| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC AWANTA BHAWAN SOURA SRINAGAR 190011 J K | SRINAGAR | JAMMU AND KASHMIR | 190011 | ₹1.1 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.4 Cr+₹29.6 L (27.6%)Rejected-AOC | ₹1.4 Cr+₹29.6 L (27.6%) | L2 | Rejected-AOC Other than lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Admitted |
Tender Value
₹1.6 Cr
EMD Value
₹2.4 L
Closing Date
28 Apr 2020, 6:00 pmClosed
CE 31 Zone
CE 31 Zone Srinagar
Outsourcing of services for maintenance and operation of E M installation under GE 874 EWS
2020_MES_324048_1
Outsourcing of maint operatoion under GE 874 EWS
Open Tender
Manpower Supply
Item Rate
335 days
Kupwara
Class B Cat d v
9 documents required · 9 mandatory
₹1,000
Yes
GE 874 EWS
₹2.4 L
Yes
18 Jun 2020
29 Feb 2020
30 Apr 2020
29 Feb 2020
28 Apr 2020
21 Mar 2020
29 Feb 2020 - 14 Mar 2020
Amount
Manning and Operation of water supply installations at MES Complex at Zangli including its day to day maintenance in three shifts per day each shift of 08 hrs (round the clock) including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated at Zangli. (a) Transformer step down 11/440 volt, outdoor type -06 Nos. (b) Pump set 60 HP - 03 Nos. (c) Pump set 20 HP - 02 Nos. (d) Pump set 7.5 HP - 02 Nos. (e) Water filteration plant - 02 Nos. (f) Sedimentation tank - 01 No. (g) LT Panel board - 03 Nos. (h) DG Set 125 KVA- 03 Nos. (j) DG Set 100 KVA - 01 No. (k) Servo voltage stabilizer- 05 Nos. Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- FGM. (b) Shift (ii) 1600 hrs to 2400 hrs- FGM. (c) Shift (iii) 2400 hrs to 0800 hrs- FGM.
Manning and Operation of diesel engine set installations at signal centre at signal centre including its day to day maintenance in three shifts per day each shift of 08 hrs (round the clock) including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated at Zangli. (a) Operation of DG Set capacity 82.5 KVA -02 Nos. (b) GOD horizontal 400 Amp - 02 Nos (c) Voltage stabilizer capacity 100 KVA - 02 Nos. (d) LT Panel - 03 Nos. Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- FGM. (b) Shift (ii) 1600 hrs to 2400 hrs- FGM. (c) Shift (iii) 2400 hrs to 0800 hrs- FGM.
Manning and Operation of CHS installation at Div HQ and Field Hospital at Zangli for two shift per day, each shift consisting of 08 hours per day, including sundays and holidays during wi ter months and servicing of ACs, Refrigerators and other electronices under Zangli military station for one shift of 08 hours per day, including sundays and holidays during summer months, by employing technicallyqualified team/resources with help of one mate FGMsper shift for entire comprising of following & maintaning daily log sheets, complete all as specified and as directed by engineer in charge. The following equiptments to be maintained and operated: (a) Operation and maintenance of CHS Furnaces - 03 Nos (b) CHS circuit maintenance and routine operations. (c) FCUs routine maintenance and repairs. (d) Operation and maintenance of 35 KVA DG set. (e) Maintenance of ACs, Refrigerators, Geysers and other electronics (during summer months only) Note :- Shift timing for operation of CHS will be as per dirns from Div HQ from time to time. The dates for changeover from summer to winter and viceversa will be a decided by engineer in charge.
Manning and Operation of HT 11 KV receiving station installation at Drugmulla including its day to day maintenance in three shifts per day each shift of 08 hrs (round the clock) including Sunday and holidays by employing two electricians and one FGM per shift for entire system & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) HT 11 KV VCB (incoming) - 01 No. (b) HT 11 KV VCB (outgoing) - 03 Nos. (c) LT Control Panel board - 01 No. (d) Voltage stablizer 100 KVA - 04 Nos. (e) Transformer 100 KVA - 04 Nos. (f) HT/LT network in the Drugmulla Grn and incoming HT overhead line from Kupwara to Drugmulla Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- Electrician. (b) Shift (ii) 1600 hrs to 2400 hrs- Electrician. (c) Shift (iii) 2400 hrs to 0800 hrs- FGM.
Manning and Operation of HT/LT line, pumps, transformers and internal points at each installations at 628 EME Bn Drugmulla including its day to day maintenance in one shift per day each shift of 08 hrs including Sunday and holidays by employing one Mate FGM per shift for entire system & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 125 KVA - 01 No. (b) LT control panel with accesories - 02 Nos. (c) Centrifugal pump set 7.5 HP - 01 Nos (d) Centrifugal pump set 40 HP - 01 Nos (e) Submersible pump set 5 HP - 02 Nos Note :- Shift timing 1600 hrs to 2400 hrs- Mate FGM
Manning and Operation of HT 11 KV receiving station installation at Chakkigam including its day to day maintenance in three shifts per day each shift of 08 hrs (round the clock) including Sunday and holidays by employing two electricians and one Electrician per shift for entire system & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) Transformer 250 KVA -01 No. (b) Voltage stabilizer 250 KVA - 01 No. (c) LT control panel board - 01 No. (d) HT 11 KV VCB - 01 No. (e) Complaint cell. (f) Incoming HT overhead line from Drugmulla to Chakkigam. (g) Pumping installations. (h) DG sets -07 Nos Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- Electrician. (b) Shift (ii) 1600 hrs to 2400 hrs- Electrician. (c) Shift (iii) 2400 hrs to 0800 hrs- Electrician.
Manning and Operation of E/M installations and DG Set at 28 Arty Bde, Drugmulla including its day to day maintenance in one shift per day each shift of 08 hrs including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 82.5 KVA -01 No. (b) DG Set 63 KVA - 01 No. (c) LT control panel of DG Set with accessories - 02 Nos. Note :- Shift timing is as following (a) Shift (i) 800 hrs to 1600 hrs- FGM. (b) Shift (ii) 1600 hrs to 2400 hrs- FGM.
Manning and Operation of E/M pumping installations at pump house Chakkigam including its day to day maintenance in one shift per day each shift of 08 hrs including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 200 KVA -01 No. (b) DG Set 100 KVA - 02 Nos. (c) DG Set 50 KVA - 01 No. (d) DG Set 32.5 KVA - 02 Nos. (e) Centrifugfal pump set 20 HP - 02 Nos. (f) LT control panel of DG Set with accessories - 06 Nos Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- FGM. (b) Shift (ii) 1600 hrs to 2400 hrs- FGM.
Manning and Operation of E/M installations and DG Set at Ascon node Trehgam including its day to day maintenance in three shifts per day each shift of 08 hrs (round the clock) including Sunday and holidays by employing one FGM per shift for entire system & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) Transformer 160 KVA - 04 Nos. (b) LT Control Panel board - 04 Nos (c) Voltage stablizer 150 KVA - 01 No (d) Voltage stablizer 100 KVA - 02 No (e) HT/LT network in the Trehgam Grn and incoming HT overhead line from Kupwara to Trehgam Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- FGM. (b) Shift (ii) 1600 hrs to 2400 hrs- FGM. (c) Shift (iii) 2400 hrs to 0800 hrs- FGM.
Manning and Operation of water supply installation at water point at 68 Bde Trehgam including its day to day maintenance in two shift per day each shift of 08 hrs including Sunday and holidays by employing one Mate FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 50 KVA - 01 No. (b) Centrifugal pump set 30 HP - 01 No. (c) Centrifugal pump set 20 HP - 02 Nos. (d) LT Panel with accessories - 02 Nos. (e) Sluice valve of different sizes - 03 Nos. Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- Mate FGM. (b) Shift (ii) 1600 hrs to 2400 hrs- Mate FGM.
Manning and Operation of HT/LT line, pumps, transformers and internal points at each installations at pump house Signal centre Trehgam including its day to day maintenance in one shift per day each shift of 08 hrs including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 125 KVA - 01 No. (b) LT control panel with accesories - 02 Nos (c) Centrifugal pump set 7.5 HP - 01 No (d) Centrifugal pump set 40 HP - 01 No (e) Submersible pump set 5 HP - 02 Nos Note :- Shift timing 800 hrs to 1600 hrs- FGM
Manning and Operation of HT/LT line, pumps, transformers and internal points at each installations at pump house Bde Security light Trehgam including its day to day maintenance in one two per day each shift of 08 hrs including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 125 KVA - 01 No. (b) LT control panel with accesories - 02 Nos (c) Centrifugal pump set 7.5 HP - 01 No. (d) Centrifugal pump set 40 HP - 01 No. (e) Submersible pump set 5 HP - 02 Nos Note :- Shift timing are as following (a) Shift (i) 0800 hr sto 1400 hrs- FGM. (b) Shift (ii) 1400 hrs to 2200 hrs- FGM.
Manning and Operation of HT 11 KV receving station installation at Niyari including its day to day maintenance in three shifts per day each shift of 08 hrs (round the clock) including Sunday and holidays by employing one electrician per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) HT 11 KV 400Amp VCB (incoming) -01 No. (b) HT 11 KV 400 Amp OCB (outgoing) - 03 Nos (c) Battery bank 24 Volts - 02 Nos, 12 Volts each and battery charger. (d) Transformer indoor type 11 KV/ 433 Volts 250 KVA - 01 No. (e) Transformer outdoor type 11 KV/ 433 Volts 250 KVA - 01 No (f) LT Panel with accessories - 02 Nos. (g) Voltage stablizer 3 phase, 415 volts, 75 KVA - 01 No (h) HT/LT overhead lines/UG Cables within Niyari Grn and from take over point to Panzgam Grn Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- Electrician. (b) Shift (ii) 1600 hrs to 2400 hrs- Electrician. (c) Shift (iii) 2400 hrs to 0800 hrs- Electrician.
Manning and Operation of 11 KV Sub stn at Chowkibal including its day to day maintenance in three shifts per day each shift of 08 hrs (round the clock) including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed at P/H Chowkibal. The following equipments to be maintained and operated. (a) HT 11 KV 400 Amp OCB - 01 No. (b) Transformer indoor type 11 KV/ 433 Volts 150 KVA - 01 No (c) Transformer outdoor type 11 KV/ 433 Volts 160 KVA - 01 No (d) LT Panel with accessories - 04 Nos. (e) Voltage stablizer 3 phase, 415 volts, 100 KVA - 01 No. (f) HT/LT overhead lines/UG Cables within Chowkibal/ Panzgam Grn and from Panzgam Grn to Chowkibal Grn Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- FGM. (b) Shift (ii) 1600 hrs to 2400 hrs- FGM. (c) Shift (iii) 2400 hrs to 0800 hrs- FGM.
Manning and Operation of Diesel engine set installations at signal centre at Chowkibal Military Station including its day to day maintenance in one shift per day each shift of 08 hrs (round the clock) including Sunday and holidays by employing technically qualified team/ ressources with help of one Mate FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equpments to be maintained and operated: (a) Operation of DG sets capacity - One 62.5KVA, one 125 KVA , one 63 KVA and one 15 KVA (b) AMF panel of DG sets. (c) LT Panels -03 Nos Note :- Shift timinng is as following (a) Shift(i) 0800 hrs to 1600 hrs- Mate FGM
Manning and Operation of Diesel engine set installations at signal centre at Chowkibal Military Station including its day to day maintenance in two shifts per day each shift of 08 hrs (round the clock) including Sunday and holidays by employing technically qualified team/ ressources with help of one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equpments to be maintained and operated: (a) Operation of DG sets capacity - One 62.5KVA, one 125 KVA , one 63 KVA and one 15 KVA (b) AMF panel of DG sets. (c) LT Panels -03 Nos Note :- Shift timinng is as following (a) Shift(i) 0600 hrs to 1400 hrs- FGM (b) Shift(ii) 1400 hrs to 2200 hrs- FGM
Manning and Operation of HT/LT Line incl pumps located at P/H Panzgam including its day to day maintenance in two shift per day each shift of 08 hrs including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG set 15 KVA -01 No. (b) Sumbersible Pump set 5 HP - 01 No (c) Voltage stabilizer 3 phase 415 volts of cap 100 KVA - 01 No. (d) Chlorination of water either manually or by chlorination plant- 01 No (e) LT panel with acessories - 01 Nos. Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- FGM. (b) Shift (ii) 1600 hrs to 2400 hrs- FGM.
Manning and Operation of HT 11 KV receving station installation and DG Set at Signal centre Tangdhar including its day to day maintenance in three shifts per day each shift of 08 hrs (round the clock) including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 125 KVA - 02 Nos. (b) LT control panel board different capacity - 03 Nos. (c) HT 11 KV 400 Amps VCB (incoming) - 01 Nos. (d) Automatic Voltage stablizer 250 KVA - 01 No. (e) HT 11 KV 400 Amps VCB (outgoing) - 02 Nos (f) Outdoor transformer 250 KVA - 01 Nos Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- FGM. (b) Shift (ii) 1600 hrs to 2400 hrs- FGM. (c) Shift (iii) 2400 hrs to 0800 hrs- FGM.
Manning and Operation of 11 KV sub stn Chamkot including its day to day maintenance in one shift per day each shift of 08 hrs including Sunday and holidays by employing one Electrician per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 125 KVA - 01 No. (b) LT control panel board - 01 No. (c) Outdoor transformer 100 KVA - 02 No. Note :- Shift timing 0800 hrs to 1600 hrs- Electrician.
Manning and Operation of 11 KV Sub stn Baghbella including its day to day maintenance in one shift per day each shift of 08 hrs including Sunday and holidays by employing one Electrician per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 125 KVA -01 No. (b) LT control panel board - 01 No. (c) Outdoor transformer 100 KVA - 02 No. Note :- Shift timing 0800 hrs to 1600 hrs- Electrician.
Manning and Operation of security light DG Set at 6 Garh Riff including its day to day maintenance in one shift per day each shift of 08 hrs including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 125 KVA -01 No. (b) LT control panel board - 01 No. Note :- Shift timing 1600 hrs to 2400 hrs- FGM
Outsourcing of service for operation and maintenance of Water Lines in all Military Locations of Tangdhar incl Chlorination and filteration and its day to day maintenance in two shift per day, each shift of 08 hours, including sundays and holidays, by employing technically qualifed team/resources comprising of one FGM per shift of 8 hrs for entire system comprising of following & maintaining daily log sheets, complete all as specified and as directed Main water Point Nachain. The following equipments to be maintained and operated. (a) Transformer indoor type 11KV/440 Volte 63 KVA-01 No (b) Sluice valve 150 mm dia -04 Nos (c) Chlornation of water either manually or chlorination plant-01 No (d) LT Panel with accessories-01 Nos Note :Shift timings are as following :- (a) Shift (I) 0800 hrs to 1600hrs - FGM (b) Shift(II) 1600 hrs to 2400hrs- FGM
Manning and Operation of Line including pumps located at Main water point Nachian including its day to day maintenance in two shift per day each shift of 08 hrs including Sunday and holidays by employing one Mate FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) Transformer indoor type 11 KV/ 433 Volts 63 KVA - 01 No. (b) Sluice Valve 150 mm Dia -04 Nos. (c) Chlorination of water either manually or chlorination plant- 01 No. (d) LT panel with acessories - 01 Nos Note :- Shift timing are as following (a) Shift (i) 0600 hrs to 1400 hrs- Mate FGM. (b) Shift (ii) 1400 hrs to 2200 hrs- Mate FGM.
Manning and Operation of E/M installations and DG Set at 109 Inf Bde Dawar including its day to day maintenance in three shifts per day each shift of 08 hrs (round the clock) including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 250 KVA - 02 No. (b) DG Set 63 KVA - 01 No. (c) LT control panel board for DG Set - 01 Nos. Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- FGM. (b) Shift (ii) 1600 hrs to 2400 hrs- FGM. (c) Shift (iii) 2400 hrs to 0800 hrs- FGM.
Manning and Operation of E/M installations and DG Set at 109 Inf Bde Dawar including its day to day maintenance in one shift per day each shift of 08 hrs (round the clock) including Sunday and holidays by employing one Mate FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 250 KVA - 01 No. (b) DG Set 63 KVA - 01 No. (c) LT control panel board for DG Set - 01 Nos. Note :- Shift timing are as following (a) Shift (i) 0800 hrs to 1600 hrs- Mate FGM.
Manning and Operation of E/M installations and DG Set at 13 Grenadiers Dawar including its day to day maintenance in one shift per day each shift of 08 hrs including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 150 KVA- 01 Nos. (b) LT control panel board for 125 KVA capacity DG Set - 01 No. (c) Repair and maintenance of Internal Wiring,Street Lights in complete garrison. (d) Repair and maintenance of ACs,Geysers, Refrigerators and other electrical appliances. Note :-Shifts timing are as following :- (a) Shift (II) 0800 hrs to 1600 hrs- FGM
Manning and Operation of E/M installations and DG Sets located at various locations in bandipora including its day to day maintenance in one shift per day each shift of 08 hrs including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 50 KVA - 01 No. (Bandipur) (b) Voltage stabilizer capacity 50 KVA - 01 No. (c) Pump sets 20 HP - 02 Nos. (d) Diesel engine driven pump set of 28 BHP - 01 No. (e) LT control panel board for regulating of electric supply from SED/DG Set - 04 Nos Note :- Shift timing 0800 hrs to 1600 hrs- FGM
Manning and Operation of E/M pumping installation and DG Sets located at various locations in Bandipora det including its day to day maintenance in one shift per day each shift of 08 hrs including Sunday and holidays by employing one FGM per shift for entire system comprising of following & maintaining the daily log sheets complete all as specified and as directed. The following equipments to be maintained and operated. (a) DG Set 50 KVA - 01 No. (b) Voltage stabilizer capacity 50 KVA - 01 No. (c) Pump sets 20 HP - 02 Nos. (d) Diesel engine driven pump set of 28 BHP - 01 No. (e) LT control panel board for regulating of electric supply from SED/DG Set - 04 Nos Note :- Shift timing 0800 hrs to 1600 hrs- FGM
Notes :- (a) Rectification of faults in the HT/LT system in the installation will be the responsibility of the contractors. (b) The T&P required to carried out the above wk will be provided by the contractor and will be dumped at site. All store/accessories issued by MES for day to day maint must be returned in original conditions. (c) The safety precautions of the operator will be the responssibility of the contractor and the unit rate is demand to be incl for the safety eqpts and T&P. (d) The general cleanliness of the plants and and eqpts inthe installation and the area in and around the installation is the responsiibility of the contractoror and all chemicals and equipment for the same will be provided by the contractor. (e) Staff deployed must posses mobile phones without camera, standalone camera and police verification certificate at all times. (f) Elect/FGM/Helper shall be deputed in other areas GE 874 EWS for working as directed by JE E/M, AGE E/M and GE if necessary. (g) Elect/FGM/Helper deployed must posses ITI certificate and three years of experience issued by competent firm/authority. (h) The Contractor has to provide reliver and the cost of the same deemed to be included. (j) Rectification of minor faults in the Generator systems is the responsibility of the contractor.
(k) The Contractor has to provided Adhar linked bank statement of the manpower deployed at each installation and a written confirmation (with thump imprint) from each of the staff showing the payment made before producing RAR to Engr-in-Charge. (l) The Contractor has to provided approved colour coded of uniform for manpower deployed at each installation as specified by Engr-in-Charge. (m) The contractor must pay salary to all deployed tradesmen as per policy of the Office of labour commision Govt of India/J&K Govt, whichever is higher. All regulations of Indian Labour Law, Minimum wages act of India, Payment of Bonus Act of India, Central EPF regulations and contracts Act must be followed irrespective of any State Court's order against the same. (n) All Electricians and FGMs will be considered as Skilled and Mate FGMs as Semi Skilled Industrial workers.
M/S Noor Mohammad Shalla
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .