Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC DOOR NO 32 939C 1ST FLOOR CITY SCAPE BUILDING CHANGAMPUZHA NAGAR P O SOUTH KALAMASSERY ERNAKULAM KERALA 682033 | ERNAKULAM | KERALA | 682033 | ₹3.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.3 Cr+₹8.3 L (2.58%)Rejected-Finance | ₹3.3 Cr+₹8.3 L (2.58%) | L2 | Rejected-Finance L2 |
| 3 | L3₹3.4 Cr+₹13.0 L (4.02%)Rejected-Finance 37 1634 IMPERIAL HOUSE KALOOR KATHRIKADAVU KATHRIKADAVU ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | ₹3.4 Cr+₹13.0 L (4.02%) | L3 | Rejected-Finance L3 |
| 4 | L4₹4.1 Cr+₹85.7 L (26.5%)Rejected-Finance C O VOLTAS LIMITED SPARE PARTS DEPOT OLD HUTMENT COLONY NCL NIGAHI SINGRAULI M P 486884 | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486884 | ₹4.1 Cr+₹85.7 L (26.5%) | L4 | Rejected-Finance L4 |
Tender Value
₹3.1 Cr
EMD Value
₹1 L
Closing Date
11 Dec 2021, 3:00 pmClosed
MD INKEL Limited
2nd Floor, Ajiyal Complex, Kakkanad, Cochin, Pin 682030
Electrical, ELV, Fire Fighting and HVAC Works for the Extension of Cancer Specialty Block for General Hospital, Ernakulam
2021_INKEL_456396_1
NIT/INKEL/CSML/2021-22/266 dated 25/11/2021
Open Tender
Civil Works - Buildings
Item Rate
180 days
General Hospital Ernakulam
as detailed in tender document
13 documents required · 13 mandatory
₹8,850
₹1 L
11 Jan 2022
25 Nov 2021
13 Dec 2021
25 Nov 2021
11 Dec 2021
26 Nov 2021
Amount
ELECTRICAL WORKS WIRING
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.4 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required but excluding GI back box.
Supplying and fixing suitable size modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required but excluding GI back box.
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required.
MCB AND DBs
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.4.1 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
2.4.2 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door
2.4.3 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).<br>12 way (4 + 24), Double door
2.5.1 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required. 6 way (4 + 18), Double door
2.5.3 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way (4 + 36), Double door
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
MV AND HT CABLE LAYING
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
7.2.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing HDPE pipe as required. Above 185 sq. mm and upto 400 sq. mm
Supply and laying of necessary dia. heavy duty HDPE pipe (as per Is 4984 PE-80 GRADE (Virgin ) material) PN - 6 for laying for 1RX3.5CX400 Sqmm A2XFY cable from existing substation to cancer block road crossing by horizontal drilling method including drilling, boring, rimming etc. The cost including all labour charges including digging the pit where ever necessary, supply and laying of HDPE pipe with all accessories as required as directed by the Engineer in charge.
MV AND HT CABLE JOINTING AND END TERMINATION
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4cx6 sq mm
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 2CX4 sq mm
CABLE TRAY
Supply and fixing of Perforated Cable tray with all accessories including horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a maximum safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. 100 mm width X 60mm Height
Supply and fixing of Perforated Cable tray with all accessories including horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a maximum safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. 200 mm width X 60mm Height
Supply and fixing of Perforated Cable tray with all accessories including horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a maximum safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. 400 mm width X 60mm Height
DIESEL GENERATORS
DIESEL GENERATORS Supply, Installation, Testing and Commissioning of 200 kVA prime rated D.G set with acoustic enclosure and control panel, protection and digital metering, controls and interlocks, CT's and transducers for all metering and protection with suitable size breaker, including antivibration mountings, exhaust silencer conforming to latest environment protection regulations for emission and noise levels, water/coolant cooled, ( radiator type) four stroke, electric start conforming to BS: 5514 , brushless, self excited, self regulated and suitable for continuous operation at 1500 RPM, generating 415 V +/- 5% Volts at 0.8 p.f (lag),50 Hz, 3Phase, 4 wire system generally conforming to IS 4722. Both Engine and alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards, Inbuilt Fuel tank suitable for 8 hrs continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size of cable termination box etc.as required and as per specifications.The work should be as per Electrical Inspectorate / pollution control board standards.(Civil works excluded).
EXHAUST PIPES Supplying and fixing exhaust piping of suitable dia for 200 kVA DG set, welded black M.S 'B' class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh & aluminium cladding etc. Piping shall be with long radius bend from residential silencer with necessary clamps, fixtures, suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps angle, channel, I section, necessary nut and bolt and all required accessories including cutting, hoisting, fixing in position and applying 2 coats of primer and 2 coats of enamel paint of approved quality etc as required in the steel works etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.
AUTO POWER FACTOR CORRECTION
LT PANELS
MEDICAL GAS SM DB Supply, erection, testing and commissioning of wall mounting type, double door 3 phase 6 way Load Bank of approved make IP43 and quality with cable end box, meter module including busbar, neutral link and DIN bar with all accessories etc complete with all connections and interconnections as shown in the schematic drawing, Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge / consultant. This panel should include pluggable type surge arrester in suitable enclosure Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 21 kA (10/350μ sec) for Line to Neutral & 25 kA(10/350μ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20μ sec) for Line to Neutral & 40 kA(8/20μ sec) for Neutral to Earth, max discharge current 150 kA (8/20μ sec) for Line to Neutral & 50 kA(8/20μ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse as required and as directed. Incomer - 125 A FP 25kA thermal magnetic release MCCB - 1No. 125A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Prewired meter module including all meters and indicating lamps - 1 Set Cable alley - 2 Set Class B+C / Class 1+2 Surge arrestor device with enclosure & necessary MCCB for protection of same - 1 No. Outgoings<br>40A 16kA TP+NL MCCB, with thermal magnetic release - 2 Nos. 32A 16kA TP+NL MCCB, with thermal magnetic releas - 4 Nos. Supply, Installation, testing and commissioning
LOAD BANK - 1F + 2F Supply, erection, testing and commissioning of wall mounting type, double door 3 phase 8 way Load Bank of approved make IP43 and quality with cable end box, meter module including busbar, neutral link and DIN bar with all accessories etc complete with all connections and interconnections as shown in the schematic drawing, Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant. This panel should include pluggable type surge arrester in suitable enclosure Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 21 kA (10/350μ sec) for Line to Neutral & 25 kA(10/350μ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20μ sec) for Line to Neutral & 40 kA(8/20μ sec) for Neutral to Earth, max discharge current 150 kA (8/20μ sec) for Line to Neutral & 50 kA(8/20μ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to 80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse as required and as directed.<br>Incomer - 125 A FP 25kA thermal magnetic release MCCB - 1No.<br>125A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Prewired meter module including all meters and indicating lamps - 1 Set Cable alley - 2 Set<br>Class B+C / Class 1+2 Surge arrestor device with enclosure & necessary MCCB for protection of same - 1 No.<br>Outgoings<br>50A/63A 16kA TP+NL MCCB, with thermal magnetic releas - 3 Nos.<br>40A 16kA TP+NL MCCB, with thermal magnetic releas - 3 Nos. 25A 16kA TP+NL MCCB, with thermal magnetic releas - 2 Nos. Supply, Installation, testing and commisioning
CABLES AND END TERMINATION
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5CX300sq.mm Al Cable
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5CX240sq.mm Al Cable
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5CX185sq.mm Al Cable
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5CX120sq.mm Al Cable
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5CX70sq.mm Al Cable
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5CX50sq.mm Al Cable
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5CX35sq.mm Al Cable
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4CX25sq.mm Al Cable
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4CX16sq.mm Al Cable
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4CX10sq.mm Al Cable
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4CX6sq.mm Al Cable
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 2CX6sq.mm Al Cable
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 2CX4sq.mm Al Cable
Supply and laying and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in meduin duty conduit / cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant. 1CX25 Sq.mm Copper Flexible Cable
Supply and laying and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in meduin duty conduit / cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant. 4x2.5sq.mm Cu Control Cable
Supply and laying and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in meduin duty conduit / cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant. 12CX2.5 sq mm
Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. 1CX25 sq.mm Cu Cable
Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. 4x2.5sq.mm Cu Control Cable
Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. 12CX2.5sq.mm Cu Control Cable
LIGHT AND FAN FIXTURES
Supply of Integral, SMD 2x2 LED, IP 20, 36W LED Recessed/Surface mounted fixture with UGR<19 and System efficacy of more than 100lm/W and system lumen output 3600lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia / Cree / Bridgelux / Lumileds should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Multistage, Isolated type, APFC, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 2KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Complying to SELV < 60V DC standards. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 Wipro Model No. CRCO10R036HP57UGG2/CRCO10S036HP57UGG2.
Integral, SMD 2x2 LED, IP 20, 36W LED Surface mounted dropdown fixture with System efficacy of more than 100lm/W and system lumen output 3600lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia / Cree / Bridgelux / Lumileds should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Multistage, Isolated type, APFC, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 2KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Complying to SELV < 60V DC standards. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 Wipro Model No.CRCO10S038HP57GL1.
MOLLIS LED DOWNLIGHT: 18W, High efficient recess/SM mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI>80, IP20, Ambient temp-0 to 45DegC, CCT - 4000/5700K, 50,000 hrs @ L70 life.Driver efficiency>85%, THD<10%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level 60V DC as per IEC standard.<br>Luminaire lumen 1800 lm. (100 lm/W) - Cutout Diaø145mm
Integral, SMD 2x2 LED, IP 20, 24W LED Recess mounted fixture with System efficacy of more than 120lm/W and system lumen output 2880lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia / Cree / Bridgelux / Lumileds should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Multistage, Isolated type, APFC, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 2KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Complying to SELV < 60V DC standards. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 Wipro Model No. RCO10R024HP57HEG2
Supply of LED Tube Lights of 36W High efficient LED batten surface/wall mounted Specially designed extruded Aluminium housing with PC diffuser. In-built electronic driver duly wired up to terminal block.IP20, CRI >80, Temperature range-0 to 50DegC, Driver efficiency>90%, Power factor>0.9, CCT - 6500K, THD<20%, Surge protection 2kV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.<br>Luminaire lumen 3600 lumens (100 lm/W) Makes: Wipro-LL22-511-XXX- 65-G1 or Equivalent
Supply of LED Tube Lights of 40W(+/- 10% Tolerance) with Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor >0.9,THD<10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. Makes: Wipro- LL24-541-XXX-57-XX or Equivalent
SITC of Bulkhead of 10W(+/- 10% Tolerance) with polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor >0.9,THD<10%, system efficacy greater than or equal to 80 lm, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips, Wipro, Bajaj.
Integral, SMD 2x2 LED , IP 65 (from front) 42W LED Recess mounted Bottom Opening Clean Room Luminaire with Screwless frame and System efficacy of more than 90 lm/W. Luminaire shall be made up of CRCA Housing with CRCA Powder Coated / SS Bottom Frame. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be PC constructed, Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 140V to 300V (nominal rated voltage – 240V) with 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 Wipro Model No. LC20-551-XX-57- G2M with mounting clamps (LCX204SCRMB)
Supply, installation, testing and commissioning of analog controller for above fixture, with SS finish, control up 20 luminare including necessary backbox, front plate, cover plate, connections and inter connections as per the direction of Engineer in charge. Similar to Wipro Make cat No: 140-202 or equivalent.
Supply, fixing, testing and commissioning of 5 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate diamentions 200mm length x 200mm bredth x 12mm thickness, EN8 grade Foundation bolts of size 4 x 16 mm dia, having bolt length of 450 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO. Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall be with one arm of minimum 0.5 meter long for fixing 45 W LED fixture (Similar to Wipro make : LR02-501-XXX-57-XX LED Street Light). The cost inclusive of all material required for complete installation including light fixture, pole, foundation etc. required as per the specification
Supply, fixing, testing and commissioning of 3 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate diamentions 200mm length x 200mm bredth x 12mm thickness, EN8 grade Foundation bolts of size 4 x 16 mm dia, having bolt length of 450 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO. Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall be with one arm of minimum 0.5 meter long for fixing 25 W LED fixture (Similar to Wipro make : LR06-311-XXX-57-XX LED Street Light). The cost inclusive of all material required for complete installation including light fixture, pole,foundation etc. required as per the specification.
Supplying of ceiling fan of 1200mm sweep, energy efficient 5 Star rated, BLDC motor, High Speed, high power factor above 0.95 including the down rod of standard length (upto 30 cm). Similar to Havells , Crompton or equivalent.
Supply, installation, testing and commissioning of wall fan of 450mm sweep, 1200 RPM, 70 Cu.Mtr/Min Air delivery. Plastic body & blades with pull cords for speed regulation & wide oscillation control. Aerodynamically designed blades for high air efficiency. Similar to Crompron Greeves Make, Model No: High Flo LG 18 or equivalent
UPS 25 kVA UPS - Modular Supply, installation, and commissioning of 1 Nos. 25 kVA Modular three phase UPS in and out with built in PRS configuration inside the frame, Hot swappable and multi controller and Independent phase management, vertical & horizontal paralleling of power modules. indoor (IP21) with surge protection system with 15 min backup battery @ 25 kVA load matching the VAH of 13440 (SMF battery of reputed approved make), having redundancy in battery bank, Input pf >0.99, Input THDi <3%, input current consumption, External isolation transformers at output side, with necessary battery circuit breaker, double conversion technology with input 400V, 50Hz three phase, output 400V, 50Hz three phase, SNMP card for network monitoring, BMS compatibility etc. It shall be 100% generator compatabile, with Efficiency > 96% and output power factor Unity (25kVA= 25kW), with minimum 4 modules Eco mode Efficiency 99% and including all accessories etc as required.The system shall comply to IEC /EN 62040-1 and relevant IS standard. The acoustic noise at 1m of the system should be 62dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. and PEP certified product. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic & manual bypass switch. The system shall have IGBT rectifier and inverter.<br>Accessories like battery rack, interconnecting cables, battery isolators etc. Supply, installation, testing & commisioning
LIGHTNING AND EARTHING PROTECTION
Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts,sockets etc as required for complete installation as instructed by engineer in charge/consultant. 25x3 Cu strips tinned at the joints
Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts,sockets etc as required for complete installation as instructed by engineer in charge/consultant. 32x3 Cu strips tinned at the joints
Supply and laying the following sizes of earthing bare copper/strips on wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. 32x6mm Cu strips tinned at the joints
Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts,sockets etc as required for complete installation as instructed by engineer in charge/consultant. Copper wire No.10 SWG
Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts,sockets etc as required for complete installation as instructed by engineer in charge/consultant. Copper wire No.8 SWG
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br>32x6mm Cu strips tinned at the joints
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. 25x3 Cu strips tinned at the joints
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. 32x3 Cu strips tinned at the joints
Supply, installation and tesing of 1200mmx1200mmx12mm CI plate electrode earth station conforming to IS:3043-1987 / NEC / IEE complete with brick masonry chamber, CI cover, CI frame, GI watering pipe of 50 mm dia with funnel having 20G GI wire mesh etc. The CI cover frame/ chamber shall be of 1000mm x 500mm x 600mm size. CI manhole cover with frame shall be painted with bitumastic paint, identification of earthpit with yellow paint below the chamber cover, mixtures of charcoal & common salt around electrode including digging of pit up to permanent moisture level but not less than 3 metre depth and back filling. ( value of earth resistance should be less than 1 ohm )
Supply, installation and tesing of 3 meter air terminal with accessories, providing and fixing air terminals as per IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod 4 meter rod: Meets the technical specification according to DIN EN 50164 - 2 (VDE 0815 part 202). Meets the requirement of VDE0185/305 (IEC 62305) 101 VL 4000: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. System consist of Fang Fix with base and clamp on the top air terminal is erected. Fang fix clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. 2 nos of 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors.Concrete, frost-resistant, can be stacked, including all accesories as required for complete installation as instructed by engineer in charge.
Supply and installation of 8mm solid aluminium round conductor: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance, including all accessories as required for complete installation as instructed by engineer in charge. a) Vertical run- Down conductor
Supply and installation of 8mm solid aluminium round conductor: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance, including all accessories as required for complete installation as instructed by engineer in charge. b) Horizontal run-Parapet application
Providing and fixing of Conductor holder for 8mm solid aluminium round conductor: For concrete building Terrace application: Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. With double conductor holder. Filling weight 1Kg (frostresistant concrete). Sleeve made of polyethylene, black, bottom polypropylene, black. Base made of polyamide PA 6, black, UV-stabilised and weather-resistant. Base can be used on almost all roofing felt systems (bitumen, PVC). Conductor holder @ 1 meter distance
Providing and fixing of cross connector/T connector: to route vertical down conductor /mesh formation made of stainless steel/hot dipped galvanised iron with necessary screws etc as required. It should meets the requirements of VDE 0185-305-3 (IEC/ EN 62305-3). And should be tested for minimum Lightning current carrying capacity - H/100 kA. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts
Providing and fixing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. Made of round conductor Rd 8-Alu. Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 highgrade stainless steel. It should be tested for minimum Lightning current carrying capacity - H/100 kA. Conforms to the requirements according to DIN VDE 0185-305 (IEC 62305)
Supply and Fixing Equipotential bonding rail for Lightning Arrestor applications (Test Joint). Equipotential bonding rail for equipotential bonding according to DIN VDE 0100-410/540 and lightning protection equipotetial bonding according to DIN VDE 0185-305. Base plate and cover hood from polystyrene. Colour: Black, UV resistant. Can be used outdoor also. Screw and crossbar made of VA. Capable of carring lightning current 100KA (10/350). Connection options: 7 x single or multi-core conductors to 25mm square or fine core conductors to 16mm square. 1 x round cable Rd 8-10. 1 x flat strip to FL 30 or round cable RD 8-10 including corrosion tapes and all accesories as required for complete installation as instructed by engineer in charge
Supply and laying hot dip Galvanised Steel Flat having 70 microns zinc 30X3 mm thick from earth electrode directly in ground as required. Hot Dip GI strip, corrosion resistant. Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IEC 62305) Zinc coating: 500 g/m square (70 micron coating) Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding including cross connectors and all accesories as required for complete installation as instructed by engineer in charge.
Supply and fixing of PVC trapezoidal 1.5m long ducts including the fastening clamps and all accessories as required.
Providing and fixing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate.
Supply, installation and testing of maintenance free Earthing system as per IS 2309 ,IEC 62305 part3, IEC 60364, IEC 62561 part 2, IS 3043, UL 467 & UL 96 standards. Earthing System comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length (1m (219 20 CU) x 3 nos), having a diameter of 20mm with copper coating thickness of 250 microns with self-coupling bore and peg arrangement (without the need for external coupler) with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA. For obtaining desired length, the number of rods shall be increased and is provided with Universal Clamp (2730 20 VA) made of SS 304 for clamping the cable/flat conductor to the rod. Impact point (219 20 IP) on the bottom rod for easy insertion. Earth enhancing mineral compound (ECS PB 12.5) is used for improving the soil conductivity. Earth enhancing mineral compound shall be so designed and constructed that in normal use their performance is reliable and without danger to persons and the surroundings. The material shall be mineral inert to sub soil and shall not pollute the environment. It shall provide a stable environment in terms of physical and chemical properties and exhibit low resistivity. It shall not be corrosive to the earth electrode itself. The material should have a resistivity less than 0.2 Ohm meter. It should be free from hazardous substances The mineral compound is required to have minimum 12.5 Kg of the total composite. Polypropylene & Polyethylene (UFE)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 170mmx 170mmx 190mm with a weight bearing capacity of 5KN, including all accesories as required for complete installation as instructed by engineer in charge.
MISCELLANEOUS
Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required 20mm dia
Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required 25mm dia
Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.
Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant. 25A 100mA DP RCBO
Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant. 25A 100mA FP RCBO
Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant. 32A 100mA FP RCBO
Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant 40A 100mA FP RCBO
Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant. 63 Amp 16kA FP MCCB with Thermal - Magnetic Release
Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant. 100 Amp 16kA FP MCCB with Thermal - Magnetic Release
Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all acessories required for complete installation etc , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all acessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. Note - Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per latest fire norms One light point controlled by one way switch (at ground floor)
Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all acessories required for complete installation etc , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all acessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. (Note - Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per latest fire norms) Loop wiring for Light point
Supply and fixing of following FP 415V, isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation 32A FP Isolator with enclosure
Supply and fixing of following FP 415V, isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation 50A FP Isolator with enclosure
Supply and fixing of following FP 415V, isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation. 63A FP Isolator with enclosure
Supply, installation, testing and commisioning of following rating TP C curve MCB, 16kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. 6 to 32A TP MCB
Supply, installation, testing and commisioning of following rating TP C curve MCB, 16kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. 40A TP MCB
Supply, installation, testing and commisioning of following rating TP C curve MCB, 16kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant.
RISING MAINS, BBT AND TAP OFF BOXES
Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated Sandwich type, epoxy insulated, compact, sandwitched indoor type (TPN) rising mains on wall, with high conductivity aluminium conductor in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with expansion joints, fire barriers at each floor crossing, copper flexible end connections. end cap etc . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 5 mm copper strip on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The bus duct shall comply with IEC and BS standards. Each bus bar shall be individually insulated by means of Multi layer Class-F Insulation, Each layer shall have withstand breakdown voltage of minimum 6 kV. The insulation material used shall be of minimum Class F (155 deg. C). The routine test certificate as per IS / IEC and type test certificate of identical rising mains shall be furnished including all accesories required for complete installation. 250A Al TPN, 25 kA, IP54 Rising Mains
Supply, installing, connecting, testing and commissioning of following capacity end feed unit suitable for Sandwich type rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The end feed unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of end feed unit shall be furnished. 250 Amp 25kA FP MCCB with Thermal - Magnetic Release
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. Plug-in unit must achieve IP-54 protection. The tap off boxes should not be possible to in sert or withdraw the plug-in box with MCCB ON Condition. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. 125 A 25kA FP MCCB in Tap off box
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. Plug-in unit must achieve IP-54 protection. The tap off boxes should not be possible to in sert or withdraw the plug-in box with MCCB ON Condition. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. 100 A 25kA FP MCCB in Tap off box
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. Plug-in unit must achieve IP-54 protection. The tap off boxes should not be possible to in sert or withdraw the plug-in box with MCCB ON Condition. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. 63 A 25kA FP MCCB in Tap off box
SAFETY EQUIPMENTS
Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.
Supply and providing 6 mm thick and 1 m wide electrical grade chequered type rubber mat to withstand 3.3 kV dielectric strength conforming to IS 5429/1969
Supply and providing First Aid Box.
Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.
Supply & fixing Laminated drawings of electrical lay out, schematic drawing etc on good frame work.
Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for cable duct covering etc.
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold or, duly painted over a coat of primer. Cost inclusive of providing 3 Nos of fire buckes and MS stand frame.
Extra Low Voltage System DATA
Information Outlet RJ 45 - Supply, fixing, fluke testing and commissioning of CAT6 Information Outlets (Key stone) with Shuttered Face plate, Single port, white, jack, suitable PVC / GI Modular Box etc. including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.
Information Outlet RJ 45 - Supply, fixing, fluke testing and commissioning of CAT 6A Information Outlets (Key stone) with Shuttered Face plate, Single port, white, jack, suitable PVC / GI Modular Box etc including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.
CAT6 Cable - Supplying and drawing of Category 6 FRLS cable consists of 4 pairs of solid insulated copper 23AWG, surface/ recessed medium class PVC conduit through wall/tray with all accessories as required for complete installation and as instructed by engineer in harge/consultant and making good all damages made for installation.
CAT 6A Cable - Supplying and drawing of Category 6A FRLS cable consists of 4 pairs of solid insulated copper 23AWG, surface/ recessed medium class PVC conduit through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.
Patch Cable - User Side - Supply, fixing, testing and commissioning of CAT6 Patch Cable - 2 Meter FRLS length etc. of approved make as required for complete installation.
Patch Cable - User Side - Supply, fixing, testing and commissioning of CAT6A Patch Cable - 2 Meter FRLS length etc. of approved make as required for complete installation.
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of CAT6 Patch Cable - 1 Meter FRLS of approved make as required for complete installation.
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of CAT6A Patch Cable - 1 Meter FRLS of approved make as required for complete installation.
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of Single Mode Fibre Patch Cable (LC) Duplex - 2 Meter of approved make as required for complete installation.
Supply and laying of 6 core SM armoured Optical Fibre Cable (OFC) in ground including excavation,road cross, sand cushioning, protective covering and refilling the trench etc as required.
VOICE
Information Outlet RJ 11 - Supply, fixing, testing and commissioning of RJ11 Information Outlets (Key stone) with shuttered Faceplate, single port, white, jack, suitable PVC / GI Modular Box etc. including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.
Cable - Supplying and drawing of following pair telephone cable consists of 0.5 mm dia FR, PVC Compound annealed copper conductor, unarmored telephone cable in surface / recessed medium class FRS PVC conduit through wall/tray with all acessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. 2 Pair Telephone Cable
Cable - Supplying and laying of following pair armoured telephone cable through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. 10 Pair Telephone Cable
krone Box - Supply, erection, testing and commissioning of following pair krone Box with mounting frame,enclosure of ISI grade with lockable front cover with all accessories required for fixing the box with all accessories required for complete installation in wall as directed by the Engineer in charge. 20pair
Supply, installation, testing and commissioning of Basic user phone with necessary connection as required for complete installation as directed by the engineer in charge.
Surge Protection Device For EPABX: Supply, Installation, Testing and commissioning of SPD with enclosure, the surge protection device shall be suitable to protect telephone lines designed to with stand both lightning current and switching surges. Technology: GD tube, Nominal Voltage: 180 V, Pulsed Current (10/350 μs ) Iimp: 1 KA, Nominal Discharge Current (8/20 μs )/phase In: 5KA, Maximum discharge current: 10 KA,Voltage Protection Level(sym)<700V, Response time<1n sec
CLOSED CIRCUIT TELEVISION
Camera for General Area- Dome - Supply, Installation, testing and commissioning of IP based 3.6 mm fixed lens, 2MP resolution, Power Over Ethernet (POE), H.264 / H.265, 1/2.8" Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in false ceiling as required for complete installation as directed by Engineer in charge
Camera for Corridor - Dome - Supply, Installation, testing and commissioning of IP based 2.8/3.6 mm to 9/12 mm verifocal lens, 2MP resolution, POE (Power over Ethernet), H.264 / H.265, 1/2.8" Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in false ceiling as required for complete installation as directed by Engineer in charge.
Camera for Lift - Dome - Supply, Installation, testing and commissioning of IP based 2.8 mm fixed lens, 2MP resolution, Power Over Ethernet (POE), H.264 / H.265, 1/2.8" Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in false ceiling as required for complete installation as directed by Engineer in charge.
Camera - Bullet - Supply, Installation,testing and commissioning of Varifocal Bullet Camera with 2 MP, Power Over Ethernet (POE), H.264 / H.265, built-in IR LED, 2.8/3.6 mm to 9/12 mm, 20 to 30 meters IR range, IP 66 with all connectors and necessary accessories for mounting in false ceiling/True Ceiling as required for complete installation as directed by Engineer in charge.
Network Video Recorder with Storage: Supply, installation, testing and commissioning of Channel Network Video Recorder with Recording Storage space server for 30 days, Supports 32 channels 720 P resolution video recording at real time, NVR ONVIF supporting, Recording resolution of Max 4 MP, should support dual video HDMI output, H.265,H.264 at real time. Video storage expansion for recording for complete installation with all accessories as required and directed by engineer in charge. (Consider the sufficient HDDs for 720p @ 20 FPS for 30 days continues recording for all channels). Storage calculation details shall be submitted.
LED Display - Supply, installation, testing and commissioning of 43 inch full HD LED display for video wall arrangement for 24 x 7 Setup including necessary connection, HDMI cable, rating tray etc. as required for complete installation with all accessories as required and directed by engineer in charge.
Supply, installation, testing and commissioning of workstation with Intel I5 or above, 4 GB ram and 1 TB HDD with software for CCTV integration.
PUBLIC ADRESSING SYSTEM
Ceiling Mounted Speaker - Supply, fixing, testing and commissioning of ceiling mount Metal Grille Speakers with inbuilt line matching transformer with power 6W with required accessories for installation as required.
Wall Mounted Speaker - Supply, fixing, testing and commissioning of Cabinet Speakers with inbuilt linematching transformer with power 12W with a volume controller to adjust the volume individually as per the requirement with all accessories for complete installation as required. The volume controller shall be fixed separately as per the site condition for individual control. Cost inclusive of necessary interconnection including conduit, connection wire etc. required for complete installation.
Mixing Amplifier - Supply, fixing, testing and commissioning of 240 Watts Mixer Amplifier with necessary jacks and cable for connections and interconnection with all accessories required for installation as required.
Power Amplifier - Supply, fixing, testing and commissioning of Power Amplifier of 240 Watts with necessary jacks and cable for connections and interconnection with all accessories required for installation as required.
Power Amplifier - Supply, fixing, testing and commissioning of Power Amplifier of 480 Watts with necessary jacks and cable for connections and interconnection with all accessories required for installation as required.
Controller - Supply, fixing, testing and commissioning of Master zone controller with routing zone capacity of additional 6 zones with all accessories and necessary connections including necessary cables and installation. The work also include integration with Fire Alarm System (FAS) including to play the pre-recorded message in case of fire and evacuation.
Call Stations - Supply, fixing, testing and commissioning of 6 Zone Calling Station with mic as per the drawing as required for complete installation.
Audio/Video player - Supply, installation, testing & commissioning of Audio/Video player with USB option with all accessories like jacks and codes for complete installation as required as directed by the Engineer in charge.
Speaker Cable - Supplying and drawing of 2 Core, Twin Twisted, ATC tinned copper, overall sheathed, Armoured Speaker cable, 16 AWG for speakers through surface / Tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.
ACTIVE COMPONENTS RACKS AND ACCESSORIES
Supply, Installation, Testing and installation of Cat - 6, 24 port fully loaded patch panel with necessary cable manager for routing the cable inside rack with all accessories required for complete installation as required as directed by the engineer in charge.
Supply, Installation, Testing and Commissioning of Cat - 6, Non POE 24 port 10/100/1000 Mbps, layer 2, switch with 4 Stack/upstream port on SFP , Stacking cable, rack mounting brackets, input connector shall be as per IEC-320-C14 with all accessories required for complete installation as required as directed by the engineer in charge.
Supply, Installation, Testing and Commissioning of Cat - 6, POE 24 port 10/100/1000 Mbps, layer 2, switch with 4 Stack/upstream port on SFP, Stacking cable, rack mounting brackets, input connector shall be as per IEC-320-C14 with all accessories required for complete installation as required as directed by the engineer in charge. The switch should be capable to provide sufficient power budget to IP cameras as per the requirement.
Supply, installation, testing and commissioning of 24U Rack with Front glass door, Rear Perforated door with handle Lock & key. Front/Rear 16U mounting angles, top, bottom open, RAL 9005, including necessary exhaust / circulation fan with all other accessories required for complete installation as directed by the engineer in charge.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thicknessDetails of cost for 30 metres
Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray "bends " ( galvanisation not less than 50 microns) with perforation notmore than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
Supply, Installation, Testing and Commissioning of 6 port Light Interface Unit (LIU) / Fiber Patch Panel, rack mountable with mounting brackets, loaded with Adapters, Couplers Single Mode (SM) LC type pigtails with splicing with all accessories required for complete installation as required as directed by the engineer in charge.
Supply, Installation, Testing and Commissioning of SMF 1G Fiber SFP modules.
HVAC system INVERTER SPLIT UNITS
Supply, Installation, testing and commissioning of inverter type split air cooled Air-conditioners each complete with rotary/scroll compressor, air cooled condensor, GSS casing, filters, cooling coils, fan motors, insulated copper refrigerant piping as per drawing, control wiring, refrigerant controls and accessories, including MICRO-PROCESSOR CONTROL with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with Micro- processor control panel for each machine. Rate quoted shall include GI painted frame works for outdoor units, all associated works & making good of civil work's. Refrigerant shall be R410A / R32. Price shall inclusive of installation, commissioning, Refrigerant piping as per Drawing. 1 TR Hiwall Split unit
Supply, Installation, testing and commissioning of inverter type split air cooled Air-conditioners each complete with rotary/scroll compressor, air cooled condensor, GSS casing, filters, cooling coils, fan motors, insulated copper refrigerant piping as per drawing, control wiring, refrigerant controls and accessories, including MICRO-PROCESSOR CONTROL with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with Micro- processor control panel for each machine. Rate quoted shall include GI painted frame works for outdoor units, all associated works & making good of civil work's. Refrigerant shall be R410A / R32. Price shall inclusive of installation, commissioning, Refrigerant piping as per Drawing. Minimum 1 .25 TR capacity 4 way cassette Split unit
Supply, Installation, testing and commissioning of inverter type split air cooled Air-conditioners each complete with rotary/scroll compressor, air cooled condensor, GSS casing, filters, cooling coils, fan motors, insulated copper refrigerant piping as per drawing, control wiring, refrigerant controls and accessories, including MICRO-PROCESSOR CONTROL with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with Micro- processor control panel for each machine. Rate quoted shall include GI painted frame works for outdoor units, all associated works & making good of civil work's. Refrigerant shall be R410A / R32. Price shall inclusive , installation, commissioning, Refrigerant piping as per Drawing 2 TR Hiwall Split unit
DOUBLE SKIN DX COIL AIR-HANDLING UNITS WITH VFD DRIVEN PLUG FANS AND THERMAL BREAK
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminum fins (min. 10 fins per inch) and required number of rows deep. TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. "Thermostat including all necessary cablig, Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. AHU with heater banks shall comprise of strip heatersof mentioned capacity comprising -thermostat, humidistat, safety thermostat, contactors, Control panel to link the dx outdoor unit Controls & control Wiring. control cabling between indoor/AHU & out door units, AHU Kit, communication cables etc. Including finishing of the slabs or any opening etc good as same. Notes: Fine filter efficiency 99.9% down to 5 micron. AHU static = 65 mm 7 TR, 3200 Cfm, 6.4 Sq.ft / 6 Row (DX COOLING COIL) Double skin Horizontal Ceiling suspended AHU (VFD driven) with mixing box, 10 micron pre filters , 5 micron fine filters & Thermal break profile
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminum fins (min. 10 fins per inch) and required number of rows deep. TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. "<br>"Thermostat including all necessary cablig, Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. AHU with heater banks shall comprise of strip heaters of mentioned capacity comprising -thermostat, humidistat, safety thermostat, contactors, Control panel to link the dx outdoor unit Controls & control Wiring. control cabling between indoor/AHU & out door units, AHU Kit, communication cables etc. Including finishing of the slabs or any opening etc good as same. Notes: Fine filter efficiency 99.9% down to 5 micron. AHU static = 65 mm "<br>"9 TR, 3600 Cfm, 7.2 Sq.ft/6 Row (DX COOLING COIL) Double skin Horizontal Ceiling suspended AHU (VFD driven) with mixing box, 10 micron pre filters , 5 micron fine filters &Thermal break profile
CONDENSING UNIT(OUTDOOR UNIT)
Supply Installation testing and commissioning of Air-cooled condensing unit with scroll-compressor consisting of microprocessor based control panel, sufficient refrigerant, vibration isolator outdoor unit platform suitable for the unit. Cabling from nearby isolator etc Refrigerant shall be R410A / R32.<br>Condensing unit of minimum 7 TR capacity
Supply Installation testing and commissioning of Air-cooled condensing unit with scroll- compressor consisting of microprocessor based control panel, sufficient refrigerant, vibration isolator outdoor unit platform suitable for the unit. cabling from nearby isolator etc Refrigerant shall be R410A / R32. Condensing unit of minimum 8.5 TR capacity
PIPING
Liquid line - Refrigerant piping with 19 mm thick nitrile rubber insulation and with glass cloth & foaster painting.
Suction line - Refrigerant piping with 19 mm thick nitrile rubber insulation and with glass cloth & foaster painting.
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same.
SHEET METAL WORK
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 375×375
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 RD:375X375
Supply, Fabrication, installation and testing of folloeing size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification. 300 mm dia
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 450X450X400H
SITC of Factory made fresh air dampers with louvers and control lever, filter and bird mesh etc as required. (as per drawing)
Supply, fix, balance and commissioning of louvre type smooth supply air duct dampers made of extruded aluminium linkage, lever, brass bushings complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges, fixing arrangement etc, as per specifications. Al. volume control duct damper
Supply and fix 1 1/2 hour fire rated fire dampers air ducts (main line) with fusible link & micro switch to shut of corresponding AHU (including control cable.)
DUCT INSULATION AND LINING
Thermal insulation: Supply & fixing of 8 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3. Moisture Diffusion Resistance Factor or ‘μ’ value of the base insulation material shall be minimum 10,000 & K value - Minimum 0.033 @ 0 deg C
Acoustic insulation: Supply & fixing of 10 mm thick Class 1 acoustic nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 140- 180kg/m3
UNDER DECK INSULATION - FOR ICU, OPERATION THEATRE, MRI, CT, ISOLATION ROOMS: Supply & fixing of 9 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3
Roof(inside) insulation for exposed slabs/walls: Supply & fixing of 12 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3
VENTILATION SYSTEM
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum. 80 CFM
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum. 350 CFM
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum.
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum.
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum.
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum.
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum.
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum.
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
Supply, Fabrication, installation and testing of the flexible ducting, complete with connecting rings, duct supports, Plenum etc as per standards and specification.
Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Fire Protection & Life Safety System Fire Pumps, Control Panel and Pipes
MAIN PUMP - Supply, installation, testing and commissioning of Horizontal long coupled End Suction Fire Hydrant Pump Set: Electrical Driven, Capacity: 2280 LPM at 70 Meter Head, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, High Efficient IE-3 rated, Squirrel Cage Induction Electric Motor, Suitable HP, 3Ph, 50 Hz, 2900/3000 RPM, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement and nececssary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.
SPRINKLER PUMP - Supply, installation, testing and commissioning of Horizontal long coupled End Suction Fire Sprinkler Pump Set: Electrical Driven, Capacity: 2280 LPM at 70 Meter Head, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, High Efficient IE-3 rated, Squirrel Cage Induction Electric Motor, Suitable HP, 3Ph, 50 Hz, 2900/3000 RPM, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement and nececssary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.
JOCKEY PUMP - Supply, installation, testing and commissioning of Jockey Pump: Electrical Driven, Capacity: 180 LPM at 75 Mtrs. Head, Vertical Multi Stage Inline Pump with S.S Impeller, Mechanical Seal, and with High Efficient IE-3 Rated Squirrel Gauge Induction Motor, Suitable HP, 3Ph, 50 Hz, 3000 RPM, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement and nececssary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.
DIESEL PUMP - Supply, installation, testing and commissioning of Stand By / Back Up Fire Pump, Horizontal long coupled, End Suction Pump, Engine Driven, suitable for Automatic operation and consisting of the following and complete in all respect as required; Capacity: 2280 LPM at 70 Meter Head conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, coupled to High Efficient Radiator Cooled Diesel Engine, Suitable HP, 2150 RPM, and with Control Panel with Auto Starting Facility, by activation of concerned Pressure Switch and thro. 12V/24 V Electric Starter, Battery of adequate rating and with Battery Charger, Battery Leads, Diesel Tank for 6 hrs operation, exhaust pipe extended up to 1 mtr outside pump house, duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, complete with necessary civil foundation, foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, and all other necessary fixing accessories, all as per Technical Specifications.
Supply, erection, commissioning of additional length of Exhaust Pipes with long radius bend from silencer with necessary clamps, fixtures, civil works and thermal insulation with 50 mm thick rock wool and with 1.0 mm thick aluminum sheet cladding of following adequate size including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. The horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe of required height shall be provided according to latest CPCB norms
Supply, installation, testing and commissioning of Pressure Switches with pressure rating suitable for Fire Pumps, with a differential of 0.2 to 1.6 Bar, as per Technical Specifications.
Supply, installation, testing and commissioning of Diaphragm Pressure Vessel, 112 Ltrs Capacity, 15 Bar Working Pressure at a maximum flow rate of 2280 LPM. The vessel shall be with replaceable interior air cell, metallic outer shell, base, air release valve etc, all as per Technical Specifications.
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 25 mm
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 32 mm
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 40 mm
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 50mm
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 65 mm
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 80 mm
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 100 mm
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 150 mm
Hydrant System,Piping, Valves and Accessories
Providing, fixing, pressure testing and commissioning of Under Ground Fire Hydrant Pipe Work with Ductile Iron Pipes conforming to IS: 8239 / BIS EN: 545, Working Pressure 16 Bar (Class K-9), with Socket and Spigot. Pipe Fitting shall of Class K12. All the Pipes and Fittings shall with following protective coats / lining as per Standards and Manufacturer’s technical details. i. Internal lining with Cement Mortar ii. External Coating with a layer of metallic zinc + a layer of and bitumen coating. iii. Further protection with loose & air / water tight polythene sleeves.The cost for underground pipe work shall be inclusive of earthwork excavation and providing Masonary / PCC / RCC Thrust Blocks as per requirement. Dia - 150mm
Providing, fixing, pressure testing and commissioning of Under Ground Fire Hydrant Pipe Work with Ductile Iron Pipes conforming to IS: 8239 / BIS EN: 545, Working Pressure 16 Bar (Class K-9), with Socket and Spigot. Pipe Fitting shall of Class K12. All the Pipes and Fittings shall with following protective coats / lining as per Standards and Manufacturer’s technical details. i. Internal lining with Cement Mortar ii. External Coating with a layer of metallic zinc + a layer of and bitumen coating. iii. Further protection with loose & air / water tight polythene sleeves. The cost for underground pipe work shall be inclusive of earthwork excavation and providing Masonary / PCC / RCC Thrust Blocks as per requirement. Dia - 100mm
Providing, fixing, pressure testing and commissioning of Under Ground Fire Hydrant Pipe Work with Ductile Iron Pipes conforming to IS: 8239 / BIS EN: 545, Working Pressure 16 Bar (Class K-9), with Socket and Spigot. Pipe Fitting shall of Class K12. All the Pipes and Fittings shall with following protective coats / lining as per Standards and Manufacturer’s technical details. i. Internal lining with Cement Mortar ii. External Coating with a layer of metallic zinc + a layer of and bitumen coating. iii. Further protection with loose & air / water tight polythene sleeves. The cost for underground pipe work shall be inclusive of earthwork excavation and providing Masonary / PCC / RCC Thrust Blocks as per requirement. 80 mm.
Providing, fixing, testing and commissioning of Ball Valve, PN-16 Forged Brass & Nickel / Chrome Plated, conforming to IS: 9890, UL Listed and FM approved with Screwed Female Ends to BS:21, and with noncorrosive handle / lever, all as per Technical specification. including necessary accessories and connections. 50 mm
Providing, fixing, testing and commissioning of Ball Valve, PN-16 Forged Brass & Nickel / Chrome Plated, conforming to IS: 9890, UL Listed and FM approved with Screwed Female Ends to BS:21, and with noncorrosive handle / lever, all as per Technical specification. including necessary accessories and connections. 25 mm
Providing, fixing, testing and commissioning of Butterfly Valve, PN-16, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. 80 mm.
Providing, fixing, testing and commissioning of Butterfly Valve, PN-16, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. 100 mm.
Providing, fixing, testing and commissioning of Butterfly Valve, PN-16, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. 150 mm
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 150mm
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc Dia - 100mm
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 80mm
Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with required companion flanges nuts, bolts etc. complete. 150mm.
Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with required companion flanges nuts, bolts etc. complete. 100mm.
Providing, fixing, testing and commissioning of Gun Metal Non Return Valve, PN-16, Vertical / Horizontal Type , as per final requirement, conforming to IS: 13095 with nuts, bolts etc. complete. 80mm.
Providing, installing and commissioning C.I.flanged "Y" type Strainer with SS mesh, suitable flanges, nuts, bolts,gaskets etc. complete. Dia - 150mm
Providing and fixing Ductile Iron Gate Valve, Rising Spindle, OS & Y Type, Body: ASTM A536, 65-45-12, Flanged to BS5163, PN16, UL Listed & FM Approved with Tamper / Supervisory Switches and with required flanges, rubber insertions, bolts, nuts, Washers etc. complete. Dia - 150mm
Providing and fixing Ductile Iron Gate Valve, Rising Spindle, OS & Y Type, Body: ASTM A536, 65-45-12, Flanged to BS5163, PN16, UL Listed & FM Approved with Tamper / Supervisory Switches and with required flanges, rubber insertions, bolts, nuts, Washers etc. complete. Dia - 100 mm
Providing and fixing Ductile Iron Gate Valve, Rising Spindle, OS & Y Type, Body: ASTM A536, 65-45-12, Flanged to BS5163, PN16, UL Listed & FM Approved with Tamper / Supervisory Switches and with required flanges, rubber insertions, bolts, nuts, Washers etc. complete. Dia - 80 mm
Supply, installation, testing and commissioning of 4" dia. Bourdon Type Pressure Gauge, with ISI Mark or of equivalent International Standards.<br>Weather / Water Proof Type, Pressure Range: 0 to 16 Bar, with Stainless Steel Shut off Cock, Syphone Pipe, Snubber etc.
Supply, installation, testing and commissioning of Fire Hydrant Valve, bearing to ISI:5290 Type-A mark, Stainless Steel-304 body with 63mm. oblique instantaneous single outlet, 75mm. N.B. flanged inlet, Stainless Steel -304 spindle, complete with PVC blank cap, G.I. chain etc.
Supply, installation, testing and commissioning of Manual Swing Type Fire Hose Reel Complete Set with heavy duty drum / reel, 19mm. dia. x 30Mtr. long 2-ply polyester yarn braided /rubber braided pressure hose, Red Coloured, heavy duty nylon on/off jet/spray nozzle, 22mm dia isolating valve and all other necessary fixing accessories including Fabrication and Erection of M.S. Support, as per requirement, for Fixing the Fire Hose Reel Set.
Supply, installation, testing and commissioning of Fire Hose, RRL hose jacketed with circular woven synthetic fiber. conforming to IS: 636:88, with Working Pressure 14 Kg/Cm2, Proof Pressure 22 Kg/Cm2 and Burst Pressure 38 Kg/Cm2. The Fire Hose shall be with IS: 636 Type-A marking and 63mm. dia.x15Mtr.long with pair of 63mm. male and female instantaneous couplings, Stainless steel-304, having IS: 903 mark and duly S. S. wire wounded. The hose shall be rolled and hung to suitable M. S. support in the Fire Station.
Supply, installation, testing and commissioning of Branch Pipe, Stainless Steel-304, short type, with 63mm. male instantaneous inlet, male threaded outlet, fitted with 16mm. bore nozzle, having IS: 903 mark.
Supply, installation, testing and commissioning of Fire Brigade Inlet Breeching, C.I. body, having 3 Gunmetal, 63mm. male instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 3 nos. of rubber blank caps and G.I. chains.
Supply, installation, testing and commissioning of Fire Brigade Draw Off Outlet C.I. body, having 3 Gunmetal, 63mm. female instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 3 nos. of rubber blank caps and G.I. chains.
Supply and fix at site in position Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement.
Supply and fix at site in position Weather proof Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement.
Providing and fixing sight glass assembly of brass body and brass ball with chrome plated, steel handle, PN16 or above, UL Listed & FM Approved. Test and drain valve shall be with compact 3 position ball valves with drain orifice having K-factor 5.6 and a sight glass. 3 positions consist of OFF, TEST and DRAIN. Test and drain valves shall be provided for test as well as express drain functions in wet sprinkler systems with grooved end connection ends. The Test and Drain Valve shall be in Brass ASTM B584 material of construction. These have integral tamper resistant sight glass.
Supply, installation, testing and commissioning of Air Release Valve Gunmetal, conforming to IS 903:1993, having rubber ball with sealing seat and with 25mm. BSP threaded male inlet, including isolation valve and necessary accessories and connections.
Providing, fixing, testing and commissioning of Standard Coverage, Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings. Upright Type, 68 Degree C Rating.
Providing, fixing, testing and commissioning of Standard Coverage, Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings. Pendant Type, 68 Degree C Rating.
Providing, fixing, testing and commissioning of Standard Coverage, Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings. Pendant Type, 79 Degree C Rating.
Providing, fixing, testing and commissioning of Extended Coverage, Quick Response Horizontal Side Wall Type Automatic Fire Sprinkler, 68 degree, K- Factor: 5.6 with necessary accessories and fittings. The Fire Sprinklers shall be UL listed.
Supply, installation, testing and commissioning of Hydraulically Operated Fire Sprinkler Alarm Valve (Installation Control Valve), Grooved End, UL Listed / FM approved, complete with Constant Pressure Trim Assembly, Water Motor Gong, control valves, pressure switch, pressure gauges etc. including all necessary fixing accessories. 150mm. Size
Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with 16 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System., all as per Technical Specifications. The control cabling from flow switches to concerned Module shall be measured with proposed Fire Alarm System. Dia - 150mm
Providing, Fixing, Testing and Commission Flexible Sprinkler Hose of adequate size; UL Listed, FM Approved, 25mm. (1") BSP Male Inlet, 15mm. (1/2") NPT Female Outlet, Braided, Working Pressure 13.8 Bar, length: 1500 mm, and with all connecting systems and accessories.
Providing & Fixing 2 Piece Chrome Plated Friction Fit recessed escutcheon for pendant sprinklers, as per requirement.
Intelligent Addressable Fire Alarm System
Supply, install, test and commission Intelligent Addressable Fire Alarm Control Panel (MCP) as per the technical specification and not limited to having Visual Display Unit (VDU) preferably 640 character LCD display with Battery Back up for 24 hours for normal operation and 1 hours on alarm condition. The control panel, battery charger etc, shall be UL listed approved. The panel / panels should be equipped with Loop Cards of adequate capacity as per manufacturer reccomendation to incorporate the devices and detectors for this project considering 20% spare capacity in each loop. The panels shall be networked together (in case of more than a panel) and capable of networking with other compatible panels. The panel should be expandable to add another Loop card.
Supply, install, test and commission Intelligent Addressable Network Repeater Panel (NRP) with minimum Color display, mapping minimum 2,00,000 points on network. This NRP shall act as an independent node communicating on the peer to peer network and shall not be dependent on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of NRP operation. The Unit shall be complete in all respect and the Cost of Panel shall inclusive of Network Communication Module(s) (NCM), for networking with the Main Fire Alarm Panels.
Providing, fixing test and commission Intelligent Addressable Manual Call Station Point with addressable module that monitors and reports contact status, etc
Providing, fixing, test and commission Intelligent Addressable Weather / Water Proof / Corrosion Resistant type Manual Call Point having an integrally mounted addressable module that monitors and reports contact status, IP67 rated, complete
Providing, fixing, test and commission Conventional Type Horn/Strobe rated at 82 dB @3Mtr. for audible annunciation and 75Candela flashing at 1Hz. for visual indication.
Providing, fixing, testing and commission Intelligent Addressable Input / Monitor Module, for interface with Flow Switches, Fire Pumps, Supervisory Switches, Alarm Valve, Water Tank Level etc.
Providing, fixing, testing and commission Intelligent Addressable control / Relay Module, as per specification for interface with Lift Panel, Water Curtain Partition, AHUs, Ventilation System, Smoke Management System, Power Distribution, Public Address System etc.
Providing, fixing, test and commission Intelligent Addressable Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected, all as per technical specifications.
Supply, laying, testing and commissioning o 2Core x 1.5 mm2 FRLS Armoured Cables with Red Colour / Finish.
Fire Extinguishers
Supply, installation, testing & commissioning of Portable Fire Extinguisher as per BIS 2190 and IS: 15683:2018 and with relevant ISI Stamping/Marking. ABC Dry Chemical Store Pressure Type - 4 kg
Supply, installation, testing & commissioning of Portable Fire Extinguisher as per BIS 2190 and IS: 15683:2018 and with relevant ISI Stamping/Marking. ABC Dry Chemical Store Pressure Type - 2kG
Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking. CO2 - 4.5Kg.
Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking. CO2 - 2.0 Kg.
Clean Agent Modular Type Ceiling mounted Fire Extinguisher 5 Kgs Capacity made of Mild Steel Body of 1.6 mm thickness with pressure gauge, refillable device and safety release device CE Certified Brass valve suitable for A, B and C Classes of Fire complete with Charge of Clean agent (Gas) is also known as HFC Blend A, It is a blend of Hydro Fluoro carbon and organic detossificant essence P26. The sprinkler body will comprise of temperature sensitive quartsoid bulb of temperature rating of 680. The cylinder will be supplied with a proper mounting arrangement to mount it on the ceiling. The Extinguisher shall be externally epoxy powder coated as per IS: 5 Color Shade No. 538 (For Server room) -5 Kgs
FIRE Signages
Fire Exit Light, Laser type, with High Glow LED, size: 12” x 6” Size, Ceiling Mounting type with hanging clamps, on/off switch, Red/ Green Colour option, power consumption: 18 Watt, with 2 Hr. battery backup.
Supply and install in position following Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories required for complete installation as directed by the Engieer in charge.<br>Signage Printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.25cm. height letters in red with white back ground. The size of the board shall be 25 x 30 Cm. and shall be fixed at the height of 2Mts. from finished floor near Manual Pull Stations.
Supply and install in position following Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories required for complete installation as directed by the Engieer in charge.<br>Floor Identification Signage (ie, GROUND FLOOR, FIRST FLOOR, etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 Cm. with contrasting colour from back ground. Size shall be 15cm x 30cm.
Supply and install in position following Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories required for complete installation as directed by the Engieer in charge.<br>Floor Identification Signage (MAIN STAIRCASE, FIRE STAIRCASE, FIRE ASSEMBLY POINT, PUMP ROOM, FIRE CONTROL ROOM, ELECTRICAL ROOM, FIRE LIFT, PASSENGER LIFT Etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 Cm. with contrasting colour from back ground. Size shall be 15cm x 30cm.
Supply and install in position the Signage "FIRE ORDER" it should contain the matter specified in the technical details on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of 2' x 3'.
Talk back system
od190356/2021_2022 : Supply, laying, testing and commissioning o 2Core x 1.5 mm2 FRLS Armoured Cables with Red Colour / Finish.
Supply, installation, testing and commisioning of Public Address speaker with talk back facility 6 Watts with L M T and call switch, made out of powder coated CRCA sheet, wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting.
MISCELLANEOUS ITEMS
FIRE SEALANT for Electrical / ELV / FAS Shafts - Providing High performance intumescent firestop sealant FS One Max that helps protect combustible penetrations for up to 2 hours fire rating in accordance to UL 1479 (American)<br>standards. Surface burning characteristics according UL 723 (ASTM E84-96). Flame spread index 0 and smoke development index 5. The sound transmission classification for this product according ASTM E 90-99 is 56 (STC Rating). It High is mold and mildew resistant and the performance is Class 0 according ASTM G-21. Movement capability approx. 5% (ISO 11600) and the average volume shrinkage is 24% according ASTM C1241. The sealent shall meets LEED requirements for indoor environmental quality credit (4.1 and 4.2) with a VOC content of 9 g/l. product should also Seismic tested on mechanical performance, smoke and fire-ratings. Firestop installation should be done by trained applicators (HAFSC) and in accordance with Hilti guidelines. Applicator needs to provide complete installation report through Software CFS DM for inspection purpose.
FIRE SEALANT for HVAC / MGPS Shafts - Providing Acrylic Firestop Sealant in gaps between periphery of the ducts to provide minimum 2 hours fire rating when subject to the test conditions of UL 2079 standards. The product shall be age tested as per DafStb guidelines. Sealant should provide sufficient MAF, water and gas tight seal. Sealant shall also provide airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation. Sealant shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be UL listed & classified and shall bear the UL and FM approval logo on the packing. Firestop installation should be done by trained applicator (HAFSC) and in accordance with Hilti guidelines. Applicator needs to provide complete installation report through Software CFS DM for inspection purpose.
FIRE SEALANT for Electrical / ELV / FAS Shafts - Providing High performance intumescent firestop sealant FS One Max that helps protect combustible penetrations for up to 2 hours fire rating in accordance to UL 1479 (American) standards. Surface burning characteristics according UL 723 (ASTM E84-96). Flame spread index 0 and smoke development index 5. The sound transmission classification for this product according ASTM E 90-99 is 56 (STC Rating). It High is mold and mildew resistant and the performance is Class 0 according ASTM G-21. Movement capability approx. 5% (ISO 11600) and the average volume shrinkage is 24% according ASTM C1241. The sealent shall meets LEED requirements for indoor environmental quality credit (4.1 and 4.2) with a VOC content of 9 g/l. product should also Seismic tested on mechanical performance, smoke and fire-ratings. Firestop installation should be done by trained applicators (HAFSC) and in accordance with Hilti guidelines. Applicator needs to provide complete installation report through Software CFS DM for inspection purpose.
Length of Puddle Flanges, shown, below are tentative only. The actual lengths may change as per final site conditions. 100mm.dia, 1050mm. Long.
Length of Puddle Flanges, shown, below are tentative only. The actual lengths may change as per final site conditions. 150mm.dia, 700mm. Long.
Constructing masonry Valve Chamber in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice / gate valve, including all supports for fixing valve, with Heavy Duty C.I. cover and frame, i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design Internal Size: 60 x 60 x 75cm, deep
ABM Electricals
Imperial Engineering Company
UNIVERSAL MEP PROJECTS & ENGINEERING SERVICES LIMITED
Bidder Name
Allies Fire Systems Pvt Ltd
ABM Electricals
Imperial Engineering Company
UNIVERSAL MEP PROJECTS & ENGINEERING SERVICES LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .