Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 CrAccepted-AOC | ₹11.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹11.4 CrRejected-AOC | ₹11.4 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹11.6 CrRejected-AOC | ₹11.6 Cr | L3 | Rejected-AOC L3 |
| 4 | L4₹12.7 CrRejected-AOC PLOT NO HIG 7 CHUNVATI LANE GOPALGAN BALASORE 756001 | BALESHWAR | ODISHA | 756001 | ₹12.7 Cr | L4 | Rejected-AOC L4 |
| 5 | L5₹15.0 CrRejected-AOC | ₹15.0 Cr | L5 | Rejected-AOC L5 |
Tender Value
₹14.0 Cr
EMD Value
₹28.0 L
Closing Date
27 Jul 2020, 3:00 pmClosed
CCE R AND D EAST KOLKATA
NAPIER ROAD HASTINGS KOLKATA 700022
PROVISION OF TECHNICAL CUM ADMINISTRATIVE BUILDING AND MISCELLANEOUS WORKS FOR THE CENTRE FOR CMSDS AT KOLKATA
2020_DRDO_562250_1
CCE R AND D EAST/ENQ-01/CIV/KOL/2020-21
Limited
Civil Works
540 days
KOLKATA
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
CCE R AND D EAST
₹28.0 L
Yes
4 Mar 2021
15 Jun 2020
28 Jul 2020
16 Jun 2020
27 Jul 2020
7 Jul 2020
19 Jun 2020 - 24 Jun 2020
Amount
SUBHEAD - I : EARTH WORK :
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (a) All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (a) All kinds of soil.
Extra for every Additional Lift of 1.5 m or part there of in excavation / banking excavated or stacked materials.
a) All kinds of soil
Filling Available Excavated Earth (Excluding Rock) in trenches,Plinth sides of foundatios etc,in layers not exceeding 20cm in depth consolidating each diposited layer by ramming and watering,lead upto 50meter and lead upto 1.5meter
Supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Supplying and filling in plinth with river sand under floors, including watering,ramming, consolidating and dressing complete.
SUB HEAD - II : ANTI TERMITE TREATMENT WORK:
Supplying chemical emulsion in sealed containers including delivery as specified. (a) Chlorpyriphos/ Lindane emulsifiable concentrate of 20%.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: (i) With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (a) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: (i) With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
SUB HEAD - III : PLAIN AND REINFORCED CEMENT CONCRETE WORK:
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : a) 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).Note: Truck Mounted rotary/TMR/Tubewell boring machine shall not be used .
a) 450 mm dia piles
Providing and laying in position Machine Batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
a) All works upto plinth level.
b) All works above plinth level upto floor V level.
c) Extra for Deduction of not pumping of concrete to site of laying.
Providing and laying in position Ready Mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately)
a) All works upto plinth level.
b) All works above plinth level upto floor V level.
c) Add / Deduct for using extra cement in the items of design mix over and above the specified cement content therein.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all level.
a)Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) including Providing & applying a coat of DAMP PROOF membrane approved on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification ( per 50 kg cement).
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundations, footings, bases of columns etc. for mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform.
c) Lintels, beams, plinth beams, girders, bressumers and cantilevers
d) Columns, Pillars, Piers, Abutments, Posts and Struts.
e) Stairs, (excluding landings) except spiral-staircases
f) Weather shade, Chajjas, corbels etc., including edges.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured). (a) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints. (a) 300 mm wide.
Supplying and applying of 1 mm thick Hypalon membrane system Expoband One membrane for sealing expansion joints using high strength epoxy adhesive NITOBOND PC 40.The membrane should have a tensile strength of 7Mpa and elongation of 300%.
SUB HEAD - IV : BRICK WORK:
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : (a) Cement mortar 1:6 (1 cement : 6 coarse sand.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (a) Cement mortar 1:6 (1 cement : 6 coarse sand).
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement : 4 coarse sand) including Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (a) Cement mortar 1:4 (1 cement : 4 coarse sand).
SUB HEAD - V : FINISHING :
Providing of 6mm cement plaster of mix in all surface with (a) cement mortar 1:3 (1 cement : 3 fine sand) at all levels.
Providing of 12 mm cement plaster of mix in all surface with (a) cement mortar 1:6 (1 cement : 6 fine sand) at all levels.
Providing of 15 mm cement plaster on the rough side of single or half brick / C.C wall of mix: (a) 1:6 (1 cement : 6 fine sand) at all levels.
Providing of 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer.
Finishing walls with water proofing cement paint of required shade : (a) New work (Two or more coats applied @ 3.84 kg/10 sqm.
Finishing walls with Acrylic Smooth exterior paint of required shade : Providing and applying two coats of Anticarbonation, high performance aliphatic acrylate based UV- resistant , breathable protective and decorative coating for concrete and masonry DEKGUARD S comprising of a single component, penetrating silane/siloxane primer and a single component aliphatic acrylate, solvent based top coat,providing resistance to aggressive agents, UV rays and rain at a total dry film thickness of 150 microns.The Adhesive approved by the British Board of Agreement under Certifi cate No. 92/2824. bond strength with concrete must be : > 2.5N/mm2.It must have Tensile strength(ASTM D638) > 2.5 N/mm2 and Elongation (ASTM D638) > 4%
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : (a) Two or more coats on new work.
Varnishing with varnish of approved brand and manufacture : (a) Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish. Including with French spirit polishing : (b) Two or more coats on new works including a coat of wood filler.
Providing & fixing chicken wire mesh at the junctions of RCC and C.C , 200mm overlapping on both sides with all necessary hardware etc., complete with guage and mesh size - 20swg and 20mm mesh
White Washing with lime on new walls and ceiling three coats to give an even shade including preparation of surface etc.,complete as directed.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
SUB HEAD - VI : FLOORING WORK:
52 mm thick cement concrete flooring with concrete hardener topping,under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but including the cost of nosing of steps etc. complete with Extra for making chequers of approved pattern on cement concrete floors,steps, landing, pavements etc..
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Polished Granite stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Made of NITCO Company :Model name -Bermuda or Made of Somany ompany :Model name Celestial /Elegance series or Made of Kajaria company :Model name Super Glossy Nanotech K-6016/6018/6019/6101/6012 & Jhonson Make : Quarzet DK & Quarzet HL Or Equivalent
a) Size of Tile 600x600 mm.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including routing the joint with white cement & matching pigments etc.Made of NITCO Company :Model name -Bermuda or Made of Somany ompany :Model name Celestial /Elegance series or Made of Kajaria company :Model name Super Glossy Nanotech K-6016/6018/6019/6101/6012 , Jhonson Make : Quarzet DK & Quarzet HL Or Equivalent. a) Size of Tile 600x600 mm.
Providing and laying rectified Glazed Non skid Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Make of NITCO Company : Model name Exotica/Maxima series or ,Made of Somany Company : Model name Trecker/Sprinkler series or , Made of Kajaria Company : Model Name GaniliaCrema /Beige/Almono Made of Johnson /Equivalent
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete..Make of NITCO Company : Model name Exotica/Maxima series or ,Made of Somany Company : Model name Trecker/Sprinkler series or , Made of Kajaria Company : Model Name GaniliaCrema /Beige/Almono Made of Johnson /Equivalent
a)Size 300x600
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Makes : Johanson , sandex Series or equivalent
a) Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-Charge. a) Granite work.
Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels. (a) Granite of any colour and shade. (i) Area of slab over 0.50 sqm.
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab,including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand) :Makes : Johanson , sandex Series or equivalent a)25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. Makes : Johanson , sandex Series or equivalent
Providing and laying machine cut, mirror polished, Italian Marble stone laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Makes : Johanson , sandex Series or equivalent
a) 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
Providing and fixing Decorative pressed cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
a)Light shade pigment using white cement
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge
Providing and Applying of Anti-Static SL floor topping on granolithic flooring for effective passage to the earth having resistance of the static conductive topping in the range of 5x10E4 -1x10E6 ohm and that of static dissipative topping in the range of 1x10E6-1x10E9 ohm. The static conductive topping shall take a time 0.01 seconds to decay a charge to 0% of its peak value at :t 5 kv.It should have minimum compressive strength of 50 N/mm2 a minimum tensile strength of 16 N/mm2 and a minimum flexural strength of 34N/mm2 when tested as per BS.6319.The system shall be preceeded by application of an epoxy based primer and overlaid with a conductive/Dissipative undercoat.The surface resistance of the conductive undercoat shall be in the range of 3x10E3-9x10E3 ohm, and the Dissipative under coat shall be in the range of 3x10E48-x10E4 ohm by using Sika/FOSROC chemical or equivalent & all as per direction of Engineer-in-charge.
SUB HEAD - VII : WOOD WORK / ALUMINIUM WORK :
Providing and fixing of IInd class teak wooden frames of size 100 x 150mm conforming,manufactured from commercial , including jamb, lock jamb, bead with M.S hold fast & finished with varnished of the surface as directed by Engineer-in-charge:
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 38 mm thick including ISI marked Stainless Steel butt hinges with necessary screws including Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters.
Extra for Not Providing and fixing ISI marked, IS : 1341, M.S. heavy weight butt hinges with necessary screws etc. complete : (a) 125x90x4.00 mm.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : a) For fixed portion. i) Powder coated aluminium (minimum thickness of powder coating 50 micron):
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) a) Powder coated aluminium (minimum thickness of powder coating 50 micron).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
a) With float glass panes of 5.50 mm thickness.
Providing and fixing 12 mm thick toughened glass of approved brand and manufacture, fixing arrangement and making necessary holes etc. for fixing , all complete as per direction of Engineer-in-charge
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (a) Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete : a) 300x16 mm.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : a) 150x10 mm.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : a) 125 mm.
Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. a) Twin rubber stopper.
Providing and fixing of rubber nylon door buffer (dia of 40mm and 50mm long) on wall with rowl plug and screw.
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. comp
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it water tight.
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified.
The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories
1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331- 09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME- 330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
SUB HEAD - VIII : STEEL WORK:
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
a) Hot finished welded type tubes
b) Hot finished welded type tubes for 50 Ø (Purlins)
Supplying and fixing of precoated Zincalume / Galvalume sheet roofing of 0.5mm TCT -AZ-150, 550 mpa (Alumunium Zinc Alloy coating of 150 gms, per sqm total on both sides) as per AS: 1397 in cover width of 1000-1020 mm, (size, shape and pitch of corrugation as approved by Engineer-in-charge).The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness (BMT), Hi-strength steel with min. 550 MPa yield strength. The steel sheet shall be fastened with 25 μm zinc-tin alloy coated, Hex head, self-drilling screw as per AS 3566-2002 Class 3 fasteners of approved make with EPDM washer as per the requirement considering the profile shape and design load. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12meter or as directed by Engineer-in-charge.(Make : Tata or Equivalent)
a) 0.63 mm thick with zinc coating not less than 275 gm/m2
Providing and fixing 15 cm wide, 45 cm overall semi- circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.
a) 0.63 mm thick with zinc coating not less than 275 gm/m2
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover with Grill of required thickness.for rolling shutters. a) 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Providing and fixing stainless steel ( Grade 317) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
SUB HEAD - IX : ROOFING & WATER PROOFING:
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm).
Waterproofing System: Providing two coats of liquid applied, solvent-free elastomeric waterproofing membrane, shall be made of hydrocarbon free pure polyurethane NITOPROOF 600 PF with at least 90% solid content after necessary surface preparation. The membrane when cured shall be capable of an extension of not less than 600%. Its tensile strength shall exceed 1.9 N/mm2 and the water vapour transmissions shall be less than 1g/m2/24 hour. The tear resistance should not be less than 21 KN/m as per ASTM D624-00 and should have a minimum shore hardness A value of 65. The Product Should have the Following Properties: Adhesion-in-peel test (N) (ASTM C836) : >60N Recovery from 350% elongation (%)(ASTM D412-90): 95 Water vapour transmission : 2.3mm film (g/m2/hr):0.6 Water permeability (DIN 1048): 0 Chemical resistance: Unaffected by mild acids, alkalis and water borne salts. Does not biodegrade It is to be protected with protective plaster/screed concrete admixed with integral waterproofing admixture CONPLAST WL@ 125 ml/bag of cement.(Contractor's scope)
Providing and fixing on wall face unplasticised Rigid Single socketed PVC rain water pipes conforming to IS : 13592 Type A, along with injection moulded fittings as required e.g., bends on any angle, sockets, junction, cowls, offsets, access pieces, including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, providing and fixing MS stays & clamps and cutting & making good the holes in floors and walls wherever required etc. all complete. (For Rain water pipe).
(a) 110 mm diameter.
SUB HEAD - X : FALSE CEILING WORK & VERTICAL BLINDS :
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.
wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint , all as per manufacturer's specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a)12.5 mm thick tapered edge gypsum moisture resistant board. (Make : Gproc , L Strong , Armstrong)
Providing & fixing levelor 10mm vertical blinds having top rall 39mm x 34mm high with wall thickness of 1.2mm having 25mm decorative insert. Control unit shall be of Derlin Plastic runner shall be moulded from Derlin Plastic with antifriction head rail and the top end of the louvers shall not exceed 0.5cm. The louver fabric shall be polyster viscose/polyster yarn dyed in fast colour with or without protective coating on lourvers with chemical for stain resistance & soil repetancy and shall have GI weight and steel / polymer ball chain for spacing. The top rall should be fixed on bracket of 14 SWG galvanized spring steel fixed firmly on walls by nylon plug and screw as per approve design and direction of the Engineer in Charge.
SUB HEAD - XI : SANITARY INSTALLATIONS WORK :
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :Size : 71 x36 x 81 cm (Cat no:- 20101 (s-22)) (a) W.C. pan with ISI marked white solid plastic seat and lid. (Make : Hindware,Jaquar or equivalent)
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:(Make : Hindware,Jaquar or equivalent)(Cat no:- 20042).
a)White Vitreous china Orissa pattern W.C. pan of size 58 X 44 cm with integral type foot rests
Providing and fixing white vitreous china flat back smalll urinal of size 26.5 X 31.5 X 44 CM with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the walls and floors wherever required : (a) Single half stall urinal P.V.C. manual flushing cistern (Make : Hindware,Jaquar or equivalent). (Hindware cat.no :-60001)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (a) White Vitreous China Table Top Basin (Make : Hindware,Jaquar or equivalent) (Hindware Cat. No. -10001)
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in- charge.(Make : Hindware,Jaquar or equivalent) (Hindware Cat. No. -F850015)
Providing and fixing Stainless steel connection for flush pipe of Grade 304 stainless steel connecting with wash basin, W.C. pan.(Make-Alton ALT2005,Havells or equivalent)
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required : (a) Kitchen sink with drain board.(Make -Nirali Elegance or equivalent) (i) 510x1040 mm bowl depth 250 mm.
Providing and fixing of 32 mm full thread waste coupling (chorme) as per the direction of Engineer-in- charge. (Make - Hindware or equivalent)
Providing and fixing 600 x 300 mm beveled edge Mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete as per the direction of Engineer-in- charge.(Make : Saint Gobain ,Cera or equivalent) model-5567
Providing and fixing toilet paper holder : (a) C.P. brass.(Make : Hindware,Jaquar or equivalent) (Hindware Cat. No. -F880003)
Providing and fixing liquid soap container of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (Make : Jaquar or equivalent)
Providing and fixing PTMT liquid soap dish (brass) 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 205gms. (Make : Jaquar or equivalent)(Hindware Cat. No. F880011)
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (a) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.(Make : Hindware,Jaquar or equivalent) (Hindware Cat. No. F880005)
Providing and fixing C.P. brass bib cock with wall flange of approved quality conforming to IS:8931 : (a) 15 mm nominal bore (Make : Jaquar or equivalent) (Model No, - CON-CHR-047KN)
Providing and fixing C.P. brass Angular stop cock (concealed) of standard design and of approved make conforming to IS:8931 as per the direction of Engineer-in- charge.(Model No, - CON-CHR-059KN) (a)15 mm nominal bore.(Make : Jaquar or equivalent)
Providing and fixing Flush cock with wall flange 25mm with plain knob as per the direction of Engineer-in- charge. (Make - Jaguar, Hindware or equivalent)(Model No, - CON-CHR-1081KN)
Providing and Fixing Health Faucet HINDWARE Cat.No-F160068 or JAQUAR Cat. No. 573 (ALLIED SERIES) or equivalent make KINGSTON-AGR ACS 49/KOHLER Cat. No. 12925IN-CP (HEALTH FAUCET W/WHITE SDSPRAY, M HOSE) with flexible pipe and wall hook with each European W.C. Pan.
Providing and fixing Nahani Trap of size 110 X 75mm. (Make : Birla Aerocon or equivalent)
Providing and fixing S.S. hinged grating, made up of stainless steel of size 5" X 5" plain jali (chorme finished) including setting in floor with cement mortar 1:3 as per the direction of Engineer-in- charge. (Make : Estylobath,Klaxon or equivalent)
Providing and fixing single flow Rain Showers Over Head of size 85 mm (3.5") Dia with Single Flow and Arm.model:Cera F7020102 or Hindware cat no:F160025 (Make :Hindware,Cera or equivalent) (Hindware : cat no-F160025)
SUBHEAD - XII : SOIL WASTE AND VENT PIPE AND FITTINGS WORK:
Providing and fixing SWR uPVC pipes (Type-B) confirming to IS 13592 : 1992 complete with all fittings e.g. plain or door bends, junctions, cowls, offsets, access pieces etc. jointing with rubber rings and solvent cement including fixing the pipes on wall face with MS galvanized holder bat clamps or suspended below ceiling with MS galvanized hangers/supports and fasteners all as approved by the engineer in charge including Cutting holes in walls, floors excavation, refilling and disposal of surplus earth wherever required and making good . (a) 110 mm dia.
Providing and fixing uPVC deep seal 'P' or 'S' of self cleansing design with or without vent arm with provision for connecting uPVC inlet fitting complete including cost of cutting and making good the walls and floors wherever required. (a) For 110mm inlet and 80mm outlet.
Providing and fixing uPVC threaded waste pipes (I.S:4985-2000) Class - 6 including all fittings e.g bends, junctions, elbows, tees, offsets etc. jointing with screwed joints including cutting holes in walls, floors excavation, refilling and disposal of surplus earth wherever required and making good.
(a) 32 mm nominal bore.
(b) 50 mm nominal bore.
(c) 80 mm nominal bore.
SUBHEAD - XIII : WATER SUPPLY SYSTEM:
Drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through all kinds of soil and rocks with combination drilling rig or any other method as required to suit the site condition as per direction of Engineer in charge. The job includes supply of equipment,T&P,consumable ,necessary for boring and casing pipes,lowering the PVC,grade 'B' pipe,screen pipe in position,clearing of site including washing the bore etc.
a) For lowering with 150mm dia (Nominal) pipe
i) From 0 to 50 Metre
b) For lowering with 100mm dia (Nominal) pipe
i) From 51 to 250 Metre
Supplying and lowering following size of PVC housing pipe with or without slotted pipes as per necessity upto 20 Metre lengtht fitted and fixed in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying & fixing of all jointing ,materials T & P etc. and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign material.
a) 150mm dia PVC casing pipe (class 'B') confirming to standard specifications (schedule -80)
i) From 0 Metre to 50 Metre
100mm dia PVC casing pipe (class 'B') confirming to standard specifications (schedule-80 and schedule -120 for slotted pipe)
i)Schedule 80
100mm dia PVC casing pipe (class 'B') confirming to standard specifications (schedule-80 and schedule -120 for slotted pipe)
i)Schedule 120
Cleaning and developing the tube well with compressor continously till clear adequate discharge (minimum 10 hours) is obtained from tube well. it includes supply and use of necessary equipment and labour as per direction Engineer in charge.
Supplying materials and labour,T&P and providing saline sealing by concrete grouting of annular space around PVC housing pipe in required depth and as per specification to plug the bore hole including cost of cement all complete as per direction of Engineer in charge.
Providing and fixing G.I pipe complete with G.I fittings including trenching and refilling etc. 65 mm dia nominal bore
Supply and install submerssible type flat cable ( 3 core x 4 sqmm) for submersible pump including jointing all complete
Providing and fixing gun metal gate valve with C.I wheel of approved quality (screwed end):40mm nominal bore.
Supplying and packing of gravels as per specification and direction of Engineer in charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.
(a) 15 mm nominal outer dia Pipes
(b) 20 mm outer dia pipes
(c) 25 mm outer dia pipes
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work
(a) 32 mm dia nominal bore
(b) 50 mm dia nominal bore
(c) 80 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
(a) 32 mm nominal bore.
(b) 50 mm nominal bore
(c) 80 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (a) 25 mm nominal bore.
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
Providing and placing on terrace (at all floor levels) Water Tank Triple Layered water storage tank with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
a)500 litre Circular tank.
b)1000 litre Circular tank.
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber, insertions etc. complete (The tail pieces, tapers etc if required will be paid separately). (a) 50 mm dia.
Providing and fixing in position C.I 560 mm dia cover with frame (Heavy duty) manhole cover of approved quality . (a) Circular shape 560 mm internal dia.
SUBHEAD - XIV : EXTERNAL SEWERAGE SYSTEM & 100 USERS SEPTIC TANK:
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:
(a) 100 mm diameter.
(b) 150 mm diameter.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all around S.W pipe including bed concrete as per standerd design
(a) 100 mm diameter.
(b) 150 mm diameter.
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type. (a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
(a) 450 mm dia RCC pipe
b) 600 mm dia. R.C.C. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of RCC pipes including bed concrete as per standard design :
a) 450 mm diameter pipe
b) 600 mm diameter pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : (a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
Extra for depth for manholes : Size 90x80 cm. (a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (a) All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a)1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
b)1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
a) All works upto plinth level.
Add / Deduct for using extra cement in the items of design mix over and above the specified cement content therein.
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. a)Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundations, footings, bases of columns etc. for mass concrete.
b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
c) Suspended floors, roofs, landings, balconies and access platform.
Providing of 6mm cement plaster of mix in all surface with: (a) cement mortar 1:3 (1 cement : 3 fine sand) at all levels.
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : (a) Serrated with central bulb (225 mm wide, 8-11 mm thick)
SUB HEAD - XV : EXTERNAL DRAINAGE WORK:
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (a) All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : (a) Cement mortar 1:6 (1 cement : 6 coarse sand.
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. (a) 20 mm cement plaster.
SUB HEAD - XVI : ROAD WORK:
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge: (a) All kinds of soil.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Supply and laying of moorum (of plasticity index <6) in road embankment to proper grade and level in layer of 150mm thickness and consolidating with road roller to achieve the modified proctor density of 97%, all complete as per drawing, specficiations and directions of Engineer-in-Charge.
Construction of Granular Sub-Base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all eads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (a) With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30.
Construction of Dry Lean Cement Concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc.complete as per direction of Engineer-in- charge.
Supply and laying polythene sheet of 125 micron thick complete as per direction of Engineer-in- charge.
Providing and laying in position ready mixed M-30 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately)
SUB HEAD - XVII : HARD STANDING
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge: (a) All kinds of soil.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Supplying and filling in plinth with river sand under floors, including watering,ramming, consolidating and dressing complete.
Supply and laying of moorum (of plasticity index <6) in road embankment to proper grade and level in layer of 200mm thickness and consolidating with road roller to achieve the modified proctor density of 97%, all complete as per drawing, specficiations and directions of Engineer-in-Charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying in position ready mixed M-30 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately)
Providing and laying of hard shoulder in dressing,raming,etc.Completed as per direction of the Engineer-in-charge.
SUB HEAD - XVIII : CHAIN LINK FENCING:
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
a)All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level
a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Steel work welded in built up sections/ framed work,including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
a) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Applying priming coat:
a) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
a)Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade
SUB HEAD - XIX : CONCERTINA COIL OVER EXISTING BOUNDARY WALL
Drilling hole in existing between for inserting angle iron post to support concertina coil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level
a) 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Structural steel work riveted, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire,stud tied with G.I. staples and G.I. clips to retain horizontal, including necessarybolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire ofhigh tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
SUB HEAD - XX : ARBORICULTURE:
Supply of Grass and planting by dibbling the area including watering & Maintenance of Lawn for 30 days or more till grass forms a thick lawn cushion free from weeds. With Doob Grass (15 cm x 15 cm apart) including one year maintenance after completion of work.
Trees:- Digging of pits of size 1x1x1m and refilling with good agriculture soil and well decomposed cattle manure in 4:1 ratio. Supply and planting of approved Tree species of healthy grownup saplings with good root system. Saplings should be of minimum 4 ft height from ground level after plantation. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, training, pruning, staking and spraying of insecticide and fungicide, including one year maintenance after completion of work.
Shrubs: Digging of pits of size 0.60x0.60x0.60m and refilling with good agriculture soil and well decomposed cattle manure in 3:1 ratio. Supply and planting of approved Shurbs species of healthy grownup saplings with good root system. Saplings should be of minimum 2 ft height from ground level after plantation. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, training, pruning, staking and spraying of insecticide and fungicide,including one year maintenance after completion of work.
Hedges: Digging of trenches of size 0.30 x 0.30m (width & depth) and refilling with good agriculture soil and cattle manure in 4:1 ratio. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, pruning, shaping and spraying of insecticide and fungicide,including one year maintenance after completion of work.
Flower Beds: Digging upto 0.10m refilling with good soil and cattle manure in 3:1 ratio. Preparation of beds supply and planting of healthy grown up plant material. Maintenance includes regular watering, de-weeding, manuring with manure and fertilizer.pruning, shaping and spraying of insecticide and fungicide,including one year maintenance after completion of work.
Potted Plants: Supply and maintaining the Indoor and Outdoor potted plants in a good healthy and disease free condition of various varieties and in 300 mm Dia.PVC Plastic Pot.
Pipe Line:- Supply, fixing, testing and commissioning of HDPE pipes with spray nozzles ISI mark with all required accessories, outlet points etc., (excluding excavation in hard rock if any will be measured separetly) in all kind of soil, back filling and ramming as required and disposal of surplus earth within the site, as directed by Engineer - in - charge.
i) 50mm dia
ii) 63mm dia
SUB HEAD - XXI : FURNITURE WORK:
Supply of Single seater sofa made out of teakwood framework 25 x 50mm for the seat and back flat plastic newar strips for seat and back cladded with 100m thick high density foam for seat and 75mm thick for back, 12mm thick poly foam contouring with cotton lining cloth, upholstered with fabric of approved shade, armrest of 95 x 22mm wide of TW section and polished with melamine polish etc complete. Make Godrej /Wipro/Featherlite.
Supply of 3 seater sofa in approved configuration of size 1850 x 750 x 700mm made out of teakwood frame work, seat and back with 2nd class hard wood , seat cushioned with 75mm thick high density foam and extra padding with 20mm thick foam for making shape on seat & back. Back with 50 mm thick high density foam duly upholstered with fabric of approved shade & quality all exposed wooden surface finished with Melamine polish etc. all complete. Make Godrej /Wipro/Featherlite.
Supply of Center Table 1000 x 525 x 400 mm with frames and legs made out of 60 x 35 mm teakwood sections with 10 mm thick glass on top, top frame and legs polished in melamine finish etc. Make Godrej /Wipro/Featherlite.
Supply of steel stool with adjustable height (600mm hight) black powder coated with metal pedestal, seat duly upholstered with approved quality of cushions fabric & rubber foam etc.all completed all as directed by the Engineer in charge.
Supply of Officer Table of size 1500 x 900 x 750 mm made out of 18mm plywood with 1 mm thick laminated of approved shade with four drawers and with front of 12mm thick with all exposed edges to have teakwood beading with melamine poilish finish and all internal surfaces with 0.8 mm laminate Make Godrej /Wipro/Featherlite
Supply of Officer Chair high back revolving type ofize 515mm x 515mm x 850mm with back height 900mm Synchro Mechanism and fitting and gas lift system, with PU arms with nylon base twin castor wheels with seat & back cushion with fabric of approved shade. Make Godrej /Wipro/Featherlite
Supply of working staff table of size 1200mm x 750mm x 750mm made out of 19mm thick finished with two or more coat of spirit polish afate wood filler,all necessary hardware and fittings shall be of SS 316 grade and as per direction of Engineer in Charge. Make Godrej /Wipro/Featherlite
Supply of staff Chair of size 510mm x 410mm x 800 mm with revolving type, synchro fit mechanism and cushions for seat and high back with upholstery of approved shade and casters etc., as per direction of Engineer in Charge. Make Godrej /Wipro/Featherlite
Supply of working chair of size 510 mm x 410 mm x 800 mm height including melamine polish etc.all complete all as directed by the Engineer in charge.Make Godrej /Wipro/Featherlite
Supply and placement of Executive table 1800mm x 900 mm x750mm, Primary Work Surface: Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping., Modesty Panel: Made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top, Understructure: Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Panel Drawer Slides. Drawer extension is 325 MM. Drawers have a soft closing & anti slam mechanism. Handles are provided for ease of opening. Pedestal is provided with lock for security. (All dimensions tolerance will be +/- 10mm). Make Godrej /Wipro/Featherlite
Supplying of Revolving Chair for Executive with high back revolving type 560 mm x 590 mm x 1100 mm with Synchro Mechanism and fitting and gas lift system, with PU arms with nylon base twin castor wheels with seat & back cushion with fabric of approved shade. Make Godrej /Wipro/Featherlite.
Providing and fixing of conference table (U Shape Design) for 21 persons of 1350 mm wide and 750 mm height made out of 18mm thick plywood for frame work, shelf foot rest and front facia, provision to accommodate conduits for writing front, top and side end surfaces to have 3.5 mm thick approved shade veneer panelling, exposed edges of plywood covered with teakwood beading, exposed veneer of top shall be finished with PU polish of approved shade, ends and fronts veneered surface finished with mallamine polish, internal exposed surface of the table finished with laminate etc complete of Make Godrej /Wipro/Featherlite
Supply of Conference Chair revolving & tilting chair with medium back cushioned of 50mm rubbers fabric including hydraulic jack gas lift size 515 mm x 515 mm x 850 mm complete all as approved and directed by the Engineer in Charge.Make Godrej /Wipro/Featherlite
Supplying of Book shelf of size 1800mm x 450mm x 750mm finished with two or more coat of french spirit polish over a coat of wood filler.All the necessary hardware and fittings shall be of SS (316 Grade ) and as per direction of Engineer in Charge.
Providing and fixing of Book case: Diamension :840mm (W) X 305mm (D) x 1675 mm (H).Rigid Knock down construction. Prime Quality CRCA steel - Panels & frame from 0.8mm thick, Door Features/Locking:Each Door has 10Lever lock with common key .Each Door has 3mm thick transparent glass for clear inside vision secured in a metal Frame through rubber gasket.Each Door has a Scissor mechanism for receding inside the top of respective compartment .Each Door has plastic side end caps as Handles which is easy to grip,storage shelving :Each compartn=ment has storage shelf. Finish: Epoxy Polyester Powder coated to the thickness of 50 microns etc.all complete.(Make -steelco/Equivalent)
Supply of Standard steel Almirah Double Portion of size 2000mm x 1200mm x 480mm depth in two individual compartment each 1000mm x 1200mmx 480mm depth conform to IS:3312-1984 having following specifications:
a) Bottom Pedstal.
b) 18 guage body and shelve.
c) Electroplated handle latch 2nos
d) Brass Lock 2nos.
e) Adjusting strip for shelves(Both compartment)
f) Wardrobe with aluminium rod of swg for top quoter portion (both compartment)
g) Powder coated as specify powder coating should be treated by seven tanks process repectively with one lectrolytic deep process to produce protecttive oxide coating for smooth surface with mat finish anticorrisive automated powder coating paint of thickness 60micron (Colour shall be got approved by Engineer in charge).
Supply of standared steel Almirah ( Medium) of size 1266 x 750 x 430 mm (20 gauge in top, bottom & doors and 22 gauge on sides,back & shelves) with 3Nos shelf with locking arrangements and key in duplicate and of approved by Engineer in charge.
Providing & fixing overhead Cabinet made out of 19mm thick commercial board with 4mm thick teak veneer having vertical and horizontal shelves,shutters with 19mm thick commercial board with 4mm thick teak ply includig 450mm depth necessary hardware fittings, locking arragement of hettich/haffle make etc.back with 6mm thick ply, edges covered with teak wood lipping finish with melamine polish having high gloss polyester coat etc.all complete.
Supply of Side Rack for Tray made out of MS angel, size of 900 x 900 x 380 mm with 3 panel (open type)properly painted complete all as directed painted complete all as directed by the Engineer in charge.
Supplying and fixing wooden cupboards with 19mm thick commercial board for sides top,bottom/base and 6mm thick commercial ply on back complete.The cupboard shutters will be 19mm thick commercial board with 1.0mm thick decorative lamination outside and 0.8 mm inside including IInd class 4mm thick teak wood lipping /pvc lipping on edges including necessary screws and bright finished stainless steel piano hinges/self closing hinges,as handles.door catchers ,locks etc complete hardware as per direction of Engineer in charge.The inside portion including back surface shall be laminated with 0.8mm thick white lamination all complete 600mm deep.
Supply of Work Bench 1800 x 900 x 750mm high made out of teakwoodframework of size 100 x 30mm thick and top to have 25mm thick plywod with 1mm thick lamination on top and having 3 drawers and footrest with 50 x 30 mm teakwood section .2 shelfs on top of the table,made out of 19mm thick plywood with lamination and providing 2 nos. of 5/15 Amps Power Socket etc,all complete with melamine polish etc.all complete as directed /approved by the Engineer in charge.
Supply of Display unit 450mm deep made out of 19mm thick commercial board with veneering on top with all exposed surfaces to have melamine polish and decorative moulded teak wood beading on all edges and making different compartment to have separate transparent frames glass cover of thickness 10mm glass with etching on sides with SS hings and back with Teak board 12mm thickness etc.all complete.
Supply of Dining table of overall length of the dinning table for 6 persons 1500mm x 900mm,height of the table 750mm.wooden legs of asize 75mmx75mm all around 18mm ply with 1mm lamination on the top fitted with screws to the frame from the bottom.Two side stiffeners and one centre stiffener shall be provided complete with spirit polish.Make Godrej /Wipro/Featherlite.
Supply of Dining chairs novella of size 510mm x 410mm x 800 high with back height 960mm shall be provided complete with spirit polish.Make Godrej /Wipro/Featherlite.
SUB HEAD - XXII : AREA DEVLOPMENT:
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete
SUB HEAD - XXIII : WATER COOLER :
Aquaguard Purechill RO storage Cooler cum Purifier with its one of a kind purification technology (RO),with cooling and storage solution of following specification.Approximate External Diamension (WXDXH) 640X450X1350mm Operating Power Supply 230 ±10% V AC,50Hz b)Filter Catridges-Sediment,Activated Carbon,Carbon Block Running Current in Amps.(Max) 4.5 ± 10% Power in Watts(Max) 700 ± 10 % Water Storage Tank Capacity 80Ltr. Capacity with Comfort Level Water Outlet Temperature at 17°C ± 1° C 60 Ltr Compressor Make Copeland or Tecumseh Refrigerant Freon 22 Stages Details.
1.Particulate Filter
2.Pre Carbon Block Filter
3.Anti Scalant Filter
4.Sediment Filter
5.Reverse Osmosis membrane Filter
6.Post Carbon Block Filter
7.Nano Silver Leaching Filter
RO Membrane Rating 4No.x75 GDP or Equivalent Make.Kent/Eureka forces or equivalent
SUBHEAD- XXIV : INTERNAL ELECTRIFICATION:
Lights Points
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 5/6 A modular switch, connections etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the modular plate switch box including connections, modular plate etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Light/Fan Fixtures
Supply of the following LED Light Fixtures with electronic driver , heat dissipating element including necessary accessories etc., complete on wall/ Ceiling / suspended from ceiling/ recess including all fixing accesssories such as leads,Teak wood round block, downrods, MS clamps, nuts, GI chain and bolts etc complete as required.
36W LED luminaire Recess Mounted 2ft x 2ft LED Luminaire with Diffuser similar to Philips Cat No: SM366C LED32-6500 PSU OD WH / Equivalent Make of Wipro.
15W LED Luminaire Recess mounted circular square LED downlighter Philips Cat No:SM251C LED16S- 6500 PSU WH / Equivalent Make of Wipro.
12W LED Luminaire surface mounted circular LED downlighter similar to Philips Cat No:SM250C LED12S- 6500 PSU WH / Equivalent Make of Wipro.
40W LED Tube Light similar to Philips Cat No:BN100C LED40S-6500 PSU L120 GR / Equivalent Make of Wipro.
20W LED Tube Light similar to Philips Cat No:BN 021 LED25S 6500 PSU GR S1 / Equivalent Make of Wipro.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Ceiling Fans
Supply of 1200 mm sweep 5star rated Ceiling fan with standard down rod, all accessories Electrical connections. Including fixing materials as required.
Installation, testing and commissioning of ceiling fan/Wall mounted Fans, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Exhaust Fans
Supply of heavy duty Exhaust fans with Non Metallic blades following size sweep with gravity louvres shutters Exhaust fans with Metallic blades of following.
300mm Sweep 900rpm
Supply of Exhaust fans with PVC blades following size sweep with gravity louvres shutters Exhaust fans of following
200mm Sweep 900rpm
Installation of exhaust fan in the existing opening, including making good the damage,connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
8 way (4 +24), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current breaker with Overload (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 A, Four Pole, RCBO, 100mA.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
8 way, Double door
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, RCBO having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25 A DP RCBO, 100mA
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5A - 32A, Single pole, MCB, 10kA
Supplying,installation,testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
SUBHEAD- XXV : POWER WIRING
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (4 + 24), Double door
4 way (4 +12), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current breaker with Overload (RCBO), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 A, Four Pole, RCBO, 100mA.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5A - 32A, Single pole, MCB, 10kA
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
SUBHEAD-XXVI : SHOP ELECTRICALS
ELCTRICAL PANEL
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA/Galvanised steel enclosure for main frame and 1.6mm thick partitions and shall have IK Certification as per IEC 62262 for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.The panel shall be got fabricated from manufacturers as per IEC 61439(Part-1&2). Indoor panels shall have IP-4X degree of protection and Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose.
BUILDING MAIN PANEL
INCOMER
MCCB, with Microprocesssor release with 400Amps, 50kA, FP,. - 1 SET
Incomer shall have one set of the following items:
0 - 500V Digital Volt meter - 1No.
0 - 400A Digital Ammeter- 1 No.
Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc and LED display with required Nos CTs, 15 VA, class 1 class and control circuit wiring with MCBs - 1 No.
1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
BUS BAR
FP Alluminium busbar of 400A with 50 KA fault level capacity, mounted on non-hygroscopic, glass fibre reinforced insulators-1Set
OUTGOINGS
125A, 25KA TPN MCCB (Thermal Magnetic Release)- 2No
100A, 25KA TPN MCCB(Thermal Magnetic Release)- 2Nos
63A, 16KA TPN MCCB (Thermal Magnetic Release)- 15Nos
63A, 25KA TPN MCCB with TVSS - 1set
1 Lot of control wiring & outgoing feeder indication lamps 1 Set of designation plates.
Two numbers 50mm X 6mm GI earthing terminals - one on each side of the panel with earth strip run inside the panel
Supply of following size 1.1KVgrade XLPE insulated armoured aluminium conductor underground cable, The cable shall conform to IS 7098 Part-1.
3.5C X 185 Sq.mm Aluminium
3.5C X 35 Sq.mm Aluminium
4C X10 Sq.mm Aluminium
3C X6 Sq.mm Aluminium
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
a) Upto 35 sq. mm (clamped with 1mm thick saddle)
b) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE/ copper conductor cable of 1.1 kV grade as required.
3½ X 185 sq. mm (57 mm)
3½ X 35 sq. mm (32 mm)
4X10 sq. mm (25 mm)
3X6 sq. mm (16mm)
Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm Copper strip on surface or in recess for connections etc. as required.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.d.
450 mm width X 50 mm depth X 2.0 mm thickness
200 mm width X 50 mm depth X 1.6 mm thickness
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
150 mm dia. R.C.C. pipe
SUBHEAD-XXVII : TELEPHONE/LAN CONDUTING
Supply and laying of 25mm dia. Medium class PVC conduit concealed in wall/ ceiling/floor including all accessories such as junction boxes, conduit bends, etc completed as required for Telephone
Supply and laying of 25mm dia. Medium class PVC conduit With GI Fish Wire of 1.6mm(16swg) shall be provided with in concealed in wall/ ceiling/floor including all accessories such as junction boxes, conduit bends, etc completed as required for Lan etc.,
Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate and plug in type telephone socket .
Supply and laying of 2pair 0.5mm dia PVC insulated Copper conductor Telephone wire conforming to DOT Specification
Supply and fixing of LAN outlet (RJ45) with anodised GI box with front plate and plug in type LAN socket .
SUB HEAD-XXVIII : LIGHTNING PROTECTION SYSTEM
Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and laying of following size strips including all necessary inter connections between earth station and equipment. supports for strips as applicable .
32 X 5mm Aluminium strip with DMC Insulated Supports
50 X5mm GI strip laid in ground
Supply and installation of vertical air termination with 40 mm dia copper hollow sphere with spikes, fixed on 1000mm length 25mm dia Copper tube including all fixing accessories..
Supply and installation of Test link fuse as required complete set
SUB HEAD- XXIX : EXTERNAL POWER SUPPLY
11KV 630A 25KA EDO 3P VCB indoor type with Digital Voltmeter with PT, digital Ammeter with CTs, Digital PF Meter, Digital load manager, Overload & Earth Fault relays of Numerical type, Phase Indication Lamps, Breaker On/ Off/ Trip and Spring Charge, and Trip Circuit healthy Indications along with builtin power pack suitable for 2 `ON' & 2 `OFF' operations – 1set
Supply, erection, testing and commissioning of Metering cubicle with ERDA tested CTs and PTs complete with NABL Testing. (Supply & Erection of 11KV outdoor type CT, 15VA Burden 0.5CL, 100/1A and Supply & Erection of 11KV indoor type PT, 100VA Burden 0.5CL)-Indoor panel
supply, installation, testing and commissioning at site 11 KV/433V, 3 phase, 50 Hz delta/star connected, 500KVA transformers CRT Dry Type with enclosoure, complete with all fittings such as thermometer, explosion vent, Local ON LOAD tap changer with AVR , diagram & rating pkte, oil temperature indicator, winding temperature indicator and buccholtz relay with wiring upto marshalling box, lifting lugs, first filling of oil, weather proof HT cable box, LT Cable box etc. complete as per specification Make: ABB/schneider/crompton greaves.
Supply, Testing and commissioning of 0.433kV, 3Ph., 50Hz., 500KVA, 0.8 PF DG set with AMF control panel with canopy. The diesel engine shall be complete with necessary control and safety devices as per IS/BS specifications. The engine shall be suitable for continuous operation of Generator duty, inclusive of fly wheel, flexible coupling, air cleaner, corrosion resistor, fuel pump, fuel filter, electronic governor, 990 liters free standing fuel tank,starting system with separate battery charger with 2Nos. 12V Lead Acid Batteries as required,voltage regulator, Instrument panel with RPM indicator, Exhaust silencer (residential), protection against low lube oil pressure, high water temperature. Fuel lines from fuel tank to DG set, battery stand, anti vibration pads and first filling of lubricating oil and fuel oil for set. The Alternator shall be suitable for 0.433KV 3phase 50Hz AC Supply operation and shall be able to deliver full load current at 100% Unbalanced load. As per the CPCB 2 norms.
Supply of exhaust piping with 6" MS 'B' Class black pipe (4.8 mm thickness of jindal make)with necessary bends,flanges & angular supports with aluminium cladding with mineral wool 2 Runs X 17 mtrs including structure for open area D.G.Set installation
Supply and commissioning of following size 11KV (E) grade XLPE insulated armoured aluminium conductor under ground cable, The cable shall conform to IS 7098/ Part I.
3C X 185 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/HUME/ METAL pipe as required.
Above 120 sq. mm and upto 400 sq. mm
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
3C X 185 sq.mm
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA/Galvanised steel enclosure for main frame and 1.6mm thick partitions and shall have IK Certification as per IEC 62262 for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.The panel shall be got fabricated from manufacturers as per IEC 61439(Part-1&2). Indoor panels shall have IP-4X degree of protection and . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose. and Cable Entry Bottom.
MAIN PCC PANEL
EB & DG INCOMERS
ACB, with Electrically Draw out with O/C,S/C,E/F 1000Amps, 50kA, FP,. - 2 SET
Incomer shall have one set of the following items:
0 - 500V Digital Volt meter - 2 Nos.
0 - 1000A Digital Ammeter- 2 Nos.
Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc with and LED display with Core Balance CTs of ratio 1000/1A Class 1Accuracy and 10VA burden and control circuit wiring with MCBs - 2 No.
Core Balance CTs of ratio 1000/1A Class 1 Accuracy and 10VA burden for Referal –2 sets.
Core Balance CTs of ratio 1000/1A Class 1 Accuracy and 10VA burden for APFCR panel –1 set.
1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
BUS BAR
FP Alluminium busbar of 1000A with 50 KA fault level capacity, mounted on non-hygroscopic, glass fibre reinforced insulators-1Set
Change Over Switch
1000A 50KA 4P Motorized Chage Over set-1 No
OUTGOINGS
400A, 50KA TPN MCCB (Thermal Magnetic release)- 3Nos
200A, 35KA TPN MCCB (Thermal Magnetic release)- 2Nos
125A, 25KA TPN MCCB (Thermal Magnetic release)- 2Nos
125A, 25KA TPN MCCB (Thermal Magnetic release) with 50 KVAR Fixed capcitor - 1Nos
63A, 16KA TPN MCCB (Thermal Magnetic release)- 2Nos
40A, 16KA TPN MCCB (Thermal Magnetic release) with S/D Starter for Bore Pump - 1Nos
40A AC1 Contactor with 230V Coil and a Time Switch similar to L&T TSQ 100 -1set
40A, 10KA DP MCB (Thermal Magnetic Release)- 3Nos
63A, 25KA FP MCCB with TVSS - 1set
Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc and LED display with required Nos CTs, 15 VA, class 1 class and control circuit wiring with MCBs - 8 Nos.
1 Lot of control wiring & outgoing feeder indication lamps 1 Set of designation plates.
Two numbers 50mm X 6mm GI earthing terminals - one on each side of the panel with earth strip run inside the panel
APFC PANEL
INCOMER
MCCB, with Microprocesssor based release 400Amps, 50kA, FP,. - 1 SET
Incomer shall have one set of the following items:
0 - 500V Digital Volt meter - 1No.
0 - 400A Digital Ammeter- 1 No.
Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc and LED display with required Nos CTs, 15 VA, class 1 class and control circuit wiring with MCBs - 1 No.
1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
BUS BAR
FP Alluminium busbar of 400A with 50 KA fault level capacity, mounted on non-hygroscopic, glass fibre reinforced insulators-1Set
OUTGOINGS
100A, 25KA TPN MCCB (Thermal Magnetic Release) with power contactor & 25 KVAR capcitor - 2Nos
63A, 16KA TPN MCCB (Thermal Magnetic Release) with power contactor &15 KVAR capcitor - 6Nos
40A, 16KA FP MCCB (Thermal Magnetic Release) with power contactor &10 KVAR capcitor - 4Nos
1 Lot of control wiring.& outgoing feeder indication lamps 1 Set of designation plates.
Two numbers 50mm X 6mm GI earthing terminals - one on each side of the panel with earth strip run inside the panel
Supply of following size 1.1KVgrade XLPE/PVC insulated armoured aluminium conductor underground cable, The cable shall conform to IS 7098 Part-1.
3.5C X 300 Sq.mm XLPE Aluminium
3.5C X 240 Sq.mm XLPE Aluminium
12Cx2.5sq.mm Flexible Cable
19Cx2.5sq.mm Flexible Cable
4Cx2.5sq.mm Flexible Cable
2Cx2.5sq.mm Flexible Cable
3Cx4sq.mm Flexible Cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 185 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE/ copper conductor cable of 1.1 kV grade as required.
3½ X 300 sq. mm (70 mm)
3½ X 240 sq. mm (62 mm)
12Cx2.5sq.mm (32mm)
19Cx2.5sq.mm (32mm)
4Cx2.5sq.mm PVC (16mm)
2Cx2.5sq.mm PVC(12mm)
3Cx4sq.mm PVC Aluminium control Cable (16mm)
Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 75 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.
Supplying and laying 50 mm X 6 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.
Providing and fixing 75 mm X 6 mm G.I. strip in exisitng trench for connections etc. as required.
Providing and fixing 50 mm X 6 mm Copper strip in exisitng trench for connections etc. as required.
SAFETY ITEMS
Supply of the following safty as per standards and specification
Fire Extinguishers - 4.5 KG CAPACITY CO 2 Confirming to IS 2878 fitted with discharge bend pipe and horn fitted on wall
Rubber Mats 11kV, 2 m x 1 m
Rubber Mats 415 V, 2 m x 1 m
Shock treatment Chart with wooden frame and glass
First Aid Box
3 Nos of buckets with canopy & stand
415 V Danger Boards
11KV Danger Boards
11 KV Hand Gloves
SUB HEAD-XXX : AREA LIGHTING
Supply and erection of steel stepped and swaged tubler poles of 7.5mtr. Long (1.5mtr below Ground) with Suitable curved single arm of 1.5M x 48.4mmx3.2mm-(LengthxODxThickness) With All over all Legth of Section-Bottom Section:4.5m x 114.3mmx 5.4mm Middle Section 1.5m x88.9mm x4.85mm top Section: 1.5m x76.1mmx3.25mm,with IS-2713-80 with latest amedment 410-SP-6 with 300x300x6mm M.S Base Plate as per drawing and specfication including one coat of red oxide and two coats of approved colour painting and ckt making including suppling all erection of 1:2:4 ratio cement concreate foundation with coller including excavation in all kind of soil and required as per specfication with Luminaries HAVELS 70W ENDURACITYLINERNEOSL70WLED757PASYBOTG
Supplying and laying 6SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection/ terminating with G.I. thimble etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (without charcoal/ coke and salt) as required.
Supplying and fixing of 40mm dia PVC Pipe on the Pole for Cable Entry to the Junction box as required
Supplying and fixing of 202x238x111(KVPC) polycarbonate thermoplastic enclosure junction box with IP -65 protection with cable hinged cover of approved degin complete having gasket of internally embedded & made of polyeuthereme & should be weather prrof, rust prrof, dust prrof water prrof-box shall be tested as per IEC-60670-2/60670-22. the box shall have threded holes & provision for mounting dim rail with 2nos cable gland including suplying & fixing crimping 2nos of lungs * 1no 32A conncetor 6way for looping the incoming and cables and also connection of the street light one 6A SP MCB including connection of 2x6sqmm cable as required
Supply of following size 1.1KVgrade XLPE insulated armoured aluminium conductor underground cable, in built up cable trench/ already laid RCC hume pipe / on surface of slab and walls with clamps or on cable tray with all installation materials. The cable shall conform to IS.
3C X 6Sq.mm Aluminium
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required
Upto 35 sq. mm
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including etc. complete : testing of joints
100 mm dia. R.C.C. pipe
SUB HEAD-XXXI : AIR CONDITIONING SYSTEM :
Supply ,Installation , testing and commissioning of the following capacity Hi wall split unit( Indoor and out door units) equiped with 3star Rated Inverter model Power Saving Imported Compressors, Suitable expansion device for optimal refrigerant feed, constructed with lightweight Galvanized sheet steel etc This unit is equiped with Microprocessor based controller having unique features to ensure that system operates at optimum efficiency levels etc. the price includes power and control cables along with 3 RMT Copper piping for indoor to outdoor etc complete.The unit should be with eco friendly refrigerant R410a, MS Stand for Condensing unit , Wire less remote control etc Make : Carrier / voltas / Bluestar/Hitachi /Daikin
a) 2TR Actual capacity (3 STAR INVERTER TYPE)
b) 1.5TR Actual capacity (3 STAR INVERTER TYPE)
Supply , installation , testing & commissioning of Refrigerant copper piping for optimum velocities for better return of lubrication and optimum pressure drops. Copper piping measured other than the 3 RMT from the manufacturer . Piping should be insulated with 13 mm thick EPDM insulation covered with factory laminated glass cloth . To be finished with poly caot protected paint. Make for copper pipe : Mandev / Yaash / Totaline ,Make for Insulation : K flex / Armaflex/ Superlon
a) Liquid line
b) Suction line
Supply, Installation, testing & Commissioning of the drain line with cpvc pipes along with 6mm thick closed cell nitrile rubber insulation of the following sizes .Make for cpvc : Sudhakar / Supreme ,Make for Insulation : K flex / Armaflex/ Superlon
a) 25mm Dia
Supply,fixing,testing and commissioning of following capacity Stabilizers incluing all fixing accessories
Supply,fixing,testing and commissioning of 3 core 1.5 sqmm CU flexible for communication cable
SUB HEAD-XXXII :FIRE FIGHTING SYSTEM
Supplying, delivery, Transport, installation , testing and commissioning of Mild steel Black ERW Medium grade piping as per IS : 1239 / IS:3589 6mm thick. The pipes complete with necessary specials such as tees, bends, flanges, reducers, etc. Rate quoted shall include for painting of pipe with a coat of primer and two coats of synthetic enamel paint of approved colour / make for aboveground piping and coating & wrapping for underground piping as per the TAC / IS standards and Local fire service department requirement including supply and installation of pipe supports, fasteners etc. complete in all aspects as per specifications and as directed by departmental officers, Above ground piping with necessary flanges & fittings such as elbows, tees and Painting, supports and Orifice plates if any necessary for the fire protection system complete as per the requirement of Local fire service department.-B-Class MAKE: Tata /ZENITH/Apollo. a) 200mm dia
Supply installation testing and commissioning of Fire brigade inlet with 2 built in NRV and One Sluice valve with glass cover box and interconnections etc complete.
Supply, erection, testing and commissioning of Single Headed Fire Hydrant with 63 mm female instantaneous outlet in oblique type complete with cap & chain generally as per IS 5290.'
Supply & fixing 63 mm dia Cotton Synthetic Fibre (RRL) Woven rubber lined fire hose delivery treated against rot with MYSTOX, conforming to IS 636 type 'A' bounded with male and female instantaneous G.M. couplings and of length of 30 M.
Supply and fixing of Gun Metal branch pipe 63 mm dia, male and female threaded outlet complete with hexagonal base bore nozzles as per IS 903.
Supply and fixing of Fire Hose Box of MS of size 3 'x 2' x 1'6" to accommodate two numbers of 30 M length hoses and branch pipe, glass fronted, double door with lock painted fire red outside with suitable structural support complete but excluding civil works.
Supply and Fixing of Cast iron Route Marker at an interval of 50 m for fire fighting system including PCC (1:2:4).
Supply installation,testing and commissioning of Monoblock type450 LPM at 35m head BOOSTER PUMP, monoblock type centrifugal pump of standard fitted construction with impeller, with suitable HP with required fitings& Valves etc complete.
Supply, fabrication, testing and commssioning of Mild Steel Heavy Class "C" Pipes as per IS 1239 with required fittings.
The scope includes,the entire piping finished with redoxide primer and two coates of enamle spray paint.
a)100 mm dia
b) 80 mm dia
Supply and installation of Cast Iron Butterfly valve as per IS 13095, lever operated PN 16. With required fittings
a)100 mm dia
b) 80 mm dia
supply, installation, testing and commissioning of weather proof type MPCB box made out of 2mm thick CRCA sheet includig painting with epoxy powder coating for suitable HP boosger pump motor. The box work of 450mm height on a PCC pedestal including all materials . Outgoings : DOL starter for 15HP with MPCB and contractor, over load relay , single phasing preventor and ON/OFF/ TRIP
Supply, installation, testing and commissioning of CI flanged Y type strainer with SS screen , PN 16 complete with sutiable flanges,nuts, bolts, gaskets etc complete.
a) 80mm Dia
Supply and fixing of CI wafer type non return valves as per IS 5312
a) 80mm Dia
supply, fixing of 25mm brass air relasing valve and accessories
supply, installation, testing and commissioning of Pressure gauges for pump
supply, installation, testing and commissioning of pressure switch for pump auto on off mode
MV Cables for Pumps
Supply, laying and commissioning of following size 1.1 KV grade PVC insulated , sheathed steel strip/ wire armoured / flexiable copper conductor under ground cable laid in cable trench / on existing cable tray etc complete.
a) 3c x 6 sqmm
b) 2 c x 1.5 sqmm
Providing and fixing of CO2 type fire extinguishers consisting of seamless M S cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, confirming to IS :2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges
a) Capacity 4.5 Kg
Providing and fixing water CO2 type fire extinguishers consisting of welde MS cylindrical body, discharge nozzle, suspension bracket, conforming to IS : 15683 finished externally with red enamel paint and fixed to wall brackets complete with internal charges
a) Capacity 9 Kg
Providing and fixing of 9 Liters Mechanical Foam(AFFF) fire extinguisher gas cartridge type, ISI marked conforming to IS : 10204, complete with gas cartridge, delivery hose, squeeze grip release valve, locking arrangement , bracket with two screw and sleeve
Providing and fixing water/ sand bucket finished externally with red enamel paint and fixed to wall brackets, ceiling hook, shovel, fire beaters , fire axe,fire siren etc complete as required
SUB HEAD-XXXIII :FIRE ALARM SYSTEM
Supply,Testing and commissioning of the following number of Loops Microprocessor based addressable type (EN / UL approved) Fire alarm control panel with Zonal Indications, supervised inputs, supervised and non-supervised outputs,Zener barriers, two way media converter / Signal booster for in / out network connectivity with OF cableand with battery Power pack as per specifications.
a) 2 - Loop
Supply installation, testing and commissioning of analog addressable type multi sensor (smoke/ Heat) photo electric detectors with base and LED indication lamp along with all fixing accessories.
Supply installation, testing and commissioning of reponse indicators with LED indication lamp along with all fixing accessories.
Supply, Installation, Testing and commissioning of anologue addressable loop sounders along with all fixing accessories.
Supply, Installation, Testing and commissioning of fault isolators along with all fixing accessories.
Supply,Installation,Testing and commissioning of anologue addressable type monitor module along with all fixing accessories.
Supply,Installation,Testing and commissioning of addressable control module along with all fixing accessories.
Supply, Installation,Testing and commissioning of anologue addressable ordinary Manual call point with push type along with all fixing accessories.
Supply and laying of 25mm dia medium class FRLS PVC conduit concealed in wall /ceiling / above false ceiling including bends,elbows, junction boxes, saddles, spacers etc., and other material required for fixing complete as per requirement.
Supply,laying,testing of twisted pair 1.5sq mm shielded FR insulated copper conductor flexible wire in existing PVC conduit.
Supply, fixing and installation of fire exit signage's self illuminating light fixtures displaying exit with an arrow towards the exit door.
SUB HEAD-XXXIV :FIRE EXTINGUISHERS
Supply & Installation of Carbon-di- oxide type fire extinguisher of 4.5 kgs. Capacity, CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel, with wheel type valve, discharge nozzle, bend & horn, wal mounting bracket etc. complete, confirming to IS: 2878.
Supply & Installation of Water CO2 Type fire extinguisher of 9 Ltrs. Capacity, filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel, with wheel type valve, discharge nozzle, bend & horn, wal mounting bracket etc. complete confirming to IS: 940.
Supply & Installation of ABC Stored pressure type Fire Extinguisher of 5 kgs capacity with stand,fitted with discharge control valve (Squeeze grip type) CE marked and pressure gauge,filled with mono ammonium phosphate powder as per EN 3 615 approval,with discharge hose and open nozzle and supplied complete with initial charge as per IS: 15683 with ISI mark. Fire Rating 3A,21B
Surendra Infrastructure Pvt. Ltd.
M.P.KHAITAN
LIRA CONSTRUCTIONS PVT LTD
Rds Project ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid