| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoted. | |
| 2 | L2₹22.2 L+₹13,898 (0.63%)Rejected-AOC | L2 | Rejected-AOC Not accepted since higher rate quoted. | |
| 3 | L3₹24.2 L+₹2.1 L (9.56%)Rejected-AOC | L3 | Rejected-AOC Not accepted since higher rate quoted. | |
| 4 | L4₹24.2 L+₹2.1 L (9.64%)Rejected-AOC | L4 | Rejected-AOC Not accepted since higher rate quoted. |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
9 Jun 2022, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR TO CLEANING OF SEWAGE LINE AND OVER HEAD WATER TANKS AT MIL STN GANDHINAGAR
2022_MES_524294_1
GE(A)/GNR/TOKEN/14 of 2022-23
Open Tender
Civil Works
Item Rate
270 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹44,000
Yes
6 Aug 2022
16 May 2022
11 Jun 2022
16 May 2022
9 Jun 2022
23 May 2022
16 May 2022 - 22 May 2022
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc. 15cm thickness (below or above ground level) all as specified and directed.
Demolition of reinforced cement concrete of manhole covers etc complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exc 3m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm with excavated soil complete all as specified and directed.
Removing excavated material soils, not exc 50m and depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.
M&L for cement concrete (1:2:4), type B-1, using 20mm graded stone aggregate in window cills, lintel band, bed block, copings and the like including weathering, slightly rounded or chamfered angles and throating, Including necessary form work complete all as specified and directed.
M&L pre-cast reinforced cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in manhole covers including placing the cover in position and set in cement mortar (1:6) complete all as specified and directed. Note: Reinforcement shall be measured and paid seperately.
M&L for Brick work with sub class old 'B' bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises,
Rendering 12mm thick on fair faces of brick work in CM 1:4 finished even and smooth using extra cement
Rendering 12mm thick plaster on fair faces of brick work in CM 1:4 finished even and smooth without using extra cement.
De-silting/De-sludging the manholes/septic tanks upto 1.5m deep, ditch a trench in any distance upto 250 mtr stack the sludge in trenches and covered with soil to avoid nusance all as directed by Engineer -in- charge.
De-silting/De-sludging the manholes/septic tanks exc 1.5m deep and not exceeding 3.00 m, ditch a trench in any distance upto 250 mtr stack the sludge in trenches and covered with soil to avoid nusance all as directed by Engineer -in- charge.
De-silting/De-sludging the manholes/septic tanks depth exceeding 3.0m and n.exc 4.5m, ditch a trench in any distance upto 250 mtr stack the sludge in trenches and covered with soil to avoid nusance all as directed by Engineer -in- charge.
De-silting/De-sludging of sump at sewage pumping station depth n.exc 15m with required rope, bucket, ladder and scaffolding etc. and getting out, ditch a trench in any distance upto 250 mtr stack the sludge in trenches and covered with soil to avoid nusance all as directed by Engineer -in- charge.
Removal of blockage/chock up obstructing the flow in sewage line by rodding with rods/wooden kempti/chock remover and making the continuous flow between two manholes for 100mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured.
Removal of blockage/chock up obstructing the flow in sewage line by rodding with rods/wooden kempti/chock remover and making the continuous flow between two manholes for 150mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured.
Removal of blockage/chock up obstructing the flow in sewage line by rodding with rods/wooden kempti/chock remover and making the continuous flow between two manholes for 200mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured.
Removal of blockage/chock up obstructing the flow in sewage line by rodding with rods/wooden kempti/chock remover and making the continuous flow between two manholes for 300mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured.
M&L, in repair, salt glazed stoneware gully traps square or round mounthed, type 'P' of size 125 x 100mm, setting and jointing with cement mortar (1:1) complete all as specified and directed.
M&L for cutting into existing manholes for connection new drain making good to pipes and rendering cutting out existing benching for and forming brackets channel (1/2 round orr 3/4 section) in cement concrete (1:2:4) type B-1 and reforming benching as required for 150 mm bore pipe complete all as specified and directed
Cleaning of WC/EWC and removal of blockage by pumping of waste all as directed by Engineer-in-Charge
Cleaning of nahani trape 75 mm dia and removal of blockage all as directed by Engineer-in-Charge
Cleaning of gully trap of size 125/110 mm and removal of blockage all as directed by Engineer-in-charge
S&F, in repair, HDPE water storage tank lid black (with arrangement for locking for 500/1000 litres capacity tank complete all as specified and directed.
S&F, in repair, HDPE water storage tank lid black (with arrangement for locking for 5000 litres capacity tank complete all as specified and directed.
Taking up or down steel tubing and connections for 15mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 20mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 25mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 15mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 20mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 25mm bore of pipe complete all as specified and directed.
Disconnecting, setting aside (or lowering if required) and Cleaning & removing all scale and dirt etc from HDPE water tanks of 500 litres capacity (Tanks placed on top of roof) and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including complete, all as specified and directed.
Disconnecting, setting aside (or lowering if required) and Cleaning & removing all scale and dirt etc from HDPE water tanks of 1000 litres capacity (Tanks placed on top of roof) and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including writing the date of cleaning o complete, all as specified and directed.
Disconnecting, setting aside (or lowering if required) and Cleaning & removing all scale and dirt etc from HDPE water tanks of 5000 litres capacity (Tanks placed on top of roof/staging) and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position complete, all as specified and directed.
Supplying , fixing & Hoisting and fixing in position and connecting, in repairs, 500 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed.
Supplying , fixing & Hoisting and fixing in position and connecting, in repairs, 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed.
Supplying , fixing & Hoisting and fixing in position and connecting, in repairs, 5000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed.
S&F, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -210 Gms)
S&F, in repair, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -210 Gms)
S&F, in repair, 25mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -455 Gms)
S&F 25mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -455 Gms)
Dismantling of cast iron, PVC or reinforced concrete drain pipes jointed in cement mortar for 110mm and 75mm bore of pipe from wall/floors etc complete all as specified and directed.
S&F, 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including stack clamp complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including stack clamp complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or floor complete all as specified and directed.
S&F, 75mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed.
S&F, 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed.
S&F, in repair, PVC (SWR) floor trap, with chromium plated grating including jointing with solvent cement, dia of outlet 75mm complete all as specified and directed.
Demoliton and breaking up drain pipes (SGSW),AC or reinforced concrete set in CM of dia 100mm.
Demoliton and breaking up drain pipes (SGSW),AC or reinforced concrete set in CM of dia 150mm.
Demoliton and breaking up drain pipes (SGSW),AC or reinforced concrete set in CM of dia 200mm.
Demoliton and breaking up drain pipes (SGSW),AC or reinforced concrete set in CM of dia 300mm.
M&L for salt glazed stoneware drain pipes, 100mm internal diameter, grade 'A' laid in trenches and jointed complete all as specified and directed.
M&L for salt glazed stoneware drain pipes, 150mm internal diameter, grade 'A' laid in trenches and jointed complete all as specified and directed.
M&L for salt glazed stoneware drain pipes, 200mm internal diameter, grade 'A' laid in trenches and jointed complete all as specified and directed.
M&L for 300mm bore, reinforced concrete pipes, class NP-2, laid and jointed complete with collars all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in bed to drain pipes including packing under and hunching against the sides of pipe after they are laid and tested for 100mm bore of pipe complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in bed to drain pipes including packing under and hunching against the sides of pipe after they are laid and tested for 150mm bore of pipe complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in bed to drain pipes including packing under and hunching against the sides of pipe after they are laid and tested for 200mm bore of pipe complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in bed to drain pipes including packing under and hunching against the sides of pipe after they are laid and tested for 300mm bore of pipe complete all as specified and directed.
S&F in repair vitreous China squatting pan 'Orissa pattern' size 580x440 mm, white with integral foot rest including 'P' or 'S' trap front or back inlet excluding flushing cistern and flush pipe including connection to trap and flushing pipe etc and making good to floor complete all as specified and directed.
Shreeganesh Construction
Shree Builders
nirman construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .