Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹11.8 L
EMD Value
₹23,600
Closing Date
6 Jan 2024, 5:00 pmClosed
EXECUTIVE ENGINEER JS DIVISION KARSOG
EXECUTIVE ENGINEER JS DIVISION KARSOG
PLWSS JABAN BAGAIN IN GP LOWER KARSOG LAYING JOINTING OF RISING MAIN AND PUMPING MACHINERY
2023_HPIPH_83025_3
HPIPH_KSG_2023_DEC_JABAN
Open Tender
Civil Works - Others
Item Rate
180 days
KARSOG
Please refer Tender documents.
8 documents required · 8 mandatory
₹400
Yes
₹23,600
Yes
16 Jan 2024
1 Jan 2024
8 Jan 2024
1 Jan 2024
6 Jan 2024
1 Jan 2024
1 Jan 2024 - 6 Jan 2024
Amount
Excavation in foundation, trenches ( for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposoited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration unmetalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of engineer-in-charge.
Laying;Jointing and testing in trenches to be levelled to grades IS marked ,GI Pipe flanged pipe of following dia meters conforming to IS 1239-1990(Part II) having minimum wall thickness as per IS code and class of pipes specified below providing and jointed with flanges conforming to table as specified below of BIS 6392-1971 (latest with upto date ammendments )welded at both ends according to relevant IS standard and detailed specifications and provided with nuts and bolts of required size,3mm thick compressed asbestos fiber gasket or synthetic rubber gasket conforming to relevant IS codes including all short pieces,bends tees,and other specials extra made from parent tubes and welded with flanges of tables as applicable to the particular reach and of approved specifications as per site condition including flushing,cleaning,painting and hydraulic testing complete. The pipes and specials shall have galvanised coating as per ISW-4736 with latest ammendments..at following RDs.
Booster Stage RD 0 to 60 Rmt 65mm dia GMS Pipe (H) 4.50 mm thickness Flange 17
1st Stage RD 6 to 90 = 30 Rmt 65mm dia GMS Pipe (H) 4.50 mm thickness Flange 5
1stStage RD 0 to 580 = 850 Rmt 65mm dia GMS Pipe (H) 4.00 mm thickness Flange Table 28
Laying, jointing and testing of GMS pipe bevelled edged conforming to IS:1239 of following size and (M) class in trenches having random lengths of 5-7 mtrs including cost of fabrication of minimum 3 cut bends of required degree. The pipe shall have inside & out side Galvanisation at manufacturer work conforming to IS:4736 (with upto date ammendments). The pipe shall be jointed with circumferencial butt welded joints by electric arc welding with minimum three layers of welds so as to achive the minimum effective thorat thickness and strength of weld conforming to IS: 816-1969 sepecification, by using welding electrodes of 2.50 mm to 6.30 mm of Advani Oerlikon (Ador)- CITOJET / Esab make, conforming to IS:814-1991, at site of work complete in all respects. Each butt welded joint shall be tested with dye-penetration test ( with the kit consisting of 3 sprays of 250 ML each includes (a) Cleaner CL-96 (b) Penetrant PT-97 (c) Developer Div-98 of checkmate make) complete in all respects, including manual / mechanical handling of pipes in all leads and lifts to the entire satisfication of Engineer-in-charge. (The earth work in treches and cost of MS flanges to be measured and paid for separately).
1st Stage RD 0 to 580 = 850 Rmt 65mm dia GMS Pipe (H) 4.00 mm thickness 95% Butt Welded 807.50
(Sumersible Pump Set) Supply of submersible RW pump set confirming to ISO 9906 suitable to handle turbidity upto 100 PPM of KSB / Kirloskar / Sabar / Johnston / Crompton / Kalama make instead of clean water pump conforming to BIS:8034 for 6000PPM or latest suitable for lifting water (latest with upto date ammendments) fitted with bronze impellers / suitable alloye. The pump should be fitted with free flow impellers of bronze / suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS:9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty , isolated from the pump by intermediate casing with double mechanical seal in in oil chamber, grease packed lubricated & provided with stainless steel thrust bearing plate to with stand verticle loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given as below:-
Discharge (Q) 2.62 LPS or 9.43 m3/hrs per set, total Dynamic haed 86.54 meter, LWL in sump well (H) 1358 mtrs, Shaft level 1357 mtrs, Kevek at Duscharge point 1439 meter, Sunction Lift +ve, Discharge head 81mtrs, Static head 81 mtrs
Rising Main Length 90 mtrs, Dia 65mm, Pumping Hours 16 hrs, Altitutde of installation above MSL 650 mtrs Characterstics of water Raw Water with turbidity upto 100 PPM, Temperature 25degree centigrade
Supply , Installation, Testing and Commissioning of Star Delta Starter panel for submersible pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 1 No. pumps (1 working & 1 stand by) each of the rating 7.5 HP through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators. Make JSV APPROVED
Star, Delta and Mains Power Contactors of required ratings as per type-2 co-ordination for 7.50HP starter.
Voltage Protection device to protect panel from over voltage and under voltage.
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.
Multi function meter indicating dofferent parameters like current , Voltage, KWH, PF, THD etc with RS 485 communication Make Aarmation Elactric/MAS/Elle.
Main incomer MCCB/MCB of suitable capacity of L&T/ Schnieder/ABB make on the fedder for pumping set confirming to BIS 2516-1985(Latest edition).
Individual Starter incomer MCCB/MCB of suitable capacity of L&T / Schnieder/ABB make on the feeder for pumping set confirming to BIS2516-1985(Latest edition).
Three phase indicating lamps complete with toggled switches for individual motors conforming to BIS 3452(Part I & II) latest with upto date ammendments.
LED On/Off & Trip indicator and push buttons, Control and power wiring , Power capacitor, Cooling fan 230VAC, Contorl terminal, Bus Bar, i.e. Bolt, insulator, etc.
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.
Control Transformer to provide a stable control voltage to safegaurd the control circuit of all the components from the voltage surges and spikes.
Providing doule flanged cast steel sluice valve, ASA-150 of Leader/BHEL/ Kirlosker/ Kilburn/ GLEd/ Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standerds with upto date ammendments)
Providing double flanged cast steel reflux valves ASA-150 of Leader/BHEL/ Kirlosker/ Kilburn/ GLEd/ Fourses makefor rising main and capable of withstanding normal seat pressure as per BIS standerds with upto date ammendments)
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/PREGA/ precision make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with upto date ammendments.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per IS:2373:1981 with upto date ammendments.
Installation of all the items apparing as per the schematic drawing.
Providing and laying copper PVC insulated armoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electrical equipments as per IS:1554(P-I)1988 or latest with upto date ammendments of siemens /GLOSTER/IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles,flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.
(a) Motor side (From switch to starter and starter to motor
(b) Supply side (From Meter of HPSEB to bus bar and switch)
Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
(Centrifugal Pump Set) Supply of horizontal spindle horizontal radial split casing / and suctions (back pull out arrangement) Single / double / multistage centrifugal pumps or combination of pumps in series / parellel of KSB / Mathur & Platt / Jyoti / Kirloskar / BE / Maxflow / Beaconweir Sabar make conforming to BIS 5659-1970) pump (Latest with upto to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned characteristics with bronze / Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling of electic induction motor/motor of standard make such as Kirloskar / NGEF / Cromption / Siemen / Jyoti / BHEL / GEC / ABB conforming to BIS 325-1978) read as BIS 900- 1972 and IS:12615:2011 with IE-2 specifications (latest upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the data given as below :-
Discharge (Q) 2.62 LPS for each pump , total Dynamic haed 284.36 meter, LWL in sump well (H) 1440 mtrs, Shaft level 1437 mtrs, Levek at Duscharge point 1702 meter, Sunction Lift +ve, Discharge head 265 mtrs, Static head 265 mtrs and Rising Main Length 850 mtrs, Dia 65mm, Pumping Hours 16 hrs, Altitutde of installation above MSL 1400 mtrs Characterstics of water Claer Water with turbidity upto 5 PPM, Temperature 25degree centigrade
Supply, Installation, Testing and Commissioning of Soft starter panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. 1 working & 1 stand by each of the rating 20.00 HP .through Star delta Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicatorsMake: JSV approved
Star, Delta and Mains Power Contactors of required ratings as per type-2 co-ordination for20HP starter.
Voltage Protection device to protect panel from over voltage and under voltage.
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.
Multi function meter indicating dofferent parameters like current , Voltage, KWH, PF, THD etc with RS 485 communication Make Aarmation Elactric/MAS/Elle.
Main incomer MCCB/MCB of suitable capacity of L&T/ Schnieder/ABB make on the fedder for pumping set confirming to BIS 2516-1985(Latest edition).
Individual Starter incomer MCCB/MCB of suitable capacity of L&T / Schnieder/ABB make on the feeder for pumping set confirming to BIS2516-1985(Latest edition).
LED three phase indicating lamps complete with toggled switches for individual motors conforming to BIS 3452(Part I & II) latest with upto date ammendments.
LED On/Off & Trip indicator and push buttons, Control and power wiring , Power capacitor, Cooling fan 230VAC, Contorl terminal, Bus Bar, i.e. Bolt, insulator, etc.
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.
Control Transformer to provide a stable control voltage to safegaurd the control circuit of all the components from the voltage surges and spikes.
Independent Control Panel with Switch Fuse Unit and Fuses of Suitable Amperage to eliminate the KltKat fuses of HPSEB make Siemens/Schnieder/L& T
Providing double flanged cast steel reflux valves ASA-150 of Leader/BHEL/ Kirlosker/ Kilburn/ GLEd/ Fourses makefor rising main and capable of withstanding normal seat pressure as per BIS standerds with upto date ammendments)
Providing double flanged cast steel actuated sluice valve ASA-300 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar make and one step higher than delivery line of pump and capable of with standing normal seat pressure per BIS STANDERED with upto date ammendments)
Providing doule flanged cast steel reflux valves class , ASA-150 of Leader/BHEL/ Kirlosker/ Kartar/ Kilburn/ GLEd/ Fourses make for rising main and capable of withstanding normal seat pressure as per BIS standerds with upto date ammendments)
Providing doule flanged cast steel reflux valves class , ASA-300 of Leader/BHEL/ Kirlosker/ Kartar/ Kilburn/ GLEd/ Fourses make for rising main and capable of withstanding normal seat pressure as per BIS standerds with upto date ammendments)
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/PREGA/ precision make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with upto date ammendments.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per IS:2373:1981 with upto date ammendments.
Installation of all the items apparing as per the schematic drawing.
Providing and fixing double flanged MD/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends,tees,reducers. Increasers with companions flanges matching with the relavant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thickness as per IS:2712:1979 and required number of nuts and bolts as per IS:1364:1983, The pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times tatal head stipulated under item No.12. The size of the various components to be as under:
a) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe
b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe.
c) Common header: One dia higher then delivery of pump will extend upto 5meters from the outer wall of the pump house in the direction to be jointed .
Providing and laying copper PVC insulated armoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electrical equipments as per IS:1554(P-I)1988 or latest with upto date ammendments of siemens /GLOSTER/IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles,flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.
Providing and fixing double loop earthing with GI plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
LOW COST AUTOMATION PLC (Programmable logic controller) with appropriate degital and analog inputs and outputs to give automic command to Star Delta Starter Panel/Energy saving variable Frequency Starter Panel Make Armation Electric/Bechoff Automation/Rockwell Automation/JSV Approved
Electric relay card 8 channel
SMPS 4.5 Amps to energise PLC System
HMI 7" display monitoring and controlling of centrifugal pumps make JSV Approved/Bechoff Automation/Rockwell
Control MCB for Automation System
Level Sensor to indicate the water level tank remotely
Shielded Data Cable for communication of level sensor with PLC
M/S THAKUR ELECTRICAL & HARDWARE STORE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .