| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.7 LAccepted-AOC CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹52.3 L+₹3.6 L (7.38%)Rejected-AOC PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L2 | Rejected-AOC Admitted | |
| 3 | L3₹52.9 L+₹4.2 L (8.55%)Rejected-AOC | L3 | Rejected-AOC Admitted |
Tender Value
Refer Docs
EMD Value
₹97,784
Closing Date
12 Mar 2025, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
PROVN OF HIGH MAST LIGHT IN CHILDREN PARK AT SMA NAVAL BASE, KOCHI, SPL REPAIRS/REPLACEMENT OF EXTERNAL LIGHTING, GARDEN LIGHTS, LT UG CABLES AND LT SWITCH GEAR NEAR BLDG NO P-97 AT KATARIBAGH
2025_MES_692238_2
8347/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹97,784
Yes
30 Jun 2025
19 Feb 2025
14 Mar 2025
19 Feb 2025
12 Mar 2025
27 Feb 2025
Amount
Material and Labour including supply, transmission, install, commissioning and unit testing of f 12.5M high mast lights in two section(top100mm/Bottom 360mm- 3mm sheet thickness-445 PCD) suitable for 55 m/sec wind speed along with head frame, luminaires carriage suitable for 06 luminaires in symmetrical arrangement and other accessories manufactured in factory consisting of the following Make Surya/ Bajaj/Crompton a) Raising lowering of system comprising 200Kg double drum winch, 5mm diameter SS wire rope, trailing cable, connector, integral three phase power tool motor, manual handle, junction box and lightning. b) M30X80M EN8 Grade foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template. c) 200W LED Floodlight luminaire with minimum 24000 Lumens Light output in CRI>70. Powder coated pressure die-cast aluminium LEDhousing designed to act as heat sink for efficient dissipation of heat.LEDs are provided with secondary Polycarbonate lens optics to get optimum optical performance .Luminaire should have Minium IP 66 and IK 07 Protection. Internal Surge protection of 4KV and External surge protection of 10 KV in minimum required. The luminaire shall be designed to ensure lumen depreciation L70 over 50000 burning hours as per LM 80 report. Driver shall have a power factor >0.95 and THD >10%. ( Bidder should submitted LM 79 Report from a NABL Accredited lab, LM 80 Reports, Type test report and TDS along with tender) SLE FL 200W IP66 LIVIA G1- 6 nos of Light/ high mast d) Low intensity LED type single dome aviation obstruction light- 1 No/high mast.
e) Outdoor stand mounted feeder pillar withdouble door type of 3 mm 1 bulk CR CA sheet, 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button,Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminal, with MS stand made of suitable size of angle/channel of length 45 cm height, above ground level- 01 No f) Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour.( Foundation considered as per our standard drawing)/ drawing submitted by OEM. g) Material and Labour for erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB.
Material and Labour for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to galvanized iron strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer nuetral/body/ Lt panel etc. and testing on completion, complete all as specified & directed by Engr-in-Charge.
Material and Labour for Supply and fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm, 3.5 core in trenches/under road/on walls/ on poles complete all as specified and directed
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unseviceable LT Cable for laying of cable complete all as specified and directed.
Material and Labour Sand cushioning and covering of UG cable using crushed riddles soil in trenches for cable protection complete all as specified and directed. Note :- Sand cushioning in before laying of cable 8cm and 15 cm after laying the cable and punned to a thickness of 18 cm thick. Punned thickness only will be measured for purpose of payment.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed by Engr-In-Charge.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed
Material and Labour for Brick well burnt Class 'B' as in cover to UG cable, laid dry. flat over the cable with width equal to legth of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over UG cable for cable protection in trenched complete all as specified and directed
Material and Labour for Cutting existing road/hardstand/concrete blocks/slabs/brick work or stone masonry of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers cold mix bitumen over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Material and Labour for GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc complete all as specified and directed of size 40mm dia
Supply and fixing in replacement of decorative LED Post Top lantern 40/45 watts, Stellar LED pot top offering combination of study design, excellent illumination and aesthetic in one go IP 66 and IK 10 rating ensure it stands tall amid varid environment conditions, suitable for pole/pipe dia 76mm, compete all as specified and directed by Engr-in-Charge. Including taking down unserviceable lights. Make and model as approved by accepting officer.
Supply and fixing inreplacement of 3 Mtr Mat black decorative Polyurethane painted pole made of galvanised steel tubing with bottom dia 114mm, top dia 60mm with height swaged at 2000 mm with total length 3 metres, die cast base of dia 340mm, decorative casting rings and service window at bottom for MCB and terminal block, fixing arrangement including erecting of pole, nut, bolts etc as per OEM Drawings attached, icluding dismantling of existing unserviceable pole, complete all as specified and directed.
Supply and fixing inreplacement of 25 Watt new generation, Post-Top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, Spun aluminium white reflector and clear diffuser landscape luminaries with high power LED as lighting source with IP65 Protection PF>0.95 ; THD less than 10% CCT-5700K , complete all as specified and directed
Supply and fixing inreplacement of 15 Watt WH/WW/ new generation, Post-Top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, Spun aluminium landscape luminaire with high power LEDs as light source, Opal cover offers soothing uniform illumination for different appliances. with IP65 Protection PF>0.95; incl taking down unserviceable lights complete all as specified and directed
Supply and fixing inreplacement of 10 Watt LED Bollard Pyramid tripod type decorative type new generation, Bollard, energy saving, environmental friendly, long life with soft 360degree light distribution ,with high power LEDs as light source, offering uniform illumination for different appliances. with IP65 Protection PF>0.95 . The rate incl fixing in ground making excavation and PCC foundation and taking down unserviceable lights complete all as specified and directed.
Supply and fixing in replacement of 6 Mtr hot dip galvanized octagonal pole conforming to BSEN 10025 & galvanization BS EN ISO 1461 or Equivalent with 3 mm sheet thickness and > 65 microns with confirming windspeed of 47 M/s . Pole should be of 70mm top dia and 130mm bottom dia . The pole should have inbuild door munting 500mm above from ground with proper gaskets & alien key arrangemnet for safety locking. Pole should withstand in 4 Nos of END hot dip galvanized M20x 600mm "J" bolts and baseplate of 200X 200mm with a 12mm thickenss conforming to IS 2062 . PCD=220mm . Conforming BSEN10025 ; BESEN ISO 1461, including dismantling of existing unserviceable pole complete all as specified and directed
Supply and fix in replacement of 70w LED street light with die cast aluminum housing and IP lense with IK08 ; THD0.95 ; CCT :5700K . Spd OF 4 KV+10KV complete all as specified and directed
Supply and fix in replacement of LED Flood light fitting 1x100 Watt green/white colour made up of pressure die cast aluminium housing with toughened glass and high power LEDs IP66/65, and wired with all accessories including earth work and making PCC foundation for fixing complete all as specified and directed including taking down old unserviceable fitting
Supply and LayIing in replacement of UG cable XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 4 core 10 Sqmm laid in trench /duct/floor/wall with provision of saddle and lugs, joints etc including connection and taking down old cable complete all as specified and directed
Supply and Laying in replacement of UG cable XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 4 core 16 Sqmm laid in trench /duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed
Supply and Laying in replacement of UG cable XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 3.5 core 50 Sqmm laid in trench /duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed
Supply and Laying in replacement of UG cable XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 3.5 core 120 Sqmm laid in trench /duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed
Supply and Laying in replacement of UG cable XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 3.5 core 150 Sqmm laid in trench /duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and fix, cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade suitable for 3.5/4 core x 70 to 150 sqmm including taking down of old one , complete all as specified and directed
Supply and fix, cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade suitable for 3.5/4 core x 25 to 50 sqmm including taking down of old one, complete all as specified and directed
Supply and fix, cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade suitable for 3.5/4 core x 10 to 16sqmm including taking down of old one,complete all as specified and directed
S & F inreplacement of street light TIMER control panel, Timelite-63A 3Pole/230V-Digital Time Switch, pole/wall/PCC Platform mounting made out of 3.15 mm CRCA sheet duly powder coated with locking arrangement, incl internal wiring complete with bypass arrangements and necessary PCC foundation (as manufactures recommendation and design) complete all as specified and directed
Supply & install, testing and commissioning in replacement of outdoor type LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply sysytem conforming to IS : 8623/93, floor mounted with angle iron support, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 40mm X 40mm X 6mm thick frame work and CRCA sheet 3mm thick of out door and 2mm thick inner door having Aluminum bus bar of rating 600 Amps,three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The size of the panel as per recommendation of original manufacturor, mounted on angle iron stand made out of size 40mm X 40mm X 6mm grouted of digital volt meter & AMPs meter with CTs including taking down of old existing panel complete all as specified and directed by the following specifications :- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 600 Amps aluminium strip -1 Set (b) Onload change over switch 400 A, 4 Pole (Incommer) (c) MCCB 250 Amp 35 KA 4 pole - 01 No (Outgoing) (d) MCCB 160 Amp 25 KA 4 pole - 02 Nos (Outgoing) (e) MCCB 63 Amps 25 kA 4 pole - 02 Nos (Out going) (f) Volt meter digital 0-500 volt - 01 (g) Amp meter digital 0-300 Amp - 01 (h) Indicator lamp Yellow, Red, Blue - 01 Set
Supply and lay in replacement in trenches/fixed on walls/poles GI tubing medium grade with all fittings of 40 mm bore complete all as specified and directed.
Supply and lay in replacement in trenches/fixed on walls/poles GI tubing medium grade with all fittings of 80 mm bore complete all as specified and directed.
Supply and fix in replacement of junction box made of hot press moulded SMC junction boxes of size 250x 200x 105mm, shock proof and dust proof, pole mounted, cable entry from bottom, with IP 66 protection including cable connector with single MCB 6-32 Amps, suitable size clamps fixing for pole/in pcc foundation including taking down old unserviceable fitting complete all as specified and directed
Supply and lay in replacement High density poly ethylene pipes (HDPE) 40mm dia of pressure rating 6 kgf/cm2 laying in trench and fixed complete to walls, ceilings or in floors etc. complete all as specified and directed
Cutting existing concrete/metal/ bituminous road/PCC hard standing or tile walk way any type n.exc 45 cm width and n.exc 30 cm in depth in hard strata and making good disturbed surfaces,as per the existing with cold bitumen over returning filling, watering ,ramming in layers ,disposal of surplus material to a distance n.exc 50 m, complete all as specified and as directed.
Supply and fixing in replacement wiring with three core (2x1.5 sqmm, 1x1.5Sqmm for earthing) of PVC (FRLS) insulated multistranded copper conductor cable of 1.5 sqmm drawing through PVC conduits with contineous earth wire PVC (FR) insulated cable of size 1.5 sqmm connected to earth including all conduit accessories. (Note : Three run of sub main wire, and one run of PVC Conduit pipe with 2x1.5sqmm and 1.5Sqmm earth wire measured as one unit). complete all as specified and directed
Material and labour for dismantling and shifting of serviceable Garden light/Bollard of any height carefully including dismantling from existing foundation and making new foundation and fixing new location and cable connection to light made functional complete all as specified and directed, Note: (1) Any damage of the lights or pole will be the responsible of the Contractor.
Material and labour for dismantling from existing location and shifting of pole steel tubular pole/ Octogonal street light pole of any height including dismantling from existing foundation and making new foundation at new location and connection complete all as specified and directed by Engr-in-Charge Note: (1) Any damage of the light or pole will be the responsible of the Contractor.
Material and labour for dismantling from existing location of Decorative 3 mtr pole steel tubular pole at new location of any height including demolishing existing foundation and making new foundation at new location complete all as specified and directed by Engr-in-Charge. Note: (1) Any damage of the light or pole will be the responsible of the Contractor.
Taking down of cable any size or any capacity from trench/wall/floor and relocated the serviceable cable unserviceable cable issue to contractor under schedule of credit complete all as specified, the rate shall be included for excavation for taking down cable, and new location cable laying including new location excavation, sand, bricks shall be paid separatly respective of same shedule.
Material and Labour in replacement for earthing complete with galvanized iron or steel earth plate electrode 60cmx60cmx 6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to galvanized iron strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer nuetral/body/ Lt panel etc. and testing on completion, complete all as specified & directed by Engr-in-Charge.
Supply and Fix Copper tube Should be soiled drawn seamless deoxidized, non-arsenical, half hard, tempered and degreased as per BS EN 13348:2001 duly supported with manufacturer test certificates for physical properties and chemical composition. The Tubes should be supplied with Third Party Test Certifications like LLOYD/TATA/SGS/CITCO every tube should have batch no. According to Test Certificates
(a) 12 mm dia x 0.6 mm thick
(b) 15 mm dia x 0.7 mm thick
Supply and Fix Isolation Valves (CE Marked)of size 15mm dia to control the pressure as well as for maintenance Pupose quarter turn open at 90-degree ball type valves Should be provided. These valves Should be of nickel-plated brass body having PTFE seat and inner outer seals. These valves Should have stainless steel ball of specific ID clearance so that line pressure Should not drop. For installation only PTFE gaskets Should be used in between nuts and valve to prevent leakage. All the nuts for fixing the ball valve Should be of brass with brass nozzles for easily brazing with copper tube. All ball valve assemblies Should be on approachable height for easily operation. TECHNICAL SPECIFICATION :- 1. Leakage Clause : 1 2. Temperature range : Ambient 3. Working Pressure : 7.5 bar maximum 4. Test pressure : 50 bar maximum 5. Standard : As per HTM 2022 6. Size : 15mm
Supply and Fix Bed Head Panel of size 4 ft long made out of 1.6 laminated aluminium sheet die pressed in such a shape that looks good as per requirement.The modular medical turn king system/bed head panel: would be fabricated of aluminous die pressed 1.6 mm thick imported laminated sheet in such a way to provide 100% safe and efficient means to deliver all the gases as well as electrical to the patient/staff in intensive care conditions. To enclosed all piping, electrical wires, monitor wire etc.The design of modular BHU would consist of aluminum section to meet the requirement of HTM 2002, NFPA and other international standard.There would be no sharp edges having smooth finish and without any visible.It would be have ability fix medical gas outlets, electrical sockets. Note:- Bed head Panel having prrovision of Oxygen -1, Vaccum -1, Air -1, 5 Amp socket-2, 15 Amp socket -2 with switches
Supply and Fix Bed Head Panel of size 4 ft long made out of 1.6 laminated aluminium sheet die pressed in such a shape that looks good as per requirement.The modular medical turn king system/bed head panel: would be fabricated of aluminous die pressed 1.6 mm thick imported laminated sheet in such a way to provide 100% safe and efficient means to deliver all the gases as well as electrical to the patient/staff in intensive care conditions. To enclosed all piping, electrical wires, monitor wire etc.The design of modular BHU would consist of aluminum section to meet the requirement of HTM 2002, NFPA and other international standard.There would be no sharp edges having smooth finish and without any visible.It would be have ability fix medical gas outlets, electrical sockets. Note:- Bed head Panel having prrovision of Oxygen -2, Vaccum -1, Air -1, 5 Amp socket-2, 15 Amp socket-2 with switches Make: MEC
Supply and Fix BPC Flowmeter with humidifier bottle (4 Digit CE Marked) of single type Pipeline Flow Meter unit duly fitted with the fine adjustmentvalve. It Should be back pressure compensated to bear and control the Oxygen Pressure approx. 60psi. Flow meter unit Should be consisting of double wall rotta-meter has range of flow 0 to 15 ltrs. per minute with fine adjustment valve. The rotta meter and humidifier bottle Should be made of clear, impact resistance polycarbonate (duly graduated). This unit Should be have attachment to fit humidifier bottle of capacity 100 Ml. consist of clear, impact resistance polycarbonate jar. This Should also have Screw on top for flow meter/plastic cap having nozzles for outlet tubes and the inlet tube end Should be multi function combination bubblier/ nebulizer to add the humidity and create an aerosol in Medical Gas. Min/Max mark Should be on the Bottle.
Supply and Fix Ward vacuum unit (4 Digit CE Marked) with vacuum regulator Should be fitted with vacuum gauge and it also shows flow rate.It Should also have overflow safty trap.It Should also have emergency on / off lever and fine adjustment valve for regulator. This system Should be supplied with pre fitted color coded gauge having dial size 50mm and vacuum 0 to 760 mm / hg and supplied with all the inter connectiong tube. The Jar is made out of Poly carbonate Clear material, duly graduated having autoclave properties upto 120 °C, the capacity of jar is 600ML.
Supply and Fix Gas Terminal Unit (4 Digit CE Marked) made out of hard Polycarbonate material with pressure injection molding process. The Base Plate, Upper Plate & Holder should be made out of above material only. The main housing should be made out of 25 mm or above size brass casting with fine machinery. 12 mm dia medical grade 150 mm long copper tube should be fixed with housing. There should be Nilon/Teflon 'O' ring and stainless steel ball to act as NRV. The gas terminal unit should be capable of single hand working and must have online servicing facility. It should have double lock facility.The Prob/Adopter should be non-inter changeable for specific gas and box should be colour coded as per specific gas with following specifications :- a. It should be front insertion type. b. Terminal unit Should have mechanism with check valve. C. Allow single hand operation. D. On first insertion of probe the probe shall sit in housing as standby position. At this stage there shall be no gas flow. E. Only on pressing the probe second time, the gas supply Should start. F. This Should close automatically when connected apparatus is removed. - G. For allowing on line maintenance the terminal unit Should be equipped with a check valve for all positive pressure gases for closing gas supply whenever the outlet point is opened. H. The outlet Should be non interchangeable for specific gas and it Should accept only correct medical gas adopter/Probe. I. It Should be color coded as per HTM 2022 & BSEN 7396 Part 1(2007) J. The design of this outlet Should be compatible to installed vertical on valve horizontally on ICCU panel and area servicing unit and also vertical to fit in pendants. K. It Should only supply with correct probe/ adopter.
Oxygen terminal unit
Medical Air terminal unit
Vacuum terminal unit
M&L for Sub main/circuit wiring 2x4.0 sq. mm earth wire with 1x4.0 sq. mm of FRLS PVC insulated copper conductor, single core cable in PVC conduit/casing caping on surface/recessed as required complete all as specified and as directed.
pk janardhanan (BID ID -3260917)
ABM ELECTRICALS (BID ID -3255791)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .