Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-Finance | ₹15.6 L | L1 | Accepted-Finance L1 |
| 2 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-Document not submitted |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-Document not submitted |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-Document not submitted |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-Document not submitted |
Tender Value
₹24.8 L
EMD Value
₹75,000
Closing Date
7 Feb 2025, 2:00 pmClosed
EE RWD Dehradun
Tapovan Road nalapani chock near sweatdhara Raipur dehradun
Reconstruction work of Government Primary School Raidapur Dehradun under Block Sahaspur
2025_RES_79297_5
1734 dt 02-01-2025
Open Tender
Civil Works - Buildings
Item Rate
120 days
as per tender notice
As per tender notice
2 documents required · 2 mandatory
₹2,360
EE RWD DEHRADUN
₹75,000
15 Feb 2025
4 Jan 2025
7 Feb 2025
4 Jan 2025
7 Feb 2025
4 Jan 2025
Amount
Earth work in excavation by mechanical means (Hydraulic Excavat in foundation trenches or drains (not exceeding 1.5 m in width or 1 including dressing of sides and ramming of bottoms, lift upto 1.5 out the excavated soil and disposal of surplus excavated soil as dir of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size)
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in pth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 ( 1 cement : 6 coarse sand )
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shape and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, lintels, bands, plainwindow sills, staircases and spiral stair cases above plinth level up tofloor five level, excluding the cost of ing, ishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, sumers andcantilevers
Centring and shuttering including strutting,ropping etc. and removal of form Columns, Pillars, Piers, Abutments, Posts and truts
Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete - Fixed to steel windows by welding
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with L-Type section made of 1.60m M.S. Sheet, joints mitred and welded and grinded finish profi required size with 15x3mm lugs 10cm long embedded in ce concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse graded stone aggregate 20mm nominal size) or with wooden plugs screws or rawl plugs and screws or with fixing clips or with b nuts as required including fixing of necessary butt hinges and and applying a priming coat of approved steel primers.
12 mm cement plaster of mix in 1:6 (1 cement : 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
Making plinth protection 50mm thick of cement concrete 1:3: cement :3 coarse sand : 6graded stone aggregate 20mm no size) over 75mm bed by dry brick ballast 40mm nominal siz rammed and consolidated and grouted with fine sand includin finishing the top smooth.
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1 :4 (1 cement : 4 fine sand).
Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size)
Grading roof for water proofing treatment with22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone ggregate 20mm nominal size)
Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08%and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 ent : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting thejoints with white cement and matching ents etc., complete.Size of Tile 600x600 mm
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board truction withframe of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face eers on bothfaces of shutters: 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws
Providing and fixing aluminium sliding door bolts, ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 68), transparent or dyed to required colour or shade, with nuts and screwsetc. complete :
Providing and fixing aluminium handles, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868) parent or dyedto required colour or shade, with necessary screws etc. complete :9.100.1 125 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete :250x10 mm
Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm diameter
Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
Painting wood work with Deluxe Multi Surface Paint ofrequired shade. Two or more coat applied @ 0.90 ltr/10sqm over an under coat of er applied @0.75 ltr/10sqm of approved brand and manufacture
windows using galvanised M.S. wire gauge with average width of a in both directions with wire of dia. 0.63 mm. With 12 mm mild steel U beading.
Lettering with black Japan paint of approved brand and manufacture
Providing and laying matt finished vitrified tile of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
SARDAR DIMRI (BID ID -358326)
PRATAP SINGH (BID ID -357281)
SANJAY TOMER (BID ID -357126)
GAMBHIR SINGH TOMAR (BID ID -358770)
kwality construction (BID ID -358387)
RAVINDRA SINGH CHAUHAN (BID ID -358443)
SHAMSHER SINGH TOMAR (BID ID -358104)
M/S SANJAY MITTAL (BID ID -358026)
M/S NARAYAN DUTT SHARMA (BID ID -358004)
ARUN DOBHAL (BID ID -357856)
BHOPAL SINGH CHAUHAN (BID ID -358153)
LAXMAN SINGH (BID ID -358036)
KHAJAN SINGH (BID ID -358519)
KHAJAN SINGH (BID ID -358760)
SULTAN SINGH (BID ID -358161)
SUNIL PRASAD THAPLIYAL (BID ID -357259)
SATPAL SINGH CHAUHAN (BID ID -356832)
SURAT SINGH (BID ID -358241)
M/S MAHAVEER SINGH (BID ID -358772)
CHANDRA MOHAN SINGH TOMAR (BID ID -358043)
KHAJAN SINGH (BID ID -358405)
RAM SINGH (BID ID -358083)
SURAT RAM JOSHI (BID ID -358732)
stage.html
html • 0.16 MB
tech_eval.pdf
fin_eval.pdf
finance_94603.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .