| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC 3A SOURENDRA MOHAN GHOSH SARANI MANGOE LANE KOLKATA 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹1.4 L | L1 | Accepted-AOC L1 |
| 2 | L1₹14.9 LAccepted-AOC 1ST FLOOR OPP GURUDWARA GURUDWARA ROAD BENACHITY DURGAPUR 713213 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | 713213 | ₹14.9 L | L1 | Accepted-AOC L1 |
| 3 | L2₹21.5 LRejected-Finance | ₹21.5 L | L2 | Rejected-Finance Higher than the lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not Satisfactory |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Satisfactory |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
5 Oct 2021, 3:00 pmClosed
EXECUTIVE ENGINEER, BALURGHAT DIVISION, PHE DTE
OFFICE OF THE EXECUTIVE ENGINEER, BALURGHAT DIVISION, PHED, RAGHUNATHPUR PHE COMPLEX, P.O. - BELTALAPARK, P.S. - BALURGHAT, DIST. - DAKSHIN DINAJPUR, PIN - 733103
Supply of required Chemical Equipments Laboratory glassware reagents standard reference materials traceable to NIST measuring instruments and calibration of measuring instruments as per ISO 17025 2017 Protoco In Connection with NABL accreditation
2021_PHED_344349_1
WBPHED/EE/BD/NIeQ _3 of 2021-2022
Open Tender
Laboratory and scientific equipment
Item Rate
20 days
BALURGHAT BLOCK, DAKSHIN DINAJPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹40,000
Yes
25 Jun 2025
17 Sept 2021
7 Oct 2021
17 Sept 2021
5 Oct 2021
17 Sept 2021
pH Buffer - 25°C : Clear, Colourless pH Buffer Solutions. Tested at 25°C and certified by Reagecon's ISO 17025 accredited test method. NIST traceable, pH: 2.00 ±0.01@25°C in 500 ml
pH Buffer - 25°C : Clear, Colourless pH Buffer Solutions. Tested at 25°C and certified by Reagecon's ISO 17025 accredited test method. NIST traceable, pH: 4.00 ±0.01@25°C in 500 ml
pH Buffer - 25°C : Clear, Colourless pH Buffer Solutions. Tested at 25°C and certified by Reagecon's ISO 17025 accredited test method. NIST traceable, pH: 7.00 ±0.01@25°C in 500 ml
pH Buffers - 25°C : Clear, Colourless pH Buffer Solutions. Tested at 25°C and certified by Reagecon's ISO 17025 accredited test method. NIST traceable, pH: 10.00 ±0.01@25°C in 500 ml
Filter Paper No: 542, 12.5 cm, whatmam
Hydrochloric Acid min 36.5%, Analytical Grade, set of 6000 ml.
Turbidity meter with standard calibration sollution and accessories measuaring cuvette carrying case and as per specification givern in notice & direction of EIC.Range - 0.01 to 1100 NTU (auto running) resolution 0.01 - 9.99 NTU = 0.01NTU/10.0 - 99..9 NTU = 0.1 NTU/100-1100 NTU=1 NTU. Calibartion 4 points auto calibartion unit shall be supplied with required calibaration sollution operating manual and as per specification in notice and direction of EIC..(Make - lovibond thermo - utech , amke approved by EIC)
Glass Rod
Glass Dropper
Iso propyl Alcohol Analytical quality, 500 ml
EDTA disodium salt, analytical grade, 100 gm
Calcium carbonate volumetric standard. secondary reference matenal for complexometry, traceable to NIST Standard Reference Material (SRM) CertiPUR® for Total Hardness as CaC03 . 1.02410.0050 merck
Ammonia Buffer solution for total hardness, 500 ml
Eriochrome Black-T, 25 gm
Ammonia Solution 25% Analytical quality set of 2000 ml
Triethanolamine min: 99.5% for Total Hardness, 500 ml
Ammonium Chloride Analytical grade, 500 gm
Magnesium Sulfate Analytical quality, 500 gm
Conductivity Standard- 25˚C, certified by ISO 17025 Accredited test Method. NIST traceable 1413us/cml at 25˚C in 500 ml bottle
Burette, Class A, certified as per ISO 17025 requirement set of 4, Cap: 50 ml, Glass
Pipette Graduated Mohr type, Class A, certified as per ISO 17025 requirement set of 6, Cap: 1 ml/0.01 div
Pipette Graduated Mohr type, Class A, certified as per ISO 17025 requirement set of 6, Cap: 5 ml/0.05 Div
Pipette Graduated Mohr type, Class A, certified as per ISO 17025 requirement set of 6, Cap: 10 ml/0.1 Div
Pipette Graduated Mohr type, Class A, certified as per ISO 17025 requirement set of 4, Cap: 25 ml/0.2 Div
Volumetric Flask Class A, certified as per ISO 17025 requirement set of 6, cap: 10 ml
Volumetric Flask Class A, certified as per ISO 17025 requirement set of 4, Cap: 50 ml
Volumetric Flask Class A, certified as per ISO 17025 requirement set of 6, Cap:100 ml
Volumetric Flask Class A, certified as per ISO 17025 requirement set of 2, Cap: 250 ml
Volumetric Flask Class A, certified as per ISO 17025 requirement set of 2, Cap: 500 ml
Volumetric Flask Class A, certified as per ISO 17025 requirement set of 2, Cap: 1000 ml
Measuring Cylinder Class A,certified as per ISO 17025 requirement 25 ml
Measuring Cylinder Class A,certified as per ISO 17025 requirement 100 ml
Supply & demonstration of Hot Air Oven : Outer body made of Mild Steel Sheet duly powder coated and inner chamber made of Stainless Steel Sheet (304 Grade) and adjustable Stainless Steel Wire Mesh shelves. Space between inner chamber and outer wall is filled with high grade mineral wool for minimal heat loss. The Double Walled Door should have synthetic rubber / fibre gasket. Unit should have ventilation slides on two sides to control inner air/ vapor circulation. Fitted with beaded heating elements placed in ribs, at bottom and sides for uniform heat distribution. To work on 220/230 volts AC supply. Unit should be fitted with Digital Temperature Indicator-cum- Controller for temperature control from +5º C above ambient to 250ºC Fitted with Air Circulating Fan. Working chamber Size: 16”x16”x16”
Supply of installation & demonstration of basic salinity conductivity TDS Meter Cond 7110/star-212 with cell tetracon 325 Duraprobe 4 electrode conductivity cell & as per specification in notice & direction of E.I.C MAKE: Thermo_ Orion/WTW/make approved by the EIC
Supply of Analytical Balance, 210 gm capacity, 0.1 mg redability, with internal calibration facility, Air-shield, SS pan, Spirit level indicator. Shimadzu Make
Procurement of Certified (as per ISO-17025 requiremet) RF wireless thermometer-hygrometer-clock.
Procurement of certified specific gravity Hydrometer
Supply & installation Barometer (pressure 740 to 800 mm Hg) & Room Thermometer 0 to 50 deg C with calibration certificate as per ISO-17025 requirement
Supply, Delivery & Installation of Sample storage Refrigerated Chamber, double door
Supply of installation of a double stage with quartz boiler, quartz condenser & built in quartz heater vartical panel mounted, with auto low water level cut off device with audio alarm system, approximate output capacity 2.5 lt/hr water distillation plant is suitable for spectrophotometric analysis
Supply of online Safety Shower & eye-wash, specification as per IS 10592:1982, SS stay open ball valve with yellow ABS push plate & activation for shower - Pull rod & for eyewash – Push plate
Laboratory Apron Set of 6, assorted size
Laboratory Clog front cover shoe 2/pair
Nitrile gloves , pk of 50/100 nos
Qrtz Cell 10mm for Spectrophometer , set of 2
Qrtz Cell 50mm for Spectrophometer , set of 2
Supply of 23rd Edition_ Water & Waste water Analysis published by American Public Health Association(APHA)
Aspirator Bottle set of 2, cap:5lit
Waste Bin with cover 50 lit.
Almirah
Printer
Surgical Mask pack of 100
Touchless Hand free wall mounted Sanitizer
Supply of publication of BIS for IS 3025: Part 11, Part 16, Part 10, Part 21, Part 23, Part 53, Part 37, Part 26
Hand Wash
Oven gloves (Cotton) pair
Table/Slab includinganti - vibration platform for digital balance
Pipette sucker
Foot operated Hand Sanitizer equipment
Sodium Hydroxide, Analytical grade, 500 gm.
Sodium Chloride for preparation of 2000 mg/L Solution
Sulphuric Acid, 2000 ml
Phenolphthanelein indicator
Methyl red
Bromocresol green
2 Propanol
Hydroxylamine Hydrochloride 100gm/pack
.45um cellulose membrane filter 22 or 45 mm diameter
0.2 um cellulose membrane filter 22 or 45 mm diameter
0.22 um cellulose membrane filter 22 or 45 mm diameter
Type I Reagent water ( Organic free)
Wide mouthed glass stoppered bottle,1000ml
Nessler's Tubes glassware 50ml
Beaker PP SET of 12 cap; 50 ml
Beaker 100 ml Borosilicate Glass
Beaker 250 ml Borosilicate Glass
Conical Flask 250ml ,Borosilicate Glass
Router
Sodium Carbonate , SRM , NIST TRACEABLE
Murexide Indicator,5gm/pack
Thermometer 1-100 ◦C
Safety Googles,pk of 2 NOS.
Acid alkali proof gloves,pk of 2 pairs
Particulate restirator with exhalation valve- mask,pk of 10
Anti vibration pad
p H Meter Range 1-16, Each no.
Platinum - Cobalt Standard solution,500CU (Potasium chloro platinate(K2PtCl6)& Cobaltous Chloride (CoCL2.6 H2O),100gm
Hydrochloric Acid 37% , 500ml
Potassiun ferocyanide cristal , 500gm
Magnesium sulphates , 500gm
Calcium carbonate volumatric Standard secondary reference matenal for complexometry , traceable to NIST Standard Reference material (SRM) Certipur for total hardness as CaCo3 (Each pack)
Sodium chloride volumetric standard, secondary reference material for argentometry, traceable to NIST standard reference material.
Potassium Chromate, each pack
Silver nitrate analitical grade , 25gm
Burette, class B, certified as per ISO 17025 requirement set of 4, Cap: 50 ml, Glass
Pipette Graduated Mohr type, class Acertified as per ISO 17025 requirement set of 6, cap : 1 ml
Pipette Graduated Mohr type, class Acertified as per ISO 17025 requirement set of 4, cap : 2 ml
Volumetric Flask Class A, certified as per ISO 17025 requirement set 6, Cap : 5 ml
Measuring Cylinder Class A, certified as per ISO 17025 requirement 250 ml
Measuring Cylinder Class A, certified as per ISO 17025 requirement 50 ml
Measuring Cylinder Class A, certified as per ISO 17025 requirement 10 ml
Taste and odour free distilled water
Dessicator ,8 inch
Pyrometer for Hot Air Over
BHARATI CHEMICAL AND SCIENTIFIC WORKS
DULAL MAJUMDAR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .