Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC DEHRADUN | ₹7.6 L Quoted ₹7.7 L | L1 | Accepted-AOC L1 Lowest Reasonable Rate |
| 2 | L2₹7.9 L+₹18,308.67 (2.37%)Rejected-Finance C 23 CC | ₹7.9 L+₹18,308.67 (2.37%) | L2 | Rejected-Finance 2ND LOWEST |
| 3 | L3₹8.3 L+₹60,864.40 (7.89%)Rejected-Finance 3491 14 HARIPURA DHAPAI ROAD AMRITSAR | AMRITSAR | PUNJAB | 143001 | ₹8.3 L+₹60,864.40 (7.89%) | L3 | Rejected-Finance 3RD LOWEST |
| 4 | L4₹8.5 L+₹78,257.50 (10.1%)Rejected-Finance DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹8.5 L+₹78,257.50 (10.1%) | L4 | Rejected-Finance 4TH LOWEST |
| 5 | L5₹9.2 L+₹1.5 L (19.7%)Rejected-Finance | ₹9.2 L+₹1.5 L (19.7%) | L5 | Rejected-Finance 5TH LOWEST |
| Sl No | Description | Qty | Unit | TARUN ENGINEERING WORKS L4 | RAMAN CONSTRUCTION CO. L2 | RAJENDER CONSTRUCTION CO L5 | Malik Associates L1 | AMARJEET SINGH AND CO. L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed.
Note :- (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . (b) The rates quoted shall deemed to be included for these items | 670 | sqm | 45 ₹30,150 | 21 ₹14,070 | 30 ₹20,100 | 20 ₹13,400 | 15 ₹10,050 Lowest |
| 2.00 | M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with Liquid intergal water proofing compoud as per manufacturer direction and finishing the surface even and smooth with out using extra cement as in roof padding treatement to receive roof treatment complete all as specified and directed.
Note :- liquid water proofing compound will be measured and paid seperately. | 26.8 | cum | 5,100 ₹1,36,680 | 4,180 ₹1,12,024 | 6,000 ₹1,60,800 | 4,200 ₹1,12,560 | 3,800 ₹1,01,840 Lowest |
| 3.00 | M/L for PCC 1:1.5:3 type A-0 (Using 12.5mm stone aggregate)as in concrete angle-fillets with a radiaus of 75mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging ) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners mixed with Liquid intergal water proofing compoud as per manufactur direction )
Note :- liquid water proofing compound will be measured and paid seperately. | 1.34 | Cum | 6,000 ₹8,040 | 5,200 ₹6,968 | 6,500 ₹8,710 | 4,200 ₹5,628 | 3,500 ₹4,690 Lowest |
| 4.00 | Supply only Liquid intergal water proofing compoud | 33.97 | Ltr | 100 ₹3,397.44 | 61 ₹2,072.44 Lowest | 100 ₹3,397.44 | 200 ₹6,794.88 | 120 ₹4,076.93 |
| 5.00 | M&L for one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be used for bonding of new concrete/ mortar to old surface.
Note :- (i)The work is required to be carried out at non-accessible roof for double storey . (ii)The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof .(iii) The rates quoted shall deemed to be included for these items. | 670 | Sqm | 32 ₹21,440 | 84 ₹56,280 | 20 ₹13,400 Lowest | 20 ₹13,400 Lowest | 25 ₹16,750 |
| 6.00 | M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :-
(a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated.
(b) Providing APP based 5 layer polymeric membrane minimum weighing 3 Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer
(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance
Note :
1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only.
2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items. | 670 | Sqm | 444 ₹2,97,480 | 399 ₹2,67,330 Lowest | 600 ₹4,02,000 | 550 ₹3,68,500 | 485 ₹3,24,950 |
| 7.00 | Dismantaling RCC /PVC water tanks and S&F new rotational moulded polyethylene water storage tank 1000 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position including S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed. | 4 | Each | 11,000 ₹44,000 | 9,229 ₹36,916 | 9,000 ₹36,000 | 8,000 ₹32,000 Lowest | 9,800 ₹39,200 |
| 8.00 | Dismantaling RCC /PVC water tanks and S&F new rotational moulded polyethylene water storage tank 500 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position including S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed. | 4 | Each | 5,000 ₹20,000 | 5,229 ₹20,916 | 4,500 ₹18,000 | 4,000 ₹16,000 Lowest | 5,200 ₹20,800 |
| 9.00 | Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia . | 30 | RM | 50 ₹1,500 | 19 ₹570 | 50 ₹1,500 | 10 ₹300 Lowest | 22 ₹660 |
| 10.00 | M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed | 20 | R M | 250 ₹5,000 | 309 ₹6,180 | 350 ₹7,000 | 150 ₹3,000 Lowest | 420 ₹8,400 |
Tender Value
₹9.1 L
EMD Value
₹18,200
Closing Date
4 May 2026, 9:00 amClosed
AGE (i) RAIWALA
AGE (i) RAIWALA
REPAIR/ REPLACEMENT OF ROOF TREATMENT, LEAKAGE AND ALLIED WORKS AT ZONE C AT MIL STN RAIWALA UNDER AGE (I) RAIWALA
2026_MES_760478_1
8119/E8
Open Tender
Civil Works
Works
120 days
AGE (I) RAIWALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) RAIWALA
₹18,200
Yes
4 Sept 2026
16 Apr 2026
6 May 2026
16 Apr 2026
4 May 2026
28 Apr 2026
16 Apr 2026 - 27 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed.
Note :- (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . (b) The rates quoted shall deemed to be included for these items | - | sqm | - | - |
| - | M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with Liquid intergal water proofing compoud as per manufacturer direction and finishing the surface even and smooth with out using extra cement as in roof padding treatement to receive roof treatment complete all as specified and directed.
Note :- liquid water proofing compound will be measured and paid seperately. | - | cum | - | - |
| - | M/L for PCC 1:1.5:3 type A-0 (Using 12.5mm stone aggregate)as in concrete angle-fillets with a radiaus of 75mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging ) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners mixed with Liquid intergal water proofing compoud as per manufactur direction )
Note :- liquid water proofing compound will be measured and paid seperately. | - | Cum | - | - |
| - | Supply only Liquid intergal water proofing compoud | - | Ltr | - | - |
| - | M&L for one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be used for bonding of new concrete/ mortar to old surface.
Note :- (i)The work is required to be carried out at non-accessible roof for double storey . (ii)The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof .(iii) The rates quoted shall deemed to be included for these items. | - | Sqm | - | - |
| - | M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :-
(a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated.
(b) Providing APP based 5 layer polymeric membrane minimum weighing 3 Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer
(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance
Note :
1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only.
2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items. | - | Sqm | - | - |
| - | Dismantaling RCC /PVC water tanks and S&F new rotational moulded polyethylene water storage tank 1000 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position including S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed. | - | Each | - | - |
| - | Dismantaling RCC /PVC water tanks and S&F new rotational moulded polyethylene water storage tank 500 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position including S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed. | - | Each | - | - |
| - | Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia . | - | RM | - | - |
| - | M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed | - | R M | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
TD8119.pdf
Tender Documents • 1.77 MB
MAKEAPPROVAL.pdf
Additional Documents • 15.01 MB
BOQ_851831.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .