| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | ₹25.4 L Quoted ₹27.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹27.4 LRejected-AOC 16 12A SWAMIJI ROAD NEAR SABUJ SANGHA KOLKATA WEST BENGAL 700060 UDYAM WB 10 0078972 19CQSPB7095J1Z2 R M MII STATUS AS VERIFIED | KOLKATA | WEST BENGAL | 700060 | ₹27.4 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | TECHNO ENGINEERING L2 | DEVO ENTERPRISE L1 |
|---|---|---|---|---|---|
| 1.00ESP Water Washing: | |||||
| 1.01 | ESP Water Washing | 1 | Lump Sum | 1,75,000 ₹1.8 L | 1,92,952 ₹1.9 L |
| 2.00ESP Inspection & Rectification Job: | |||||
| 2.01 | ESP Inspection and rectification job Inspection of the following:
1. CERM Assemblies (hammer, bearing, shaft), EERM assemblies (hammer, bearing, shaft, gear assemblies), collecting listed above etc.
2. Support Insulator, Torque Insulator, Antisway Insulator, Transformer HV bushing
3. Support insulator heater, Purge air heater, hopper heater (resistance checking from Junction Box), Checking of thermostats
for all the heaters, Hopper Vibrator 4. Replacement and rectification of the following :
a) Replacement &rectification of CERM Hammer assemblies
b) Replacement &rectification of CERM Bearing assemblies
c) Replacement &rectification of CERM Shaft Assemblies.
d) Replacement &rectification of EERM Hammer assemblies
e) Replacement &rectification of EERM Worm Gear Assemblies
f) Replacement &rectification of EERM Shaft Assemblies.
(Insulation along with cladding need to be removed &restored by
Vendor with material supply if required).
g) Replacement &rectification of EERM Bearing assemblies
h) Replacement &rectification of Support Insulator
i) Replacement &rectification of Torque Insulator
j) Replacement &rectification of Antisway Insulator
k) Replacement &rectification of Hopper heater.
(Insulation need to be removed &restored by Vendor with material
supply).
l) Replacement &rectification of Hopper Vibrator.
m) Gearbox overhauling of all 52 nos' of gearboxes.
n) Asbestos Rope change of doors of ESP, insulator box.
o) Alignment checking and rectification of ESP internal if
required.
p) Alignment/Air tightness checking and rectification of All ESP
doors, insulator box doors (If required). [#No air ingress# need to be confirmed after
box up of all doors at the time of AIRLOAD test (with both ID & fd running).} q) Painting of different areas. | 1 | Lump Sum | 17,84,000 ₹17.8 L | 14,79,683 ₹14.8 L |
| 3.00GD Screen Replacement: | |||||
| 3.01 | GD Screen Replacment
GD screen (perforated screen 2&3) replacement of all 4 (four
)inlet ducts need to be done. This includes all required fabrication job. (Material will be supplied by WBPDCL). | 1 | Lump Sum | 3,85,000 ₹3.9 L | 6,29,826 ₹6.3 L |
| 4.00Painting: | |||||
| 4.01 | Painting of different areas
1. ALL MOTOR ALONG WITH CANOPY FOR CERM, EERM
& GDRM (52 Nos)
2. ALL GEAR BOX FOR CERM, EERM & GDRM (52 Nos)
3. ALL SHAFT & SUPPORT INSULATOR HOUSING (96 nos)
4. ALL INSPECTION DOORS (52 nos)
5. ALL ESP TRANSFORMERS (24 Nos)
6. RAILINGS OF ROOF (Total railing of ESP roof)
7. STAIRCASE OF ESP (Staircase of middle & other 2 sides of
ESP)
Consumables Materials like Paint/Red-oxide/Asbestos rope, Hylomer, Adhesive (dendrite, hole tight etc.), Petrol, Kerosene,
Thinner, Gaskets for Support Insulator Housings & Dis-connecting Switch Box etc. under the scope of contractor. | 1 | Lump Sum | 2,75,000 ₹2.8 L | 3,11,332 ₹3.1 L |
| 5.00GD test (optional): | |||||
| 5.01 | GD TEST | 1 | LumpSum | 1,25,000 ₹1.3 L | 1,07,767 ₹1.1 L |
Tender Value
₹24.4 L
EMD Value
₹49,000
Closing Date
10 Jul 2025, 3:00 pmClosed
GM BTPS
Administrative Building, BTPS, Tribeni, Hooghly. PIN-712503
Overhauling of ESP of Unit #5 under AHP(E/M) department, BTPS.
2025_WBPDC_870399_1
WBPDCL/BTPS/NIT/E2633/25-26
Open Tender
Miscellaneous Services
25 days
BTPS
Please refer to the NIT document
5 documents required · 5 mandatory
₹0
₹49,000
Yes
2 Jun 2026
27 Jun 2025
12 Jul 2025
27 Jun 2025
10 Jul 2025
27 Jun 2025
Amount
ESP Water Washing:
ESP Water Washing
ESP Inspection & Rectification Job:
ESP Inspection and rectification job Inspection of the following: 1. CERM Assemblies (hammer, bearing, shaft), EERM assemblies (hammer, bearing, shaft, gear assemblies), collecting listed above etc. 2. Support Insulator, Torque Insulator, Antisway Insulator, Transformer HV bushing 3. Support insulator heater, Purge air heater, hopper heater (resistance checking from Junction Box), Checking of thermostats for all the heaters, Hopper Vibrator 4. Replacement and rectification of the following : a) Replacement &rectification of CERM Hammer assemblies b) Replacement &rectification of CERM Bearing assemblies c) Replacement &rectification of CERM Shaft Assemblies. d) Replacement &rectification of EERM Hammer assemblies e) Replacement &rectification of EERM Worm Gear Assemblies f) Replacement &rectification of EERM Shaft Assemblies. (Insulation along with cladding need to be removed &restored by Vendor with material supply if required). g) Replacement &rectification of EERM Bearing assemblies h) Replacement &rectification of Support Insulator i) Replacement &rectification of Torque Insulator j) Replacement &rectification of Antisway Insulator k) Replacement &rectification of Hopper heater. (Insulation need to be removed &restored by Vendor with material supply). l) Replacement &rectification of Hopper Vibrator. m) Gearbox overhauling of all 52 nos' of gearboxes. n) Asbestos Rope change of doors of ESP, insulator box. o) Alignment checking and rectification of ESP internal if required. p) Alignment/Air tightness checking and rectification of All ESP doors, insulator box doors (If required). [#No air ingress# need to be confirmed after box up of all doors at the time of AIRLOAD test (with both ID & fd running).} q) Painting of different areas.
GD Screen Replacement:
GD Screen Replacment GD screen (perforated screen 2&3) replacement of all 4 (four )inlet ducts need to be done. This includes all required fabrication job. (Material will be supplied by WBPDCL).
Painting:
Painting of different areas 1. ALL MOTOR ALONG WITH CANOPY FOR CERM, EERM & GDRM (52 Nos) 2. ALL GEAR BOX FOR CERM, EERM & GDRM (52 Nos) 3. ALL SHAFT & SUPPORT INSULATOR HOUSING (96 nos) 4. ALL INSPECTION DOORS (52 nos) 5. ALL ESP TRANSFORMERS (24 Nos) 6. RAILINGS OF ROOF (Total railing of ESP roof) 7. STAIRCASE OF ESP (Staircase of middle & other 2 sides of ESP) Consumables Materials like Paint/Red-oxide/Asbestos rope, Hylomer, Adhesive (dendrite, hole tight etc.), Petrol, Kerosene, Thinner, Gaskets for Support Insulator Housings & Dis-connecting Switch Box etc. under the scope of contractor.
GD test (optional):
GD TEST
TECHNO ENGINEERING (BID ID -6678489)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid