| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹41.5 L+₹4.0 L (10.5%)Rejected-Finance DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹41.6 L+₹4.1 L (10.9%)Rejected-Finance C 234 ADG P CHENNAI | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹41.7 L+₹4.2 L (11.2%)Rejected-Finance BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹43.0 L+₹5.5 L (14.5%)Rejected-Finance RP IV 23 PUNNAKADAVU JN RAMANTHALI P O KANNUR 670308 | KANNUR | KANNUR | KERALA | 670308 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
2 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2022_MES_522085_1
GE MAINT EZHIMALA 8472
Open Tender
Civil Works
Item Rate
180 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE MAINT EZHIMALA
₹97,000
Yes
17 Aug 2022
5 May 2022
4 Jun 2022
5 May 2022
2 Jun 2022
21 May 2022
7 May 2022 - 14 May 2022
60 days
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Dismantling stone slab and tiles of any description or thickness in floors, landings aprons etc laid, bedded and pointed in any mortar complete all as specified and as directed.
Taking down chowkats with shutter (without taking off shutter from the frame) exc 1.5 Sqm but n.exc 4.00 Sqm each complete all as specified and as directed.
Taking down cement plaster of any description or thickness/ chipping of cement concrete in any situation from brick or concrete surface including raking out of joints, hacking for key scrubbing down with water to receive new plaster complete all as specified and as directed.
Taking down existing water proofing treatment of any description and removing rubbish off the premises complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for cement concrete 1:2:4, type B1 (20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating with liquid water proofing compound, surface finished even and fair etc complete all as specified and as directed. Note:- Liquid water proofing compound shall be measured and paid separately.
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm to roof surface including cleaning surface for laying APP based polymeric membrane minimum weighing 4kg/sqm and minimum 4mm thick reinforced with polyester non woven fabric (wt not less than 160 gms/sqm) by forced application complete all as specified and as directed.
S&F fibre glass reinforced plastic (FRP) door frame of 100mm x 60 mm thick to be laminated with inner core of treatment and outer core of average 2 mm thick FRP with gel coat finish weighing an average of 4 kgs per mtr complete all as specified and as directed.
S&F 30 mm thick factory made door shutter to be made with unsaturated polyster resin moulded to 3 mm FRP laminate for forming hollow rails and styles suitable treated and seasoned rubber wood are to be filled inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels with gel coat finish and with an average weight of 8 kg per sqm complete all as specified and as directed.
S&F aluminum (die cast) body door closer hydraulically regulated designation No 2 universal type suitable for door shutters of 701 to 850mm in width and of weight between 36 to 60 Kg complete all as specified and as directed.
S&F floor door stopper 150mm size aluminium alloy body and tongue double legged, anodised with hard drawn steel spring fixed to door complete all as specified and as directed.
S&F 100mm extruded anodised aluminium alloy handles fabricated type complete all as specified and as directed.
S&F in repairs 100mm anodized aluminium barrel tower bolt of extruded section complete all as specified and as directed.
S&F 100mm butt hinges cast brass, with mild steel hinge pin, bright polished and fixed type B-11 complete all as specified and as directed.
S&F aluminium powder coated frame for partitions, doors, windows, ventilators with one or more rebates including joining cleats for fixing etc.(minimum thickness of powder coating not less than 50 micron) complete all as specified and as directed.
S&F aluminium powder coated door shutter, side hung type aluminium section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. (minimum thickness of powder coating not less than 50 micron) complete all as specified and as directed.
M&L for coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.18 sqm but n.exc 0.38 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles 300x600x7mm / 300x450x 7mm thick in vertical surfaces of stone/brick wall, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick backing coat plaster in CM 1:4 complete all as specified and as directed.
M&L for machine cut granite stone slab 15mm thick of approved colour and shade as in floors laid over 15mm thick screed bed in CM 1:6, and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the slab including grinding and polishing complete all as specified and as directed.
Rounding to edges of stone slabs to one edge, such as in steps and other similar situations complete all as specified and as directed.
S&F in repair vitreous china wash basin, coloured (flat back) 550x400mm excluding pillar tap, but including fixing brackets, cutting for and pinning in ends of brackets complete all as specified and as directed.
S&F in repairs pillar taps for fancy type 15 mm size, cast copper alloy, chromium plated screwed down high pressure screwed for iron pipe & fixed complete all as specified and as directed.
S&F in repair vitreous china, wash down water closet (pedestal pattern), cascade type including flushing cistern with seat cover coloured, closed pattern with flat bottom and cover with chromium plated mild steel or aluminium hinging device fixed with necessary bolts complete all as specified and as directed.
S&F Vitreous china squatting pan "Orissa pattern size 630x450 white with integral foot rest (excluding flushing cistern and flush ipe ) fixed in repair complete all as specified and as directed.
S&F plastic seat cover (colour) closed pattern with flat bottom suitable for EWC including taking down old cover complete all as specified and as directed.
S&F in repair 10 ltrs capacity PVC valveless syphonic action type flushing cistern low level with inlet ball valve, float and handle including brackets complete all as specified and as directed.
S&F vitreous china urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed.
S&F in repair vitreous china urinal partition, coloured with and including all fixing acessories complete all as specified and as directed.
S&F in repairs 15mm bore chromium plated bib taps (fancy type), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes complete all as specified and as directed.
S&F in repair angular stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, chromium plated, fancy type, screwed both ends for iron pipe or for union and fixed, suitable for 15 mm bore pipe complete all as specified and as directed.
S&F urinal spreader of brass chromium plated and flush cock (lever type) 25mm complete all as specified and as directed. Make:- Cat Part No. KBEA -32 of Prayag or equivalent in Cera/Parryware/Jaquar.
S&F in repair 15mm bore stop valves chromium plated cast copper alloy (long shank, fancy type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes (concealed type) complete all as specified and as directed.
S&F in repair 125mm size brass chromium plated shower rose complete all as specified and as directed.
S&F in repair brass chromium plated towel ring complete all as specified and as directed.
S&F in repair 20mm dia,D type, 60cm long cast copper alloy, chromium plated towel rail complete all as specified and as directed.
S&F in repair cast copper alloy, chromium plated toilet paper holder complete all as specified and as directed.
S&F in repair chromium plated soap tray fixed with CP brass screws complete all as specified and as directed.
S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and as directed.
S&F in repairs 32mm dia PVC flexible waste pipe for urinals/WHB/sink complete all as specified and as directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S&F in repair cast copper alloy, chromium plated waste coupling with long shank, half thread, 32 mm dia for WHB etc. complete all as specified and as directed.
Taking up or down steel tubing and connections 20mm dia complete all as specified and as directed.
Taking up or down steel tubing and connections 25/32 mm dia complete all as specified and as directed.
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of 25 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Dismantling CI soil waste pipe 100mm/75 mm dia including all joints and branch pieces jointed in cement mortar complete all as specified and as directed.
S&F in repair PVC (SWR) pipes of 100 mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F in repair PVC (SWR) pipes of 75mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F PVC (SWR) pipes of 75mm bore double socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F PVC (SWR) bends any radius of bore 75mm complete all as specified and as directed.
S&F PVC (SWR) bends any radius of bore 110mm complete all as specified and as directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal of bore 75mm complete all as specified and as directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal of bore 110mm complete all as specified and as directed.
S&F in repair 75mm PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
M&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in gola junction of wall and floor or for settings floor trap/ ‘P’ trap in position and PCC padding in floor complete (Work in foul condition as in shaft) all as specified and as directed.
Cutting out cracks to V-section in existing roofs/terracing/walls, cleaning out, wetting, grouting with cement and sand slurry 1:3 including water proofing compound with staging to work in high altitude etc. complete all as specified and as directed. Note:- WPC shall be measured and paid separately.
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces with integral water proofing compound, surface finished even and fair complete all as specified and as directed. Note:- Integral water proofing compound shall be measured and paid separately.
Supply only intergral waterproofing compound complete all as specified and as directed.
M&L for rendering on fair faces of brick work or concrete surfaces 10mm thick in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering on fair faces of brick work or concrete surfaces 10 mm thick in CM 1:3 in celing finished even and smooth without using extra cement using water proofing compound complete all as specified and as directed. Note:- Integral water proofing compound shall be measured and paid separately.
M&L for providing 15mm thick plaster in CM 1:3 mixed with water proofing chemical of Dr Fixit or Shalicrete 'R' of STP Ltd in the proportion/quantity all as per manufactures instructions. Primer Mix Tarfelt LM STP Ltd (duiluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces. Application of 1st coat of Tarfelt LM of STP Ltd (without dilution with water)@ 1kg/Sqm by brush all as per manufacture's instructions.Laying fiber glass cloth (weight not less then 50 gram/Sqm) over the 1st coat while the coated surface is still sticky.After 6 to 7 hrs interval apply second coat i.e final coat of Tarfet LM of STP Ltd (without Dilution with water) @ 1kg/Sqm by brush as per manufacture's instructions. Providing 10mm thick protective plaster in CM 1:3 mixed with STP No 1 @ 250ml/50 Kg cement all as per manufactures instructions. Carryout ponding test for 48 hrs to ensure water tightness of repaired sunken portion. Note:- Mode of measurement actual area treated (floor and adjoining walls) will be measured and paid.
M&L for applying three coats of white wash on ceiling including preparation of newly plastered surfaces complete all as specified and as directed.
M&L for applying two coats of OBD emulsion over a coat of primer on newly plastered surface including preparation complete all as specified and as directed.
M&L for applying three coats of white wash on ceiling including preparation of old surfaces complete all as specified and as directed.
M&L for applying two coats of OBD emulsion over a coat of primer on old surface including preparation complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring (light, fan and power socket etc) complete (except concealed conduit) including fittings such as switches ceiling roses, pendent, regulators, sockets, earth plug and socket etc and making good matching to the existing colour to the disturbed surface complete all as specified and as directed.
Material and labour for colour code point wiring concealed FRLS PVC insulated and unsheathed cable with 2.5 Sqmm copper conductor single core multistrand 1100 Volt grade conforming to IS 694 drawn through concealed PVC conduit of suitable size of modular GI metal box for modular cover plates to be fixed the switches, sockets, regulators etc. and including 2.5 sqmm earth wire copper insulated wire connected to common earth dolly complete all as specified and as directed.
Material and labour for colour code point wiring conceald FRLS PVC insulated and unsheathed cable with 1.5 Sqmm copper conductor single core multistrand 1100 Volt grade confirming to IS 694 drawn through concealed PVC conduit of suitable size of modular GI metal box for modular cover plates to be fixed the switches, sockets, regulators etc. and including 1.5 Sqmm earth wire copper insulated wire connected to common earth dolly complete all as specified and as directed. Note for item No. 69 & 70:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor. (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iv) Size of copper earth wire must be equal to size of current carrying conductor upto size 16 sqmm.
S&F modular switch one way 6A ,1 module ISI marked 230V,50Hz supply complete all as specified and as directed.
S&F modular switch one way 16A ,1 module ISI marked 230V,50Hz supply complete all as specified and as directed.
S&F modular socket one way 16A ,1 module ISI marked 230V,50Hz supply complete all as specified and as directed.
S&F modular white cover plate with frame1/2/3 module complete all as specified and as directed.
S&F modular white cover plate with frame 6 module complete all as specified and as directed.
S&F ceiling rose 3 terminals PVC isolated body ISI marked base complete all as specified and as directed.
S&F in replacement wall mounted 20 W LED 4 ft batten output lumens greater than 100 lumen/watt,CRI = >60, CCT = >5500, Internal surge protection up to 2KW , Power Factor>0.95 having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver making connection to ceiling rose to fitting with 3 core 1sqmm copper conductor complete all as specified and directed by Engr -in-charge. Make : Crompton TRIM LINE. LDL-20-CDL or equivalent in Philips/Wipro/Havells
Supply and fix exhaust fan heavy duty AC single phase 230/240 volt of size 300mm sweep making connections to ceiling rose to fitting with 3 core 1.5 sqmm copper conductor complete all as specified and directed by Engr-in-charge.
Removing the existing LED light fittings (any type) and refixing the same after tiling work complete all as specified and directed by Engr-in-charge.
Supply and fixing LED down lighter fitting 15 W out put lumens greater than 100 lumens/watt with round shaped surface mounted LED down lighter PMMA diffuser,powder coated white finish housing making connections to ceiling rose to fitting with 3 core, 1 sqmm copper conductor complete all as specified by Engineer-in-charge.
S&F mirror light 14W out put lumens greater than 100 lumens/ watt, CRI=>60, CCT=>5500, Internal surge protection up to 2KW , Power Factor 2 feet making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engr-in-charge.
Supply and fix Bulk head fitting out put lumens greater than 100 lumens/watt oval shape edge-lit LED 10W luminaire comprising of high brightness LEDs making connections to ceiling rose to fitting with 3 core, 1 sqmm copper conductor complete all as specified and directed by Engr-in-charge.
KDR CONSTRUCTION
GMS Builders
RS ENTERPRISES
SANDR
Gates Infra Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .