Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹27.9 L+₹2.6 L (10.3%)Rejected-Finance 45 PIR BABA TARUSHAW ROAD HALWARA AD LUDHIANA 141106 | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹30.9 L+₹5.6 L (22.2%)Rejected-Finance V P O BOPARAI KALAN DISTT LUDHIANA 141422 PB | LUDHIANA | LUDHIANA | PUNJAB | 141422 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹32.4 L+₹7.1 L (28.3%)Rejected-Finance KHATA NO 254 529 KHASRA NO 364 2 MIN PREET NAGAR A GALI NO 2 HARERI ROAD OPP STAR STUDIO HERARI SANGRUR | SANGRUR | SANGRUR | PUNJAB | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹37.9 L+₹12.6 L (50.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
19 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Halwara
GE (AF) Halwara
REPAIR TO ROOFING, SHUTTERS, POST CONSTRUCTION ATT, PERIODICAL SERVICES AND VARIOUS MISC WORK TO CERTAIN BUILDINGS OF WSAS IN TECH AREA AT AF STN HALWARA
2023_MES_596942_1
GE/HAL-16/2023-24
Open Tender
Civil Works
Item Rate
273 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY a(i)
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹90,000
Yes
23 Jun 2023
20 May 2023
21 Jun 2023
20 May 2023
19 Jun 2023
5 Jun 2023
Amount
Hacking out broken glass (any size shape, thickness, quality or description) from wooden/metal frame glazed with putty or fixed with beads having area not exc 0.50 sqm in each pane complete all as specified
Demolition of cement concrete (unreinforced) in ground floors and paving’s n exc 15cm thickness below or above ground level and removing the same out side MoD land complete all as specified and directed.
Dismantling floor hearth or wall tiles including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises of MoD complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified.
Dismantling AC/fibre glass translucent corrugated or semi corrugated sheet including ridges, hips, valley etc of any description and thickness in roof coverings complete all as specified and directed.
Dismantling plain or corrugated steel sheets of any gauge, thickness in any position complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall and applying two coats of exterior acrylic emulsion paint in camouflage pattern, using minimum 3 different approved tint/ colour as approved by GE complete all as specified.
M&L for preparation of old plastered surfaces of wall and applying two coats of distemper oil emulsion complete all as specified.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for bircks works with sub class 'B' bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed .
Taking down cement plaster or cement lime plaster on brick walls etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified.
M&L for 15mm thick rendering in cement mortar 1:6 finished even and fair without using extra cement complete all as specified and directed.
M&Lfor rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick on fair faces of ceiling in cement mortar 1:3 finished surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of exterior acrylic emulsion paint over a coat of primer in camoflage pattern , using minimum three different approved tint/ colour as approved by GE complete all as specified .
M&L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of primer over birla putty complete all as specified and as directed.
M&L for preparation of new plastered surface of wall and applying three coat of white wash complete all as specified and as directed.
All as per Sl item No 18 above but on ceiling surfaces
Dismantling wrought iron work or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-290 (Gde E-165) complete all as specified and as directed
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixing with self taping screws complete all as specified and as directed
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F in repair steel rolling shutters with ball bearing, guide channel as specified including top covers, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete push or pull or manual type having thickness of laths 1.00 mm including taking down/ dismantling of unserviceable rolling shutter complete all as specified and directed.
M&L for preparation of old painted surfaces of steel and iron of any description over 10cm width or girth and applying one coat of synthetic enamel paint of any tint/ colour as approved by GE complete all as specified and directed.
All as per Sl item No 25 above but on wood or wooden based surface
M&L for repairing gear operated , manual operated, rolling shutter and iron door frames/shutters in situ after welding, straighting, easing, adjusting, greasing and making good the disturbed surfaces to match with the adjacent surfaces complete all as specified and directed.
S&F in repair Galvanised 2 strand, steel barbed wire 2.24mm dia barbed wih 2mm dia barbs at 75mm spacing and stranining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc. complete all as directed. Note : Each line wire to be measured.
Cleaning the drainage of width n exc 45 cm and depth 60 cm by removing all debris, vegetable leaves and grass and removing the rubbish outside Mod land complete all as specified and directed by Engineer -in - Charge.
M&L for hardcore of broken brick gauge40 mm to 80 mm , deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed
M&L for 38mm wide plastic dividing strips, 1.5mm thick inserted in position, conform to design all as specified and directed.
M&L for 50 mm thick cement concrete type B-1,1:2:4 (20mm graded aggregate) finished even and smooth without using extra cement complete all as specified and directed
S&F in repair 100mm mild steel CP grating fixed to weep holes of RCC wall complete with two or more rawl plug/screws, making good the adjacent surfaces in cement mortar 1:3 complete all as specified.
Rough excavation n. exc 1.5 m deep and getting out in soft/loose soil complete all as specified
Removing excavated material exc1.5 km but n. exc 5 KM and depositing where directed at a level n. exc1.5 m above the starting point complete all as specified.
Forming embankments including raising (or lowering) earth,spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape,etc., n exc. 3 m high from base
M&L ANTI-TERMITE (post construction) Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors all as specified and directed
M&L ANTI-TERMITE TREATMENT (post construction) along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron all as specified and directed by engineer in charge
M&L for 75mm thick cement concrete type B- 2, 1:2:4 (40mm graded aggregate) as in sub base finished even and fair surface without using extra cement complete all as specified and directed.
M&L sand filling under floors or in foundation all as specified and directed.
M&L for 80mm thick Machine pressed precast concrete interlocking paver block (M-40 Grade) any shape and size confirming to IS 15658-2006 laid over sand cushioning complete all as specified. NOTE :- Sand cushioning shall be measured and paid seperately
S&F in replacement 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
CHOUDHARY ENTERPRISES
Deol Builders
JINDAL AND COMPANY
BEHL AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .