| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | Rejected-Technical | - | Rejected-Technical NON-RESPONSIVE | |
| 3 | Rejected-Technical 16 PRATAP NAGAR CHARBHUJA RAWATBHATA CHITTORGARH RAJASTHAN 323307 | RAWATBHATA | CHITTORGARH | RAJASTHAN | 323307 | - | Rejected-Technical NON-RESPONSIVE |
Tender Value
₹96.8 L
EMD Value
₹1.9 L
Closing Date
15 Dec 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Raj Kumar, EE
Executive Engineer, Jag Provincial Division PWD B and R Br Yamuna Nagar
Construction of Indoor Badminton Hall in Gymkhana Club at Sector -17, HUDA, Jagadhri in Yamuna Nagar District
2020_HRY_141143_3
PWD/CHD/YNGAR/1013
Open Tender
Construction Works
Works
270 days
Yamuna Nagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹1.9 L
Yamuna Nagar
19 Jul 2021
1 Dec 2020
16 Dec 2020
1 Dec 2020
15 Dec 2020
1 Dec 2020
8 Dec 2020
120 days
Amount
(Civil work) Earth work in excavation in foundations, trenches etc. in all kinds of soil, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction, including disposal of all surplus soil as directed within a lead of 30 Mtrs. (HSR 6.6)
Earth Filling under floors with surplus soil excavated from foundation and taken only from outside the building plinth, in 15 cm layers including ramming watering and consolidating lead up to 30 meters. Subject to condition soil Is non plastic. [HSR 6.13(a)].
Cement concrete 1:8:16 with stone aggregate 40mm Nominal sie in foundation and plinth. (HSR 10.28)
Cement concrete 1:4:8 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.38)
Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work in Shelves excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respect. [HSR. 10.81+10.95 (a)]. First Storey
Cement concrete 1:1½:3 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respect. [HSR. 10.82 + 10.95 (a)]. First Storey
SECOND Storey
Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (Straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centring and shuttering, laid in position complete in all respects. [HSR. 10.86 + 10.95 (a)] First Storey
SECOND Storey
THIRD Storey
Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work in fasicas, parapets and other thin vertical sections, not covered by item no. 10.82, 10.86 to 10.88 not exceeding 10 cm thickness thickness excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects. [HSR. 10.89 + 10.95 (a)] Second Storey
Cement concrete 1:1½:3 with stone aggregate 20mm nominal size for reinforced concrete work in footing, strips, foundation, rafts, pedestal and approach slabs of bridges etc. but excluding steel reinforcement and including centring and shuttering, laid in position, complete in all respects. (for work upto 1.5 Mtrs. below ground level). [HSR. 10.90 + 10.95 (a)].
Damp proof course 40 mm thick of cement concrete 1:2:4 using stone aggregate with 2 coats of bitumen 20/30 penetration at 1.65 Kg. per sqm. laid hot and sanded. (HSR 10.114)
Providing and laying 60mm thick ISI marked interlocking paver blocks conforming to IS 15658:2006/IRC:SP:63-2004of all Shapes and colour in design mix cement M-35 over a bed of 25 mm thick fine sand complete in all respect. (HSR 10.158) (Note:- Reputed make paver block only ISI marked will be used as approved by Engineer-in- Charge)
First class brick work laid in cement sand mortar 1:6 in foundation plinth. (HSR 11.2)
First class brick work laid in cement sand mortar 1:6 in 1st storey upto 4 metre above plinth level. (HSR 11.7) First Storey
Second Storey
THIRD Storey
Terracing consisting of tiles 22.86 cm x 11.43 Cm x 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and on other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc., (HSR 13.13). Second Storey
Corrugate G.I sheet roofing 0.80 mm thick fixed with galvanized iron ‘J’ or ‘L’ hooks, 10 mm dia G.I limpet and bitumen washers complete, excluding the cost of purlins,rafters and trusses. (HSR 13.18).
Ridges and valleys 45 cm overall in plain,G.I sheets 0.80 mm thick fixed with galvanised iron, J and L hooks 10 mm dia G.I. limpet and bitumen washers, complete. (HSR 13.23).
G.I sheet gutters, 0.80 mm thick 45 cm over all semi circular, including fixing with clamps and making connections with rain water pipes. (HSR 13.24).
Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16. (HSR 13.50)
Supplying & fixing in position G.I. pipe class 'B' spouts in chajjas and cantilevers. (e) 50mm i/d G.I. pipe. [HSR 13.55 (e)].
Bottom khurra on ground 1.2m x0.6m consisting of brick on edge laid in cment mortar 1:3 over 75mm c:c 1:8:16 including 12mm thick cement plaster 1:3. (HSR 13.57)
Cement Concrete 1:2:4 gola 10cm x 10cm quadrant along junction of roof with parapet wall finished smooth, where specified. (HSR 13.64).
Providing & Fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (a) 100 mm dia PVC pipe 6 kg. pressure.(Note- reputed Make PVC pipe such a Supreme, Finolex, Prince will be used as approved by Engieer-in-Charge [HSR 13.89] (a). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
Providing and fixing PVC Bend ISI Mark. (a) 100 mm dia PVC Bend. (Note:- Reputed make PVC Bend such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. [HSR 13.90]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k=0.052-0.057 w/m K, Fire Performance as per (BS 476 pt – 6 &7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33mm thick (galvanized @120 gsm) comprising of main T runners of 15x32mm of length 3000mm, cross T of size 15x32mm of length 1200mm and secondary intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600x600mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50mm long 8mm outer diameter M-6 dash fasteners, 6mm diameter fully threaded hanger rod up to 1000mm length and L-shape level adjuster of size 85x25x2mm, spaced at 1200mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size 24x24X3000mm made of 0.40mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-In-Charge. With or without groves (HSR 13.92)
Base course of floors consisting of 100mm thick cement concrete 1:8:16 and 100mm sand or stone filling. (HSR 14.1)
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. (HSR 14.4) Second Storey
Conglomerate floor 40mm thick Cement Concrete topping 1:2:4. (HSR 14.9)
Precast chequered tiles of 20mm thickness In ordinary grey cement without chips laid on 20mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps and landings.[HSR 14.45+Note]. First Storey
Kotah stone flooring 34 mm to 40 mm thick in any pattern as specified over 12 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing. (HSR 14.62) First Storey
SECOND Storey
Extra for nosing in treads of steps of Kotah stone slab. (HSR 14.65)
Kotah stone 20mm thick in skirting risers of steps, dados and wall facing (lining) and pillars laid on 12mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc. (HSR 14.66).Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storey
SECOND Storey
Parquet flooring 40mm thick consisting of first class well seasoned shisham wood in standard pattern laid in flooring consisting of bitumen applied hot, at the rate of 4.86 kg per dqm over 12 mm thick cement sand plaster 1:4 top surface rubbed smooth and wax polished to a fine finish. (HSR-14.70) GROUND FLOOR
Providing and fixing glass strips 5.5 mm thick in floors. (HSR 14.80)
12mm thick cement plaster on walls (1:6). (HSR 15.7). First Storey
Second Storey
THIRD Storey
15mm Thick Cement Plaster 1:6 on the rough side of single or half brick wall. (HSR 15.12). First Storey
Second Storey
THIRD Storey
10mm thick cement plaster 1:4 under side of ceiling. (HSR 15.52). First Storey
Second Storey
20mm thick cement plaster vertical damp proof coarse 1:3 with two coats of bitumen at 1.65 Kg. per sqm. Laid hot & sanded (HSR 15.77) (a) Vertical
Preparation of ply wood surface for painting inlcuding sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. Painting on wooden surfaces etc. (HSR 16.1) (Through rate)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge) (HSR 16.2). (Through rate)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.3). (Through rate)
Applying priming coat with metal primer on new steel or iron work including preparation of surface. Painting on mettalic Surfaces etc.(Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge) (HSR 16.9). (Through rate)
Painting two coats excluding priming coat with ready mixed paint for matelic sufraces in all shades on new steel or iron work.(Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge) (HSR 16.17). (Through rate)
White Washing (Three Coats) (Note:- First quality paint/ primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge)(HSR 16.48) (Through rate)
Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge) (HSR 16.58). (Through rate)
Providing two coats of exterior acrylic emulsion paint.(Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge) [HSR 16.79 (b)]. (Through rate)
Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (J.K./ Birla). (HSR 16.81) (Through rate)
Providing and fixing wooden handrail of required shape and desing, with necessary, screws, including labour for rounding, vertical and horizontal bends and curves complete fixed in position (b) commercial hard wood, such as hollock, champ, chikrassy and chaplash, etc (Non coniferous timber other than teak, conforming to I.S specification no. 1003, kiln seasoned) (HSR 17.69) (b)].
Providing and fixing helical door spring 150mm (superior quality), including necessary screws, complete- (b) iron. [HSR 17.79 (b)].
Supplying and fixing hydraulic door closer I.S.I mark, with necessary screws etc. complete (b) I.S.I designation no. II (size of door 701 mm to 850 mm) [HSR 17.82(b)].
Providing and fixing 50 mm cup board or ward robe knob- (b) aluminium. [HSR 17.84 (b)].
Providing and fixing 0.50 mm thick aluminium sheet, including cost of necessary screws, etc. complete. (HSR 17.87).
Factory manufactured panelled door or glazed windows shutters of commercial hard wood such as Hollock & Champ only. (non coniferous timber other teak, confirming to I.S. pecificationNo. 1003, Kiln seasoned) with 100mm wide vertical styles, 150mm wide lock rail 200mm wide bottom rail, and 100mm wide other rails, with panels of 15mm thick, tongued and grooved of commercial hard wood nd including cost of iron hinges, screw, chock/cleats, stops nails etc. complete in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position). (a) 30mm thick. [HSR 17.90 (a) - Note 1 under 17.18].
Factory manufactured wire gauze door and window shutters of commercial hard wood such as Hollock & Champ only. (non-coniferous timber other teak conforming to I.S. specification No. 1003, kiln seasoned) with 100mm wide vertical styles, 150mm wide lock rail 200 mm wide bottom rail, and wire gauze of 140 G or 120 G designation including cost of iron hinges, screws, chock/cleats, stops nails etc., complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position. (Styles and rails of windows shutter shall be 75 mm wide. (i) 30mm thick. [HSR 17.92 (i) - Note 1 under 17.18]
Factory manufactured Solid Flush Door Shutter, with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hotpressed, conforming to I.S. 2202 part I and II, fixed in position, including iron hinges, screws, chocks/cleats and stops etc., (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position. (Make: Duro, Green, Kitply). HSR 17.93 (a) - Note 1 under 17.18] (i) 35 mm thick.
Providing and fixing Aluminum work for doors, windows, ventilators and partitions, Structural Glazing with extruded built up standard tubular sections/appropriate Z. sections and other sections of approved make conforming to IS;733 and IS;1285 fixed with raw plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. aluminum sections shall be smooth, rust free straight mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling C.P brass/stainless steel screws. All complete.Fixed portion (Anodized Aluminum transparent or dyed to required shade according shade according to IS;1868, minimum anodic coating of grade AC 15). [HSR 17.95 + Note (i)]. Hindalco, Jindal make.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixed with rawel plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. Aluminium sections shall be smooth, rust free straight mitered and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/paneling C.P brass/stainless steel screws, etc. complete shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required including aluminium fitting. (HSR 17.96+Note (ii)].
Providing and fixing 12 mm thick preleminated paticle board flat pressed three layer or graded wood particle board conforming to IS;12823 grade I type II in paneling fixed in aluminium doors. Windows shutters and partition frames with c.p brass / stainlees steel screws etc. complete (b) Pre-laminated particle board with decorative lamination on both sides. [HSR 17.97 (b)].
Providing and fixing glazing aluminium door, windows ventilator shutter and partitions etc. with PVC/neoprene gasket etc. complete (cost of aluminium snap beading shall be paid in basis items.) (b) with float glass panes of 5.00 mm thickness. [HSR 17.98 (b)].
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS 6315 marked for door including cost of cutting floors as required embedding in floors and cover plates with brass pivot and single piece M.S sheet outer box. (a) with stainless steel cover plate. [HSR 17.99 (a)].
Providing aluminium Jali of thickness 7mm thick with openings 75mm x 75mm of including anodizing and fixing frame with cost of screws etc complete (HSR 17.100)
Providing fixing Aluminum round shape handic of cuter dia 100 mm with screws etc. complete. (I) Anodized (AC-15) Aluminum. [HSR 17.102 (i)].
Structural steel work in angles, tees and flats rivetted including cutting fixing all gusset plates, bolts, nuts, rivets, etc. with hoisting and erecting in position:- for roof trusses well kerbs, plates and trussed girders, etc., of any span for buildings and bridges. (HSR 18.3)
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12).
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including Straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights/depths /storeys/ basements etc. (Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement). (HSR 18.22).
Supplying and fixing Glass panes including special metal sash putty of approved make. (b) glass panes 4 mm thic, exceeding 40 sq. dm areas. [HSR 18.30 (b)].
Pressed steel sheet frames (chowkhats) consisting of 2mm thick steel sheet of the specified section, including iron lugs (hold fasts) iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red lead non-setting primer, of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs complete. [HSR 18.34]. (b) door and window frame Size of 76 mm x 38 mm with 35 mm wide single rebate.
(d) door and window frame size 114 mm X 50 mm with 35 mm wide double rebate.
Earth work non plastic with Tibba Sand under floors taken from outside of campus area with all lead and lift including loading, unloading, laid in 15 cm layer including ramming, watering, consolidating, compaction, and compensation of earth etc., complete in all respect as per the direction of engineer in charge. (For any lead and lift). [NS].
Providing and Laying Pre- polished Granite stone 17mm & above(colors like : S-white, steel grey, Tan Brown, Marigold, Crystal Blue, Rajasthan Black, Copper Silk) in flooring, laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite stone. (NS) First Storey
Note:- 1. In case of any difference in the unit & nomenclature of any of the HSR Items of Civil, P.H.work depicted in this DNIT and that given in HSR, the unit and nomenclature given in HSR shall be applicable. 2. Only reputed make material will be used (make/brand exhibited in HSR and exhibited in approved standard document) as approved by Engineer-in-charge, while executing various items/works at site.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .