Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder and quoted reasonable rate | |
| 2 | L2₹34.9 L+₹1.5 L (4.42%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹36.1 L+₹2.7 L (8.09%)Rejected-Finance 12 DORU DOORU VERINAG ROAD NEAR TOWN HALL ANANTHNAG JAMMU KASHMIR 192211 | ANANTNAG | JAMMU AND KASHMIR | 192211 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹39.9 L+₹6.5 L (19.6%)Rejected-Finance 01 POYEN KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹42.3 L+₹8.9 L (26.8%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | M/S ALI MOHD AND SONS L3 | M/S MOHD HUSSAIN L2 | M/S MOHD HASSAN L4 | HUSNIA BANOO L1 | M/S Ghulam Mustafa L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets of any thickness, including cover fillets complete all as specified and directed by the Engg-in-Charge. | 497 | Sqm | 23 ₹11,431 | 18 ₹8,946 Lowest | 20 ₹9,940 | 20 ₹9,940 | 30 ₹14,910 |
| 2.00 | S&F 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in walls complete all as specified and directed by the Engg-in-Charge. | 338 | Sqm | 1,020 ₹3,44,760 | 985 ₹3,32,930 | 1,950 ₹6,59,100 | 950 ₹3,21,100 Lowest | 2,000 ₹6,76,000 |
| 3.00 | S&F Solid PVC Wall Lining consisting of 5mm thick wood grain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per manufacturer's specifications complete all as specified and directed by the Engg-in-Charge. | 62 | Sqm | 2,550 ₹1,58,100 | 2,380 ₹1,47,560 | 2,200 ₹1,36,400 Lowest | 2,400 ₹1,48,800 | 2,500 ₹1,55,000 |
| 4.00 | S&F 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in ceiling or sloping portion complete all as specified and directed by the Engg-in-Charge. | 97 | Sqm | 800 ₹77,600 | 910 ₹88,270 | 700 ₹67,900 Lowest | 800 ₹77,600 | 750 ₹72,750 |
| 5.00 | Dismantling of timber scantling fillets, rails, posts rafters, purlins etc under 40 Sqcm, in any position as in unframed work complete all as specified and directed by the Engg-in-Charge. | 957.85 | Rm | 35 ₹33,524.75 | 28 ₹26,819.8 | 30 ₹28,735.5 | 20 ₹19,157 Lowest | 25 ₹23,946.25 |
| 6.00 | S&F second clas soft wood fillets square or rectangular in section with sectional area exceeding 13 sq cm and n exc 25 sq cm as in scantling secured with nails or beads complete all as specified and directed by the Engg-in-Charge. | 957.85 | Rm | 100 ₹95,785 | 74 ₹70,880.9 Lowest | 150 ₹1,43,677.5 | 80 ₹76,628 | 180 ₹1,72,413 |
| 7.00 | S&F second class softwood fillets square, rectangular or triangular in section sectional area not exceeding 3 sqcm, clean sawn, secured with nails or beads bullnosed, splayed, chamfered or rounded on one edge or face as in cover fillets complete all as specified and directed by the Engg-in-Charge. | 173 | Rm | 150 ₹25,950 | 50 ₹8,650 Lowest | 200 ₹34,600 | 50 ₹8,650 Lowest | 220 ₹38,060 |
| 8.00 | S&F second class softwood moulding as in cornices, picture rails and the like sectional area not exceeding 6 Sqcm fixed with nails complete all as specified and directed by the Engg-in-Charge. | 157 | RM | 75 ₹11,775 | 60 ₹9,420 Lowest | 100 ₹15,700 | 65 ₹10,205 | 120 ₹18,840 |
| 9.00 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed by the Engg-in-Charge. | 786.5 | Sqm | 10 ₹7,865 Lowest | 75 ₹58,987.5 | 30 ₹23,595 | 60 ₹47,190 | 35 ₹27,527.5 |
| 10.00 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engg-in-Charge. | 598 | sqm | 1,000 ₹5,98,000 | 990 ₹5,92,020 | 800 ₹4,78,400 Lowest | 900 ₹5,38,200 | 850 ₹5,08,300 |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
18 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Kargil
Office of GE Kargil, PIN - 908121, C/o 56 APO
CA NO. GE/K-56/2025-26 - SPL REPAIR OF CERTAIN ITEMS IN BLDG NO. T-40 AT 851 FD WKSP COY, TE-100 (COOK HOUSE) AND TE-101 (OR LINE) AT COMPO PL HENISKUT AND T-30 AND T-16 AT 508 ASC BN (MARATHA HIGH GROUND) UNDER GE KARGIL
2025_MES_721585_1
CA NO. GE/K-56/2025-26
Open Tender
Civil Works
Item Rate
180 days
Kargil
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kargil
₹65,000
Yes
30 Aug 2025
19 Jul 2025
20 Aug 2025
19 Jul 2025
18 Aug 2025
4 Aug 2025
Amount
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets of any thickness, including cover fillets complete all as specified and directed by the Engg-in-Charge.
S&F 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in walls complete all as specified and directed by the Engg-in-Charge.
S&F Solid PVC Wall Lining consisting of 5mm thick wood grain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per manufacturer's specifications complete all as specified and directed by the Engg-in-Charge.
S&F 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in ceiling or sloping portion complete all as specified and directed by the Engg-in-Charge.
Dismantling of timber scantling fillets, rails, posts rafters, purlins etc under 40 Sqcm, in any position as in unframed work complete all as specified and directed by the Engg-in-Charge.
S&F second clas soft wood fillets square or rectangular in section with sectional area exceeding 13 sq cm and n exc 25 sq cm as in scantling secured with nails or beads complete all as specified and directed by the Engg-in-Charge.
S&F second class softwood fillets square, rectangular or triangular in section sectional area not exceeding 3 sqcm, clean sawn, secured with nails or beads bullnosed, splayed, chamfered or rounded on one edge or face as in cover fillets complete all as specified and directed by the Engg-in-Charge.
S&F second class softwood moulding as in cornices, picture rails and the like sectional area not exceeding 6 Sqcm fixed with nails complete all as specified and directed by the Engg-in-Charge.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed by the Engg-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engg-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engg-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and directed by the Engg-in-Charge.
Taking down shutters exc 1 sqm and nexc 2 sqm each complete all as specified and directed by the Engg-in-Charge.
M&L for second class softwood (KAIL), plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed by the Engg-in-Charge.
S&F 35mm thick second class softwood (KAIL) Plain, framed, panelled shutters (any panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed by Engr-in-Charge.
S&F second class softwood (KAIL) 30 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. complete all as specified and directed by the Engg-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) nexc 1.5 sq. m each complete all as specified and directed by the Engg-in-Charge.
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5mm thick PVC sheet reinforced with mild steel square tube complete all as specified and directed by the Engg-in-Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed by the Engg-in-Charge.
S&F 3mm thick sheet glass ordinary quality and glazing with beading/oil putty in squares nexc 0.5 Sqm in each pane complete all as specified and directed by the Engg-in-Charge.
S&F 100mm butt hinges medium weight cold rolled mild steel fixed with screws or welded complete all as specified and directed by the Engg-in-Charge.
S&F 75 mm butt hinges medium weight cold rolled mild steel fixed with screws or welded complete all as specified and directed by the Engg-in-Charge.
S&F 150mm anodised aluminium barrel tower bolt extruded sections fixed with screw or welded complete all as specified and directed by the Engg-in-Charge.
S&F 100mm anodised aluminium barrel tower bolt extruded sections fixed with screws or welded complete all as specified and directed by the Engg-in-Charge.
S&F 100mm long Aluminium handles, cast type, anodised complete all as specified and directed by the Engg-in-Charge.
S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed by the Engg-in-Charge.
M&L for preparing previously untreated wood and wood based material of any description over 10cm width/girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by the Engg-in-Charge.
M&L for preparing old wooden surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint complete all as specified and directed by the Engg-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by the Engg-in-Charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed by the Engg-in-Charge.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete incl 15mm thick screed bed in CM 1:4 complete all as specified and directed by the Engg-in-Charge.
M&L for coloured non-skid ceramic tiles 7 to 8mm thick (square / rectangle) area of each tile exc 0.06 sqm but not exc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the work including 15 thick screed bed in CM (1:6) complete all as specified and directed by the Engg-in-Charge.
M&L for 25 mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded aggregate) as in subbase to floors or similar works complete all as specified and directed by the Engg-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and directed by the Engg-in-Charge.
M&L for hardcore with broken stone or boulders of guage exc 63mm but nexc 100 mm, deposited, spread and levelled in layers nexc. 15cm thick, watered and rolled/rammed to a true surface complete all as specified and directed by the Engg-in-Charge.
M&L for 75 mm thick PCC 1:3:6. type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection or similar works complete all as specified and directed by the Engg-in-Charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations, mass filling, sub base and the like complete all as specified and directed by the Engg-in-Charge.
M&L for PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and directed by the Engg-in-Charge.
Demolition of precast concrete articles and precast concrete block walling including all quoins, arches, pillars, etc built in cement mortar of any description not other specifically provided for etc complete all as specified and directed by the Engg-in-Charge.
M&L for Precast cement concrete type C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge.
M&L for applying 02 coats of cement based paint on old plastered surfaces of walls including preparation of surfaces complete all as specified and directed by the Engg-in-Charge.
M&L for rendering 15mm thick in CM (1:4) finished even & fair without using extra cement on brick/concrete surfaces complete all as specified and directed by the Engg-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed by the Engg-in-Charge.
M&L rendering 15mm thick in CM (1:6) finished even & smooth without using extra cement on brick/concrete surfaces complete all as specified and directed by the Engg-in-Charge.
S&F in repair Harrison rails anodised aluminium alloy chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed by the Engg-in-Charge.
S&F in repairs stainless steel squatting pan of pattern “long pan”, size 580 x 440 mm with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) complete all as specified and directed by the Engg-in-Charge.
S&F in repairs 10 ltrs capacity PVC valveless syphonic action type low level flushing cistern complete with syphone handle lever PVC bend including connecting to WC and fixing on walls with bracket complete all as specified and directed by the Engg-in-Charge.
S&F in repairs vitreous china wash hand basin (flat black) white of size 550x400mm with pedestal excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size complete all as specified and directed by the Engg-in-Charge.
S&F in repairs 32mm dia Waste coupling of CP brass for WHB including waste pipe complete all as specified and directed by the Engg-in-Charge.
S&F in repair 15mm bore PVC connection 600mm long both ends screwed with brass cap complete all as specified and directed by the Engg-in-Charge.
S&F in repair 15mm bore bib taps standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed by the Engg-in-Charge.
S&F in repair 15mm bore angle valves of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed by the Engg-in-Charge.
S&F in repair 15mm bore Pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-110gms) complete all as specified and directed by the Engg-in-Charge.
S&F in repair brass CP tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by the Engg-in-Charge.
S&F in repairs 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by the Engg-in-Charge.
Dismantling PVC water tanks of capacity exc 500 but nexc 1000 ltr and removing to store complete all as specified and directed by the Engg-in-Charge.
S&F 1000 ltr capacity rotationally moulded polythene water storage tanks (cylindrical vertical with closed top) multilayers of approved make hoisted & fixed at position complete all as specified and directed by the Engg-in-Charge.
Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 20mm dia pipes complete all as specified and directed.
Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 25 mm dia pipes complete all as specified and directed.
S&F 20mm outer diameter 3-layer PP-R (polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UVstabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed by the Engg-in-Charge.
All as per Srl item No. 61.00 above but 25mm outer diameter complete all as specified and directed by the Engg-in-Charge.
S&F in repair 25mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed by the Engg-in-Charge.
Taking down PVC pipe, eaves and gutters (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by the Engg-in-Charge.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by the Engg-in-Charge.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed in walls complete all as specified and directed by the Engg-in-Charge.
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by the Engg-in-Charge.
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed in walls complete all as specified and directed by the Engg-in-Charge.
S&F 110 mm bore PVC (SWR) bends with oval access door any radius complete all as specified and directed by the Engg-in-Charge.
S&F 75 mm bore PVC (SWR) bends with oval access door any radius complete all as specified and directed by the Engg-in-Charge.
S&F 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal with oval acess door complete all as specified and directed by the Engg-in-Charge.
S&F 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal with oval acess door complete all as specified and directed by the Engg-in-Charge.
S&F 75 mm bore PVC (SWR) vent cowl complete all as specified and directed by the Engg-in-Charge.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework complete all as specified and directed by the Engg-in-Charge.
M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:4 complete all as specified and directed by the Engg-in-Charge.
M&L for stone masonry walling of random rubble, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and directed by the Engr-in-Charge.
Demolition of cement concrete (reinforced) of any description and in any position complete all as specified and directed
M&L for precast cement concrete type B-1 (1:2:4) using 20mm graded stone aggregates as in lintels, landings, coverslabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete all as specified.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, ending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Angle Iron (and FI ,staging for water tank and the like including caps bases splices etc built up from two or more beam or channel section angle with plate including all lattice bars stiffenes gusset plate etc (Fe-290quality A).
M&L for preparing previously untreated steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint over one coat of redoxide primer including preparation of surface.
S&F 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap bent to curve, with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in roof, wall etc complete all as specified and directed.
All as per Srl item No. 83.00 above but except sheeting.
M&L for preparing old steel surfaces of any description over 10cm width/girth and applying one coats of synthetic enamel paint complete all as specified and directed.
M & L for coloured glazed ceremic tiles in vertical surfaces 450X 350X 7mm thick, set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15mm thick rendering in CM (1:4) complete all as specfied and directed.
S&F 20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars,window cills,cooking platforms and like in cement mortar(1:4) including pointing in white cement(1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM (1:4) complete all as specified and directed.
M&L for Three coats of white washing on old plastered surfaces of walls including preparation of surfaces.
S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks, or galvanised wire staples including etc complete all as specified.
Taking down cement plaster on brick or stone walls, etc. including raking outjoints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M & L for colored joint free Non - skid Ceramic tiles 9 to 10mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
M & L for Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc.
M&L for Point wiring for light/fan/bell with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point or bell/buzzer point controlled by one switch.
All as per Srl item No. 93.00 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board.
All as per Srl item No. 93.00 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board.
S&F Switch piano flush type 5 Amps, single pole one way.
S&F Switch socket combination 2 in 1, and 3 and 2 pin, 5 Amps flush type.
S&F Switch socket combination 2 in 1, 5 and 15 Amps flush type.
M&L of ceiling rose on PVC square blocks surface bakelite 3 terminal complete all as specified and directed.
S&F LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F in replacement LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 12 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed.
S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 4 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed.
S&F in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 40 to 63 Amp in the MCB DB complete with connection testing Complete all as specified and directed.
S&F in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 32 Amp in the MCB DB complete with connection testing Complete all as specified and directed.
S&F in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SP 5 to 32 Amp in the MCB DB complete with connection testing Complete all as specified and directed.
S&F LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp
M&L for submain wiring comprising single core, 2 Runs of 4.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including min 2mm thick PVC Casing Caping ISI Marked(heavy duty) and its fittings on surface/recessed complete including 1X4.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS including taking down old UNSV submain wiring and making good the disturbed surface complete all as specified and directed by Engr-in-Charge. (Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
M&L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm×6.0mm thick, buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and connected to main switch board or equipment, including watering arrangement with GI medium grade 20mm bore watering pipe with funnel and wire mesh with PCC chamber CI cover with frame including 15mm dia GI pipe light grade for protection of earthing lead etc including necessary excavation in any type of strata, returning, filling, removal of soil outside MD land, filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to earthing test point all as specified or indicated including testing on completion. Notes : (i) Earth continuity conductor including protection pipe upto 7.5 meters from earth electrode will be include in unit rate, (ii) Arrangement for earth resistance test should be carried out by the contractor. No extra payment shall be provided for the same.
S&F in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250 mm including making arrangement for fixing Complete all as specified and directed.
S&F in replacement1100 volts grade heavy duty 16 Sqmm 2 core flat cable PVC insulated aluminium standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed.
S&F in replacement exhaust fan made of sturdy Engineering Steel body complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of 450 mm sweep heavy duty including making arrangement for fixing Complete all as specified and directed.
Supply & laying or fixing and testing cross linked polytehylene (XLPE) LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 16 Sqmm 4 core and conforming to IS-7098(Part-I-1988 & as per latest amendments), laid in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles including taking down of existing cable complete all as specified & directed.
S&F GI tubing light grade 40 mm bore as in cable protection fixed to poles/walls or laid intrenches/under road crossing etc. all as specified and as directed.
Excavation in trenches, hard/ dense soil not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, not exceeding 10 sqm on plan and not exceeding 1.5Mtr in depth & getting out of hard / dense soil for taking out cable & laying of cable complete all as specified and directed.
Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Returning filling, including spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified.
Supply & laying or fixing and testing of DWC (Double Wall Corrugated) duct pipe (HDPE) of size 63 x 50 mm laid in trench/ducts/under roads/under hard standing/along poles complete all as specified & directed.
S & F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed.
Note : Deduction for amount of Rs. 83,192.25 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract.
M/S MOHD HUSSAIN (BID ID -3396714)
M/S ALI MOHD AND SONS (BID ID -3396477)
M/S MOHD HASSAN (BID ID -3396914)
M/S Ghulam Mustafa (BID ID -3396408)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .