AGE I Cannanore HQ Hospital kannur PO 670017
Repair and replacement of light fittings with LED lights and repairs to internal wiring and connected items to certain bldgs of Mily Hospital and md accn at Mily station Kannur under AGE (I) CANNANORE.
2022_MES_557400_1
8224
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Cannanore
Class E Category b( i )
8 documents required · 8 mandatory
₹500
Yes
AGE I Cannanore
₹15,000
Yes
3 Jan 2023
13 Oct 2022
17 Nov 2022
14 Oct 2022
14 Nov 2022
27 Oct 2022
14 Oct 2022 - 20 Oct 2022
Amount
Taking down old existing point wiring including switch and sockets carefully, light, fan, socket or power point complete including unserviceable fittings such as switches ceiling roses, pendants, regulators, sockets of any type etc and making good the disturbed surfaces of walls, floors filling up of holes, plastering, white washing distempering etc matching to the existing surface etc. all as directed.
M&L Point wiring complete with 1.5 Sq mm single core PVC insulated unsheathed copper conductor FRLS cable multi stranded 1100 Volt grade drawn through and including non metallic rigid PVC conduit, medium grade concealed and fixed to ceiling/roof etc with necessary fixing accessories such as bend elbow socket etc with fixing material including terminal box made out of 1.22mm thick GI sheet concealed in wall covered with bakalite/plastic laminated sheet top cover of 3mm thick cadmium plated screws with cup washer including 1.5Sqmm single core PVC insulated un sheathed copper conductor FRLS cable multi stranded 1100Volt grade as earth continuity conductor green in colour connected to common earth dolly complete all as specified and as directed for One light/fan/bell point controlled by one switch.
All as per item No 2 here in before but for One 3 Pin, 5 Amps socket on same board with other switches all as specified and directed.
All as per item No 2 here in before but for One 3 Pin, 5 Amps switch socket combination on independent board all as specified and directed.
All as per item No 2 here in before but for controlled by two way switch all as specified and directed.
All as per item No. 2 on here in before but for one 3 pin 15 amp switch socket combination on independent board with 2.5Sqmm unsheathed PVC insulated copper conductor FRLS cable including 2.5 Sqmm PVC insulated copper cable for earth continuity conductor complete all as specified. Note for item No 01 to 06 : Wiring shall be done with proper colour coding as per IE standard.
S & F switch piano flush type, single pole, one way, 5 Amps, 240 volt including connecting up electrically complete all as specified and as directed.
S & F switch bell push, flush type, 240 Volts, single pole, 5 Amps including connecting up electrically all as specified and directed.
S & F switch piano flush type, single pole, two way, 5 Amps, 240 volt including connecting up electrically complete all as specified and as directed.
S & F PVC ceiling rose 65x50mm size, three terminals, polycarbonate, isolated body including connecting up electrically all as specified and as directed.
S & F socket 5pin 5/6 Amps, multipurpose, flush type, non-interlocking type, including connecting up electrically complete all as specified and directed.
S & F socket 5pin 5/15 Amps, multipurpose, flush type, non-interlocking type, including connecting up electrically complete all as specified and directed.
S & F switch piano flush type, single pole, one way, 15 Amps, SP,240 volt including connecting up electrically complete all as specified and as directed.
S& F calling bell electric AC 240V, single pole, ding dong type and connecting up electrically all as specified and directed.
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings nd electrically connecting up all as directed.
S&F stepped type electronic fan regulator, full rotation, 200W, SP, 230V connecting up electricallyall as specified and directed.
Taking down unserviceable fluorescent tube light fittings, Supply and fixing self ballast LED batten extruded theremoplastic body with PC diffuser > 120 degree wide distribution, 4 feet 20 W LED batten 4 feet 20 W, CCT 6500 K of Havells cat part No LHEXAWP7IN1W020 or equivalent in crompton/Bajaj Complete including connection upto ceiling rose with flexible copper twin twisted wire complete and all as specified and directed by Engr-in-Charge.
Taking down unserviceable fluorescent tube light fittings, Supply and fixing in replacement of self ballast LED batten extruded theremoplastic body with PC diffuser > 120 degree wide distribution, 4 feet 18 W LED batten 4 feet 20 W, CCT 6500 K of Havells cat part No LHEXACP7UNIW018 or equivalent in crompton/Bajaj Complete including connection upto ceiling rose with flexible copper twin twisted wire complete and all as specified and directed by Engr-in-Charge.
Taking down unserviceable fluorescent tube light fittings, Supply and fixing in replacement of self ballast LED batten extruded theremoplastic body with PC diffuser in unique square shape > 120 degree wide distribution, 2 feet 9 W of LED batten 2 feet 9 W, CCT 6500 K of Havells cat part No LHEXBLP7IN1W009 or equivalent in crompton/Bajaj Complete including connection upto ceiling rose with flexible copper twin twisted wire complete and all as specified and directed by Engr-in-Charge.
Taking down unserviceable light fittings, Supply and fixing of Recessed/Surface mounting 36W LED luminaire, prewired with white powder coated CRCA housing with LEDs and fully window acrylic diffuser, suitable for 600x600mm E-grid/POP/ false ceiling of Bajaj cat part No BZSSQL36WLEDG54WH or equivalent in crompton/Havells complete with all accessories making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
Taking down old unservicaeble submain wiring any size cable including conduit , batten etc and making good disturbed surfaces of walls, floor ceiling etc. all as directed
Suppply and fixing in replacement submain wiring with using two single core 6.0 Sqmm copper multy stranded conductor PVC insulated and unsheathed (FRLS) cable and one single core 6.0 Sqmm copper multistandred conductor PVC insulated and unsheathed (FRLS) Earth wire using ISI MArked IS 694 1100 volts grade PVC insulated flexible stranded copper conductor wire drawn through with and including medium grade concealed PVC conduit ISI marked not less than 25 mm dia including conduit fitting and accessories complete including cutting cheses in existing wall of any descirption built in cement mortar and making good the disturbed surfaces in cement mortor (1:4) and finishing the surfaces to match with existing surfaces and finish termonatioin with bottle type copper lugs conduit being laid either in ceiling slab or wall or on surfaces or under the frame of the false ceiling including PVC flexible conduit or through wooden partition including clamping arrangement as required complete all as sepcified and directed . (Note:- Three Run of 6.0 Sqmm cable and conduit of suuitable size shall be measured as one unit).
S&F in replacement of MCB SP 6-32 Amps breaking capacity 10 KA 'B' series 240 volts 50 Hz complete all as specified and directed.
S&Fin repacement of MCB SP&N 40 Amps breaking capacity 10 KA 'B' series 240 volts 50 Hz complete all as specified and directed.
S & F MCB TPN, 430 Volt, 63Amps, breaking capacity 10 KA B serious including electrically connecting up using wiring lugs all as specified and directed.
S&F in replacement of double door MCB distribution board sheet steel powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 6 Ways complete all as specified and directed.
S&F in replacement of double door MCB distribution board sheet steel powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 8 Ways complete all as specified and directed.
S & F sheet metal enclosure factory made for MCB DB, TPN 4 way with 200 Amps bus bar, 240 Volt, double door type, fixed/flushed on wall including electrically connecting up and taking down old unserviceable DB complete all as specified and directed.
S & F in replacement of LED Lamp 15 Watt complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Modular switch 6 A, 1 module, including connecting up electrically complete all as specified and directed.
S & F in replacement of Modular switch 16 A, 1 module, including connecting up electrically complete all as specified and directed.
Modular Bell push 6A 1 module,including connecting up electrically complete all as specified and directed.
S & F in replacement of Modular Socket 6A - 2/3 pin combined 2 module, including connecting up electrically complete all as specified and directed.
S & F in replacement of Modular socket 6A/16A - 2/3 pin combined, 2 module, including connecting up electrically complete all as specified and directed.
S & F in replacement of Modular ceiling fan regulator including connecting up electrically complete all as specified and directed.
M&L for Earthing complete with using GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using 4 mm dia GI Wire as earth lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 15 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate NO-3 of SSR Part-I complete all as specified and directed and testing on completiopn (Note:- If the desired resistance is not found earthing shall be redone by the contractor at no extra cost to Govt).
JESWIN BUILDERS
Shri T P ANIL KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .