Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.9 L+₹2.7 L (9.94%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L2 | Rejected-Finance L2 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
18 Aug 2020, 6:00 pmClosed
GE (AF) JAMNAGAR NO.1
GARRISON ENGG (AF) NO.1 Military Engineer Service Air Force Station No.1 jamnagar
REPAIR/MAINTENANCE OF EXTERNAL WATER SUPPLY, SUBMERSIBLE PUMP SETS ETC. AND OTHER MISCELLENEOUS WORKS AT AFS SAMANA
2020_MES_355422_3
8734/E8
Open Tender
Civil Works
Item Rate
270 days
SAMANA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AIRFORCE JAMNAGAR NO.1
₹60,000
Yes
26 Sept 2020
10 Aug 2020
19 Aug 2020
10 Aug 2020
18 Aug 2020
10 Aug 2020
Amount
Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth for laying pipe line etc not exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft / loose soil omplete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick using suitable excavated soft / loose soil omplete all as specified and as directed by Engineer-in-Charge.
Removing excavated soil to a distance n exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point.
Supply and fix in repair / laid in trenches 25 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair / laid in trenches 40 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair / laid in trenches 50 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair / laid in trenches 80 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair/ laid in trenches 100 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair on wall or laid on floor 25 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair on wall or laid on floor 15 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.
S & F in repair 15 mm size bib tap PTMT , fancy type, screwed down, high pressure with capstan head, screwed for iron pipe or for union omplete all as specified and as directed by Engineer-in-Charge. Make :- Prayag Cat No 121F or equivalent of makes listed in PS Appx 'B'
Supply and fix in repair on wall or laid on floor 20 mm bore galvanised steel water tubing, light grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 25mm bore 3-layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. including taking down old pipe omplete all as specified and as directed by Engineer-in-Charge.
S&F in repair 32mm bore 3-layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair PP-R gate valve (brass insert) of size 25 mm bore as per requirement at site complete including taking down unserviceable complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair PP-R gate valve (brass insert) of size 32 mm bore as per requirement at site complete including taking down unserviceable complete all as specified and as directed by Engineer-in-Charge.
Supply & fix in repair HDPE pipe of outer dia 50 mm confirming to IS - 4984, ISI marked, working pressure PE-63, PN-10 rating, including jointing material, clamps and nut bolts washers. etc, laid in trenches or fixed on wall all as specified and directed by Engr In charge.
Supply & fix in repair HDPE pipe of outer dia 80 mm confirming to IS - 4984, ISI marked, working pressure PE-63, PN-10 rating, including jointing material, clamps and nut bolts washers. etc, laid in trenches or fixed on wall all as specified and directed by Engr In charge.
Supply & fix in repair HDPE pipe of outer dia 100 mm confirming to IS - 4984, ISI marked, working pressure PE-63, PN-10 rating, including jointing material, clamps and nut bolts washers. etc, laid in trenches or fixed on wall all as specified and directed by Engr In charge.
Supply & fix in repair HDPE pipe of outer dia 150 mm confirming to IS - 4984, ISI marked, working pressure PE-63, PN-10 rating, including jointing material, clamps and nut bolts washers. etc, laid in trenches or fixed on wall all as specified and directed by Engr In charge.
Supply & fix in repair HDPE pipe of outer dia 180 mm confirming to IS - 4984, ISI marked, working pressure PE-63, PN-10 rating, including jointing material, clamps and nut bolts washers. etc, laid in trenches or fixed on wall all as specified and directed by Engr In charge.
S&F in repair 25 mm size gun metal gate valves ISI marked with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 40 mm size gun metal gate valves ISI marked with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 50 mm size gun metal gate valves ISI marked with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair 80 mm size cast iron sluice valve, long body type of pressure rating PN-1.6 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 including taking down old valve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair 100 mm size cast iron sluice valve, long body type of pressure rating PN-1.6 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 including taking down old valve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair 150 mm size cast iron sluice valve, long body type of pressure rating PN-1.6 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 including taking down old valve complete.
Supply and fix in repair Automatic starter in SS enclosure suitable for single phase submersible motor of capacity 2 HP with complete connection.
Material and labour for Rewinding of monoblock centrifugal pump set 1 HP capacity of booster pump by cutting down and removing existing burnt out copper winding ,cleaning of slots and rewinding with super enamelled solid copper conductor (winding wire) complete including varnishing, drying, opening and fixing in the same position ,and testing of motor complete all as specified and as directed by Engineer-in-Charge.
Taking out submersible pump set of any capacity from the tube well lowered at the depth of 130 mtrs from the ground level along with taking out GI / HDPE Pipes & 2 run of flat submersible cable after disconnecting electrical and outlet connection , lowering the same pump after repairing / servicing along with HDPE Pipe and electric cable including fixing of cable to pipe with PVC strip , replacement of clamps and mild steel bolts, nuts and washers, casing caping bell cap etc, connecting electrical connection and delivery pipe line complete all as specified and as directed by Engineer-in-Charge.
Note: (i) Repair/servicing of submersible pump & motor will be measured and paid separately under this schedule.
M&L for repairing / servicing/rewinding of 17.5 HP capacity submersible motor multistage by dismantling the pump ,replacing the worn out bearings 02 Nos.,Bush 01 No., Stage bushing 01 No. Sleeves 01 No. Oil Sleeve 01 No.,Non Return Valve 01 No., Stainless steel filter cage 01 No. etc and malting of pump shaft including grinding and polishing ,reassembling the pump and testing complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Rewinding of open well nonclog submersible pump set of capacity range 20-30 HP by cutting down and removing existing burnt out copper winding ,cleaning of slots and rewinding with super enamelled solid copper conductor (winding wire) complete including varnishing, drying, ovening and fixing in the same position ,and testing of motor complete all as specified and as directed by Engineer-in-Charge.
Material and labour for dismantling of existing monoblock submersible pump set of capacity 10 HP from dismantling the pump ,rewinding,replacing the worn out bearings 02 Nos.,Bush 01 No., Stage bushing 01 No. Sleeves 01 No. Oil Sleeve 01 No. etc and matling of pump shaft including grinding and polishing ,reassembling the pump and testing complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Rewinding of monoblock centrifugal pump set 5 HP capacity by cutting down and removing existing burnt out copper winding ,cleaning of slots and rewinding with super enamelled solid copper conductor (winding wire) complete including varnishing, drying, ovening and fixing in the same position ,and testing of motor complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Rewinding of monoblock centrifugal pump set 20 HP capacity by cutting down and removing existing burnt out copper winding ,cleaning of slots and rewinding with super enamelled solid copper conductor (winding wire) complete including varnishing, drying, ovening and fixing in the same position ,and testing of motor complete all as specified and as directed by Engineer-in-Charge.
Supply and fix submersible pump cable flat , PVC insulated, PVC sheathed, multistranded copper conductor of size 10 Sqmm 3 core 1100 volt grade & connecting complete including taking down unserviceable cables complete all as specified and as directed by Engineer-in-Charge.
M&L for Cleaning of overhead water tank of capacity 5,000 Gallons by removing sludge, mud or any other foreign material from the bottom and internal surface of tank by wire brushing, cleaning with fresh water, bailing out complete water with pump sets, washing of internal surface with sufficient quantity of........
.........water & bleaching powder (0.10 Kg of bleaching powder will be mix in 1 litre water), finally applying two coats of lime washing on entire internal surface, writing the date of cleaning and capacity of tank with white synthetic enamel paint on black background with synthetic enamel paint complete all as directed by Engineer-in-charge.
M&L for Cleaning of Static water tank of capacity 10,000 Gallons by removing sludge, mud or any other foreign material from the bottom and internal surface of tank by wire brushing, cleaning with fresh water, bailing out complete water with pump sets, washing of internal surface with sufficient quantity of water & bleaching powder (0.10 Kg of bleaching powder will be mix in 1 litre water), finally applying two coats of lime washing on entire internal surface, writing the date of cleaning and capacity of tank with white synthetic enamel paint on black background with synthetic enamel paint complete all as directed by Engineer-in-charge.
M&L for Cleaning of Static water tank of capacity 1,00,000 Gallons by removing sludge, mud or any other foreign material from the bottom and internal surface of tank by wire brushing, cleaning with fresh water, bailing out complete water with pump sets, washing of internal surface with sufficient quantity of water & bleaching powder (0.10 Kg of bleaching powder will be mix in 1 litre water), finally applying two coats of lime washing on entire internal surface, writing the date of cleaning and capacity of tank with white synthetic enamel paint on black background with synthetic enamel paint complete all as directed by Engineer-in-charge.
Supply and installation, testing, commissioning of factory made, CPRI approved, outdoor type, LT Panel board, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete all as specified and directed & Consisting of the following equipment's:-
(a) Aluminium bus bar of capacity 300 Amps for Phase and 150 Amps for Neutral - 01 set (b) Incoming MCCB 200 Amps, Breaking capacity 25 kA, 4 Pole, - 01 No (c) Outgoing MCCB 63Amps, Breaking capacity 16 kA, 3 Pole, - 02 Nos (d) Outgoing MCCB 100 Amps, Breaking capacity 16 kA, 3 Pole, - 01 Nos (e) Automatic star delta starter suitable for 25 HP Motor relay range up to 60 Amps - 01Nos.(Including Single phase preventer etc.)
(g) Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing (Make HPL , Cat Part No NEMFVIFPPE000 or equivalent of Make : L & T / Secure / Conserve.) (h) Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability-01Set.
Note :- Quoted rates shall be deemed to include for grouting / fixing of bus bar chamber in PCC 1:3:6 type C2 and PCC block masonry with PCC block of mix 1:5:8 & plastering 10mm thick in CM 1:6 complete all as specified and directed by Engg-in-Charge
Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, LT Panel board, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete all as specified and directed & Consisting of the following equipment's:-
(a) Aluminium bus bar of capacity 160 Amps for Phase and 80 Amps for Neutral - 01 set (b) Incoming MCCB 80 Amps, Breaking capacity 25 kA, 4 Pole, - 01 No (c) Outgoing MCCB 63Amps, Breaking capacity 16 kA, 4 Pole, - 01 Nos (d) Outgoing MCCB 32 Amps, Breaking capacity 16 kA, 4 Pole, - 03 Nos
(g) Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing (Make HPL , Cat Part No NEMFVIFPPE000 or equivalent of Make : L & T / Secure / Conserve.) (h) Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability-01Set.
Note :- Quoted rates shall be deemed to include for grouting / fixing of bus bar chamber in PCC 1:3:6 type C2 and PCC block masonry with PCC block of mix 1:5:8 & plastering 10mm thick in CM 1:6 complete all as specified and directed by Engg-in-Charge
Periodical Preventive maintenance / servicing of solar water heater, glass tube collector / Flat plate collector system , storage type with electrical backup of capacity 100 - 500 litres, as per manufacturer instruction comprising of the following works at different locations at 77SU AFS Samana.
(a) Complete cleaning of solar system, removing of dirt dust etc. (b) Cleaning of heating surface glass with glass cleaning solution. (c) Opening of cold & hot water connection draining out deposited water removing of mud turbidity etc & cleaning with fresh water. (d) Checking of Non return valve, Electrical backup system & sacrificial anode & tighten the connection. (e) Checking of glass holding tube joint & rectification of leakage. (f) Replacement of unserviceable spare part.
Note:- (i) Preventive maintenance shall be carried out 2 times in a year (at the interval of 6 months approx) & shall be measured as one unit for payment. (ii) Unserviceable spares parts will be measured & paid separately as supply only. (iii) Work shall be executed through Authorised service technician of Tata Solar BP / Delta. (iv) Contractor shall submit the documentary evidence of Authorised service technician for the approval of GE before commencement of work. (v) Contractor shall submit certificate for every month, to Engineer-in-Charge, obtain from Authorised service centre that work has been executed by them. (vi) Above said certificate shall be endorsed by Engineer-In-Charge.
(a) 100 Ltrs capacity
(b) 200 Ltrs capacity
(c) 500 Ltrs capacity
S&F in repair solar glass tube suitable for glass tube collector type solar water heater.
S&F in repair Sacrificial Anode suitable for glass tube collector type solar water heater.
Supply & fix in repair Electrical backup of capacity 1.5/2 KW, 230 V supply,including with thermosatate and relay suitable for glass tube/Plate collector type solar water heater. Sample is provided by the AGE (B&R) office.
S&F in repair "O" ring glass tube type suitable for glass tube collector type solar water heater.
S&F repair only Collector rubber gasket suitable for glass tube collector type solar water heater.
M&L for Chemical cleaning of solar water tank by providing chemical & removing all scale / dirt / dust etc as per manufacturer's instruction complete all as specified and as directed by Engineer-in-Charge.
S&F in repair hot water supply hose along with its two numbers round clip for connecting water supply from Solar water heater panel to its storage tank.
S&F in repair solar water heater storage tank only of capacity 100 LPD and fixed in its position along with removal of old one and connecting with its inlet and outlet pipe of solar heating panel complete all as specified and as directed by Engineer-in-Charge.
S&F in repair solar water heater storage tank only of capacity 200 LPD and fixed in its position along with removal of old one and connecting with its inlet and outlet pipe of solar heating panel complete all as specified and as directed by Engineer-in-Charge.
Deployment of man power for Collecting the sample of water from different point such as under ground sump , over head tank , open well, bore well and testing of water from reputed Govt laboratory for iron contain, PH value, Hardness, turbidity, chloride, fluoride and submitting the test report to Engineer-in-Charge. Note :- Testing of water shall be carried out two times during currency of contract with interval of 6 month (approx.) one time testing shall be measured as one Unit (Each Job) for payment.
Deployment of man power for Collecting the sample of water from different point such as under ground sump , over head tank , open well, bore well and testing of water from reputed Govt laboratory for bacteriological test including arsenic test and submitting the test report to Engineer-in-Charge. Note :- Testing of water shall be carried out every 6 months during currency of contract and one time testing shall be measured as one Unit (Each Job) for payment.
Surface cleaning / dressing by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, pruning of small branches of tree, weeds in soft loose soil all as specified and directed by Engineer- in-charge. Note:- This item shall be executed for cleaning of surrounding area of various E&M installation.
M&L for dismantling, taking out choke up radiator assembly, of 25 KVA DG Set, de-scaling, cleaning of fan and cooling coil fins including soldering / brazing at the leakage point re-fixing radiator assembly after repair complete all as specified and as directed by Engineer-in-Charge.
M&L for dismantling, taking out choke up radiator assembly, of 50 KVA DG Set, de-scaling, cleaning of fan and cooling coil fins including soldering / brazing at the leakage point re-fixing radiator assembly after repair complete all as specified and as directed by Engineer-in-Charge.
M&L for dismantling, taking out choke up radiator assembly, of 63 KVA DG Set, de-scaling, cleaning of fan and cooling coil fins including soldering / brazing at the leakage point re-fixing radiator assembly after repair complete all as specified and as directed by Engineer-in-Charge.
M&L for taking out self starter of 12 / 24 volts DC from DG set, servicing of starter including replacement of clutch plate, moving control pinion, spring etc, fixed in same position complete all as specified & directed by Engineer-in Charge.
Service Charges for Carrying out the 'B' Check maintenance of DG set of 25 KVA capacity of make Greaves, from authorized service representative from the manufacturer of DG set, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters, checking inlet & Exhaust manifold cap screws, checking of fan hub & water pump, including supply & fix in repair of following spares :-
(a) Kit, fuel filter and ring - 2 Kit
(b)Element for Lubrication oil filter - 2 Nos.
(c) Kit, Element of super bypass filter - 01 Kit
(d) Seal, O Ring - 02 Nos
Service Charges for Carrying out the 'B' Check maintenance of DG set of 50 KVA capacity of make Greaves, from authorized service representative from the manufacturer of DG set, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters, checking inlet & Exhaust manifold cap screws, checking of fan hub & water pump, including supply & fix in repair of following spares :-
(a) Kit, fuel filter and ring - 2 Kit
(b)Element for Lubrication oil filter - 2 Nos.
(c) Kit, Element of super bypass filter - 01 Kit
(d) Seal, O Ring - 02 Nos
Service Charges for Carrying out the 'B' Check maintenance of DG set of 63 KVA capacity of make Greaves, from authorized service representative from the manufacturer of DG set, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters, checking inlet & Exhaust manifold cap screws, checking of fan hub & water pump, including supply & fix in repair of following spares :-
(a) Kit, fuel filter and ring - 2 Kit
(b)Element for Lubrication oil filter - 2 Nos.
(c) Kit, Element of super bypass filter - 01 Kit
(d) Seal, O Ring - 02 Nos
Supply and topping up Engine oil 15 W 40 in DG sets. Make - Castrol / BPCL / SERVO
Supply and topping up Coolant concentrate SK 802 01C. Make:- Servo / Valvoline / Hindustan.
Supply and topping up distilled water to be filled in batteries all as directed by Enggr-in-Charge
Supply and fix in repair 100 Amps contactor AC 3 phase 415 V 50 Hz coil 440 V.
Supply and fix in repair 125 Amps contactor AC 3 phase 415 V 50 Hz coil 440 V.
Supply and fix in repair 4 pole Mini contactor , with AC coil including overload relay of range 7-10 amps.
Supply and fix in repair 4 pole Mini contactor , with AC coil including overload relay of range 12-16 amps.
Supply and fix in repair thermal overload relay 3 pole of relay range 9-14 Amps.
Supply & fix in repair battery lead of PVC insulated single core multistrandard copper conductor of size 20 Sqmm & 1.50 mete long cable, with lugs fixed in position as directed complete all as specified and as directed by Engineer-in-Charge.
S&F for repair in Right / Left hand lock with catcher for acoustic enclosure (canopy) of any capacity DG sets complete all as specified and as directed by Engineer-in-Charge.
S&F in repair for Dial type mechanical fuel level indicator for any capacity DG set complete all as specified and as directed by Engineer-in-Charge.
M & L for preparation of old painted exposed surface of DG set of capacity 25 to 63 KVA by removing dust, dirt, oil, grease etc & and painting with two coats of synthetic enamel paint of existing colour by using the air pressure spray gun machine, writing SM/ MES No to DG sets with white paint all as specified and directed by Engr-in-Charge.
Supply and fix in repair lead acid battery 12 V 180 AH with initial charging, fixing & connecting, at site of DG set including taking out old battery all as directed by Engr-in-Charge.
M&L for 100mm thick cement concrete 1:3:6 , type PCC cement concrete type C2 (using 40 mm graded stone aggregate)as in sub base /path/flooring complete all as specified and as directed by Engineer-in-Charge.
M&L for servicing/rewinding of bore well submersible pump multistage of capacity 20 HP with changing its bush , shaft, clamp and necessary grinding required in impeller to make it in good running position along with its gland and necessary fixtures complete all as specified and as directed by Engineer-in-Charge.
M&L for servicing/rewinding of open well submersible pump of capacity 30 HP with changing its bush ,clamp and necessary grinding required in impeller to make it in good running position along with its gland and necessary fixtures complete as directed by Engr-in-charge.
M&L for servicing/rewinding of monoblock pump of capacity 17.5 HP with changing its bush , shaft, clamp and necessary grinding required in impeller to make it in good running position along with its gland and necessary fixtures complete as directed by Engr-in-charge.
M&L for repairing of crackle in 80 mm HDPE/DI/CI water pipe line by provodong galvanised mild steel two piece half round clamp fabricated with 300 mm long and 3mm thick galvanised mild steel sheet, bend to shape, or with MS pipe including 8 Nos galvanised nut bolt, rubber packing complete all as specified and as directed by Engineer-in-Charge.
M&L for repairing of crack in 180 mm HDPE/DI/CI water pipe line by providing galvanised mild steel two piece half round clamp fabricated with 300 mm long and 3mm thick galvanised mild steel sheet, bend to shape, or with MS pipeincliding 8 Nos galvanised nut bolt, rubber packing complete all as specified and as directed by Engineer-in-Charge.
M&L for repairing of crack in 100 mm HDPE/DI/CI water pipe line by providing galvanised mild steel two piece half round clamp fabricated with 300 mm long and 3mm thick galvanised mild steel sheet, bend to shape or with MS pipe including 8 Nos galvanised nut bolt, rubber packing complete all as specified and as directed by Engineer-in-Charge.
M&L for repairing of crack in 180 mm HDPE/DI/CI water pipe line by providing D joint of cast iron along with its rubber ring including 8 Nos galvanised nut bolt, rubber packing complete all as specified and as directed by Engineer-in-Charge.
S&F in repair cast iron Air release valve of size 40 mm .
Supply calcium based high strength granular chlorination chemical (calcium hypochlorite having chlorine 65 % to 70%) for water treatement.Granular material shall be free of foreign material decomposing at 177 C soluble in water, not hygroscopic practically clear in water solution at saturation level. ..........
............... The material should not contain more than 5% to 10% moisture. Granule size should be as follows:- Mesh passing through 100 BSS, 1.5 % Maximum iron as Fe 0.05% maximum Mn 40 PPM maximum MOL wt 142.98, Toxicity oral rate LD 50-850 mg/Kg duly tested from manufacture or authorised dealer/distributor complete all as specified and directed by Engineer-in-Charge.
Brand name/batch number and complete particulars of manufacturer should be printed on the container/packing. Note:- Demand of this granular is given in different lot at different time during the contract period as per requirement prior notice to contractor by Engr-in-charge
M/s SK Traders
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .