Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.8 LAccepted-AOC PO BINNAGURI PS BANARHAT DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L-1 | Accepted-AOC Being L1 Bidder | |
| 2 | L-2₹31.8 L+₹2.0 L (6.62%)Rejected-Finance | L-2 | Rejected-Finance Being L 2 | |
| 3 | L-3₹32.4 L+₹2.6 L (8.56%)Rejected-Finance NEAR KRIPAN TCP GATE PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L-3 | Rejected-Finance Being L 3 | |
| 4 | L-4₹34.0 L+₹4.1 L (13.7%)Rejected-Finance VILL DURGA NAGAR CHECK POST PO ETHELBARI DIST ALIPURDUAR PIN 735204 WB | ALIPURDUAR | WEST BENGAL | 735204 | L-4 | Rejected-Finance Being L 4 | |
| 5 | L-5₹34.2 L+₹4.4 L (14.6%)Rejected-Finance GARRISON ENGINEER GE NORTH BINNAGURI | JALPAIGURI | WEST BENGAL | 735232 | L-5 | Rejected-Finance Being L 5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Apr 2021, 6:00 pmClosed
GE North Binnaguri
Post Binnaguri Dist Jalpaiguri West Bengal
PROVISION OF GEYSERS AND EXHAUST FANS IN JCOs AND ORS MD ACCN AND CERTAIN REVENUE AND MINOR WORKS UNDER GE NORTH BINNAGURI
2021_MES_430088_1
NIT No. 8701/ 46 / 09 /E8 2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
BINNAGURI
Class D Category ai
8 documents required · 8 mandatory
₹500
Yes
GE North Binnaguri
₹80,000
Yes
17 Apr 2021
12 Mar 2021
5 Apr 2021
12 Mar 2021
2 Apr 2021
27 Mar 2021
Amount
SCHEDULE A CIVIL WORKS Excavating in post holes in soft/ loose soil ( or similar holes) each n exc 0.5 cu.m. getting out, returning,filling in and ramming earth or broken rubble mixed with earth around , in layer not exceeding 25 cm, watering and removing surplus soil to a distance n.exc 50 M complete all as specified.
Material and labour for plain cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Supply and fixed Steel work in rafters, trusses,purlins, post etc. using steel hollow sections conforming to IS-4923-1997 Grade Yst 310 complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240 complete all as specified.
Supply and fixed rolled mild steel in plates ( plain or chequered ) channels, square cut or notched ( ordinary and counter sunk) forming holes , without any attachmentsimilar work conforming to Fe-410-W ( Gde-E-250) quality -B complete all as specified and directed.
Supply and fixed Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
Supply and fixed Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in as in ridges, valley, eaves, etc with self tapping screws as specified.
Supply and fixing aluminium body ( extruded section ) body Door closer hydraulically regulated, designation No. 3, universal type , suitable for door shutters 851 to 1000 mm in width and of weight between 61 to 80kg complete all as specified.
Material and labour for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paint (1st quality) over one coat of red oxide Zinc chrome primer complete all as specified.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes,pier holes,sewage line, UG cables etc. but not exceeding 10 sqm on plan getting out in soft/loose soil complete all as specified.
Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations/mass concrete complete all as specified.
Material and labour for Hardcore of gauge n exc. 63 mm , stone or boulders, deposited , spread and levelled in layer n exc. 15 cm thick, watered and rammed to a true surface complete all as specified.
Material and labour for 75mm thick PCC (1:3:6), type C-2 (using 40 mm graded crushed stone aggregate ) as in plinth protection; pathway / hardstanding etc laid in bays / panels not exc. 2.00 Sqm each including construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and smooth without using extra cement complete all as specified.
Material and labour for plain cement concrete type B-0 (1:2:4), using 12.5 mm graded crushed stone aggregate, 40 mm thick , as in flooring finished even and smooth complete all as specified.
Material and labour for reinforced cement concrete type B-1, 1:2:4 nominal mix (20 mm graded aggregate) as in lintals upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs complete all as specified.
Material and labour for use and waste of form work to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20 cm wide surfaces rough finished complete all as specified.
Material and labour Mild steel bars ( TMT) 8mm dia. and over up to and including 20 mm dia, as in stirrups and other purpose, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with clips complete all as specified.
Material and labour for brickwork with fly ash bricks, old size, having compressive strength 75Kg sqcm, straight or curved on plan excd 6 M mean radius in built in cement and sand mortar 1:6 complete all as specified.
Material and labour for keyed pointing to brickwork in walls or to bricks in cement mortar 1:3 complete all as specified.
Supply and fixed mild steel framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars ; barred iron doors; ladders; framed balusters ; walk ways ; railings; frame work of water tanks and similar work conforming to Fe-290-Gde E-165 complete all as specified and directed.
Supply and fixed rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces,etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening grade Fe-410 (Gde-E-250) quality- A complete all as specified.
Supply and fixed 1.60mm thich mild steel, plain, black sheet in hearths ; covering to door shutters; covering to door chowkhats ( frames); chullah hoods ; water tanks; water troughs; ducts;urinal troughs and funnels, etc. cut to size , edges beaded if directed, holes punched; including round headed screws , clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams, including bending, turning up, mitred angles, stopped ends, outlets , etc. as required complete all as specified.
Returning ,filling in , including spreading , levelling , watering and well ramming in layer not exceeding 25 cm thick in soft/ loose soil complete all as specified.
Removing excavated material (soils) not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for false ceiling with GI powder coated frame work and 4 mm thick E board classic design , non asbesto fibre reinforced cement board , Reinforced Designer Board tiles conforming to IS-14862 and ISO-8336 , of approved texture at all height duly suspended ceiling laid on hot dip galvanised iron imposed grid of size 600 mm x 600 mm, T section / Angle section including cutting holes in brick wall and making good surface with cement concrete 1:2:4 type B-0 / 1:3 cement mortar complete all as specifiedand having following details: (a) 27mm x 27 mm angle 0.55 mm thickness, GI powder coated hot dip galvanised plugged at the rate 600mm centre to centre alongwith the perimeter of wall. (b) 25 mm x 25 mm Tee 0.55 mm thickness, GI powder coated hot dip galvanised as main and cross runner suspended with 1.6 mm dia GI wire suspendrs (not exc. 1.20 mtr length) with adjustable clamps and dash true fastners plugged in RCC slab or angle iron runner of slopped roof placed at the rate 600 mm centre to centre alongwith the perimeter of wall. Note: The work shall be carried out as per manufacturer instruction and as directed.
Roughening surfaces of old concrete floor/ verticle surface by picking, sweeping clean and washing down with water to remove dust etc.and prepare the surface to receive tiles including applying 3Kg/Sqm cement slurry complete all as specified and directed.
Material and labour for Non Skid ceramic coloured tiles (1st quality) 7 to 8mm thick ( square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. over and including 15 mm thick screeding in CM 1:4 complete all as specified ( screed bed shall not be measured and paid separately).
Material and labour for glazed ceramic coloured/ digital print tiles size (300 x 450 mm 6 to 7 mm thick ) as in vertical surfaces such as skirting/dado / riser to steps etc conforming to IS - 13712 grade IB-III set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including cement screed bed / backing layer of 10mm thick in cement mortar (1:4 ) complete all as specified and as directed. ( screed bed shall also deemed to be included in the quoted rate by the contractor ).
Suppy and fixed, powder coated anodised aluminium frame of size 100 mm x 44 mm x 1.50 mm thickness made of Square/tubular Aluminium section for door with one or more rebates jointing cleat for fixing etc and provision of aluminium door shutter (Single/Double shutter) including necessary jointing cleats glazing clips, rubber gasket aluminium anodised snap beading, screws, hold fast, Aluminium hinges 3Nos 200mm long for each shutter, floor stopper, locking arrangements handle, 12 mm thicness particle fixed in panels with aluminium complete all as directed.
Suppy and fixed, powder coated anodised aluminium sections weighing 0.55kg/m imade of Square/tubular Aluminium section for.partition with one or more rebates jointing cleat for fixing etc and necessary jointing cleats clips, rubber gasket aluminium anodised snap beading, screws, hold fast, 12 mm thicness particle fixed in panels with aluminium complete all as directed.
Supply and fixed of Vitreous China bowl urinal, half stall type white including providing and fixing plugs, bedding the urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement and providing grating and union for discharge pipe including 32mm bore PVC discharge pipe complete all as specified and as directed.
Material and labour for reinforced cement concrete type B-1, 1:2:4 nominal mix (20 mm graded aggregate) as in slab , manhole cover complete all as specified.
Material and Labour for rendering 15 mm thick on other than fair face of brick or concrete surfaces finishing surfaces even and smooth without using extra cement in Cement mortar 1:6 all as specified and directed.
Material and labour for rendering 20 mm thick (10+10) in two layers on fair faces of brick work or concrete surfaces , in cement and sand mortar 1:4 using water liquid water proofing compound @ 200 ml per bag of cement or as per manufacturer's instructions (WPC shall be apply in second layer and measured and paid separately) complete all as specified top surfaces finished even and smooth without using extra cement complete all as specified.
Supply only Integral liquid water proofing compound conforming to IS-2645-2003 complete all as specified.
Material and labour for preparation of new plastered or unplastered surafces of wall and applying three coats of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of newly plastered or unplastered surfaces of walls and applying two coats of cement base paint, white or tinted over one coat of alkaline resistant primer ( before application of cement base paint) of walls including washing floors, etc. , of drops and splashes complete all as specified .
Supply and fixed angular CP stop cock fancy type, screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified .
Supplying, laying, jointing and testing 15 mm nominal bore dia, galvanized tube, medium grade fixed complete to walls, ceilings or laid in floors etc, any type of pipe including necessary fittings and jointing complete all as specified and as directed.
Supply and fixed 75 mm bore PVC (SWR) pipes single socketed ISI marked IS-13592, type 'B in any length with rubber ring joints fixed to walls complete all as specified.
Supply and fixed PVC (SWR) floor trap, plain with grating including jointing with solvent cement, 75 mm dia. outlet complete all as specified.
Supply and fixed PTMT connections 15 mm size with PVC nuts of length 450 mm complete all as specified.
Material and labour for 8 to 9 mm thick vitrified ceramic (square/rectangular) dark shade coloured polished tiles, (1st quality) area of each tiles not exc 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white cement and pigment to match over 15 mm thick screeding in CM 1:6 complete all as specified ( screed bed shall not be measured and paid separately).
Supply and Fixing 5mm thick plain colour solid PVC sheet in strips of width 35 mm single side prelam wood grain for fixing on PVC frame as per specification and drawing as per manufacturer complete all as specified.
Supply and fixed 1.50 mm thick decorative laminate type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per maker's instructions on existing flush shutter including taking down and refising of shutter at work site complete all as specified.
ELECTRIFICATION WORKS Material & Labour for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundn terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be sone through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for one light / fan point / exhaust point controlled by one 5 Amps one way switch complete all as specified and as directed for light /fan point controlled by one way switch 5/6 amps. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
Supply and fixed switch piano flush type, single pole , 6 Amps, one way complete all as specified.
Supply & fixed ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
Supply and fixing heavy duty exhaust fan 300 mm sweep MS body with antidust painting, 4 blade with heavy duty motor and double ball bearing, 1320 RPM, single phase 230/240 volts copper wounds, Air delivery -1600 CMH complete with all accessories as bird guard/ louvers shutters etc incl making connections with 3 core flexible multistranded copper conductor of size 0.75 Sqmm run through flexible pipe all as specified and as directed including cutting holes and making good the disturbed surfaces of walls in CM(1:4) and finishing the surface as per existing color scheme complete all as specified and as drected.
Material and labour for point wiring complete for one socket outlet 15 Amps point on independent board with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles.
Supply, installation, testing and commissioning of electric water heater, storage vertical type, BEE 5 star rated, 25 ltr capacity 230 volts AC, 50 Hz comprising of high wattage heating element for instant heating, extra thick SS inner tank of superior 304 grade, rust & shock proof ABS outer body, non-ferrous pressure plate with & including provision of Pressure relief valve and grouting bolts suitably flushed to wall or any other surface including electric connection with 3 core PVC insulated, sheathed, stranded copper conductor cable/flexible chord complete all as specified and as directed.
Supply and fixed socket combination 2 in 1 , 6 pin , (6 Amps & 16 Amps ) flush type controlled by one switch complete all as specified.
Supply and fixed in repairs, Bib taps, cast copper alloy with crutch handle, screwed for 15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified.
Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE : Two runs of 4 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 2 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed MCB SPN 32 to 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Material & Labour for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including rigid PVC medium grade casing caping (double lock pattern) less that 25mm width and accessories (ISI marked) in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundn terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be sone through proper size copper/brass thimbles. all as specified and as directed for one light / fan point / exhaust point controlled by one 5 Amps one way switch complete all as specified and as directed for light /fan point controlled by one way switch 5/6 amps. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No.57 here-in-before but for one socket out let 5/6 amps point on the independent board
All as per item No.57 here-in-before but One 3 pin 5 Amps socket out let points on same board with other switch.
M&L for point wiring complete for one socket outlet 15 Amps point on independent board with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade casing caping not less that 25mm width and accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles.
Supply and fixed socket outlet 2 in 1, 5 Pin, 5/6 amps, any type complete all as specified and as directed.
Supply and fixed socket outlet 2 in 1, 5 Pin, 5/15 amps, any type complete all as specified and as directed.
Supply and fixed switch piano flush type, single pole , 15/16 Amps, one way complete all as specified.
Supply & fixed stepped type electronic fan regulator flush type 120/280 Volts ISI marked complete all as specified .
Supply and fixed in repairs recessed mounted 2' x 2 ' LED luminaire 34 watts for grid ceiling minimumm lumen output 3300 lumen, pre-treated CRCA frame powder coated with diffused Profied protection IP-65 including necessary connection complete all as specified and directed.
Supply and fixing ceiling fan 1200 mm sweep, 230 volts AC 50 Hz, metal body with BEE 5 STAR rating comforming to IS-374-1979 including necessary connection with prewired 3 core flexible multistrand copper cable complete all as specified.
Supply, installing, commissioing and testing , split type Air Conditioner of capacity 2.0 TR with with hermatically sealed unit complete with dual system i.e. Cooling and with PCB and remote operation on (R-410 A refrigerant ), built in air ioniser and plasma filter for better indoor air quality, electric driven , suitable for working on 230 volts, single phase, 50 Hz supply, (5 STAR Rating invertor type all weather) complete including providing required copper piping, insulation etc, cutting of wall, powder coated steel brackets and making good disturbed surface of wall etc and remote operation complete all as specified and directed .
Supply and fixed 5kVA automatic Voltage stabliser automatic boost / buck transformer for low and high voltage with electronic transistorised relay / time relay for two min, single phase, naturally air cooled, indoor type wall mounted, designed to give output voltage 230V + 2.5% at input range between 170 to 250 Volts complete all as specified.
Supply and fixed epoxy powder coated sheet metal enclosures with socket plug top and MCB , Single pole and neautral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 32 Amps, 240 Volts, 'C' series current carrying capacity 10 KA , including necessary connection complete all as specified and directed.
Supplying and fixing 20 mm nominal bore dia, 3mm wall thickness PVC pipes of pressure rating 10 kgf/sqcm fixed with MS flat iron clamp of size 20 x 3mm at every 1.5 m length of pipe with nuts and bolts fixed to pole /walls, complete all as specified and as directed.
M/S. JAGDISH PRASAD AGARWALA
R K AGARWAL
Shri Satpal Singh
Shri Amarnath Sah
BINOD TRADING CO.
samrat saw mill and joinery workshop
S B Enterprises
M/S East India Traders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .