Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC | ₹1.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.7 Cr+₹58,899.19 (0.36%)Accepted-AOC | ₹1.7 Cr+₹58,899.19 (0.36%) | L2 | Accepted-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical L3 |
Tender Value
₹1.6 Cr
EMD Value
₹50,000
Closing Date
24 Feb 2023, 4:00 pmClosed
Superintending Engineer
P H Circle, Muvattupuzha
Jal Jeevan Mission JJM-WSS to Santhanpara Rajakumary and Senapathy Panchayaths in Idukki District
2023_KWA_558564_1
84/2022-23/SE/PHC/MVPA
Open Tender
Civil Works - Water Works
Item Rate
270 days
P H Circle, Muvattupuzha
Please refer Tender documents.
9 documents required · 9 mandatory
₹5,515
₹50,000
18 May 2023
15 Feb 2023
25 Feb 2023
15 Feb 2023
24 Feb 2023
15 Feb 2023
Amount
Part I - Supply of Materials
100.98.115:Supply of DI K9 Pipe Conforming to IS 8329/2000, 100mm Dia.
100.98.116:Supply of DI K9 Pipe Conforming to IS 8329/2000, 150mm Dia.
100.98.440:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.
100.98.446:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Double Orifice Type DS2, Size 50mm.
100.98.460:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.
100.98.458:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
Part II - Working charges
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.4.1:Excavating in hard rock for trenches by blasting for laying pipes and stacking useful materials for measurements and disposing unserviceable materials within the initial lead of 50m and lift up to 1.50m (depth from 0.0m to 1.50m) and providing protection by earth filled cement bags during blasting to avoid damages to nearby structures (200 Nos. of earth filled cement bags for 10m3 of blasting)
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.14.1:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 100mm diameter Ductile Iron Class K-9 Pipes.
100.14.2:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 150mm diameter Ductile Iron Class K-9 Pipes.
18.30.2:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:100 mm diameter pipe
18.30.4:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:150 mm diameter pipe
OD110459/2022-2023:Labour for cutting DI pipe with steel saw 100 mm diameter of DI Pipe
OD110442/2022-2023:Labour for cutting DI pipe with steel saw 150 mm diameter of DI Pipe
18.70.1:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:100 mm dia pipes
18.70.2:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:150 mm dia pipes
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
18.67.1:Providing and laying S & S C.I. Standard specials suitable for mechanical jointing as per IS 13382:Upto 300 mm dia
100.31.2.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class II.
100.31.2.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class II.
100.32.1:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 25mm Single Acting Air Valve.
100.32.3:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 50mm Double Acting Air Valve.
100.35.1:Testing 100mm DI/CI pipeline with potable water to the required test pressure 100 mm dia
100.35.2: Testing 150mm DI/CI pipeline with potable water to the required test pressure 150 mm dia Observed Data derived from item no.1018 of PHED DATA
100.37.5.1:In situ fabrication of M.S. pipes of size 100mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.5.2:Fabricating M.S. flanges of diameter 100mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.5.3:Cutting 100mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.5.4:Welding 100mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.5.5:Grinding cut and weld edges of 100mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.6.1:In situ fabrication of M.S. pipes of size 150mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.6.2:Fabricating M.S. flanges of diameter 150mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.6.3:Cutting 150mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.6.4:Welding 150mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.6.5:Grinding cut and weld edges of 150mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
OD167024/2022-2023:Dismantling manually / by mechanical means and disposal of material within 50 metres lead as per direction of Engineer -in-Charge:<br>Bituminous road
Part III - Valve chamber construction
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
Part IV - Road restoration -PWD/SH
3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m
4.2.A.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-III -For lower sub-base - Mix in Place Method
4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.
5.2.b:Providing and applying tack coat with bitumen emulsion (RS) using emulsion pressure distributor at the rate of 0.25 - 0.30 kg per sqm on the prepared Granular Surface cleaned with mechanical broom.
5.3.2.a:Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with a bituminous binder (VG 30), transported to the site, laid over a previously prepared surface with paver finisher to the required grade, level, and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction For Grading II - (19 mm nominal size)
5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
5.6.2.a:Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with a bituminous binder( NRMB) @ 5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level, and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects For Grading - II (13.2 mm Nominal Size)
12.4:Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
12.8.B.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications PCC Grade M20
Road restoration LSGD
3.5.3:Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3
4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material
4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead
5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
5.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means (II) Bitumen (S-65)
5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 A. By Manual Means :- Case - III : Type C (II) Bitumen (S-65)
11.4.3.1:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203III. P.C.C. grade M 20 (i) Nominal mix (1:2:4)
1.4 LL Sump cum pump house at Swargamedu
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
OD124248/2022-2023:Dowel bars - Supplying and providing MS dowel bars of size 16mm dia of 2m long (1m in rock and 1m in concrete) including drilling holes of 20 mm dia and filling the gap with cement grout (.5kg/each) etc...
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.7.2:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (requiring blasting)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
22.22:Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc.. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.2.3:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.15.2:Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
OD124231/2022-2023:Supplying and providing 100mm dia vent cowl including fitting charges etc.
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.47.1:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
13.71:Lettering with black Japan pint of approved brand and manufacture
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
100.41.34:Supplying and fixing Rectangular C.I. manhole cover 455mm x 610mm with frame (low duty) charges including all cost, labour charges etc., complete.
13.65.1:Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an even shade:Two or more coats on new work
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
18.26.1:Providing and laying flanged C.I. Standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :Upto 300 mm dia
Construction of steel storage tank at Swargamedu Top
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
OD124207/2022-2023:Dowel bars - Supplying and providing MS dowel bars of size 25mm dia of 2m long (1m in rock and 1m in concrete) including drilling holes of 30mm dia and filling the gap with cement grout (.5kg/each) etc...
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
OD124199/2022-2023:Supply of Sand including loading, unloading, transportation and other incidental charges as per the direction of departmental officers.1
OD124202/2022-2023:Supply,installation and commissioning of a pre-engineered, pre-fabricated, factory manufactured steel storage Water Tank having a capacity of 30000 L(1Nos.) thickness of 0.6 mm, in multiple layers as required for the capacity and height of the tank and multiplelayered PE sheet/membrane for the inner containment liner. The Tank Shell / Body &amp;amp; the Liner material shall be manufactured in a facility certified and compliant to ISO 9001 - 2000 standards. The Tank shall be supplied with access points, penetrations for inlets, outlets, drains and fittings, overflow and drain, high and low water level indicators. All connections to the tanks shall be with flanged or threaded nozzles, placed to the KWA water mains TANK ROOF :The roof of the tank shall be of corrugated Galvalume sheet steel and shall be domed, with heavy- duty Hot-dip Galvanized truss frame for support, and capable of supporting 4-5 persons for maintenance and cleaning and tank shall have an access hatch with cover, on the roof, for operation and Maintenance TANK COVER :Tank covers shall be of approved galvanized vermin proof construction. Roof ends shall be fitted with suitable vermin-proofing tape or other material, to prevent ingress of dust and foreign objects. Covers shall be firmly fixed to the top edge of the tank with galvanized bolts and nuts. LADDERS :Tanks shall be provided with Hotdip Galvanized ladders internally or externally. External roof supports shall be of an appropriately designed Hot-dip galvanized Steel construction. Tanks shall comply with relevant spill level, air gap and overflow requirements relative to Effective Capacity. All nuts and bolts used for the panels shall be a minimum of 12mm size and hot-dip galvanized/Case hardened. The tank shall have a circular angle fixed around the total circumference of the tanks, at the top, of minimum 2 mm thickness. Tanks shall be properly flushed out with clean water prior to being brought into service TANK DIMENSIONS: The dimensions of the Tank shall be of 3.884 m in diameter and 2.9 m in height DESIGN LIFE: The tanks shall have a design life of 40 years. TANK CONNECTIONS: Standard design valve outlet connection : i) 150mm CI Flanged valve ii) Overflow connection including an Internal approved bell-mouth shaped bends to maximize the overflow capacity. One no. 100 mm, iii) One (1) scour drain outlet from the floor of the tank with isolation valve. One No. 100mm.TANK LINERS:Tank liners shall be purposedesigned and manufactured and shall comply to AS/NZS 4020 (Appendix A )of 2005 and ANSI/NSF 61 - 2008, Section 5 Certificates of compliance to above standards shall be furnished by the manufacturer of the tanks. Tank liners shall: i) Be factory manufactured to onepiece construction, fabricated from multi-layer PE sheet, certified for potable drinking water, to (ANSI/ NSF 61) and duly UV Stabilized. ii) Be of PE (polyethylene) in multi-layer construction for strength, reinforced with woven scrim industrial fabric to prevent elongation and enhance tensile strength. The total liner material thickness shall be no less than 0.6 mm thick. The tensile strength shall not be less than 2266 N (warp) and 2495 N (weft) and heat sealing strength of 2056 N v) All the liner welded lap joints shall be strengthened with Metallocene encapsulating tape welded over the overlap. vi) The Metallocene tape shall cover and protect the exposed material at the edges of the liner joints to further prevent the ingress of water into the scrim. vii) Liners shall be positively and continuously attached to the top outer edge of the circumference of the tank to prevent entry of water from the runoff from the roof structure. viii) All liners on tanks over 2m in height shall have a continuous intermediate liner support designed out of nylon (or other material)cord, around the circumference of the tank, at vertical intervals corresponding to the level of each ring. ix) The intermediate liner support cords shall be firmly secured to the steel shell at each level, to prevent stress on the liner welded joints, and thereby eliminate possibility of failure CORROSSION PROTECTION. The tank structure shall have a secondary corrosion protection system using sacrificial magnesium anodes. The number of anodes, their location around the tank and the mass of each anode shall be designed for anode replacement frequency of five years. The anodes shall be installed external to the tank and concrete apron with their location marked with a suitably label-Cost for Tank steel with 10years guarantee includes shel l,Steel wall,steel domed roof,Zinc Alum steel&amp;39;,Cost for Poly ethylene infinity liner ,Geo synthetic Fibre with food grade plastics are used for inside coating and Support Arrangements,Cost for Fabricated items,attachments and accessories like steel ladder,Cost of Fabricated nozzles,over flow nozzles and drain arrangements, Cost for HDG nut and bolts,Freight Charges,Erection Installation and commissioning of tank components.
Electrification works & Supply erection testing and commissioning of clear water pump set at Swargamedu booster .
OD150812/2022-2023:Supplying and fixing LED tube light T-5,high luminous along with ceiling rose as per the direction of the departmental officers
OD150813/2022-2023:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. As per Databook DAR Electrical-5.14.
OD150814/2022-2023:25mm PVC Conduit- Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessincluding cutting the wall and making good the same in case of recessed conduit as required. 25 mm .As per Databook DAR Electrical-1.21.2.
OD150815/2022-2023:Wiring with 3x 4 sq mm FRLS PVC insulated copper conductor-Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existingsurface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm As per databook DAR Electrical-1.17.21.
OD150816/2022-2023:12 Way MCB DB 240V -Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 12 way, Double door. As per Databook DAR Electrical-2.3.3.
OD150817/2022-2023:SPN 5-32A MCB-Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. Single pole and netural .As per Databook DAR Electrical-2.10.2.
OD150818/2022-2023: DP Isolator 40A -Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 40 amps .As per Databook DAR Electrical-2.12.1.
OD150819/2022-2023:RCCB DP 40A - Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuitbreaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps . As per Databook DAR Electrical 2.14.2.
OD150820/2022-2023: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copperconductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitableGI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B. As per Databook DAR Electrical 1.10.2.
OD150821/2022-2023:Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. As per Data book Electrical 5.6
OD150822/2022-2023:Expenses of getting electrical connection from KSEB including documentation fee, service charges, energization charges etc
OD150823/2022-2023:Supply, conveyance, installation and commissioning of light duty Exhaust fan of 300/305mm sweep in metal frame working on 230V A/C 300 sweep including making good the damages etc as required as directed by the departmental officers
OD152594/2022-2023:Supply conveyance ,installation testing and commissioning of36/40 W LED street/Yard light out put greater than105 lumen/watts 4000-6000K with IP66 protection with LED chip make cree/Lumilled/Nichea with powerfactor greater than 0.95 at full load ,internal surge protection up to 8 kv and alluminium preasure die cast powder coated housing acryliccover complete with THD less than 10% power factor greater than 0.98 R0HS compliant duly wired up for use on 230v AC supply.Driver compartment should be separately accessible for maintanance(LM 79&80 Certificate from NABL acredited third party lab produced mentioning chip manufacturer)
Roopesh K Rajappan
Bobby Kurian
Bidder Name
Bobby Kurian
Roopesh K Rajappan
KURIANPRASAD
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_821902.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .