, 150 mm dia. non return valve
with flanged outlet complete with bolts, nuts
and rubber insertions as required and as per
B SPRINKLER SYSTEM
Providing, laying, jointing, testing and
commissioning of following sizes of pipes
conforming to IS-1239 and IS:3589, with all
accessories like all fittings (standard M.S.
fitting with welded joint shall be used on the
pipes) including tees, elbows, reducers, union,
flanges, rubber gaskets, GI nuts bolts,
washer including supporting/fixing the pipe
2.0 on floor / wall /ceiling with clamps, hangers
(using anchor fastners) as per specification.
All hangers, clamps, brackets etc. shall be of
galvanized iron unless specified otherwire and
then supply of the same shall also be included
for rates under this head.. Welding of any
kind on the galvanized support / hanger shall
not be permitted. Arc Welding procedure as
For Sprinkler System - M.S `C' Heavy class
Supply Installation testing & comissioning of
UL / FM approved pendent / Upright type,
chrome plated / Brass finished sprinkler, Inlet
15 NB, 68 deg.with heat activated, Quick 360.00
Response type, K-115, with required
Providing and fixing of UL listed and FM
approved flexible hose
drop with required accessories and false 1,455.00
ceilling clamps.
Supply, installation, testing and
commissioning of vertical sprinkler Alarm
Valve With Motor Gong with all required
accessories like in built drain valve, test valve, -
gauge cock and pressure gauges etc. Sprinkler
alarm valve shall be FM approved.
Providing and fixing of inspector test and
drain assembly PN 16 with sight glasss, ball
valve, union, nipple etc. Test drain assembly 2,250.00
shall be comlete in all respect.
Providing and fixing of flange ended Y
strainer PN 16 with SS scrin of
mesh/sq.inch. Flange drilling standard shall be -
Providing and Fixing of hand lever operated
butter fly valve, PN: 1.6, with CI body and
S.G disc and other working parts as per IS:
13095 - 1991. With required accessories like -
matching flange, packings etc. complete as
a 0 50 mm dia Nos.
b 4 80 mm dia Nos.
c 2 100 mm dia Nos.
SITC electrically operated water flow
switches (Vane type) including tamper switch
and accessories, complete with tap off socket
arrangement as required, with potential free
contact with 2 Nos. NONC suitable to be 875.00
fixed directly on line of the foll. diameter of
pipes including cabling till alarm panel and all
other accessories to finish the installation.
Providing and fixing of Glycrin feeled burdon
type pressure guage, made from SS working
parts and SS casing, 150 mm dial and 0-21 kg
range with calibration certificate and Shall be 810.00
fitted with shut off valve and SS 304 syphon
tube and other required accessories.
SITC of 25mm dia Air Vent Valves with
2.90 3 mm dia. Ball valve and other required Nos.
accessories like nipple, socket etc.
SITC of pressure release valve with ball valve
and accessories 3,600.00
Providing and fixing of MS support with
required anchor fasteners, insert plate etc.
2.11 1000 with one coat of zinch chromate and two caot Kg
of black enemal paint. Support shall be
complete in all respect.
C PUMP HOUSE EQUIPMENTS
Supply, installation, testing and
commissioning of electrically driven high
3.00 1 pressure centrifugal fire hydrant & Sprinkler Set
pump suitable for automatic operation
consisting of the following:
Horizontal end suction / high pressure
centrifugal pump, suitable for operation on
415 volts ± 6%, 3 phase, 50 HZ A.C supply.
The installation shall be complete with
flexible coupling and coupling guard as
required. Fire pump shall have C.I. casing,
CS diffusers, bronze impeller (hard finished
and dynamically balanced) and S.S. (304)
Shaft with mechanical seal, capable for
delivering 2280 LPM at outlet head of 70 -
MWC to ensure a minimum pressure of
Kg/Sqcm at the farthest or topmost hydrant.
The installation shall be complete with
necessary pressure gauge with gun metal shut
off cock on delivery side. (The pump should
be tested for bench mark at factory and shall
be gotten approved by the Local fire
Pump shall be capable of furnishing not less
than 150% of rated capacity at a head of not
less than 65% of the rated head. The shut off -
head shall not exceed 120% of rated head.
b. Squirrel cage induction motor, TEFC type
suitable for operation on 415 volts, 3 phase
50 HZ A.C supply, for the above pump with
synchronous speed of 2900 RPM, conforming
to IP 55 protection & class F insulation. The -
motor shall conform to IS 325-1978 (up to
date) with flexible coupling and coupling
guard, complete as required.
Common base plate for (a) and (b) from
M.S. Channel for required size. -
Suitable cement concrete foundation with
cement concrete plaster (design and drawing
to be provided by the Contractor while the
foundation will be done by others) complete -
with anti-vibration arrangement of cushy foot
Supply, installation, testing and
commissioning of Diesel Engine driven fire
3.10 1 pump suitable for automatic operation Set
comprising of the following and conforming
to BS 649/IS 10002 all amended upto date.
Horizontal, End section, Back pullout
centrifugal pump, suitable for operation on
415 volts ± 6%, 3 phase, 50 HZ A.C supply.
The installation shall be complete with
flexible coupling and coupling guard as
required. Fire pump shall have C.I. casing,
CS diffusers, bronze impeller (hard
a finished and dynamically balanced) and
CS shaft with mechanical seal, capable for
delivering 2280 LPM at outlet head of
MWC minimum pressure of 3.5 Kg/Sqcm at
the farthest or topmost hydrant / sprinkler.
The installation shall be complete with
necessary pressure gauge with gun metal shut
off cock on delivery side.
Pump shall be capable of furnishing not less
than 150% of rated capacity at a head of not
less than 65% of the rated head. The shut off -
head shall not exceed 120% of rated head.
Heat exchanger cooled (secondary cooling)
diesel engine of speed 1800 RPM suitable for
the above pump with automatic starting
mechanism and other accessories including
fuel tank (fabricated from 3mm MS sheet,
painted with two coats of synthetic enamel
paint over a coat of primer) of capacity
adequate to sustain pump operation for
c hours continuous working. The tank shall be
fitted with Magnetic oil level indicator, MH
with cover, drain valve, air vent including
structural supports (painted with approved
shade), 1 Nos. x 12 volt battery, heat
exchanger with necessary piping connections
& fittings, flexible coupling, coupling guard
& exhaust pipe connection complete as
Diseal engine tank 200 ltr capacity minimum. -
Common base plate for (a) and (b) from
e M.S. channel of required size. -
Including Diesel Engine control panel with
Battery charger. -
Suitable cement concrete foundation with
plaster, (design and drawing to be provided by
g the Contractor while the foundation will be
done by others) complete with antivibration
arrangement of cushy foot mountings.
Supply, installation, testing and
commissioning of jockey pump
(pressurisation pump) comprising of the 2,01,000.00
Horizontal end suction centrifugal pump of
180 LPM with 70 Head, suitable for operation
on 415 volts ± 6%, 3 phase, 50 HZ A.C
The installation shall be complete with
Flexible coupling and coupling guard,
complete as required.
The pump casing shall be CI, shaft shall be SS
& impeller / shaft sleeve / casing wearing ring
shall be bronze. The pump shall be provided
with mechanical seal The system shall be
complete with necessary pressure gauge with -
gun metal shut off cock on delivery side. (The
pump should meet the condition and shall be
gotten approved by the Local fire Authority).
Squirrel cage induction motor TEFC type for
operation on 415 V, 3 phase 50 HZ AC
supply for the above pump with a
synchronous speed of 2900 R.P.M. with -
flexible coupling and coupling guard etc. as
Common base plate for (a) and (b) from
M.S. channel as required size. -
Suitable cement concrete foundation with
plaster, (design and drawing to be provided by
e the Contractor while the foundation will be
done by others) complete with Antivibration
arrangement of cushy foot mounting.
Providing & fixing pressure switch assembly
with isolation valve suitable for working
pressure of 10 bar. Cost shall be inclusive of
providing any short pieces, nipples, elbows
etc as required.
General specification of pressure switch
Encloser : Painted Mild Steel to IP:33 as per
IS:13947 (Part-1)
Sensing Element Phosphor Bronze Bellows 3,700.00
Switching : 1 SPDT Contact System
Switch Rating : 6A Inductive / 10A Resistive
240V AC, 0.2A Inductive
Repeatability / Accuracy : ± 2% FSR
Process Connection 1/4" BSP (F)
Cable Entry : Suitable for 6 to 14 mm dia
Supplying, installing, testing and
commissioning of C.I. Non-return valves as
3.40 per IS:5312 (Part I) 1984, swing check type
with required flanges, nuts, bolts and gaskets
etc. complete. (PN 16 Rated.)
a 2 150 mm dia Nos.
b 1 100 mm dia Nos.
Providing & fixing of flange ended rubber
expansion bellow joint of standard length as
3.50 per manufacturers specs including rubber
gaskets, flanges, nuts, bolts and washers
complete as required. (PN 16 Rated.)
a 8 150 mm dia Nos.
Supplying, installing and commissioning of
CO2 4.5 Kg Fire Extinguisher containing
99.95% Co2 Gas, fitted with discharge hose,
wall mounting bracket etc., ISI approved as 3,900.00
per IS:15683:2006 complete with Required
size of Zebra paintaing on wall and floor.
Supplying, installing and commissioning of
ABC 6 Kg Fire Extinguisher containing MAP
50, Stored Pressure Type, fitted with Pressure
Gauge, fitted with discharge hose, wall
mounting bracket etc., applicable on Class A, 1,450.00
B,C ISI approved as per IS:15683:2006
complete with Required size of Zebra
paintaing on wall and floor.
PART -E (HVAC ITEMS)
Appendix-1- (VRF AC System with Standard VRF Units )
1 Section 1: High Side Work
Supply & Installation of Outdoor condensing
units of the following capacity with R
Gas Based Model. (Bidder to offer nearest
size of Unit & suitable combinations available
with them & must consider piping derating for
Up to 40 KWr capacity Min EER 3.28 and
40 to 70 KWr capacity Min EER 3.26 and
Above 70 KWr capacity Min EER 3.02 and
First Floor : CKT 01 - 32 HP ( 16 HP + 16 HP
)- - Top Discharge
Second Floor : CKT 01 - 20 HP ( 20 HP )- -
Second Floor : CKT 02 - 12 HP - Side
Second Floor : CKT 03 - 10 HP - Side
Third Floor : CKT 01 - 10 HP - Side
Third Floor : CKT 02 - 12 HP - Side
Supply & Installation of VRF-indoor units of
1.02 the following capacity. (Bidder to offer
nearest size of Unit available with them)
Ceiling mounted 4 way Compact Cassette
Unit with condensate drain pump
Ceiling mounted 4 way Cassette Unit with
condensate drain pump.
1.03 Remote control Systems
Cordless remote controllers ( Operating
Mode:- On/Off/Fan Speed/Mode/Temp )
Ref-net joints for above VRF systems.
1.05 1 Outdoor unit branch kit Nos. 5000
2 Section 2: Low Side Work
Epoxy painted M.S. structure for supports and
For VRF system, all refrigerant piping
between indoor & outdoor units duly insulated
as per specifications. All piping inside the
room shall be properly supported with hanger
and exposed piping shall be properly
2.02 supported in GI Perforated tray. Exposed
piping insulation to be covered with 1 layer
of glass cloth and 2 layers of UV paint and
all the insulation joints must be covered
with EPDM Rubber Tape. (minimum
mm thick Class O Insulation)
2.02.01 For Folloing HP Ref Piping
2.02.01.02 50 20 HP VRF Piping CKT
2.02.01.03 100 32 HP VRF Piping CKT
Supply & Installation of Insulated uPVC drain
piping for all VRF Indoor AC units. (All the
Insulation joint must be covered with
aerotape.) ( min 9 mm thick)
Testing & Commissioning of VRF system
along with topping-up of refrigerant Gas.
2.04.01 4 10 / 12 HP VRF CKT Nos
2.04.02 1 20 HP VRF Piping CKT Nos
2.04.03 1 32 HP VRF Piping CKT Nos
2.05 Electrcial Work:-
All Cu armored power cable between
electrical panel & VRF ODU’s located on
2.05.01 Terrace. This cabling should be properly
supported in G.I Cable trays where-ever
2.05.01.01 0 06 Sq mm X 4 Core Copper Rmt
2.05.01.02 0 10 Sq mm X 4 Core Copper Rmt
2.05.01.03 0 16 Sq mm X 4 Core Copper Rmt
10 Sq mm Cu Single core wire for earthing
All control cables between indoor and
2.05.03 outdoor unit lay in PVC pipe and clamped.(for
2.05.03.01 600 1.5 Sq.mm 2 core Shielded Control Cable Rmt
1.6 mm thk G.I perforated cable trays with
2.06 necessary structural supports, anchor bolts,
etc. for the above work.
90 Deg ODU Exhaust Air Cowl with 18 G GI
& MS Frame Work & Safety Chicken Mess
Appendix-2- (LVL 0 Room Split AC )
1 Section 1: High Side Work
SITC of DX air-cooled Split AC unit
complete with Indoor / Outdoor units along
with cordless remote controller & aditional
charge of refrigerant. (R-410a / R32
Refrigerant)(Min. 3 Star & Cu Cond.)
1.01 (Without Ref Piping )
2 Section 2: Low Side Work
Supply, Fabrication and Erecting structure
steel for support. Applying two coats of zinc
chromate primer of ICI, Asain make/eq. , with
rubber gasket between support & duct / pipe
2.01 as per specifications and drawings and as
directed by the Engineer-in-Charge client
/consultant. Make : Tata / Sail / JSW as per
IS-2062 with TC. ( with 2 coats of approved
0 color epoxy paint ) Kg 0
For AC system, all refrigerant piping between
IDU & outdoor units duly insulated as per
specifications. All piping inside the room shall
be properly supported with hanger and
exposed piping shall be properly supported
with clamp.Exposed piping insulation to be
covered with 1 layer of glass cloth and
layers of UV paint and all the insulation joints
must be covered with EPDM Rubber Tape.
For 1.0 / 1.5 TR ( Min 1/4" (0.8mm thk) &
2.02.01 6 1/2" (0.8mm thk) with min 13 mm thk Rmt
Isulation) 1000
Supply & Installation of Insulated uPVC drain
piping for all Indoor AC units. (All the
Insulation joint must be covered with
2.03.01 6 For 19/25 mm dia piping Rmt
All Cu armored power cable / control cable
between IDU to ODU’s .
2.04.01 8 4 Core x 2.5 Sqmm Copper armored) Rmt
2.04.02 0 6 Core x 2.5 Sqmm Copper armored) Rmt
2.05 1 L type Wall Mounted Powder coated GI Satnd Nos 1000
Signage Sticker for each OUD with Room
Name (for Identification) 400
2.06 2 Chipping Work in Wall Rmt 150
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT- BUILDING PROJECT
Name of Work:CONSTRUCTION OF COMMUNITY BUILDING
AT T. P. S. No. 5 (City Wall Improvement) (Section – 7) Final Sanc., F. P. No. 26, At: Dariyapur -
Kazipur, Taluka: City, District: Ahmedabad, near dariyapurgate dariyapur ward central zone,
FINANCIAL BID (Online Only)
RECAPULATION SHEET
SR.NO. DESCRIPTION AMOUNT
1 EARTH WORKS & ALLIED WORKS
2 CONCRETE & ALLIED WORK
3 STRUCTURAL STEEL & ALLIED WORKS
4 ROOFING & ALLIED WORKS
5 MASONARY AND PLASTER WORK
12 AS PER MARKET RATE
13 TOTAL ELCRTICAL WORK
14 VRF AC SYSTEM WITH STANDARD VRF UNITS AND SPLIT AC
15 A. FIRE HYDRANT SYSTEM
16 B. SPRINKLER SYSTEM
17 C.PUMP HOUSE EQUIPMENT
I/We am/are willing to carry out work at ______% above / below (should be written in figures and
the estimated cost mentioned above.
Estimated cost put to tender :Rs.00000 Estimated cost put to tender :Rs.000000
Add_____% above : Rs ___________ Deduct_____% below : Rs __________
In words : Rupees
Signature of contractor Additional City Engineer (Central Zone )
Seal Ahmedabad Municipal Corporation