Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L1 | Accepted-AOC AOC | |
| 2 | L2₹9.5 L+₹17,448.75 (1.88%)Rejected-Finance 3 100 2 KOTIAN CO NH66 KULAI POST SURATHKAL MANGALORE DAKSHINA KANNADA KARNATAKA 575019 | DAKSHINA KANNADA | KARNATAKA | 575019 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹9.8 L+₹46,093.50 (4.96%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 |
Tender Value
₹10.6 L
EMD Value
₹21,200
Closing Date
15 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL RAJESH KUMAR BISYAN
Military Engineer Service, GE(I) CG Goa, HQ CG DHQ-11, Chicolna, PO Bogmalo, Goa-403 806
CLEANING AND REPLACEMENT OF SEWAGE LINES AT KANKANADY, KUNJATHBAIL, PANAMBUR AT NEW MANGALORE UNDER GE(I)(CG)GOA
2022_MES_563101_1
8314
Open Tender
Miscellaneous Services
Item Rate
180 days
DHQ 3 NEW MAGALORE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (I) CG GOA
₹21,200
Yes
30 Dec 2022
15 Nov 2022
19 Dec 2022
15 Nov 2022
15 Dec 2022
30 Nov 2022
15 Nov 2022 - 25 Nov 2022
Amount
SCH A PART-I( CLEANING AND REPLACEMENT OF SEWAGE LINES AT KANKANADY, KUNJATHBAIL, PANAMBUR) Excavation in trenches, not exc 1.5M wide and not exc 1.5M in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in hard/ dense soil.
M & L PVC (SWR) Pipe 150mm bore drain pipes single socketed, in any length with rubber ring joints including demolition & breaking of old 150/110mm bore drain pipe of any length laid in trenches and jointed complete all as specified and directed.
M & L Concrete bed to 150mm bore drain pipes incl packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D2( using 40mm graded stone aggregates) complete all as specified and directed
M & L PCC 1:4:8 Type D2 using (using 40mm graded stone aggregate) in foundation,filling and mass concrete complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
M & L walling laterite stone masonary of square rubble regular coursed well bonded and solidly hearted built in cement mortar (1:6) including demolition of old unserviceable stone masonry complete all as specified and directed.
S & F for Cast iron manhole cover with frame grade FG-150, unmachined (article not exc 5kg each) including dismantling old one complete all as specified and directed. .
Taking down old unserviceable cement plaster and raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L Rendering 15mm thick cement plater (1:4) on fair faces of stone masonary or concrete surfaces to be finished even and smooth (without using extra cement) complete all as specified and directed. .
M & L Precast RCC (1:2:4) type B1 using 20mm graded stone aggregate as in man hole cover slabs etc set in cement mortar (1:4) including use and waste of form work (reinforcement shall be measured and paid for relevant item) complete all as specified and directed. ..
M & L TMT bars 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire(annealed) not less than 0.9mm dia complete all as specified and directed. .
Cutting into existing manholes for connecting new pipes of internal dia of pipe 150mm making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. .
M & L PCC type B1-1:2:4(using 20mm graded stone aggregate) in height, coping, ,kneelers,apex stones,bed plates,incl.weathering, slightly,rounded or chamfered angles and throating complete all as specified and directed. .
M & L Non-skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exc 0.06 sqm and n exc 0.11 sqm over 15mm thick bedding layer in CM(1:6) in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling etc. and removing servicable tiles to the store and rubbish off the premises complete all as specified and directed. .
M & L glazed ceramic coloured tiles vertical surface 300x200x7mm thick including10mm thick dubbing coat in CM(1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling the old one complete all as specified and directed. .
S & F for 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed. .
S & F for PVC (SWR) bend with door suitable for 110mm bore pipes complete all as specified and directed. .
S & F for PVC(SWR) branch piece (single 'Y') with door suitable for 110mm bore pipes complete all as specified and directed.
S & F for PVC SWR 'S' trap 110mm bore complete all as specified and directed.
S & F for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. ..
M & L PVC (SWR) floor trap, 75mm outlet dia., plain with grating including jointing with solvant cement, complete all as specified and directed. .
Demolition of cement concrete in ground floors and paving n.exc 15cm thickness(below or above ground level) including plinth protection complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
M & L 75mm thick PCC 1:3:6 Mix type C2 as in plinth protection and in path surface to be finished without using extra cement including demolition the old unserviceable concrete complete all as specified and directed.
Cleaning of existing septic tanks 5 to 10 users capacity by pumping out/bailing out waste water removal of sludge etc complete all as directed at site and disposing off sludge and waste water etc away from the premises of accommodations,(outside MOD land) complete all as specified and directed.
Cleaning of blocked sewage line, 150mm dia manually or by mechanical means, by rodding from one manhole to next manhole and washing through in fresh water including removing all sludge from the sewage line and manhole including removing all sludge outside MOD land removing all solid/waste materials etc. including opeing manhole cover and testing the sewage line using clear water after cleaning complete all as specified and directed. .
Cleaning of man holes of any size and depth not exc 1.50mtr including bailing/pumping out waste water and removal sludge/solid waste materials etc with tailor mounted sewage cleaning pumps/mechanical devices and disposing them to a distance exceeding 50 mtr and away from the premises of accommodations(MOD land), wells water storage tanks etc, placing the manhole over over the manhole complete all as specified and directed. ..
All as per ser Item No 27.00 above but for depth exc 1.50 mtr but not exc 3.00 mtr complete all as specified and directed. .
Cleaning of existing septic tanks 10 to 250 users capacity by pumping out/bailing out waste water removal of sludge etc complete all as directed at site and disposing off sludge and waste water etc away from the premises of accommodations(Outside MOD Land), wells, water storage tanks etc placing the manhole cover over the man hole complete all as specified and directed. .
Cleaning of Nahani/floor traps and removing any type of chocked/blockaged and removing all rubbish obtained during cleaning and despense rubbish away from the premises(Outside MOD Land), complete all as specified and directed. ..
Cleaning gully traps and removing any type of chocked/blockaged and removing all rubbish obtained during cleaning and despse rubbish away from the premises( outside MOD Land) complete all as specified and directed. .
S & F in repairs PVC connection 15 mm size with PTMT nuts of lengths 450 mm, complete all as specified and directed. .
S & F in repairs plastic water closet seat, black,closed pattern with flat bottom and cover and mild steel chromium plated hinges device complete all as specified and directed. ..
S & F in repairs health faucet CP(hand shower type) with shut off valve (thumb or flush button type) to allow controlled and continuous flow of water with flexible polythene pipe of adequate length and with wall mounted pedestal for hanging faucet including taking down of old one complete all as specified and directed.
S & F in repairs PVC flexible waste pipe 32/40mm dia for basin/kitchen sink of 1.00m long complete all as specified and directed. .
Cleaning IEC/WEC traps and revoving any type of chocked/blockaged and removing all rubbish obtained during cleaning and despse rubbish away from the premises (outside MOD land) complete all as specified and directed. ..
S & F in repairs vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), pedestal pan and trap, including connection to drain or out going pipe and to flushpipe, anti-syphonage pipe, etc complete all as specified and directed. .
Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting out in hard/dense soil all as complete all as specified and directed. .
M & L Sand filling under floors or in foundation incl watering and consolidation of 50 mm thick complete all as specified and directed. .
S & F machine pressed precast concrete interlocking paver block any shape and size with grey cement and no pigment of 60mm thickness, M-35 grade conform IS:15658-2006 complete all as specified and directed.
M & L 100mm thick Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in sub base, in floor complete all as specified and directed.
Cutting and cleaning of bushes/ vegetations including roots from ground and removing rubbish material off the premises complete and applying weedant complete all as specified and directed. Note:- Contractor shall strictly follow the " Prohibition of Employment of Manual Scavengers and their Rehabilation Act, 2013" which refers prohibits engagement or employment of any person for hazardous cleaning of sewers and septic tanks by employing manual handling of excreta in the process of their cleaning. Necessary by pass arrangement to be made in case of time consuming repairs, till the sewer line is repaired & wherever handling of human excreta can be involved necessary appropriate technological appliances(Sewage Suction Truck) will be complied with the subject Act.(For all BOQ Items)
KOTIAN -ECC
L A Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .