| 1 | L1₹20.2 CrAdmitted-Finance | ₹20.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹20.9 CrAdmitted-Finance KANNUR | KERALA | 670001 | ₹20.9 Cr | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY L2 | M/s.T.O.Ittoop & Associates L1 |
|---|---|---|---|---|---|
| 1.00NOTE: 1.For the same item, appearing under multiple subheads, bidders shall quote the same rate across all subheads. 2. If different rates are quoted for the same item, under different subheads, the lowest quoted rate for that item will be considered for all occurrences of that item in the BoQ while finalising the contract. | |||||
| 2.00HOSPITAL BLOCK Earthwork and Land development works | |||||
| 3.00 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 315.07 | cum | 379 ₹1.2 L | 400 ₹1.3 L |
| 4.00 | 2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock | 33.89 | cum | 685 ₹23,212.60 | 780 ₹26,431.86 |
| 5.00 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil | 1,624.76 | cum | 300 ₹4.9 L | 400 ₹6.5 L |
| 6.00 | 2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock | 180.53 | cum | 603 ₹1.1 L | 780 ₹1.4 L |
| 7.00 | 2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | 490.56 | cum | 126 ₹61,810.31 | 150 ₹73,583.70 |
| 8.00 | 2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock | 54.51 | cum | 228 ₹12,428.05 | 155 ₹8,448.90 |
| 9.00 | 60.2.2:Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete | 180 | hour | 532 ₹95,760 | 1,300 ₹2.3 L |
| 10.00 | 2.16.2:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 1.5 m but not exceeding 3 m | 799.2 | sqm | 1,826 ₹14.6 L | 270 ₹2.2 L |
Updated dates
Tender Value
₹19.1 Cr
EMD Value
₹5 L
Closing Date
21 Oct 2025, 3:00 pmClosed
Managing Director
KITCO Ltd, M M Gardens, Church Landing Road, Pallimukku, Ernakulam
Development of Taluk Head Quarters Hospital at Thaliparamba Kannur Civil Plumbing and Sanitary Electrical ELV System Fire Fighting Work HVAC Work and Elevator
2025_KITCO_802759_1
HFWD/KITCO/CL/03/2025-26
Open Tender
Civil Works - Buildings
540 days
Thaliparamba
As per Tender
8 documents required · 8 mandatory
₹17,700
Yes
₹5 L
Yes
KITCO Ltd
30 Dec 2025
26 Sept 2025
23 Oct 2025
26 Sept 2025
21 Oct 2025
3 Oct 2025
26 Sept 2025 - 29 Sept 2025
30 Sept 2025
Amount
HOSPITAL BLOCK Earthwork and Land development works
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
60.2.2:Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete
2.16.2:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 1.5 m but not exceeding 3 m
2.16.3:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 3 m but not exceeding 4.5 m
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2.33.1:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth
2.33.2:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth
2.33.3:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth
OD40163/2025-2026:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth within 5km to be levelled and neatly dressed. All kinds of soil
OD67144/2025-2026:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 5km and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock
Concrete Works
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
4.10: Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources).
OD40624/2025-2026:providing and applying a coat of residual petroleum bitumen grade of VG-10 of approved quality using 1.7kg per square meter on damp proof course after cleaning the surface with brushes and finally with piece of cloth lightly soaked in kerosene oil.
4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
RCC works
OD40842/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 350 kg/ cum. All Works up o plinth level
OD40864/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 350 kg/ cum.
5.38:Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.
OD42502/2025-2026:Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Masonry Works
50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
50.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
6.4.2:Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand)
OD116377/2025-2026:Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 200 mm thick with Grade- I AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately).
50.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
OD55188/2025-2026:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
6.15:Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.
6.5:Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.
Joinery Works
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.3:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
OD70527/2025-2026:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With toughened performance glass panes of 6.0 mm thickness with U-Value <=4.9 W/m²•K, SHGC <=0.44 and VLT 0.45
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
9.12:Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick (weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
OD64384/2025-2026:Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC/ Aluminium sliding windowwith necessary screws etc. complete.
9.161:Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/cum. The frame will have a provision of G.I. anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of Size 100x89x3mm for fixing of fire rated glazed shutter. The frame shall be finished with a approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge. (Cost of SS ball bearing hinges is excluded)
9.162:Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
9.164:Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 sqm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-Charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/ certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100 2200 mm (w x h) or 2.42 sqm
OD64395/2025-2026:Supplying And Fixing a pair of fire rated Solid SS Lever Handle and Mortise Lock case with Cylinder of approved size and quality for fire rated steel doors etc complete all works including all required fixtures as directed by Engineer in Charge.
9.139:Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.
OD64445/2025-2026:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):<br>With Toughened glass 12mm thickness
9.126.1:Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutters 25 mm to 40 mm thick.Marine plywood conformingto IS : 710
9.127.2:Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick
21.4.1:Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness
9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
9.21.1:Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
9.24.1:Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded ) (overall area of door shutter to be measured):Rectangular or square
9.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
10.27.1:Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 60 mm
10.27.3:Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10x120 mm
OD65162/2025-2026:Supplying And Fixing Glass to Glass SS lock for Frameless glass double door<br>with<br>60mm EPC -both side key , all complete as per approved drawings and as directed by Engineer in<br>charge at all levels.
9.84:Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
9.88:Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
9.97.3:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm
9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
9.122.2:Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.
OD65179/2025-2026:Providing and fixing a pair of back to back D type pull Handle of 25 mm Dia X 300 mm size ,mirror polished SS 304 grade with all fixtures and necessary ss screws etc. including cost and conveyance of all materials, labour charges, lead, lift etc complete as directed by the Engineer-in-Charge at all levels.
9.97.5:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm
9.77:Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete
OD65183/2025-2026:Providing and fixing of Wooden lead lined window with window frame shall be Singlerebate profile of size 120 x 70 mm (approx.) made out of Hardwood (Red Mirandi) with 2 mm Lead Sheet sandwitched in window frame. Frame shall be finished with primer finish .Window shall be fixed with 10 mm thickLead Glass . Lead lined wooden fixed window with size – 1.0 X 1.5 m . The inside face of the frame facetrim to rebate height shall be protected with minimum 2 mm thick lead line. Frames shall be provided withHRD Fasteners of Fischer Make or equivalent for installation on a finished plastered masonry/RCC wallopening. Installed frame shall be grouted with cement & sand slurry necessary for window on the clearmasonry opening. The rate shall includes the cost and conveyance of all materials , labour charges, lead,lift,Lead glass of 10 mm thick and HRDr fastener etc. complete as directed by the Engineer-in-Charge at all levels.
OD65187/2025-2026:Providing and fixing of Galvanized hollow lead lined metal door conforming to IS 277 (2003) . Door frame shall be double rebate profile of size 143 x 57 mm (approx.) made out of approx. 2.0mm (14 gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height shall be protected with minimum 2 mm thick lead line. All provision shall be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers shall be provided on the strike jamb. Frames shall be provided with back plate bracket and HLC fasteners for installation on a finished plastered masonry/RCC wall opening. Installed frame shall be grouted with cement & sand slurry necessary for doors on the clear masonry opening. Door leaf shall be approx. 48mm thick fully flush double skin door and Door leaf shall be manufactured from approx 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door shall be rigid with lead line of minimum 2 mm thick all across the inside of the exposed surface. In addition the door shall have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges shall be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. All doors and frames shall be finished to powder coated for minimum 50 microns of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Lead lined Steel Door Double leaf of size 2.00 X 2.40 m , the rate shall includes the cost and conveyance of all materials , labour charges, lead, lift, hardware like SS ball bearing hinges 100x75x3.0- 04 Nos.in each panel ,mortise dead lock with cylinder and both side key operation - 1 no , SS D type pull handle 300 X 25 mm - 1 set in each panel , heavy duty door closer- 1 no in each panel, Tower bolt 450 mm-1 no in each panel ,200x300mm size 10mm thick lead lined glass fixed using ceramic tape in each panel ,and HLC fastener etc. complete as directed by the Engineer-in-Charge at all levels.
OD65188/2025-2026:Providing and fixing of Galvanized hollow lead lined metal door conforming to IS 277 (2003) . Door frame shall be double rebate profile of size 143 x 57 mm (approx.) made out of approx. 2.0mm (14 gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height shall be protected with minimum 2 mm thick lead line. All provision shall be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers shall be provided on the strike jamb. Frames shall be provided with back plate bracket and HLC fasteners for installation on a finished plastered masonry/RCC wall opening. Installed frame shall be grouted with cement & sand slurry necessary for doors on the clear masonry opening. Door leaf shall be approx. 48mm thick fully flush double skin door and Door leaf shall be manufactured from approx 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door shall be rigid with lead line of minimum 2 mm thick all across the inside of the exposed surface. In addition the door shall have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges shall be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. All doors and frames shall be finished to powder coated for minimum 50 microns of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule.Lead lined Steel Door Single leaf of size 1.00 X 2.10 m , the rate shall includes the cost and conveyance of all materials , labour charges, lead, lift, hardware like SS ball bearing hinges 100x75x3.0- 04 Nos.in each panel ,mortise dead lock with cylinder and both side key operation - 1 no , SS D type pull handle 300 X 25 mm - 1 set in each panel ,heavy duty door closer- 1 no in each panel, Tower bolt 450 mm-1 no in each panel,200x300mm size 10mm thick lead lined glass fixed using ceramic tape in each panel and HLC fastener etc. complete as directed by the Engineer-in-Charge at all levels.
Steel Works
10.25.1:Item Shifted to Sub head 14 as item 14.73 , Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete.
10.25.2:Item Shifted to Sub head 14 as item 14.73, Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
10.16.3:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes
OD61516/2025-2026:Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge
10.17:Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
10.19:Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7:Providing and fixing ball bearing for rolling shutters.
Flooring works
OD116667/2025-2026:Providing and laying vitrified floor tiles in different sizes with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 x10mm
OD116720/2025-2026:Providing and laying vitrified floor tiles in different sizes with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 800x 800X10 mm
OD116730/2025-2026:Providing and laying Vitrified tiles indifferent sizes , with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600X10 mm
OD116758/2025-2026:Providing and laying Vitrified tiles indifferent sizes , with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 800 x 800 X10mm
8.2.2.2:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
8.5:Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
OD61765/2025-2026:Providing and laying Anti-skid Ceramic floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand),including pointing the joints with white cement and matching pigment etc., complete.
8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
OD65480/2025-2026:Providing and laying cement concrete flooring of mix M-25 with ready mixed concrete from batching plant. The concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by trowel floating etc. complete as per specifications and directions of Engineering-charge.
OD61809/2025-2026:Providing and laying top layer of 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
11.6.1:Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement18 mm thick
22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
22.23A:Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
22.22A:Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
OD62182/2025-2026:Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm(average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
8.9.1.2:Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.Granite of any colour and shade
OD61894/2025-2026:Providing edge bevelling to 18 mm (approx.) thick granite work etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.
16.89:Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi models location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
OD61911/2025-2026:Providing and fixing, Highly resistant 2 mm thick pressed homogeneous vinyl floor covering in rolls including skirting (T Group), with non-directional design, colour dyed as a raw mixture to ensure even colour throughout the thickness and a matt finish including self-levelling upto 3mm thick with cementitious material . Its surface is densely compacted for improved wear and ease of maintenance. It is suitable for very heavy traffic. It is treated with Evercare surface treatment, the latest improvement in polyurethane surface treatment obtained by UV laser cross linking process. Evercare avoids stain of chemical products used in healthcare like betadine, eosin or anti-bacterial hand gel which also increases the durability of the flooring that does not require wax for life. Do not require the application of any protective emulsion for life. Abrasion value according to EN 660.2 2.0 mm3, group T binder content type I, load resistance class 34/43, residual indentation 0.03mm. Fire classification Bfl-s1. After28 days the TVOC < 10g/m3 according to ISO 16000-6. REACH compliant. Floorscore certified. Weight 2750 g/m2. ISO717-2 Weighted improvement of impact sound insulation is 8db. Anti-Viral activity (human coronavirus 229E) – ISO 21702….99.7% (after 2h00). It incorporates bacteriostatic and fungistatic actions, tested for Anti-bacterial activity (ISO 22196>99% inhibit the growth of bacteria).The rate is inclusive of cost of all materials, upto 3 mm thick self-levelling, welding all joints, skirting, coving, capping, labour, lead, lift etc. complete as directed by the Engineer-in- Charge at all levels
22.4.1:Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)
Finishing works
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.85.3:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre
13.48A.1:Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.22:Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
OD61707/2025-2026:Polishing in high gloss/matt finish melamine clear polish on wood work in required<br>color/wooden shade texture with following process in the sequence as detailed below:<br>1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of<br>160/180 nos.<br>2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat<br>and 2nd coat is allowed to dry for 8 to 12 hrs.<br>3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to<br>remove excess sealer layer and make the surface further smooth after this wet rubbing, then<br>surface is applied with special grade melamine fillers to fill all the small and big holes/grooves<br>etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this<br>surface is further allowed to dry for 12 hrs.<br>4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and<br>melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry<br>surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final<br>melamine polish is applied with compressor pressure spray gun using melamine clear polish and<br>melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge.<br>(Final coat to be done in 1 or 2 layers without gap of time.)
OD61726/2025-2026:Supply and application of two coats of White cement based waterproof cement putty with visible water repellancy, very high anti-efflorescence and excellent finish, to make even and smooth finish after pre wetting substrate. Sanding of applied waterproof Putty Surface with emry paper / sand paper above 280 /320. Application of 1/2 coats of Silicon based Seal-O-Prime or approved equivalent (IGBC/GRIHA certifed best quality primer) with sealer properties having anti-algae and alkali resistance properties & damp resistance with 40% dilution with potable water. Application of 3 coats of water based PU with minimum VOC and very less odor having better sheen, finish and film integrity along with anti-algae, antifungal, anti-micro bial and high washable with high stain resiatance should comes under clean room coating requirements.Surface shall be Inspected to check ideal moisture level and pH value of the surface before painting. Surface Prepration with dust removal and sand papering with hand held sanding machine for repainting surface and scrapping new substarte with metal plate called paint scrapper to make smooth and ideal surface for painting .The rate shall include cost and conveyance of all material ,labour charges, lead etc. complete as directed by Engineer - in- charge. (All works covered by this specification shall be carried by an experienced agency having sufficient experience in this type of painting system Only skilled and experienced persons shall be employed for this purpose.)
False ceiling and miscellaneous works
12.52.1:Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending
12.45.3:Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
26.22.1:Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge.With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles.
12.52.3:Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit.
50.12.2.5:Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm)
12.7.1:Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2
OD105588/2025-2026:Supplying and laying floor mat 3M 7150 Nomad Loop Heavy duty or equivalent for Removal of dry heavy dust & loose sand particles by wiping action for removal of dry heavy dust & loose sand particles by wiping action etc complete all as per directions Engineer in charge at all levels
Retaining wall
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
OD61638/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account) All work upto plinth level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
OD61652/2025-2026:Supplying and laying good quality filter media (coarse aggregates of varying sizes from 53mm to 90 micron) brought from outside including cost of all materials, labour charges, transportation, loading, unloading ,taxes etc complete as directed by the Engineer- in -charge. The work has to be executed as per detailed specifications, and or as approved by Engineer - in - Charge.
OD61671/2025-2026:PVC WEEP HOLES- Providing weep holes using 50mm dia. PVC pipes working pressure 6kg /sq.cm and covering ends with nylon mesh including cost of materials, conveyance, labour charges etc. complete.
Road work
16.69:Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
16.78.1:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30
16.79:Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.
16.91.1:Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Electrical Foundations
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
OD61615/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account) All work upto plinth level
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
SUMP AND PUMP ROOM
Earthwork
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
OD56862/2025-2026:Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge
Cement concrete works
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
RCC work
5.33.1.2:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All work upto plinth levelConcrete of M30 grade with minimum cement content of 350 kg /cum
OD56094/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- .Concrete of M30 grade with minimum cement content of 350 kg /cum
OD55865/2025-2026:Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
Masonry work
50.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
Joinery works
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Steel work
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7:Providing and fixing ball bearing for rolling shutters.
10.25.1:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
Finishing works
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
11.6.1:Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement18 mm thick
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.85.3:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre
Waterproofing works
22.22A:Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
22.23A:Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
22.4.1:Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)
16.3.3:Supplying and stacking at site.53 mm to 22.4 mm size stone aggregate
23.6:Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge
23.7:Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.
HOLDING TANK
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
OD61254/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 350 kg/ cum. All Works up o plinth level
5.12:Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
OD61264/2025-2026:Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge.
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
22.26:Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
19.16:Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design.
ELECTRICAL WORKS
HT EQUIPMENTS and RISING MAINS
3.1.1:Supplying, installing on wall, testing and commissioning of following capacity rising mains made of 1.6mm thick IP 42 sheet steel enclosure duly painted with powder coating, wall straps, fully PVC insulated 4 Nos aluminium bus bars having current density of 130 AI sq. em at nominal current rating in convenient sections and suitable for 415 V, 3 phase, 4 wire, 50 Hz, A.C. supply with extension joints, fire proof barriers, expansion joints, thrust pads including jointing, and earthing with 2 runs of galvanised iron strips etc. as required. (Rising mains confirming to IS 8623, TEC 439)200 A (lsc=15 kA for 1 second)
3.2.2:Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.32 amps TPN
3.2.3:Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.63 amps TPN
3.2.4:Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.100 amps TPN
3.4.1:Supplying, installing, testing and commissioning of following capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses, mounting stands, cable end box, brass compression gland, connections, earthing etc. as required.200 amps TPN
OD68882/2025-2026:250 Kva OUTDOOR USS Design, fabrication, Supply, installation, testing and commissioning of outdoor type Unitized Substation. HT Chamber: 630A 26.2 kA 11kV Load break switch with earth switch, incoming suitable for XLPE cable, with HT suitable HRC fuses, and output connected to 11KV seal off bushings to the transformer Transformer compartment: 250 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Copper wound, Cast resin, Class F insulation Outdoor Transformer with enclosure, winding temperature alarm and master trip relays as per SLD and technical specifications. Losses shall be as per ECBC guidelines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 5% to -10% in steps of 2.5%. The transformer shall have suitable enclosure for providing neutral CT of 100/5A 15VA 5P10 on earthed star point with connector for connecting Earth Fault relay in LT side as per SLD. LV chamber: 400A FP TM based MCCB, chamber shall be suitable for terminating of 2Rx 300 sq.mm XLPE Al. cable, Earth fault relay, complete with all standard fittings and accessories etc. including necessary louvers. Item shall include all necessary control cabling for alarm, tripping & indication, relay, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, and necessary civil works, civil foundation (not included) etc. complete as per single line diagram & technical specifications in all respects as required.
OD68881/2025-2026:11kV RMU panel (Extensible Type) - Design, Fabrication, Supply, Installation Testing and Commissioning of 11KV electrically Operated 21kA for 3 sec, 630A SF6 Insulated, Ring Main Unit outdoor type (IP-54) with 1 nos motorized VCB as incomer and 2 no motorized VCB (fully rated earth switch) with fully encapsulated vacuum interrupter panel as outgoings, 630 Amp continuously rated Cu busbar complete with all accessories, protective relays, indicators, battery and battery charger, Manometer for indicating SF6 gas pressure with green zone marked on the scale, provision for padlocking for open, close, earth and test position etc. on existing foundation. The RMU shall have FRTU panel integrated with RMU completely wired along with Modem suitable for communicating in CDMA/GSM network and also have the facility to communicate with main SCADA room. The FRTU shall include all hardware, software and firmware necessary to meet the input/output (I/O) point requirement including input output cards and output relays. FRTU shall include on/off device control points to support control actions initiated from the SCADA. FRTU shall be powered by a 24V DC system with necessary protection. The RMU must be both side extensible type .The rate quoted shall be inclusive mounting accessories, hoisting to its location, assembling of units, lining up, bolting the units and checking all control wiring complete as per single line diagram & technical specification.
3.1.2:Supplying, installing on wall, testing and commissioning of following capacity rising mains made of 1.6mm thick IP 42 sheet steel enclosure duly painted with powder coating, wall straps, fully PVC insulated 4 Nos aluminium bus bars having current density of 130 AI sq. em at nominal current rating in convenient sections and suitable for 415 V, 3 phase, 4 wire, 50 Hz, A.C. supply with extension joints, fire proof barriers, expansion joints, thrust pads including jointing, and earthing with 2 runs of galvanised iron strips etc. as required. (Rising mains confirming to IS 8623, TEC 439)300 A (lsc=20 kA for 1 second)
HT CABLES
8.1.2:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm
8.3.2:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm
OD68891/2025-2026:Supply of 3C X 300sq.mm(E) XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date.
10.1.4: Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials for following size of 3 core, XLPE Aluminium conductor cable of 11KV grade as required:300 sq.mm
10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
DG & ACCESSORIES
OD68927/2025-2026:EXHAUST PIPES; Supplying and fixing the following size exhaust gas piping of suitable dia, welded black M.S, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool 50 mm thick wire mesh & 0.63mm aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drainplug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building within 16mradius of the exhaust. Sizing shall be based on the backpressure calculation furnished by the OEMand shall be approved by EIC. 4 inch dia exhaust pipe
OD68941/2025-2026:DG Set - 320 KVA Supply, Installation, Testing and Commissioning of 320 kVA prime rated D.G Set with acoustic enclosure and Control panel including reverse power relay, protection and digital metering, controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including anti vibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 320 kVA prime rating, brushless, self-excited, self-regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery.
UPS AND ACCESSORIES
OD68948/2025-2026:Supply, Installation, Testing and Commissioning of 50 kVA module rating UPS in N+1 arrangement, three phase input, three phase output, true on-line modular UPS system with 15 minutes back up at unity pf, including all required accessories, SMF batteries VRLA type with powder coated CRCA cabinet including cabling etc. as required complete having following specification. The UPS system shall be with multiple units of modular UPS (with a combination to maintain N+1 configuration with a total rating of minimum 75 kVA) and must have a minimum N+1 Frame for mounting UPS modules with hots swappable. The set of battery bank shall be mounted in battery racks. Fully digital controlled based on DSP with DPA architects (Each Modules should have Inverter, rectifier, charges, static bypass etc) Output shall be pure sine wave, power factor 0.95. Full time output voltage & frequency regulation. Auto regulation of battery end voltage Intelligent interface with LED/LCD display switch for manual bypass, auto temperature compensation etc. as required. true on-line UPS system with THD <1% in nonlinear load, and 97% efficiency at 50- 75% load, compliance to IEC 62040-1 for general Safety, compliance to IEC 62040-2 for Electromagnetic Compatibility, IEC620403 for Performance, IEC620404 for Environmental compatibility, including all accessories, as per the detailed technical specifications. ( The system shall be complete with battery rack, isolator and interconnecting cables
LT PANEL BOARDS
OD68961/2025-2026:APFC PANEL-100 kVAR: Supply, Installation, Testing & Commissioning of fully type tested design verified 415V, 50Hz, LT switchboard conforming to IEC 61439 Part 1&2 fabricated from ASTA/ ASEFA/ DECRA/ UL/ KEMA/ LOVAG certifde vendors and who shall be authorized panel fabricators of approved makes of OEMs. The type, size and manufacturing of enclosure shall be same as is for the design verified panel. The panel shall be free standing with floor mounting base and required base frame, mounting bracket etc shall be supplied and panel shall be with following switchgears, metering instruments and accessories etc. as per drawing & specifications. as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 3B. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker (the design calculation for the mechanical strength of busbar supports, spacing between supports temperature rise etc shall be furnished). The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire. Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top/bottom Cable entry. Incomer - 250A, 25kA, FP Moulded Case Circuit Breaker with thermal-magnetic release (Ics =100%Icu= 25KA).-1no IPFCR as per SLD and specification. Instruments and meters: 4 A control MCB, Ammeters, Multifunction Meters (kVAR required), Indication Lamps, CTs, IPFC Relay as per SLD . Busbar 250A, 25kA TPN busbar chamber with Aluminium busbar. Outgoings: 63A, 25kA, TP MCCB with thermal magnetic release with OL & SC protection -3nos 32A, 25kA, TP MCCB with thermal magnetic release with OL & SC protection - 4nos. 25kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) 3 Nos. 10kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) - 2Nos 5kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) - 1Nos 25 kVAr,480 V,50 Hz heavy duty capacitor(MPP-H) with 7 % Series reactor - 3No 10 kVAr,480 V,50 Hz heavy duty capacitor(MPP-H) with 7 % Series reactor - 2Nos 5 kVAr,480 V,50 Hz heavy duty capacitor(MPP-H) with 7 % Series reactor - 1Nos
OD68974/2025-2026:MSB: Supply, Installation, Testing & Commissioning of fully type tested design verified 415V, 50Hz, LT switchboard conforming to IEC 61439 Part 1&2 fabricated from ASTA/ ASEFA/ DECRA/ UL/LOVAG/ KEMA-certified vendors and who shall be authorised panel fabricators of approved makes of OEMs. The type, size and manufacturing of the enclosure shall be the same as is for the design-verified panel.The panel shall be free standing with floor mounting base and required base frame, mounting bracket etc. The panel shall be with the following switchgears, metering instruments and accessoriesetc. as per SLD & specifications, as required to complete installation. The IP rating shall be 42 or better and the form of construction shall be form 3b or better. The short circuit rating shall be suitable to withstand the SC rating of the incomer breaker (the design calculation for the mechanical strength of busbar supports, spacing between supports, temperature rise etc. shall be furnished). The enclosure shall be powder-coated after the 7-tank process. The control wiring for the voltage circuit shall be with 1.5 sq. mm and for current circuits with 2.5 sq. mm HFFR wire. Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top/bottom Cable entry as per the requirement. Incomer:500A, 25kA, FP Moulded Case Circuit Breaker with microprocessor-based release, Ics =100% Icu= 25KA). -1 no, 400A, 25kA, FP Moulded Case Circuit Breaker with microprocessor-based release (Ics =100% Icu= 25KA). -1 no, 500A, 25kA, FP ATS with AMF relay -1 noBusbar: 500 A, 25kA TPN Al BusbarMeters and instruments:4A control MCB, Multifunction Meter, indication Lamps, ON/OFF/TRIP indication lamps, CTs, Outgoings-250A, 25kA, TP+NL, MCCB with thermal-magnetic release and neutral link Ics = 100% Icu = 25kA) - 4 nos.100A, 25kA, TP+NL, MCCB with thermal-magnetic release and neutral link ( Ics = 100% Icu = 25kA) 1 nos,125A, 25kA, TP+NL, MCCB with thermal-magnetic release and neutral link (Ics = 100% Icu = 25kA) - 2 nos, 200A, 25kA, TP+NL, MCCB with thermal-magnetic release and neutral link ( Ics = 100% Icu = 25kA) - 1 nos, 160A FP MCCB Isolator-1 No SPD : Type-(1+2) -1 no
OD69011/2025-2026:Supply installation, testing and commissioning of EC charger of single phase upto 7.4kW, Mode 3 charging , level 2 and type 2 socket with or without shutter of suitable size cable length up to 5m that can be wrapped around the charger, single phase/32A with inbuilt revenue grade energy meter of Class B (+/- 1%)MID certification on display variants only having mobile communication with nano SIM socket of EU: GSM4G LTE, WCDMA, communication protocol OCPP 1.6, including minimum 2 years’ warranty, LED indication with RFID, Bluetooth, Ethernet(RJ45)Bluetooth, RS 485,WIFI 3G/4G Connectivity. Suitable size weather proof IP54,IK10 (IK8+ for operating temperature from -35 to -30 degree celcius)enclosure (powder coated) for wall or floor mounting EV chargers, Type A 40A, MCB+100mA AC RCCB & 6mA DC and all necessary accessories including civil works.
OD69015/2025-2026:Supply installation, testing and commissioning of EC charger For 2-Wheeler with Smart AC outlet of power rating 3.3*3 kw max(3 shot), Rated current 40 A max with energy monitoring system Including minimum 2 years’ warranty, Suitable size weather proof IP54,IK10 (IK8+ for operating temperature from -35 to -30 degree celcius)enclosure (powder coated) for wall or floor mounting EV chargers, All necessary accessories including civil works, suitable rating 100mA RCCB and MCB protections shall be provided.
LT CABLES AND CABLING
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
9.1.7:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.12:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 70 sq. mm (35mm)
9.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
9.1.30:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.35:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
90.12.1.34:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 185 sq mm
90.12.1.36:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 300 sq mm
90.12.2.34:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 185 sq mm
90.12.2.36:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 300 sq mm
90.12.7.35:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm
90.12.2.43:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)4 core 35 sq mm
90.12.5.34:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm
90.12.5.36:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 300 sq mm
90.12.7.19:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 70 sq mm
90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
90.12.7.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
90.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
90.12.7.36:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm
90.12.7.43:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp
90.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
90.12.7.14:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.37.7:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 10 sq mm
90.12.41.5:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp
90.12.41.31:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
OD69023/2025-2026:Supply and drawing the following sizes of PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 1 core 25 sq mm
OD69028/2025-2026:Supplying and making end termination with brass compression gland and copper lugs for following 4C 2.5 Sq.mm Cu size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.
OD69100/2025-2026:Supplying and making end termination with brass compression gland and copper lugs for following 3C 4 Sq.mm Cu size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.
7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
OD69164/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
OD69167/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
OD69168/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 450 mm width X 50 mm depth X 2 mm thickness
OD69367/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
OD69366/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
OD69365/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
OD69369/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
OD69379/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness.
OD69378/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
OD69377/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
OD69376/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
OD69375/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
OD69374/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
OD69373/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
OD69372/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 50 mm dia
14.13.3:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia
OD69394/2025-2026:Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 m below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal)
OD69121/2025-2026:Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4C 4 Cu
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
OD69123/2025-2026:Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required
9.1.3:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm)
90.12.1.4:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 16 sq mm
90.12.1.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm
90.12.2.4:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)2 core 16 sq mm
90.12.7.4:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 16 sq mm with factory made clamp
WIRING AND ACCESSORIES
15.1:Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
1.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
OD69410/2025-2026:Supply & fixing Computer points with 3 nos of 3 pin 5/6A socket with 2no. of 5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)
OD69413/2025-2026:Supplying and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, in existing GI box with interconnections as required a required.
MCB AND DISTRBUTION BOARDS
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.16:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.18:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.20:Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.23.4:Supplying and fixing Cable End Boxes (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with testing and commissioning etc. as required. For 14 way, Double door SPN MCBDB
2.24.1:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB
2.24.2:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB
2.25:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
OD69430/2025-2026:Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Four pole
OD69431/2025-2026:Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
OD70138/2025-2026:Supply and fixing of following 6-32A DP MCB, D-Curve rating, 10 KA, Miniature Circuit Breakers as required
OD69446/2025-2026:Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, "D" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD69447/2025-2026:Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "D" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Tripple pole
OD69454/2025-2026:Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Four pole
OD69457/2025-2026:Supply, Installation, Testing & Commissioning of following isolator in metal enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete. 25A/32A FP
OD69458/2025-2026:Supply, Installation, Testing & Commissioning of following isolator in metal enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.40A FP
OD69460/2025-2026:Supply, Installation, Testing & Commissioning of following isolator in metal enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.63A FP
OD70153/2025-2026:Supply and fixing of following 6-32A DP MCB, C-Curve rating, 10 KA, Miniature Circuit Breakers as required
OD70159/2025-2026:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 12 way (8+36) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
OD70162/2025-2026:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For VTPNDB with MCCB incomer
OD70164/2025-2026:Supplying and fixing following rating, 25 A four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
OD70165/2025-2026:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A FP 100mA
OD70166/2025-2026:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A FP 100mA RCCB
OD70167/2025-2026:Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 6A to 32A ,TP D curve
OD69619/2025-2026:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125Amp,25KA,FPMCCB
OD69620/2025-2026:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100Amp,25KA,FPMCCB
90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor
90.14.28.6:S & F Motor starters of the following ratingsFully automatic star delta starter for 15HP motor
90.14.29.2:S & F Motor starters accessories of the followingAuxiliary contact block 1 NO + 1 NC for starters
90.14.29.3:S & F Motor starters accessories of the followingPush button station for starters
OD70168/2025-2026:Supply, Installation, Testing & Commissioning of 100A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.
OD69628/2025-2026:Supply, Installation, Testing & Commissioning of 25A FP isolator in IP 65 weatherproof enclosure ,duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete
OD70170/2025-2026:Supply, Installation, Testing & Commissioning of 40A FP isolator in IP 65 weatherproof enclosure, duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete
OD70171/2025-2026:Supply, Installation, Testing & Commissioning of 25/32 A DP isolator in IP 65 weatherproof enclosure, duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete
LIGHT FIXTURES AND FANS
OD70277/2025-2026:Supply and fixing of surface mounted LED Industrial Batten of maximum wattage below 40W with System efficacy of more than 120lm/W and lumen output of luminaire greater than 4000 lumen. LED luminaire shall have sleek design with Extruded Aluminium Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution along with driver and surge protection, IP65 dust and water proof LED. The LED shall be compliant with LM80 standard with Useful L70life of 50000Hrs tested at maximum current. The CRI>80 and 4KV internal surge protection. Power factor greater than 0.95,CCT5700K+/-300K, and total harmonic distortion(THD)of less than 10% should be integral to the luminaire.
OD70574/2025-2026:Supply and fixing of surface mounted LED Industrial Batten of maximum wattage below 10W with System efficacy of more than 110lm/W and lumen output of luminaire greater than 1100lumen.The LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution along with driver and surge protection,IP65 dust and water proof LED.The LED shall be compliant with LM80 standard with Useful L70 life of 50000Hrs tested at maximum current. The CRI>80 and 4KV internal surge protection. Power factor greater than 0.95,CCT 5700K+/-300K,ripple factor<5 and total harmonic distortion (THD)of less than 10% should be integral to the luminaire.
OD70283/2025-2026:Supply and installation of surface/Suspended Mounted LED Batten of maximum wattage below 20W with System efficacy of more than 120lm/W and lumen output of luminaire greater than 2000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CCT5000 - 6000K, CRI >80, and 4KV internal surge protection. Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire.
OD70278/2025-2026: Supply and fixing of LED IP54 cleanroom recess mounted panel light fixture light made of CRCA, with System efficacy of more than 110lm/W along with driver of maximum system wattage below 40W with lumen output not less than 4400 lumens. The LED shall be compliant with LM80 standard with Useful L70 life of 50000Hrs tested at maximum current. The CRI>80 and 4KV internal surge protection. Power factor greater than 0.95, CCT5700K+/-300K, , UGR</=19 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire.
OD70275/2025-2026: Supply and installation of LED recess mounted downlight made of die cast aluminium, along with driver, surge protection, maximum system wattage of 18 Watts, lumen output of luminaire greater than or equal to 1980 lumens, power factor>0.95, rated life of L70 50,000hours, system efficacy greater than or equal to 110lumen/watt. The CRI>80 and 4KV internal surge protection, CCT5700K+/- 300K, , UGR</=19 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire.
OD70276/2025-2026:Supply and fixing of LED recess mounted 2x2 panel light fixture, along with driver, with chain and wiring using 3runs of 1.5 sqmm FRLSPVC insulated stranded copper conductor cable as required etc. on false ceiling. The maximum system wattage of 36 Watts, lumen output of luminaire greater than or equal to 4000 lumens, power factor> 0.95, rated life of L70 @50,000 hours, system efficacy greater than or equal to 110 lumen/watt. The CRI >80 and 4KV internal surge protection, CCT5700K+/-300K, UGR</=19 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire.
OD70576/2025-2026:Supply and fixing of outdoor surface mounted LED bulkhead made out of die cast aluminium housing, PC diffuser,<br>along with driver and surge protection, maximum system wattage of 10Watts, luminous efficacy<br>>90lumen/ Watt, system output >= 900 lm, power factor >0.9, rated life of L70@ 50,000 hours, CCT-<br>4000K and including all necessary accessories as required complete.
OD70577/2025-2026:Supply and installation of LED recess mounted downlight made of die cast aluminium, along with driver ,surge protection, maximum system wattage of 10Watts,lumen output of luminaire greater than or equal to 1100lumens, power factor>0.95,rated life of L70@50,000hours,system efficacy greater than or equal to 110lumen/watt. The CRI>80 and 4KV internal surge protection, CCT 5700K+/- 300K,UGR</=19 and total harmonic distortion(THD) of less than 10% should be integral to the luminaire.
OD70282/2025-2026:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
OD70284/2025-2026:Supply of 225 mm sweep,900 rpm light duty exhaust fan in metal body with self opening louvers working on 230 V AC supply complete with all accessories as required.
OD70280/2025-2026:Supply of 450mm sweep heavy duty exhaust fan indie cast aluminium with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: ALMONARD or equivalant approved make)
1.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
OD70578/2025-2026:Supply and fixing of skirting light with all accessories as required complete.
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
OD70281/2025-2026:Supply of 400 mm size wall fan having speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor and all accessories as required complete. Installation, testing and commissioning of Wall fan, including wiring the down rods of standard length with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
EARTHING AND SAFETY EQUIPMENTS
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD70586/2025-2026:Earthing with G.I. earth plate 1200 mm X 1200 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
90.16.4.8:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip
OD70599/2025-2026: Supplying and laying 50 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
OD70600/2025-2026:Supply and fixing single line diagram, schematic diagrams etc. of A0 size on suitable Aluminium sheet including lamination etc. as required complete on wall.
OD70604/2025-2026:Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhesive / compound .
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
OD70617/2025-2026:Supply and fixing of First aid box
OD70618/2025-2026:Supplying of Rubber hand gloves suitable for 11 kV.
OD70616/2025-2026:Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 32mm X6mm GI
LIGHTNING PROTECTION SYSTEM
OD70661/2025-2026:Providing and Fixing of Test Joint , suitable to fix 8 mm Aluminium conductor to 30 X 3 GI strip as per IEC 62305-3
OD70670/2025-2026:Supply and Fixing of 8 mm Aluminum Round Conductor as vertical down conductor with the required mounting clamps , cross connectors, T connectors ,expansion piece and other accessories required as per IEC 62305-3
OD70671/2025-2026:Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace/ roofing tiles with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3
6.14:Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.
SOLAR WORKS
OD70838/2025-2026:Supply, Installation, Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium / GI structure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 545Wp or above, manufactured in India, conforming toIS14286/IEC61215,IS/IEC61730-Part-1,IS/IEC61730-Part-2.Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. B) Power Conditioning Unit (PCU) of 350-800VDC Input voltage range and 400VAC, three phase, 4wire ,50 Hz+/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C .The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories setc.as required. e) Lightning and surge voltage protection .f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. The cost per kWP shall be considered a each unit.
HVAC EQUIPMENTS
OD175440/2025-2026:Supply, Installation, Testing and Commissioning of minimum 11.0 TR capacity Air-cooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel & associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The item shall be complete in all respects complying with technical specifications.
OD175481/2025-2026:Supply, Installation, Testing and Commissioning of minimum 8.5 TR capacity Air-cooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C CFC free refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel & associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The item shall be complete in all respects complying with technical specifications.
OD175528/2025-2026:Supply, Installation, Testing and Commissioning of minimum 5.5 TR capacity Air-cooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C CFC free refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel & associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The item shall be complete in all respects complying with technical specifications.
OD175436/2025-2026:Supply, Installation, Testing and Commissioning of minimum 4.0 TR capacity Air-cooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel & associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The item shall be complete in all respects complying with technical specifications.
OD175433/2025-2026:Supply, Installation, Testing and Commissioning of minimum 3.0 TR capacity Air-cooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel & associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The item shall be complete in all respects complying with technical specifications.
OD175437/2025-2026:Supply, Installation, Testing and Commissioning of minimum 2.0 TR capacity Aircooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel & associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The item shall be complete in all respects complying with technical specifications.
OD175442/2025-2026:Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of minimum 4400 CFM- (11.0 TR) capacity complete with outlet volume control dampers ,canvas connections, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE 3 ,3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, GI support, necessary vibratio isolation arrangement,thermostat, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, thermostat wiring, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.
OD176081/2025-2026:Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of following minimum 2200 CFM- (5.5 TR) capacity complete with outlet volume control dampers ,canvas connections, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE 3 ,3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, GI support, necessary vibration isolation arrangement,thermostat, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, thermostat wiring, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.
OD175445/2025-2026:Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of 1600 CFM- (4.0 TR) minimum capacity complete with outlet volume control dampers ,canvas connections, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE 3 ,3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, GI support, necessary vibration isolation arrangement,thermostat, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, thermostat wiring, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.
OD175426/2025-2026:Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of minimum 1200 CFM- (3.0 TR) capacity complete with outlet volume control dampers ,canvas connections, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE 3 ,3-Ph induction motor, SS Drain Pan, DIDW centrifugal nfan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, GI support, necessary vibration isolation arrangement,thermostat, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, thermostat wiring, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc.(External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.
OD175430/2025-2026:Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of 800 CFM- (2.0 TR) minimum capacity complete with outlet volume control dampers ,canvas connections, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE 3 ,3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, GI support, necessary vibration isolation arrangement, thermostat, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, thermostat wiring, power wiring and associated control wiring. Minimum external static pressure of CSUshall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.
OD176083/2025-2026:Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of minimum 3400 CFM (8.5 TR) capacity complete with outlet volume control dampers ,canvas connections, ,UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be minimum 12watt/sq.ft. of coil surface area for equal distribution, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE3 or better, 3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, VFD, GI support, necessary vibration isolation arrangement,thermostat, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, thermostat wiring, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.
OD176084/2025-2026:Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of minimum 800 CFM (2 TR) capacity ( for ISOLATION ROOMS) complete with outlet volume control dampers ,canvas connections, ,UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be minimum 12watt/sq.ft. of coil surface area for equal distribution, Filter sections with MERV-7 placed in upstream and MERV-17 (HEPA) filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE3 or better, 3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, VFD, GI support, necessary vibration isolation arrangement,thermostat, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, thermostat wiring, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.
OD175439/2025-2026:Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 11 TR machine between indoor & outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications.
OD176088/2025-2026:Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 8.5 TR machine between indoor & outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications
OD176092/2025-2026:Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 5.5 TR machine between indoor & outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value of 0.7 m2 K / W for pipe size greater than 40mm and 0.4 m2K/W for less than 40 mm, complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications
OD175431/2025-2026:Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 4.0 TR machine between indoor & outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications
OD175432/2025-2026:Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 3.0 TR machine between indoor & outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards , complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications.
OD175438/2025-2026:Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 2.0 TR machine between indoor & outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards , complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications
OD175441/2025-2026:Supply, Installation, Testing and Commissioning of minimum 1.0 TR capacity Inverter Decorative(Hi wall) Split air conditioning unit (Indoor and Outdoor Unit) with codensate high lift drain pump, complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and indoor units for single phase 230 V supply minimum 5 star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation, suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) between indoor & outdoor units (upto 5m), duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7 mils glass cloth with required pipe fittings and accessories like bends, tees, reducers, supports complete, necessary power/control cabling as required, suitably supported on trays/ split clamps etc., PVC condensate drain pipe 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell nitrile rubber insulation, required pipe fittings and accessories like bends, tees, reducers, supports, clamps, finished with 7 mils factory laminated treated fibre glass cloth, first charge refrigerant gas R410A/R407C, cordless remote etc. The item shall be complete in all respects complying with technical specifications
OD175450/2025-2026:Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 1.0 TR machine between indoor & outdoor units(after 5 m), duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications
OD175434/2025-2026:Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum 160 CFM -10 mm WG capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications.
OD175449/2025-2026:Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum 250 CFM -10 mm WG capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications.
OD175448/2025-2026:Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum 400 CFM -10 mm WG capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications.
OD175444/2025-2026:Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum 500 CFM -10 mm WG capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications.
OD175435/2025-2026:Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum 800 CFM -15 mm WG capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications.
OD175429/2025-2026:Supply, installation, testing and commissioning of suitable dia PVC condensate drain pipe of 6kg/sq.cm connecting the drain pan of the indoor units to nearest drain point with necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7mils factory laminated glass cloth along with required pipe fittings and accessories like Bends, Tees, reducers, clamps, suitably supported etc. complete in all respects as per the technical specifications.
AIR DISTRIBUTION
16.12.1.1:Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.63 mm sheet.
16.12.1.2:Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.80 mm sheet.
16.12.1.3:Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 Thickness 1.00 mm sheet.
OD175425/2025-2026:Supply, Installation, Testing and Commissioning of Air-Distribution Network made out of suitable thick (gauge) Aluminium sheet as per SMACNA standards for Supply air, Return air, Exhaust Air, Fresh Air rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. associated accessories, supports etc. for critical rooms(X-Ray /MRI/CT room etc.) application and as per relevant SMACNA standards etc. The item shall be complete in all respects complying with technical specifications.
OD175421/2025-2026:Supplying and fixing of suitable thick closed cell nitrile rubber insulation (Class O) with factory laminated aluminium FSK facing of 12 micron to meet minimum R value of 0.6 m2/KW. complete in all respects as per the technical specifications.
OD175420/2025-2026:Supply, Installation, testing and commissioning of Acoustic Insulation of ducts using open cell nitrile rubber having a density of 140-180 kg/m3 and thickness of 10 mm with anti-microbial protection as per EN ISO 846 Method A etc along with manufacturer recommended adhesive where the VOC level should not exceed more than 850 grams / Litre as per IGBC/ GRIHA. Insulation material shall be GRIHA Approved and CFC, HCFC free. Insulation shall be dust and fibre free, complete in all respects as required by the technical specification.
OD176023/2025-2026:Supply, Installation, testing, and commissioning of Under-deck insulation of roof using Class "O" Nitrile rubber insulation of 25mm thickness, anti-microbial insulation and stuck to the roof using suitable adhesives, tapes, etc. with R-value less than 0.6. as per the technical specification. remote/cordless remotes, over current relay, fuses, power supply for suitable operation of 230~1Ph~50Hz A.C, proper drain connections etc with all accessories required for complete installation.
16.17:Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
16.18:Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.
OD175422/2025-2026:Supply, Installation , testing and commissioning of Aluminium extruded fresh air louvers with fresh air damper,bird screen etc. complete in all respects as required by the technical specifications.
OD175423/2025-2026:Supply, Installation , testing and commissioning of Aluminium extruded exhaust air louvers with damper,bird screen etc.complete in all respects as per technical specifications.
16.13:Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. Gl volume control duct damper
OD175424/2025-2026:Supply, Installation, testing & commissioning of Fusible link type Fire damper of 16 gauge GI sheets with fire rating of 300 Deg C for 2 hr for Air Distribution Networks complete in all respects as per the technical specifications.
FIRE HYDRANT AND SPRINKLER SYSTEM
OD173789/2025-2026:Supply, Installation, Testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Horizontal, end suction, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal having rated flow of 2280 lpm at 70m approximate head, conforming to IS 1520.(b) Suitable HP Squirrel cage induction motor conforming to IS 12615 specifications, TEFC, suitable synchronous speed, suitable for operation on 415 volts, 3 phase 50Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard etc. as required.(d) Suitable cement concrete foundation duly plastered along with anti vibration pads/mounts.
OD173806/2025-2026:Supply, Installation, Testing and Commissioning of diesel engine driven fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification.(a) Horizontal, end suction, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal having rated flow 2280 lpm at 70m head, conforming to IS 1520.(b) Suitable HP, suitable RPM water cooled radiator type diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment,12v 180AH Battery and leads, Diesel Tank Fabricated from MS sheet of 4mm Thick (Minimum Capacity for 8 hour operation) with level indicator, Bypass line, piping from diesel tank to engine, exhaust pipe extended upto 1m outside pump house duly insulated with 50 mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(c) M.S. fabricated Common base plate, coupling, coupling guard etc. as required.(d) Suitable cement concrete foundation duly plastered with anti vibration pads/ mounts. (e) Diesel engine control panel.
OD173802/2025-2026:Supply, Installation, Testing and Commissioning of electric driven pressurisation pump (Jockey Pump) suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Vertical Inline pump of stainless steel body and stainless steel impeller with stainless steel shaft, mechanical seal having rated flow of 180 lpm at 70m head conforming to IS 1520 having minimum mechanical efficiency of 70%.(b) Suitable HP Squirrel cage IE3 induction motor conforming to IS 12615 specifications, TEFC, suitable synchronous speed, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Suitable cement concrete foundation.
16.8:Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
OD173815/2025-2026:Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection with IP rated enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system, switch rating 6A Inductive/10A resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC, with ball valve etc. complete as required as per technical specification.
OD173805/2025-2026:Supply, installation, testing and commissioning of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories and painting with synthetic enamel paint of approved shade as required as per technical specification.
OD173788/2025-2026:Supply, Installation, Testing and Commissioning of 200 mm nominal dia (6.3 mm thickness) MS(Heavy C' Class) pipe IS: 3589 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of epoxy primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.
OD173811/2025-2026:Supply, Installation, Testing and Commissioning of 150 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of epoxy primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.
OD173798/2025-2026:Supply, Installation, Testing and Commissioning of 100 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets,<br>nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of epoxy primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification
OD173800/2025-2026:Supply, Installation, Testing and Commissioning of 80 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as<br>required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of epoxy primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.
OD173790/2025-2026:Supply, Installation, Testing and Commissioning of 65 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of epoxy primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification
OD173804/2025-2026:Supply, Installation, Testing and Commissioning of 50 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of epoxy primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification
OD173794/2025-2026:Supply, Installation, Testing and Commissioning of 40 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of epoxy primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification
OD173793/2025-2026:Supply, Installation, Testing and Commissioning of 32 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of epoxy primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.
OD173813/2025-2026:Supply, Installation, Testing and Commissioning of 25 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of epoxy primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.
OD173787/2025-2026:Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 150 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc. complete as required as per the technical specification
OD173803/2025-2026:Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 80 mm diameter conforming to IS 1239 including welding, providing fittings likeelbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc.complete as required as per the technical specification.
OD173797/2025-2026:Supply, installation, testing and commissioning of dual plate non-return valve of 150 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.
OD173816/2025-2026:Supply, installation, testing and commissioning of dual plate non-return valve of 65 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.
OD173824/2025-2026:Supply, installation, testing and commissioning of butterfly valve of 200 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc complete as required as per the technical specification and conforming to IS 13095.
OD173814/2025-2026:Supply, installation, testing and commissioning of butterfly valve of 150 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.
OD173809/2025-2026:Supply, installation, testing and commissioning of butterfly valve of 100 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.
OD173812/2025-2026:Supply, installation, testing and commissioning of butterfly valve of 80 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.
OD173807/2025-2026:Supply, installation, testing and commissioning of butterfly valve of 65 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.
OD173808/2025-2026:Supply, installation, testing and commissioning of butterfly valve of 40 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all Accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.
OD173819/2025-2026:Providing, installation, testing and commissioning of 150 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.
OD173795/2025-2026:Providing, installation, testing and commissioning of 80 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.
OD173796/2025-2026:Supply, installation, testing and commissioning single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain, complete as required as per technical specification.
OD173823/2025-2026:Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as requiredas per technical<br>specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585(b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 25 mm dia stop valve (gun metal) & M.S. Pipe.
OD173810/2025-2026:Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRLhose pipe with 63 mm dia Male and Female Gun metal couplings duly binded withGI wire, rivets etc. conforming to IS 636 (type-1) as required as per technical specification.
OD173817/2025-2026:Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification.
OD173825/2025-2026:Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required as per technical specification.
OD173821/2025-2026:Supply, installation, testing and commissioning of 4-WAY FIRE BRIGADE inlet connection made of CI Body, 150mm dia. flanged inlet with 4 Nos. of inbuilt gunmetal, NRV (Body type) with PVC Blank cap & Chain complete with GI nuts, bolts, gasket etc as required as per technical specification.
OD173801/2025-2026:Supply, installation, testing and commissioning of draw off connection with CI body and gunmetal coupling, complete with GI nuts, bolts, gasket etc as required as per technical specification.
OD173786/2025-2026:Supply, installation, testing and commissioning of UL listed Standard response, standard coverage pendant type sprinkler;1/2" NPT, K -5.6, Chrome Finish with rosetter plate; operating temperature at 68 degC complete as required as per the technical specification
OD173818/2025-2026:Supply, installation, testing and commissioning of UL listed Standard response, standard coverage upright type sprinkler ;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 degC complete as required as per the technical specification
OD173792/2025-2026:Supply, installation, testing and commissioning of 700 mm braided flexible connection to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible connection with nipple, reducer, square bar and brackets etc as required as per technical specification.
OD173820/2025-2026:Supply, installation, testing and commissioning of 1m unbraided flexible connection to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible connection with nipple, reducer, square bar and brackets etc and other accessories as required as per the technical specification.
OD173799/2025-2026:Supply, Installation, Testing and Commissioning of 150mm dia Sprinkler alarm valve of Cast iron body and bronze working parts comprising of watermotor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, flanges, gasket etc. complete as required as per the technical specification.
OD173791/2025-2026:Supply, installation, testing and commissioning of UL listed or FM approved flow switch with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1" to 6". The body of the flow switch shall be water proof with suitable IP class protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 10Kg/cm2 complete with all accessories as required as per the technical specification
OD173822/2025-2026:Supply, installation, testing and commissioning of Air release valve, 25 mm dia, complete as required as pet the technical specification.
OD173785/2025-2026:Supply and installation of fire bucket stand for 4 no's bucket including supply of buckets
PORTABLE FIRE EXTINGUISHERS
OD173774/2025-2026:Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark. The fire extinguisher shall be Halon or any other ozone depleting substance free.
OD173778/2025-2026:Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas, conforming to IS:15683:2018, IS 15222 complete as required as per the technical specification. The fire extinguisher shall be Halon or any other ozone depleting substance free.
OD173775/2025-2026:Supply and installation of ISI marked Clean agent type fire extinguisher of 2kg capacity. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket, all the accessories and as per the technical specifications. The fire extinguisher shall be Halon or any other ozone depleting substance free.
OD173777/2025-2026:Supply, installation, testing and commissioning of Modular (Cealing mounted) clean agent type extinguisher of 5Kg complete as required with all necessary accessories for successful operation as required as per the technical specification. The fire extinguisher shall be Halon or any other ozone depleting substance free.
OD173776/2025-2026:Supply, installation, testing and commissioning of Modular(Cealing mounted) ABC type extinguisher of 5Kg complete with all accessories for mounting on ceiling and successful operation as required as per technical specification. The fire extinguisher shall be Halon or any other ozone depleting substance free.
FIRE DETECTION AND ALARM SYSTEM
17.2.4:INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
17.2.14:INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of addressable manual call point complete as required.
17.2.15:INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
17.2.7:INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of fault isolator complete with base as required.
OD173827/2025-2026:Supply, installation, testing and commissioning of intelligent addressable Input module for monitoring and control, as per the technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.
OD173828/2025-2026:Supply, installation, testing and commissioning of 24V Power supply unit for hooters with battery backup. The status of the power supply unit must be monitored from the FACP and alarm shall be obtained if the power supply unit fails to operate, complete in all respect with necessary accessories as required as per the technical specification
17.1.8:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning talk back slave station in surface/ recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/ microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required.
17.2.1.2:INTELLIGENT FIRE ALARM SYSTEMTwo Loop Panel
17.5.2:CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
SIGNAGES
OD173783/2025-2026:Supply and installation of photo luminescent glow signage such as Fire Lift/Staircase/No smoking etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification
OD173779/2025-2026:Supply and installation of photoluminescent glow signage for "FIRE ASSEMBLY POINT" of standard size (500*225 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.
OD173781/2025-2026:Supply and installation of photo luminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws &double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.
OD173782/2025-2026:Supply and installation of photo luminescent glow signage such as Exit/Fire Exit signage etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.
OD173784/2025-2026:Supply and fixing (in appropriate location) of Fire Emergency Evacuation Plan (Color) printed in photo paper of Size A2 sand-witched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification and conforming to IS 9457, IS 12349, IS 12407 .Evacuation Plan shall be prepared by the contractor and got approved from Client/Consultant.
OD173780/2025-2026:Supply, Installation, Testing, Commissioning of LED Signage conforming to IS 9457, 12349, 12407 . The unit equipment & battery system shall be ANSI/UL 924 listed having 90minute battery backup. The signage should have minimum visibility up to 30m distance.
ELEVATOR SYSTEM
OD176660/2025-2026:Design, fabrication, supply, installation, testing and commissioning of electric traction type with machine room , Stainless steel 26 Pax (1768 Kg) Hospital elevator with car size of 1600 mm (width) x 2400 mm (depth) (including freight & landing charges,insurance and all applicable taxes and duties in country of origin and in India etc- except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, over load warning indicator, battery operated alarmbell, LED type emergency light, intercom suitable for hook upto Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, Automatic Rescue Device (ARD) with dry maintenance free sealed batteries, Safe landing device and Battery operated Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The PMSM traction motor( IE 3 or better efficiency) of machine room elevator shall be of gearless type and placed inside the machine room complete as per technical specification. Having automatic centre/side opening stainless steel doors, Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details:-5 stops & 5 openings and entrance & exit at same side and suitable for travel height of 16.8 mtrs. (Shaft Size 2400mm (width) x 3000mm (depth) ) with door opening of 1200mm (width) and 2000 mm (height) .The equipment should be BMS compatible .All components, fabrication and procedures of elevator system shall confirm to relevant IS standards/ Code and complete in all respects as per technical specifications
STRUCTURED CABLING AND ACTIVE DEVICES
OD58909/2025-2026:Supply, installation, testing and commissioning of U/UTP cable - Category 6A , 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH - with fluke cable analyser through existing conduits including termination, numbering tags, cable ties, ferrules and all accessories required at site to complete the work as per technical specification
OD58911/2025-2026:Supply, installation, testing and commissioning of U/UTP cable - Category 6, 4 pair, 23 AWG solid copper conductor, 250 MHz, LSZH - with fluke cable analyser through existing conduits including termination, numbering tags, cable ties, ferrules and all accessories required at site to complete the work as per technical specification
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
OD58922/2025-2026:Supply and installation of concealed GI metal backbox with all accessories required at site to complete the work as per technical specification
OD58924/2025-2026:Supply, installation, testing and commissioning of Cat6A Information Outlet, RJ 45 with all accessories required at site to complete the work as per technical specification
OD58925/2025-2026:Supply, installation, testing and commissioning of Cat6 information Outlet, RJ 45 with all accessories required at site to complete the work as per technical specification
OD58936/2025-2026:Supply, installation, testing and commissioning of Cat6A 24 port patch panel, fully loaded, with all accessories required at site to complete the work as per technical specification
OD58940/2025-2026:Supply, installation, testing and commissioning of Cat6 24 port patch panel, fully loaded, with all accessories required at site to complete the work as per technical specification
OD58946/2025-2026:Supply, installation, testing and commissioning of Single or Dual Shuttered Face Plate with all accessories required at site to complete the work as per technical specification
OD58947/2025-2026:Supply, installation, testing and commissioning of Cat6A Patch cord - 2m with end termination and all accessories as required at site to complete the work as per technical specification
OD58948/2025-2026:Supply, installation, testing and commissioning of Cat6 Patch Cord - 2m with end termination and all accessories as required at site to complete the work as per technical specification
OD58949/2025-2026:Supply, installation, testing and commissioning of Cat6 Patch Cord - 1m with end termination and all accessories as required at site to complete the work as per technical specification
OD58950/2025-2026:Supply and installation of PVC casing capping with all accessories as required at site to complete the work as per technical specification
OD58992/2025-2026:Supply, installation, testing and commissioning of covered GI unperforated cable tray with 200 mm width x 50 mm depth x 1.6 mm thickness (ISI Grade) with thread road, anchor fastener, nut, washer, etc. including all accessories required at site to complete the work as per technical specification
OD58994/2025-2026:Supply, installation, testing and commissioning of 24 port Stackable switch - Layer 2, 24 x 10/100/1000Base-TX ports and 2 x 10G Copper / SFP+ ports with all necessary hardware and accessories required at site to complete the work as per technical specification
OD58995/2025-2026:Supply, installation, testing and commissioning of Core Switch - Layer 3, with min 12 x 10/100/1000Base-TX ports and min 4 x 10G Copper / SFP+ ports and all necessary hardware and accessories, as required at site to complete the work as per technical specification
OD58996/2025-2026:Supply, installation, testing and commissioning of next generation Firewall having a capacity of handling 150 concurrent users with logs, monitoring, bandwidth management, security subscriptions, including software, licenses and all accessories required at site to complete the work as per technical specification
OD58997/2025-2026:Supply, installation, testing and commissioning of 42U Network Rack (800mm x 1000mm) along with all hardware and accessories required at site to complete the work as per technical specification
IP-PBX
OD59061/2025-2026:Supply, installation, testing and commissioning of IP-PBX system expandable upto 120 IP extensions, 1 no PRI license, 1 no of 10 channel SIP trunk licenses, including all hardware, software, 1 no of desktop based operator console and all accessories as required at site to complete the work as per technical specification.
OD59063/2025-2026:Supply, installation, testing and commissioning of license of IP extensions with all accessories as required at site to complete the work as per technical specification.
OD59064/2025-2026:Supply, installation, testing and commissioning of Standard IP Phones with all accessories as required at site to complete the work as per technical specification.
OD59065/2025-2026:Supply, installation, testing and commissioning of 24 port PoE+ Stackable switch - Layer 2, 24 x 10/100/1000Base-TX PoE+ ports and 2 SFP ports with all necessary hardware and accessories required at site to complete the work as per technical specification.
CCTV SURVEILLANCE SYSTEM
OD59112/2025-2026:Supply, installation, testing and commissioning of 2MP varifocal IP camera, PoE, IP66 rated along with all accessories as required at site to complete the work as per technical specification.
OD59113/2025-2026:Supply, installation, testing and commissioning of 24 port PoE+ switch - Layer 2, 24 x 10/100/1000Base-TX PoE+ ports and 2 x 1G SFP ports with all necessary hardware and accessories required at site to complete the work as per technical specification
OD59114/2025-2026:Supply, installation, testing and commissioning of 32 channel Network Video Recorder, SAS/Enterprise HDDs, RAID5 with 30 days storage, all required hardware including a desktop, cabling and accessories as required at site to complete the work as per technical specification
OD59115/2025-2026:Supply, installation, testing and commissioning of 55" commercial display 24/7 with HDMI, USB ports with all accessories required at site to complete the work as per technical specification
ATTENDANCE MACHINES
OD59129/2025-2026:Supply, installation, testing and commissioning of biometric, password and proximity card based Attendance Machine with software and all accessories as required at site to complete the work as per technical specification.
PUBLIC ADDRESS AND EVACUATION SYSTEM
17.5.3.1:Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Single pair, 2-core, 1.5 sq mm
17.3.2:PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
17.3.3:PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
OD59138/2025-2026:Supply, installation, testing and commissioning of 240W power amplifier along with all accessories as required at site to complete the work as per technical specification.
OD59139/2025-2026:Supply, installation, testing and commissioning of Controller capable of managing atleast 6 individual zones with BGM, announcement, automatic emergency message facility, integration with fire alarm system with all accessories required at site to complete the work as per technical specification.
SANITARY INSTALLATION AND FIXTURES
50.17.1.5:Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
17.10.1.1:Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board510x1040 mm bowl depth 250 mm
18.16.2:Providing and fixing brass stop cock of approved quality :20 mm nominal bore
50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
OD173494/2025-2026:Providing and fixing white vitreous urinal division plate of approved quality as per the requirements of the Engineer in charge at all levels. Models Hindware 61001/Kerovit KS506 or equivalent as required by the Engineer in Charge. Details of cost for one no. MATERIAL: Wooden cleates
OD173497/2025-2026:Providing and fixing floor trap with cockroach trap (multi trap), concealed , SS304 grade floor grating with cup including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in Charge at all levels
OD173501/2025-2026:Providing and fixing floor trap with cockroach trap (multi trap), exposed , SS304 grade floor grating with cup including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in Charge at all levels.
OD173510/2025-2026:Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels 75mm dia.
OD173506/2025-2026:Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels 110mm dia
OD173505/2025-2026:Supply, Installation, Testing and Commissioning of Solar Water Heater 1000 LPD with heater backup with all necessary accessories as per the requirements of the Engineer in charge at all levels. The rate is inclusive of cost and conveyance of all materials, labour charges etc
OD173509/2025-2026:Providing and fixing premium quality C.P. brass wall shower mixer along with overhead shower and shower arm with IGBC water conservation mechanism with a flow rate of 6 lpm at 3 bar pressure with wall flanges of approved make and model including cost of all materials, labour etc., complete as directed by the Engineer-in-Charge at all levels. Models Hindware Cat No- F160145+F650020/ Cera Cat No:F7010213AB+F1023401 OR equivalent
OD173499/2025-2026:Providing and fixing CP Brass robe hook as per the instructions of the Engineer in charge. Models Jaquar ACN CHR1191N/Kerovit KA930002 or equivalent as instructed by Engineer in charge
OD173507/2025-2026:Providing and fixing Stainless Steel A ISI 304 (18/8) 2 station Scrub sink with elbow operated sink cocks as per IS 13983 with C.I. brackets and stainless steel plugs 40 mm, including painting of fittings and brackets, cutting and making good the walls etc complete as per the requirements of the site in charge including cost of conveyance, testing, commissioning, installation etc with IGBC water conservation mechanism with a flow rate of 4lpm at 3 bar pressure.
OD173504/2025-2026:Providing and fixing Stainless Steel A ISI 304 (18/8) bed pan sink of approved shape and size with elbow operated sink cock as per IS 13983 with C.I. brackets and stainless steel plugs 40 mm, including painting of fittings and brackets, cutting and making good the walls etc complete as per the requirements of the site in charge including cost of conveyance, testing, commissioning, installation etc as directed by the Engineer in charge at all levels.
OD173511/2025-2026:Providing, fixing and testing white vitreous china extended wall mounting water closet of approved shape including white vitreous china cistern with dual flush fitting including seat cover, and cistern fittings, nuts bolts and gasket, angle valve etc complete with IGBC water conservation mechanism with a flow rate of 4.5/3 lpf at 3 bar pressure as required by the Engineer in Charge at all levels (Models- 20096+21056(ETIOS)/Cera S1031104+S1060104+B1510124+B1810107) or equivalent Details of cost for each MATERIAL:
OD173508/2025-2026:Providing and fixing white vitreous china wall hung wash basin of approved make and size including one CP brass pillar cock with IGBC water conservation mechanism with a flow rate of 4 lpm at 3 bar pressure including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling,32 mm dia CP brass bottle trap ,angle valve etc ,complete including CI/MS brackets duly painted, nuts, washers, etc. complete, cost and conveyance of all materials labour charges ,lead, lift necessary wall cutting /chasing and making good the walls ,floors, slab, testing and commissioning to the satisfaction of Engineer in charge at all levels. Models Cera Cat no:S2040163+F1023101/ Hindware Cat No- 10096+F650003 or equivalent as instructed by the Engineer in charge at all levels. Details of cost for one no. MATERIAL:
OD173498/2025-2026:Providing and fixing star white vitreous china under counter wash basin of approved size & make including one CP brass pillar cock 15 mm NB with aerator with IGBC water conservation mechanism with a flow rate of 4lpm at 3 bar pressure including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling, 32mm dia CP brass bottle trap,15mm angle valve, etc. complete as directed by the Engineer in charge at all levels.(Models Cera Cat no:S2030203+F1023101/Hindware Cat No- 10049+F650003 or equivalent as per the instructions of the engineer in charge at all levels) IGBC conservation measures. Details of cost for one no.
OD173502/2025-2026:Providing and fixing white vitreous china flat back urinal(sensor) with GRIHA conservation mechanism with a flow rate of 2 lpf at 3 bar pressure and C.P.brass spreaders with brass unions and G.I. clamps, etc. complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. (Models Cera Cat no:S4010102/ Hindware Cat No- 60021 or equivalent as instructed by engineer in charge at all levels.) Details of cost for one no MATERIAL:
OD173495/2025-2026:Providing and fixing sanitary fixtures for handicapped toilet including one wash basin mounting brackets,one number pillar cock with IGBC water conservation mechanism with a flow rate of 4lpm at 3 bar pressure & all other related fittings like waste coupling, etc,one number EWC & Cistern complete with igbc water conservation mechanism with a flow rate of 2 lpf with fittings & seat cover, hinged rail, grab rails (5 nos) etc designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever require as per drawing and as directed by Engineer in charge at all levels. (Model no:H i n d w a r e ( 7 0 0 0 2 M a t r i x) +Jaquar (FLR CHR5031NGE ) / Cera Cruse Set(S1013200+B1520118+S2040159+B2210106+B2210108+F9030101+S2040102) or equivalent) as instructed by the Engineer in Charge at all levels Details of cost for 1 set(Rate Analysis Arrived from DSR 17.3.1+17.7.2) MATERIAL:
OD173512/2025-2026:Providing and fixing long body CP brass bib cock of approved quality and specification with IGBC water conservation mechanism with a flow rate of 4 lpm at 3 bar pressure as required by the Engineer in charge at all levels.(Model Hindware Cat No- F650006/ Cera Cat no:F1023151 or equivalent). Details of cost for one no.
OD173496/2025-2026:Providing and fixing CP brass sink cock of approved quality and specifications with IGBC water conservation mechanism with a flow ate of 4 lpm at 3 bar pressure as required by the Engineer in Charge at all levels.(Models : Hindware Cat No- F650023/ Cera Cat no:F1023251 or equivalent) Details of cost for one number
OD173503/2025-2026:Providing and fixing white vitreous china wall hung wash basin (corner) of approved make including one CP brass pillar cock with IGBC complying flow rates of 4lpm at 3 bar pressure including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling,32mm dia CP brass bottle trap ,angle valve etc ,complete including CI/MS brackets duly painted, nuts, washers, etc.complete,cost and conveyance of all materials labour charges ,lead, lift necessary wall cutting /chasing and making good the walls,floors,slab,testing and commissioning to the satisfaction of Engineer in charge at all levels. Models Cera- S2040161 or equivalent as instructed by the Engineer in charge at all levels. Details of cost for one no. MATERIAL:
OD173500/2025-2026:Providing and fixing water closet squatting pan (Indian type W.C. pan ) with P or S trap, 10 litre low level white P.V.C. flushing cistern with 4.5/3 lpf as per IGBC norms including flush pipe, with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of approved size and make with integral type foot rests etc. as directed by the Engineer in charge at all levels.(Models: Hindware Cat no: 20070+511217/ Cera Cat no:S3010102+B1020109 or equivalent as approved by the Engineer in Charge at all levels.)
17.11.1:Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 450x300x150 mm
Water Supply
50.18.8.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2
50.18.8.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2
50.18.8.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2
50.18.8.5.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2
18.7.2:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal dia pipes
18.7.3:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal dia pipes
18.7.4:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal dia pipes
18.7.5:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal dia pipes
18.7.6:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal dia pipes
18.9.7:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work65 mm nominal dia pipes
18.9.6:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal dia pipes
18.17.1A:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
18.17.1:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
18.17.2:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
18.17.3:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
18.17.5:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
18.17.6:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
OD173513/2025-2026:Providing and fixing 80 mm dia CI vent cowl as directed by Engineer-in-charge at all levels. 80 mm dia
OD173516/2025-2026:Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15x15 cm and weighing not less than 440 grams.
OD173517/2025-2026:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 80mm nominal dia pipes
OD173514/2025-2026:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 65 nominal dia pipes
OD173515/2025-2026:Supplying ,fixing, testing and commissioning of portable drainage pump 2Hp, with stainless steel construction, stainless steel impeller complete with motor , with carrying handle and all accessories and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all labour charges,lead,lift etc as directed by the Engineer in charge at all levels.
Sanitary Arrangement
50.18.9.21.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl
50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
50.18.9.8.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
50.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
50.18.9.10.1:Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
50.18.9.18.2:Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall
50.18.9.16.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall
50.18.9.18.1:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
50.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
50.18.8.8.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
OD173518/2025-2026:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 60 x 60 cm and 100 cm deep including C.I. cover 500 mm with frame(medium duty) : With bricks.Class designation 75
19.7.1.1:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.8.1.1:Extra for depth for manholes Size 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
OD173520/2025-2026:Supplying approved make PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gullytrap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site, cleaning, installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge.
OD173519/2025-2026:Supplying and fixing GI threaded rod for fixing pipes to walls on slotted channels adequately spaced from the walls.The rate is inclusive of cost and conveyance of all materials,labour charges etc and as directed by the Engineer in charge at all levels.
Pumps, Filters and Accessories
18.19.3.1:Providing and fixing gun metal non-return valve of approved quality (screwed end): 40 mm nominal boreHorizontal
18.19.4.1:Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal boreHorizontal
18.19.5.1:Providing and fixing gun metal non-return valve of approved quality (screwed end): 65 mm nominal boreHorizontal
2.10.1.2:Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soilPipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
OD173542/2025-2026:Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete with motor, base plate, foundation bolts, nuts, pressure gauge and all accessories, and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials, labour charges etc with IGBC compliance of BEE rating 3 complete as directed by the Engineer in charge at all levels Capacity 12cum/hour , Head - 35m
OD173524/2025-2026:Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure gauge and all accessories and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc with IGBC compliance of BEE rating 3 as directed by the Engineer in charge at all levels Capacity 29 cum/hour , Head - 40m
OD173527/2025-2026:Supplying ,fixing, testing and commissioning of portable drainage pump 2Hp, with stainless steel construction, stainless steel impeller complete with motor , with carrying handle and all accessories and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all labour charges,lead,lift etc with IGBC compliance of BEE 3 rating as directed by the Engineer in charge at all levels.
OD173522/2025-2026:Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 50 mm.
OD173540/2025-2026:Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 40 mm.
OD173535/2025-2026:Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge at all levels 40mm 'Y' type strainer. Details of cost for one strainer.
OD173528/2025-2026:Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge at all levels 50 mm 'Y' type strainer. Details of cost for one strainer.
OD173529/2025-2026:Design, Supply, Installation, Testing & Commissioning of 1000LPH fully automatic RO system consists of 1Nos. Dual media filter with sand and graded xylex media,1Nos. Activated carbon filter, 2Nos of wound type Sediment Cartridge filter ,1 Nos. High Pressure Vertical multistage Pump with a capacity 3HP @30-147m head, 1Nos. Membrane pressure tube, 1Nos Membrane, and other instruments likes 1No Flow meter Panel Mount 1200 LPH, 1Nos Flow meter Panel Mount 2400 LPH,2Nos Pressure gauges (0-21 bar),1Nos LP Switch,1Nos HP Switch,1Nos Feed Pump with a capacity of 3000 lph @ 30 meter head,1Nos Anti Scalant Dosing pump with a capacity of 6lph @ 4 bar dosing tank 50 ltrs,1Nos SMPS Dosing pump with a capacity of 6lph @ 4 bar, 1Nos RO Control Panel, 1Nos UV System etc complete.
OD173523/2025-2026::Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete: 150 mm dia R.C.C. pipe Details of cost for 10 metre LABOUR:
OD173525/2025-2026::Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete: 300 mm dia R.C.C. pipe Details of cost for 10 metre LABOUR:
OD173531/2025-2026:Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge at all levels. 200 mm
OD173538/2025-2026:Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge at all levels. 65 mm
OD173539/2025-2026:Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge at all levels. 65 mm
OD173521/2025-2026:Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge at all levels. 80 mm
OD173530/2025-2026:Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge at all levels. 100 mm
OD173537/2025-2026:Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge at all levels. 150 mm Details of cost for 10 joints
OD173533/2025-2026:Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed bythe Engineer in Charge at all levels. 150mm Details of cost for 10 joints
OD173526/2025-2026:Supplying and fixing of electronic diaphragm type dosing pump with all wetted parts in PVC construction suitable for pumping HoCl solution including cost of valve, suction and delivery lines using heavy duty PVC tubes, HDPE tank of 80 litres capacity etc. and complete with all accessories as directed by the Engineer- in -Charge at all levels.Capacity : 12 lph @ 3.5 kg/cm2
OD173534/2025-2026:Supply and erection of dual media filter of size 0.6m dia x 1.2 m HOS, (approx.) vertical type pressure vessel, mild steel internally and externally epoxy coated, 6mm shell thickness, 6mm dish thickness, flanged top and bottom, operating pressure of 3.5 Kg/cm2, complete with CI valves and graded pebble and sand as media, frontal piping, pressure gauges, strainers, supporting structure, back wash arrangement, etc and all other accessories .Flow rate 5m3/hr
OD173532/2025-2026:Supplying and installing activated carbon filter of size 5 cum/hr with internally and externally epoxy coated, raw water distributor, filter water collecting system, pressure gauges at inlet and outlet, strainers, supporting structure, back wash arrangement, set of inlet and outlet valves, Vnotch Board etc and all other accessories .The rate shall include cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge at all levels.
OD173536/2025-2026:Providing,fixing and testing digital water meter with digital display with all internal parts in gunmetal or brass, strainer, flanged distance piece for easy removal in future, bourdon type pressure gauge and isolation cock including necessary test certificate for the meter from local municipal authorities & ISI marked along with all accessories as per the instructions of the Engineer in Charge at all levels: 25 mm nominal bore.
OD173541/2025-2026:Providing,fixing and testing digital water meter with digital display with all internal parts in gunmetal or brass, strainer, flanged distance piece for easy removal in future, bourdon type pressure gauge and isolation cock including necessary test certificate for the meter from local municipal authorities & ISI marked along with all accessories as per the instructions of the Engineer in Charge at all levels: 80 mm nominal bore
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY (BID ID -2385347)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.51 MB
dwgscombined.pdf
Other Document • 24.75 MB
Technicalbid.pdf
Tender Documents • 9.94 MB
BOQ_1334126.xls
BOQ • 0.81 MB
Download all tender documents and submit your bid