Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC Selected | |
| 2 | L2₹12.1 L+₹36,492 (3.11%)Rejected-AOC 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | L2 | Rejected-AOC Selected | |
| 3 | L3₹13.2 L+₹1.4 L (12.3%)Rejected-AOC N A | NA | NA | 121004 | L3 | Rejected-AOC Selected | |
| 4 | L4₹15.7 L+₹4.0 L (33.7%)Rejected-AOC K 4 50 GALI NO 27 WEST GHONDA DELHI 110053 DELHI 110033 | NORTH | DELHI | 110033 | L4 | Rejected-AOC Selected | |
| 5 | L5₹19.7 L+₹8.0 L (68.2%)Rejected-AOC | L5 | Rejected-AOC Selected |
Tender Value
₹16.5 L
EMD Value
₹32,955
Closing Date
22 Aug 2019, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
Routine Maintenance of EI , Fans, compound lights and Routine Maintenance , operation of drinking water supply pump set and Operation , comprehensive maintenance of Air Conditioner units/water coolers and miscellaneous electrical works
2019_PWD_178092_1
154 /EE (E)/PWD DHC and ND/Central /2019-20
Open Tender
Electrical Works
Works
365 days
New Delhi
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹32,955
19 Oct 2020
9 Aug 2019
22 Aug 2019
9 Aug 2019
22 Aug 2019
9 Aug 2019
Amount
SH- I (Routine Maintenance & Operation) Routine maintenance and attending day to day complaints of electrical installations and compound/security lights alongwith allied fixtures & feeder pillars etc. including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-Charge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor & keeping the entire installation on functional mode including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets in different location along with sluice / gate valves etc to fill up over head water tank for timely delivery of water supply and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation & keeping the entire installation on functional mode by deploying multi-tasking staff and Khallasi in general shift on all days of the month including Sunday & Holidays, as per terms & conditions attached and as per direction of Engineer-In-Charge etc as required
SH- II (Operation & comprehensive maintenance) Servicing of following capacity WTAC / STAC split type AC units including cleaning, washing from High pressure water spray electric machine, coil cleaning with van clean chemical and system dry from air blower, oiling, greasing including replacement of blower, motor, compressor, PCB, Plug top, 3 core copper conductor cable, remote and all types of defective parts , condenser coil, cooling coil, charging of refrigerant gas to make the already installed WT/Split type A.C. units fully functional and reinstallation of the same etc. complete as required. The firm is advised to visit the site, before quoting the rates. All the above units were functional last year, nothing extra shall be paid for above items for making the units fully functional, testing and commissioning etc as required alongwith credit for worn out accessories under buy back arrangement. (a) Window type AC / Split type AC units of 1.0 TR/1.5 TR / 2.0 TR capacity
b) Water coolers of capacity 100/150 Liters
Operation & comprehensive maintenance of Window/Split type AC units of 1.0/1.5/2.0/TR capacity of different makes including cleaning, washing from high pressure water spray electric machine, coil cleaning with van clean chemical and make system dry from air blower, oiling, greasing, replacement of defective blower, indoor/ outdoor motor, compressor, PCB, plug top, remote, starting/ running capacitor, starting relay, thermostat, propeller fan, condenser coil, cooling coil, 3 core copper conductor cable, charging of refrigerant gas, as per already installed Window/Split type AC unit complete with testing and commissioning etc. as required alongwith credit for old dismantle material (50- Nos.)
Operation & comprehensive running maintenance of 100/150 liters capacity different makes water cooler units including repairing/replacement of condenser motor, compressor & all type of defective parts, such as Gun metal taps, plug top, float valve assembly, condenser coil and cooling coil, charging of refrigerant gas in case of leakage excluding water cooler body and reinstallation of the same complete, as per terms & conditions attached alongwith credit for worn out accessories under buy back arrangement. (5 Nos.)
SH- III (Day to day maintenance work) Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 Sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel conduit including dismantling as required. a) Group C
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C
Supplying and drawing of following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel conduit as required. a) 3 x 1.5 Sq. Mm
b) 6 x 1.5 Sq. Mm
c) 3 x 6 sq. Mm
d) 3 x 4 Sq.mm
e) 6 x 4 Sq.mm
wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface /recessed steel conduit as reqd. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm eatth wire
b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
d) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required a) 8 Module (125 mmX125 mm)
b) 12 Module (200 mmX150 mm)
c) 6 Module (200 mmX75 mm)
d) 3 Module (100 mmX75 mm)
Supplying and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 Ampers switch
b) 15/16 Ampers switch
c) 6 pin 15/16Ampers socket outlet
Supplying & Fixing of GI Box alongwith modular base 6 module, cover plate, 2 no. 16Ampers modular switch & 2 nos 6 pin 15/16 amps socket in recessed etc as required.
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 ampers modular socket outlet and 15/16 ampers modular switch, connection etc as required.
Supplying, installation, testing & commissioning of energy efficient 1200 mm sweep size ceiling fan including wiring the down rod of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on fan box etc as required.
Supplying and fixing of steepped type electronic fan regulator on the existing modular switch box including connection but excluding modular plate etc. as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 Volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 Ampers, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. a) 4 way (4 + 12), Double door
b) 8 way (4 + 24), Double door
Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 14 way, Double door
Supplying and fixing of 5 ampers to 32 ampers rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required a) Single pole
Supplying and fixing of following rating, double pole, 240 Volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required a) 63 Ampers
Providing and fixing of following rating and breaking capacity MCCB in existing cubicle panel board/DB including drilling holes in cubicle panel/DB, making connections, etc. as required. a) 100A, 16 kA, breaking capacity TPMCCB with thermal megnatic release (ICU= 100% ICS)
b) 125 A, 16 kA, breaking capacity TPMCCB with thermal megnatic release (ICU= 100% ICS)
c) 250 A, 25 kA, breaking capacity TPMCCB with thermal megnatic release (ICU= 100% ICS)
d) 400 A, 35 kA, breaking capacity TPMCCB with thermal megnatic release (ICU= 100% ICS)
Supplying, installation testing commissioning of heavy duty exhaust fan of 300 mm sweep size, 900 rpm speed with shutter & louvers in the existing opening including making the hole to suit the size of the above fan, making good the damages, connection, testing & commissioning etc as required.
Supplying and laying of one number PVC insulated and Aluminum Conductor armored power cable of 1.1 KV grade of following size direct on surface /wall as required. a) 4 X 25 Sq.mm
b) 3.5 X 35 Sq.mm
c) 3.5 X 50 Sq.mm
Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 38W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size) suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with the help of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The Total system Lumen of 34W to 38W LED should be 3600 with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.95,CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison
Supplying, installation, testing & commissioning of 20W to 22W, 6000K (1200 mm) energy efficient LED wall mounted light luminaries, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver, suitable to work on 230 volts, AC supply complete with connection etc. with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required at site
Shaka Electrical (India)
Jasvinder Electric Works
Ele Mec Engineering Co.
SHASHANK ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .