Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC AWARDED DUE TO L1 | |
| 2 | L2₹33.8 L+₹1.9 L (6.05%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO L2 | |
| 3 | L3₹41.1 L+₹9.3 L (29.2%)Rejected-Finance | L3 | Rejected-Finance REJECTED DUE TO L3 |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
29 Mar 2021, 6:00 pmClosed
G E SHIKARGARH
Military Engineer Services, Garrison Engineer, Shikargarh, Near ASC Supply Depot, Ratanada Jodhpur-342011
CERTAIN REPAIRS TO INTERNAL ELECTRIFICATIONS AND E/M EQUIPMENTS AND INSTALLATIONS AT MH JODHPUR AND DAY TO DAY MAINTENANCE OF INTERNAL ELECTRIFICATION AND ALLIED WORKS IN BSE, SSE AREA UNDER GE SHIKARGARH
2021_MES_429863_1
8684/E8 76
Open Tender
Civil Works
Item Rate
240 days
G E SHIKARGARH JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
G E SHIKARGARH
₹98,000
Yes
11 May 2021
11 Mar 2021
31 Mar 2021
11 Mar 2021
29 Mar 2021
15 Mar 2021
Amount
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed.
M&L for point wiring (Concealed modular) complete for one light point / fan point / exhaust fan point / bell point controlled by one 1-way switch / bell push, with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers with and including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches / sockets etc and making good surface by wall panelling etc, complete all as directed. Make of Wire : RR Kable/ C&S / Finolex / Havells / Anchor. Note : 1. The cost of modular type Metal flush boxes and modular accessories like inner/outer cover plates etc is deemed to be included in quoted rate. 2. The cost of cutting chases on wall and making good surface on wall are deemed to be included in the quoted rate
All as per srl item no. 3 here-in-before but for one socket outlet 3 pin, 5 Amps on independent board.
All as per srl item no. 3 here-in-before but for one socket outlet 3 pin, 5 Amps on same board.
All as per srl item no. 3 here-in-before but for one light point controlled by two 2-way switches
All as per srl item no. 3 here-in-before but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire complete all as specified and directed by Engr-in-Charge
S & F Modular switch 1 way 6A , 1 module size complete all as directed.
S & F Modular switch 2 way 6A , 1 module size complete all as directed.
S & F Modular switch 1 way 16A , 1 module size complete all as directed.
S & F Modular Bell push way 6A with 2 module size with indicator complete all as directed.
S & F Modular Socket , 6 A , 5 Pin , 2 module size complete all as directed.
S & F Modular Socket , 6 A / 16 A , 5 Pin , 2 module size complete all as directed.
S&F of modular type regulator 2 module A/C 240 Volts.
S&F of modular type regulator 1 module A/C 240 Volts. ----------------------------------------------------------------------------------------------------------Note: For item No 08 to 15 above Make of Modular switches / sockets and other accessories : Anchor (Woods) / Legrand (Myrius) / Havells (Crabrtee)
M&L for point wiring (Concealed Normal) One light / fan / bell / exhaust fan point controlled by one no, 1-way, 5 Amps switch complete with single core FRLS PVC insulated, unsheathed, multi stranded copper conductor cables 1.5 Sqmm 1100 volts grade, with and incl 1.5 Sqmm FRLS PVC insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, complete wiring drawn through & PVC casing and capping of 25 mm and above (as per conductor run ) medium grade, ISI marked, incl all accessories & fittings / junction boxes / inspection covers etc, with and incl concealed MS sunken box of suitable size flush with wall surface, covered with & incl 3 mm thick bakelite, laminated hylem sheet / Gang box for top cover suitable for fixing of piano type switches / sockets etc, complete all as specified and directed for the following :- (Note : The cost of MS sunken box with 3 mm thick bakelite, laminated hylem sheet top cover is deemed to be included in quoted rate.) Make of wire : RR Kable/ C&S / Finolex / Havells / Anchor
All as per item No 16 above but for one light point controlled by two nos, 2-way, 5 Amps switch.
All as per item No 16 above but for one socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch.
All as per item No 16 above but for one socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch.
All as per srl item no. 16 here-in-before but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point.
S&F of Switch piano type, single pole, one way, 5 amps, 230 volts, complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal
S&F of Socket, two-in-one, 5 pin, 5 Amp, universal type, 230 volts, complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal
S&F of Switch piano type, single pole, one way, 15 amps, 230 volts, complete all s specified and directed. Make : SSK / Havells (Reo)/ Gold Medal
S&F of Socket, 6 pin, 5/15 Amp, multipurpose shutter type, 230 volts, complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal
S&F of Switch piano type, single pole, two way, 5 amps, 230 volts, complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal
S&F of resistance type regulator A/C 240 Volts. Make : Gold Medal / Havells (Reo) / SSK
S&F of Bell push, flush type 5 amps, 230 volts. Make : SSK / Havells (Reo) / Gold Medal
S&F of electric call bell ding dong AC 230 volts Single Pole. Make : Gold Medal / Havells / Crompton
S&F of Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed. Make : Havells / SSK / Gold Medal
S&F of Lamp holder, metal cased, bakelite body, 230 volts, complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal
S&F LED lamp 9/10W complete all as specified and directed by the Engineer-in-Charge. Make : Havells / Crompton / Philips
S&F of wall mounting light fitting City 2 and incl suitable size 9W retrofit LED bulb and making necessary electric connection, complete all as specified and directed. Make : Havells City 2 / Philips / Crompton
S&F of wall mounting light fitting, Decorative type, wall mounting, SS finish fixture with opal glass diffuser suitable and incl suitable size 9W retrofit LED bulb and making necessary electric connection, complete all as specified and directed. Make : Havells / Philips / Crompton / Wipro
S&F of 20W LED tube light (tube rod), 6000K 4 feet and making connection of tube light fitting all as specified and directed at site. Make : Havells cat part No LHEXCEP7UN1W020 / Compton Greeves / Wipro / Philips
S&F of Batten for LED tube light retrofit G-13 Pattern 4 feet, fitted into the wall / ceiling complete all as specified and directed at site. Make : Havells cat part No LHFXCEP1TN1W020 / Compton Greeves / Wipro / Philips
S&F of LED light fitting 1 X 9/10 watt (2 feet), decorative ultra slim type, with driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed. Make : Havells / Crompton / Wipro / Philips
S&F of Energy efficient round surface mounted polycarbonate fixture circular panel 7W LED 6500K down lighter with premium white powder coating and die cast aluminium and making necessary electric connection complete all as specified and as directed by Engineer-in-Charge. Make : Philips / HAVELLS / WIPRO / CROMPTON
S&F of surface mounted LED light fitting of 2' x 2' size, suitable for false ceiling, 30 Watt, 6000K white light, metal body with white colour outer finish and acrylic diffuser including LED driver / transformer, spring loaded clips for easy mounting and making all electric connections complete all as directed. Make : Crompton / Havells / Philips / Wipro / CG
S&F of bldg security LED Light Luminaire of 25 Watts having IP 65 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with fixing of GI pipe 40 mm band including drilling holling nuts & bolts 2 code of red oxide paint on GI pipe and fixing with wall security light on building wall complete all as specified and directed. Make : Philips / Crompton / Wipro
S&F of PVC ventilating fan 200 mm sweep plastic body including louvers with cutting chases on brick wall and grounting with nut bolts on aluminium frame complete all as specified and directed. Make : Crompton / Havells / Orient Note : Rates are deemed to be included for cutting chasing on wall or window, grouting with nut bolts etc
Taking down old FTL fitting, recessed mounted light fitting and Fixing only with LED Tube/recessed light fitting, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed. Note : LED T/L fitting & LED recessed mounted light fitting shall be issued under Sch 'B' free for fixing only
Taking down old unserviceable 5/15Amp, Switches / Sockets, Bulb Holders and re-fix new 5/15A switches / Sockets, Bulb Holders, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed. Note : Switches / Sockets / Bulb Holders shall be issued under Sch 'B' free for fixing only
Taking down old unserviceable MCBs and re-fix new MCBs, complete with all accessories and making necessary electric connection MCB / cable to MCB, complete all as specified and directed. Note : MCB shall be issued under Sch 'B' free for fixing only
Taking down old unserviceable MCB DBs and re-fix new MCB DBs, concealed flush to wall and necessary cement work will be done and and incl cutting chasing and making good of disturbed surface of wall as original by brick work, plastering, white washing, OBD etc as required good surface, complete with all accessories and making necessary electric connection, complete all as specified and directed. Note : 1. DBs shall be issued under Sch 'B' free for fixing only 2. The cost of cutting chases, Brick work, Plastering, White washing, OBD on wall and making good surface on wall are deemed to be included in the quoted rate.
Attending electric complaints for any type of COVID-19 wards at MH area, to check the existing electrical items / points for serviceability of continuous electric supply, rectifying No light complaints including carrying out minor repairs / replacement etc as required to make the item functional and replacement of small pieces of wire, screw, refixing of hanging wires / Light fittings / ceiling fans / exhaust fans, DBs and switch boards etc all as specified and directed by Engr-in-charge. (i) Any other replacement of major items shall be measured & paid separately under respective items of this schedule. (ii) Electrician will ensure to wear complete PP Kit before enter into a COVID ward and use sanitizer regularly. (iii) Contractor will deploy one electrician with helper (keeping necessary electric tools & safety equipments) to attend electric complaints into various COVID wards (Like Family ward, Officers ward, JCOs/OR ward, OT, Lab, etc.,) at MH Jodhpur. (iv) In case Contractor fails to deploy electrician for any complaint, penalty @ Rs. 500/- per complaint shall be recovered from the Contractor
S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified cat No 507811 Make : Legrand / Havells / ABB
Taking out old worn out wooden frame / steel frame and supply & single door sheet metal borad complete with flush door handle with locking arrangement painted with powder coated finishing with necessary PCC work complete size 1000x1000x300 Make : BCH Cat Part No BIL 50540 or Equivalent make in Hensel
All as per srl item no. 47 here-in-before but size 800x800x300 Make : BCH Cat Part No BIL 50310 or Equivalent make in Hensel
S&F of Vertical Distribution Board, double Door, suitable for 'A' Frame FP MCCB 100A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 4 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface and making good disturbed surfaces as per existing, complete all as specified and directed. Make : Havells Cat Part No DHDLVSRWGOFO04 / Schneider Elect / Legrand / ABB Note : MCCB & MCB will be measured and paid separately under respective items
S&F of Distribution Board, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 08 way (Concealed flush to wall), 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface and making good disturbed surfaces as per existing, complete all as specified and directed. Make : Havells / Schneider Elect / Legrand / ABB / Hager
All as per item No 50 here in before but SPN 4 way (Concealed flush to wall), Distibution Board
S&F of MCCB, A Frame, thermal adjustable magnectic setting, Ics = 75% 25 kA, 415V, 125 Amp, 4 Pole MCCB with over load and short circuit protection, complete all as directed. Make : Havells Cat part NoIHLASF0125 # / Schneider Elect / Legrand / ABB / Hager
S&F of MCCB, A Frame, thermal adjustable magnectic setting, Ics = 75% 25 kA, 415V, 100 Amp, 4 Pole MCCB with over load and short circuit protection, complete all as directed. Make : Havells Cat part NoIHLASF0100 # / Schneider Elect / Legrand / ABB / Hager
S&F of MCB, C Curve type, 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as directed. Make : Schneider Elect / Legrand / ABB / Havells
S&F of MCB, C Curve type, 10 kA, 40Amp, SPN with over load and short circuit protection, complete all as directed. Make : Schneider Elect / Legrand / ABB / Havells
S&F of MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as directed. Make : Schneider Elect / Legrand / ABB / Havells
S&F of GI pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint complete all as directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
Taking down old sub main wiring and M&L for concealed sub main wiring with 2 run of 10 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and one run of 10 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 20/25 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : Two run of 10 Sq.mm. and one run of 10 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces. Make of wire : Finolex/Havells/RR Kables, Make of PVC conduit : Finolex/Modi/Polycab.
All as per srl item no. 58 here-in-before but with 2 run of 6.0 sq mm FRLS copper wire with one run 6 Sqmm FRLS copper cable as earth wire.
All as per srl item no. 58 here-in-before but with 2 run of 4.0 sq mm FRLS copper wire with one run 4 Sqmm FRLS copper cable as earth wire.
All as per srl item no.58 here+B77-in-before but with 2 run of 2.5 sq mm FRLS copper wire with one run 2.5 Sqmm FRLS copper cable as earth wire.
Laying only jointing and testing of LT UG cable, XLPE insulated, PVC sheathed, galvanized steel strip armoured electric power cable with stranded aluminium conductor, 1100 volts grade of size 16 sqmm 4.0 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed. Note : 1. UG Cables shall be issued under Sch 'B' 2. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 3. Excavation, earth work, sand cushioning and slab covers will be measured and paid separately under respective items.
All as per srl item no. 62 here-in-before but with 16 Sqmm 2.0 Core
All as per srl item no. 62 here-in-before but with 10 Sqmm 2.0 Core
Excavation in trenches in hard / dense soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out including trimming of sides, complete all as directed.
Supply and laying 40 to 50 mm thick roughly hammer dressed Jodhpur Zone slab cover 25 to 30 cm wide and not less than 60cm long dry laid, abutting each other gap between adjacent slabs not exceeding 10mm for protection of underground cable complete all as specified
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15 cm after laying of cable in trenches punned down to 10cm above cable complete all as directed and sand cover to under ground cable complete all as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified.
M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed.
Attending of complaints for checking of existing electrical items/points for serviceability for continuous electric supply, rectifying the no light complaints including carrying out minor repairs etc as required to make the item functional and replacement of small pieces of wire, screw, refixing of hanging wiring/wires and boards etc all as specified and directed by Engr-in-charge. NOTE:- (i) Any other replacement of major items shall be measured & paid seperately under respective items of this schedule. (i) Any other replacement of major items shall be measured & paid seperately under respective items No 72 to 89 and 98 to 106 here in after of this schedule. (b) Repairing of 4 points without any material (may be at different locations) will be considered as one unit and for more than 4 points at a time will be considered as two units. (ii) Contractor will deploy four electricians with helper to attend complaint in Shikargarh Enclave Married Accomodation , Shikargarh OTM Accomodation,Sugan Enclave Married Accomodation and Bahadursingh Enclave Married Accomodation with necessry tools, safety equipments and transportation required to attend complain. (iii)Seperate complaint slip will be issued to Electrician for Shikargarh Enclave Married Accomodation , Shikargarh OTM Accomodation,Sugan Enclave Married Accomodation and Bahadursingh Enclave Married Accomodation. Complaint will be attended on same day includind Sunday and holiday as directed by engineer in charge. (iv) Each complaint slip restricted to maximum 10 nos of complaint for each enclave and for complaint above 10 nos complain for each area(Shikargarh Enclave Married Accomodation , Shikargarh OTM Accomodation,Sugan Enclave Married Accomodation and Bahadursingh Enclave Married Accomodation) will be given separate complaint slip. (v) Necessary security passes for manpower employed by contractor will be responsibility of contractor and copy of necessary document(Mil Pass, Educational Certificate/Experience certificate, Indentity Card) Should be submitted by contractor to Engr-in-Charge at the time of comissment of work. (vi) If contractor fails to depute electrician with helper for any pocket for attending complaint for any day, penal recovery of Rs 1000 will be deducted from RAR (vii)Sufficient store as directed by Eng in Charge will be procured by contractor and hand over to JE E/M for day to day issue. (viii) Makes of switches/sockets shall be SSK/Anchor/CONA/Havells or as per existing make.
Supply only Switch Piano type one way 5amp ISI Marked
Supply only Switch Piano type Two way 5amp ISI Marked
Supply only Switch bell push 5 Amps, flush button type, SP, one way, 230 Volts .
Supply only socket out let multipurpose 3 pin 5 Amps, flush type, 230 / 250 Volts
Supply only socket outlet , 5/15 amps, flush type, multipurpose, 230 / 250 volts
Supply only Switch socket combination multipurpose 3 pin 5 Amps, flush type, 230 / 250 Volts
Supply only Switch socket combination , 2 in1, 5/15 amps, flush type, universal 230 / 250 volts
Supply only Switch socket combination multipurpose 3 pin 16 Amps, flush type, 230 / 250 Volts
Supply only Switch socket combination multipurpose 5/16 Amps, 5 in 1 flush type, 230 / 250 Volts
Supply only Ceiling rose surface bakelite 65 x 50 mm three terminals
Supply only Electronic fan regulator 230 volt, step type,socket type ,hum free 120 watt
Supply only Bell Multi Music type elecritic, 230volts.
Supply only Capacitor 2.5 mfd
Supply only Modular switch 6 Amp 250 V AC one way one module
Supply only Modular switch 16 Amp 250 V AC one way with indicator one module
Supply only Modular switch 2 way 6A, 250 V AC 1 module
Supply only Modular Socket, 6A - 2/3 pin combined 2 module
Supply only Modular Socket 6A/16A - 2/3 pin combined 2 module
Taking down unserviceable ceiling fan/exhaust fan from its position and handing over to occupant for further disposal
Hanging only repaired/new ceiling fan/exhaust fan any make and size held by occupant
Supply only Louvers for 300/450mm sweep exaust fan
Supply only PVC rectangular block formounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep
Supply only PVC rectangular block formounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 x 100 x 50 mm deep
Supply only PVC rectangular block formounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 x 200 mm and 50 mm deep
Supply only PVC rectangular block formounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 x 150 x 50 mm deep
Fixing only LED light fitting 10/18/20/22 watt
Fixing only recssed mounted light any type and description
Supply only Modular cover plate with frame 6 module.
Supply only Modular cover plate with frame 4 module.
Supply only Modular cover plate with frame 3 module.
Supply only Modular cover plate with frame 2 module.
Supply only Modular cover plate with frame 1 module.
Supply only Modular metal flash box 6 module.
Supply only Modular metal flash box 4 module.
Supply only Modular metal flash box 1/2 module.
Supply only DB double door, TPN 415V, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 A complete all as specified and directed including taking down unserviceable DB. Note : Rates are deemed to be included for flashing in wall concealed complete making good and matching existing surface. Make :- Havells/L&T/Legrand/ABB
Supply only sheet metal enclosures double door, single pole and neutral, 08 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating complete all as specified and directed. Note : Rates are deemed to be included for flashing in wall concealed complete making good and matching existing surface. Make :- Havells/L&T/Legrand/ABB
Supply only MCB TPN,63 Amps .415 V in `C’ series having current rating 16 KA complete all as specified and directed. Make :- Havells/L&T/Legrand/ABB
Supply only MCB single pole, 6 - 32 Amps 240V in `C’ series having current rating 10 KA complete all as specified and directed. Make :- Havells/L&T/Legrand/ABB
Supply only MCB SPN, 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed. Make :- Havells/L&T/Legrand/ABB
Supply only meter box Asian or Sintex code no- GSMB2525 of size 250x250x160mm including taking down existing plastic meter box.
Supply only Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed. Make :- Havells/L&T/Legrand/ABB
Supply only PVC insulated 1.5 Sqmm unsheathed copper conductor stranded cable wire 1100 V grade ISI Marked Make : Polycab/Havells/RR Kable
Supply only PVC insulated 2.5 Sqmm unsheathed copper conductor stranded cable wire 1100 V grade ISI Marked Make : Polycab/Havells/RR Kable
Supply only PVC insulated 4.0 Sqmm unsheathed copper conductor stranded cable wire 1100 V grade ISI Marked Make : Polycab/Havells/RR Kable
Supply only PVC insulated twin core flexible 23/0.0076 cable wireunsheathed copper conductor stranded cable wire 1100 V grade ISI Marked Make : Polycab/Havells/RR Kable
M&L for surface point wiring complete in existing PVC Conduit/Pipe using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable upto and incl working voltage 1100volts grade, ISI marked, PVC casing caping/conduit including bend, tee, junction boxes elbows etc incl pressed steel terminal existing sunken boxes covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws and unsheathed copper conductor stranded cable earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly complete including taking down unserviceable and all as specified and directed. (a) One Light point controlled by one switch
Ditto as per item No 118 but One Light point controlled by two way switches
Ditto as per item No 118 but One fan point controlled by one switch
Ditto as per item No 118 but One 5 Amp socket point controlled by one switch (independant)
Ditto as per item No 118 but on the same board.
Ditto as per item No 118 but below board
Ditto as per item No 118 but One bell point controlled by one bell push button
M&L for power point wiring complete using 2.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable upto and incl working voltage 1100volts grade ISI marked, PVC casing/caping/conduit bend,tee,junction boxes elbows etc incl existing pressed steel terminal sunken boxes of size 1.2mm covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws and unsheathed copper conductor stranded cable earth continuity wire connected to DBs/sunken boxes/fittings of size 2.5 Sqmm Cross sectional area and all other metal parts with earth dolly includind taking down unserviceable complete all as specified and directed.
S&F in replacement LED tube light fitting. 1 x20W flameproof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make : Sudhir/Bajaj/Havells or equivalent
S & F in replacement of unsv volt meter panel mounting type of size 96 mm x 96 mm range 0 to 500/400 Volts AC.Make :AE/L&T /MECCO.
S & F in replacement of unsv ammeter panel mounting type of size 96 mm x 96 mm range 0 to 400 Amps with CT coil including. Make :AE/L&T /MECCO.
S & F in replacement of unsv neon type indicator lamp switch by various colour 230 V AC suitable size to match the existing.
S & F in replacement of unsv HRC Fuse link Din type, size 0 200 Amps, 415 Volt AC 50 Hz Cat No-SF94132 Make: L&T or equivalent C&S/Legrand
S & F in replacement of unsv HRC Fuse link Din type, size 2, 400 Amps, 415 Volt AC 50 Hz Cat No-SF94235 Make: L&T or equivalent C&S/Legrand
S & F in replacement of unsv HRC Fuse link Cylindrical type, size 14x51, 63 Amps, 415 Volt AC 50 Hz Cat No-SF90159 Make: L&T or equivalent C&S/Legrand
S & F in replacement of unsv HRC Fuse link Cylindrical type, size 14x51, 32 Amps, 415 Volt AC 50 Hz Cat No-SF90142 Make: L&T or equivalent C&S/Legrand
Supply & Fixing in replacement of Unsv MCCB 400 Amps 4 Pole breaking capacity 35/36 KA,415 V,Adjustable type Make : L&T/Legrand/ABB/Havells
Supply & Fixing in replacement of Unsv MCCB 320 Amps 4 Pole breaking capacity 35/36 KA,415 V,Adjustable type Make : L&T/Legrand/ABB/Havells
Supply & Fixing in replacement including taking down unsv MCCB 250 Amps 4 Pole breaking capacity 36 KA,415 V,Adjustable type Make : L&T/Legrand/ABB/Havells
Supply & Fixing in replacement including taking down unsv MCCB 160 Amps 4 Pole breaking capacity 25 KA,415 V,Adjustable type. Make : L&T/Legrand/ABB/Havells
Supply & Fixing in replacement including taking down unsv MCCB 200 Amps 4 Pole breaking capacity 36 KA,415 V,Adjustable type.Make : L&T/Legrand/ABB/Havells.
Supply & Fixing in replacement including taking down unsv MCCB 125 Amps 4 Pole breaking capacity 25 KA . Make : L&T/Legrand/ABB/Havells
S&F in replacement including taking down unsv MCB 415 volts TPN 32 to 63 amp 10KA breaking, capacity, ISI marked.Make : L&T/Legrand/ABB/Havells or equivalent
M&L in replacement copper bus bar rating 400 Amps 25/3mm including making whole suitable for panel with tape insulation of suitable colour in Phase RYB & neutral in Black colour complete all as specified and as directed by Engr-in-Charge,
M&L in replacement aluminium bus bar rating 800 Amps 25/6 mm including making whole suitable for panel with tape insulation of suitable colour in Phase RYB & neutral in Black colour complete all as specified and as directed by Engr-in-Charge,
M&L for dressing of XLPE electrical cable of any size and capacity nearby the LT Panel after disconnecting all incoming and outgoing connection complete including cleaning of grass nearby the LT Panel upto 2mtr all around , necessary earthwork as required all as specified and as directed by Engr-in-charge. (Note :( i) If aluminium socket and lux required to replace during the work, Rate of aluminium socket and lux of any type & size required at site are deemed to be included in the quoted rate) (ii) Rate of necessary earthwork as required at site are deemed to be included in the quoted rate)
Earthing complete with galvanized steel earth plate 600 x 600 x 6mm thick buried directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5mr below normal ground level connected to galvanized iron strip of size 25 x4 mm by means GI welding after tighten by bolts, nuts, check nuts and washers from earth pit to test point with protection GI pipe of size 40 mm dia light grade and providing masonry enclosure and watering pipe of dia 40mm including wire mesh steel funnel, including watering arrangement 200 ltrs for each earth pit complete as specified and directed by Engr-in-charge . Make of GI Pipe is Prakash/Jindal (Note : GI strip 7.5 mtr included in the quoted rate from earth pit to test point)
Earthing complete with galvanized steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less 'than 1.5 meters below normal ground level, connected to galvanized earth wire 4 Sqmm Size means of bolts, nuts, check nuts and washers of galvanized iron or steel check nuts and washers of brass including necessary earth work, PCC chamber , CI cover with frame, funnel, mesh, Earth lead protection pipe, 7.5 Meter Earth Lea etc all as shown in electrical plate No 5 in SSR Part-I and connected to earth test point/LT Panel/Transformer including testing on completion all as directed by Engr in-Charge
M&L for load balancing of three phase system at Main LT Panel upto Sub LT Panel of any size and capacity complete including disconnecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium thimble of any size and capacity all as specified and as directed by Engr-in-charge. Note : (i) Necessary eqpt and safety measures, stationary reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium/Copper tube terminal of any size as per site reqmt change under the job deemed to be included in the quoted rate
M&L for load balancing of Single/three phase system at LT Panel upto Distribution box/Bldg Main supply of any size and capacity complete including disconnecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium tube terminal of any size and capacity all as specified and as directed by Engr-in-charge. Note : (i) Necessary equipments and safety measures, stationery and T&P required for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium/Copper tube terminal of any size as per site reqmt change under the job deemed to be included in the quoted rate
M&L for taking out faulty XLPE LT Cable of size 16 sqmm to 70 Sqmm x 3.5/4 core and repair the same with straight through Joint (Tublar sleeve version) including suitable size of line connector complete all as per directed by Engr-in-charge. Note : Cost of necessary excavation and earth work , labour, Jointing kit complete, fixing charges & T&P including removing of grass/shrubs nearby the fault location will be deemed to include in quoted rates.
All as per item No 27 above but XLPE LT Cable of size 95 sqmm to 240 Sqmm x 3.5 core
Servicing of DG SET of 200 KVA, make Kirloskar at New MH for repair/replacment of the following components all as specified and directed by Engr-in -charge. (a) Checking water temperature safety control (b) Checking and correcting up impeller of water pump for excess play. (c) Checking and correcting turbocharger oil leakage,tightening of mounting screws and nuts (d) Cleaning,tightening all electrical connection of engine (e) Checking and cleaning of generator brushes(Alternator) and commutator (f) Cleaning of entire engine. (g) Checking exhaust and inlet manifold bolts and capscrew (h) Checking engine blow by (i) Cleaning of radiator inside and outside by removing and refixing after cleaning. (j) Checking and adjusting injector and valves. (k) Cleaning fuel inlet connections and screw, (l) Changing of governor oil. (m) Replacing of radiator hoses of different sizes with clamps (n) Checking of vibration damper
All as per item No 29 but for 500/400 KVA DG Set make Kirloskar
All as per item No 29 but for Diesel Engine 55 KWH Make Kirloskar
Supply and fixing oil filter 06.436.01 for 200 KVA DG SET Make Kirloskar as per directed
Supply and fixing Fuel filter 48.117.04 for 200 KVA DG SET Make Kirloskar as per directed
Supply and fixing Fuel filter 48.117.05 200 KVA DG SET Make Kirloskar as per directed
Supply and fixing Air Filter inner Element for 200 KVA DG SET Make Kirloskar as per directed
Supply and fixing Air Filter Outer Element for 200 KVA DG SET Make Kirloskar as per directed
Supply and fixing V- Belt F6.184.01 for 200 KVA DG SET As per directed by Engr-in-Charge.
Supply and fixing V- Belt F6.184.02 for 200 KVA DG SET As per directed by Engr-in-Charge.
Supply, installing and testing 180 AH, 12 V maintanance free Battery for DG Set. Make :- Exide, Okayo/ equivalent
Supply and fixing Oil filter DV0.014.11 for 500/400 KVA DG SET
Supply and fixing Oil filter DV0.014.27 for 500/400 KVA DG SET
Supply and fixing Fuel filter DV0.020.03 for 500/400 KVA DG SET
Supply and fixing Water Saparator DV8.040.24 for 500/400 KVA DG SET
Supply and fixing Air Filter inner Element for 500/400 KVA DG SET Make Kirloskar as per directed
Supply and fixing Air Filter Outer Element for 500/400 KVA DG SET Make Kirloskar as per directed
Supply and fixing V- Belt DV0.016.08 for 500/400 KVA DG SET As per directed by Engr-in-Charge.
Supply and fixing V- Belt DV0.016.23 for 500/400 KVA DG SET As per directed by Engr-in-Charge.
Removing the old engine K-OIL from the diesel engine sump of various DG sets,cleaning the oil sump thoroughly, fill only new engine oil as directed by Engineer -in -Charge. Note: Oil issued under Sch 'B' store
Repair/overhauling of self starter including replacement of worn out clutch assembly,bush,spring,plunger assembly, solenoid switch,carbon brushes,brush spring etc for the DG Set .
Repair/overhauling of dynamo including replacement carbon, brushes holder,spring,commutator/slipring assembly bearing,regulator etc. of any make,type and capacity.
Dismantling the PT/FI pump assembly,repair/overhauling/ calibrating in authorised lab including replacing tornout rings,plunger,damper plate gasket etc. including ,refixing,reconnecting, testing &commissioning complete as specified and directed.
Servicing/repairs of unserviceable AMF panel complete including cleaning resetting/adjustment of relays,calibration of time delay relays, checking and replcement of any item if required like any type relays as per required at site and diods,resistors etc. complete for any make type and capacity of DG sets and make serviceable upto satisfactory as directed by Engr-in-Charge.
M& for servicing 400 KVA capacity of alternator including cleaning of field and armature winding,varnishing and baking polishing of slip rings,checking and making correct excitation system and dressing the all type cable connection etc. complete as specified and as directed by Engineer-in-Charge for alternators of:-
All as per item No 179 above but 500 KVA capacity.
All as per item No 179 above but 200 KVA capacity
Supply and laying, testing , jointing and commissioning XLPE insulated armoured heavy duty electric under ground cable with aluminium conductor 1100 volts grade of size 95 Sqmm 3 1/2 core laid in trenches/fixed to wall or Feeder Pillor including incoming and outgoing connection with proper size of lugs and glands complete all as specified and directed.
Supply and fixing in replacement of Unsv standard duty power factor correction cylindrical type capacitors of Capacity 25 KVAR Make :- L&T Series : LTCCD
Supply and fixing in replacement of Unsv standard duty power factor correction cylindrical type capacitors of Capacity 7.5 to 15 KVAR Make :- L&T Series : LTCCD
Supply and fixing in replacement of Unsv standard duty power factor correction cylindrical type capacitors of Capacity upto 5 KVAR Make :- L&T Series : LTCCD
Supply and fixing in replacement of Unsv Capacitor Duty Contractor Mo C type 5 KVAr Rating 440V 3 Phase 50 HZ
Supply and fixing in replacement of Unsv Capacitor Duty Contractor Mo C type 10 KVAr Rating 440V 3 Phase 50 HZ
Supply and fixing in replacement of Unsv Capacitor Duty Contractor Mo C type 15 KVAr Rating 440V 3 Phase 50 HZ
Supply and fixing in replacement of Unsv Capacitor Duty Contractor Mo C type 25 KVAr Rating 440V 3 Phase 50 HZ
M&L for servicing and cleaning of ACB 1000 A 4 Pole 50 Hz Rating by removing from the main panel by disconnecting all electrical connection, carried out necessary overhaulling , cleaning and servicing and refixing the same after the work completed at existing position with all including minro replacement parts and all necessary connection complete all as specified and as directed by Engineer-in-Charge
Painting of electrical equipments or installations and writing the name on wall/equipment steel sections, rolling shutters etc with two coat of synthetic enamel high glow paint Ist grade including preparation/cleaning of steel surfaces as per directed by Engineer-in-Charge.
S&F line diagram/chart/preventive maint schedule board with steel frame in sub stn/power house/AC/WS Installation made out of 3mm thick perpex sheet marking in different colour including indicating accessories, equipments and fixing arrangement to the walls/equipment all as directed by Engr-in-charge duly computerised. (NOTE : letters shall be given by Engr in charge and the same shall be computerised).
S&F chequired rubber matting of red colour (ISI marked) 1100 V rating of size 2Mx1Mx 12 MM thickness.
M & L for checking and measuring the earth resistance of earthing for lightening arrester, Bldgs and equipment earthing with earth resistance tester with compiling the following -: (a) Adding the water and salt before checking the earth resistance. (b) Tightening of earth strip/wire connection on test point and earth pit. (c) The earth resistance value of all earthing pit should be recorded in resister duly signed by users and MES representative.
Shri Ram Traders Co
chhaba construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .