MMPPNA_RIDF_XXXI_25_26_544 Improvement of Road from Kadarpar PHE to Kadarpar Basti (Length-1.60 KM) under Mukhya Mantrir Pakipath Nirman Aachani (MMPPNA) under Mukhya Mantrir Pakipath Nirman Achani (MMPPNA) under RIDF-XXXI of NABARD for the year 2025
2026_PWD_51336_3
CE/DEV/TB/60/2025-26/75 Dtd- 29.01.2026
Open Tender
Civil Works – Roads
Item Rate
365 days
Lakhipur
Please refer Tender Documents
5 documents required · 5 mandatory
₹7,250
₹7.3 L
Yes
CE, PWRD
14 Mar 2026
21 Feb 2026
25 Feb 2026
21 Feb 2026
25 Feb 2026
21 Feb 2026
21 Feb 2026 - 21 Feb 2026
21 Feb 2026
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (i) By manual means (A) In area of non-thorny jungle.
Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 (Manual should be use where machines can not be deployed due to site condition)
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (I) Private Land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. Private Land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Clause 401. II) For Grading II Material
Providing , laying, spreading and compacting stone aggregates of specified sizes to water bound macadam specification including spreading in uniform thickness , hand packing ,rolling with 3 wheels 80-100KN static roller in stages to proper grade and camber, applying and brooming stone screening / binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density as per Technical Specification Clause 405. (3) Grading - III (Screening B). A) By Manual Means-
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage. a) including Edge block/Edge restraints
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm equilateral triangle
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm circular
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixingin position including painting and printing, etc as per drawing and Technical Specification Clause 1703 ii) Ordinary Kilometer Stone (Precast)
(Construction of 2x5x5 Box Cell Culvert) Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side Ordinary soil upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6 [Hand Mixing]
Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203 PCC Grade M 20 Nominial mix (1:2:4)
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204 PCC Grade M 20 Nominial mix (1:2:4)
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 With crushed stone, For nominal mix 1:2:4, Height upto 5 M, R.C.C grade M 20
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11 With Crushed stone
Supplying, fittingandplacingTMT (Fe-500D) reinforcement bar (From Primary Producer:TATA/SAIL/EsserSteel/Jindalsteel/Shyamsteel/RINL)in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Supplying, fittingandplacingTMT (Fe-500D) reinforcement bar . (From PrimaryProducer:TATA/SAIL/EsserSteel/Jindalsteel/Shyamsteel/RINL)in Primary Producer:TATA/SAIL/EsserSteel/Jindalsteel/Shyamsteel/RINL)in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5 Random rubble masonry in case of stone pitching laid with cement mortar (1:5)
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
(Construction of Single opening 1000 mm dia NP3 HPC) Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
PCC M10(1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing and technical specification clause 1109
Laying 1st class bedding on well compacted sand, moorum as per clause 115(ii)Granular bedding
Brik masonry work in cement mortar in foundation of wall complete excl. pointing and plastering as per drawing and technical specification clause 1100(in prop. 1:4)
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B)1000mm dia.
Plastering with cement mortar(1:6) 15mm thick on brick work for substructure as per technical specification
(Open Drain) Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I. In Ordinary soil (i) Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. B. With Natural Gravel I. P.C.C Grade M 10 Nominal mix 1:3:6
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 B. With Natural Gravel I P.C.C grade M15 I) Nominal mix (1:2.5:5)
Plastering with cement mortor (1:4),15 mm thick on Stonework in substructure as per technical specification Clause 613.4 & 1204.
Construction of Bridge (Span=2x12.50 m) Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary soil, Manual Means, (I) Without dewatering (i) upto 3 m depth
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary soil, Manual Means, (I) Without dewatering (ii) 3 m to 6 m depth
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000 mm)
Pile load test on single vertical pile in accordance with IS:2911(Part-IV). a). Initial and Routine load test.
Levelling course for Pile cap
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999.B RCC Grade M25 (I) Using Concrete Mixer
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork Without plasticiser, For height upto 5 m R.C.C. grade M 25, Using concrete Mixer
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.B. RCC M-25 a. Height upto 5.0m
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
Construction of precast R.C.C. railing of M 30 grade aggregate size not exceeding 12mm, true to line and grade, tolerance of vertical railing RCC post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm, leveling adequate spacing between vertical poss for expansion, complete as per drawing and technical specifications
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation).
Drainage Spouts complete as per drawing and Technical specification
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification A) Granular material
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications. Stone/Boulder
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification
Carrying out sub soil Investigation (SSI) for all types of soil (except boring in rock) up to depth of 30m or refusal (N=100) foe each foundation location as per IRC : 78-2000 and submission of SSI report to the Engineer in -Charge for approval. Preparation & Submission of design calculation & Drawing of Foundation , Sub Structure , super structure as per relevant IRC codes and SSI reports, 2(two) copies each of design & drawing of each bridge to be submitted for approval and 8(eight) coipes after approval of competent authority.
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.35 MB
Tendernotice_2.pdf
PDF • 7.98 MB
Tendernotice_3.pdf
PDF • 0.60 MB
BOQ_81677.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .